{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T06:56:30Z","timestamp":1793429790840,"version":"4.5.0"},"reference-count":46,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T00:00:00Z","timestamp":1769040000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>\n                      This study aims to compare different intraocular pressure (IOP) correction formulas in post-refractive surgery patients who underwent Femtosecond Laser-Assisted\n                      <jats:italic>In Situ<\/jats:italic>\n                      Keratomileusis (FS-LASIK), Small Incision Lenticule Extraction (SMILE), and Trans-epithelial Photorefractive Keratectomy (tPRK), and to identify the most accurate formula for correcting IOP values measured by Goldmann applanation tonometer (GAT).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This prospective study included 160 patients (160 eyes) who underwent FS-LASIK (58 eyes), SMILE (52 eyes), or tPRK (50 eyes) at the Eye Hospital, Wenzhou Medical University. IOP was measured using GAT and Dynamic Contour Tonometry (DCT) preoperatively and 3\u00a0months postoperatively. Optical zone diameter, ablation depth (AD), residual stromal thickness, refractive error correction, central corneal thickness (CCT), and mean corneal curvature (Km) were collected. Fourteen published GAT correction formulas (F1\u2013F14) were applied to postoperative GAT values and compared with preoperative measurements. Differences between pre- and postoperative DCT readings served as a reference.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>In FS-LASIK and SMILE, formulas F3, F4, and F11 showed superior correction performance. In FS-LASIK, the mean differences, concordance correlation coefficients (CCC), and proportions of differences within \u00b12\u00a0mmHg were closer to or better than the DCT reference (0.58, 0.572, 55.17%), with F3 (0.25, 0.372, 72.41%), F4 (0.20, 0.373, 63.79%), and F11 (0.04, 0.324, 67.24%) showing high agreement. Similarly, in SMILE, F3 (0.25, 0.379, 57.69%), F4 (0.22, 0.375, 61.54%), and F11 (0.01, 0.399, 63.46%) outperformed or approximated DCT (0.86, 0.447, 44.23%). In tPRK, F1 (0.18, 0.653, 64.00%) and F2 (0.25, 0.316, 62.00%) provided better correction than DCT (0.19, 0.493, 56.00%).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Formulas F3, F4, and F11 are applicable for GAT IOP correction in both FS-LASIK and SMILE eyes. F1 and F2 are more suitable for tPRK; the preoperative IOP parameters included in F1 may lead to assessment bias, making F2 the recommended choice when preoperative IOP is unavailable.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fbioe.2026.1735079","type":"journal-article","created":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T06:54:31Z","timestamp":1769064871000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Comparison of correction formulas for intraocular pressure measured by Goldmann tonometer following various refractive surgeries (FS-LASIK, SMILE, tPRK)"],"prefix":"10.3389","volume":"14","author":[{"given":"Jie","family":"Tong","sequence":"first","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kai","family":"Zhou","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"HongJiang","family":"Wu","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"YeWei","family":"Zhao","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ZhanHao","family":"Gu","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"YiQian","family":"Li","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"JiaHui","family":"Zong","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"XuanYa","family":"Tong","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"XiaoFei","family":"Zhou","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"LuMeng","family":"Wang","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ShiHao","family":"Chen","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]},{"name":"State Key Laboratory of Ophthalmology, Optometry and Vision Sicence, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]},{"name":"National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]},{"name":"ZheJiang-United Kingdom Joint Lab of Ocular Biomechanics","place":["Wenzhou, China"]},{"name":"The Institute of Ocular Biomechanics, Wenzhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jia","family":"Qu","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]},{"name":"State Key Laboratory of Ophthalmology, Optometry and Vision Sicence, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]},{"name":"National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]},{"name":"ZheJiang-United Kingdom Joint Lab of Ocular Biomechanics","place":["Wenzhou, China"]},{"name":"The Institute of Ocular Biomechanics, Wenzhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"QinMei","family":"Wang","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]},{"name":"State Key Laboratory of Ophthalmology, Optometry and Vision Sicence, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]},{"name":"National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]},{"name":"ZheJiang-United Kingdom Joint Lab of Ocular Biomechanics","place":["Wenzhou, China"]},{"name":"The Institute of Ocular Biomechanics, Wenzhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"DongYe","family":"Xu","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Elsheikh","sequence":"additional","affiliation":[{"name":"OuJiang Laboratory, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]},{"name":"School of Engineering, University of Liverpool","place":["Liverpool, United Kingdom"]},{"name":"National Institute for Health Research (NIHR) Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology","place":["London, United Kingdom"]},{"name":"Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"FangJun","family":"Bao","sequence":"additional","affiliation":[{"name":"National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]},{"name":"State Key Laboratory of Ophthalmology, Optometry and Vision Sicence, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]},{"name":"National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]},{"name":"ZheJiang-United Kingdom Joint Lab of Ocular Biomechanics","place":["Wenzhou, China"]},{"name":"The Institute of Ocular Biomechanics, Wenzhou Medical University","place":["Wenzhou, China"]},{"name":"OuJiang Laboratory, Eye Hospital, WenZhou Medical University","place":["Wenzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,1,22]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"2477","DOI":"10.2147\/OPTH.S115203","article-title":"Comparison of goldmann applanation tonometry and pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature","volume":"10","author":"Andreanos","year":"2016","journal-title":"Clin. Ophthalmology Auckl. NZ"},{"key":"B2","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1016\/s0021-5155(02)00555-5","article-title":"Underestimation of intraocular pressure in eyes after laser in situ keratomileusis","volume":"46","author":"Arimoto","year":"2002","journal-title":"Jpn. Journal Ophthalmology"},{"key":"B3","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1007\/s00417-010-1431-9","article-title":"Comparison between pascal dynamic contour tonometer and goldmann applanation tonometer after different types of refractive surgery","volume":"249","author":"Aristeidou","year":"2011","journal-title":"Graefe's Archive Clinical Experimental Ophthalmology"},{"key":"B4","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.clinbiomech.2019.09.007","article-title":"Finite element simulation of goldmann tonometry after refractive surgery","volume":"71","author":"Asejczyk-Widlicka","year":"2020","journal-title":"Clin. Biomechanics (Bristol, Avon)"},{"key":"B5","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1080\/02713683.2022.2103569","article-title":"Corneal biomechanics losses caused by refractive surgery","volume":"48","author":"Bao","year":"2023","journal-title":"Curr. Eye Res."},{"key":"B6","doi-asserted-by":"publisher","first-page":"2472","DOI":"10.1167\/iovs.07-1366","article-title":"Dynamic contour tonometry in comparison to intracameral IOP measurements","volume":"49","author":"Boehm","year":"2008","journal-title":"Invest Ophthalmol. Vis. Sci."},{"key":"B7","doi-asserted-by":"publisher","first-page":"3860","DOI":"10.3390\/jcm10173860","article-title":"How to measure intraocular pressure: an updated review of various tonometers","volume":"10","author":"Brusini","year":"2021","journal-title":"J. Clinical Medicine"},{"key":"B8","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1167\/iovs.64.6.2","article-title":"IMI-onset and progression of myopia in young adults","volume":"64","author":"Bullimore","year":"2023","journal-title":"Investigative Ophthalmology & Visual Science"},{"key":"B9","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1038\/sj.eye.6703102","article-title":"Comparison of goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes","volume":"23","author":"Ceruti","year":"2009","journal-title":"Eye Lond. Engl."},{"key":"B10","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1016\/s0161-6420(97)30308-x","article-title":"Reduction in intraocular pressure after excimer laser photorefractive keratectomy. Correlation with pretreatment myopia","volume":"104","author":"Chatterjee","year":"1997","journal-title":"Ophthalmology"},{"key":"B11","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1136\/bjo.2004.048074","article-title":"The preoperative intraocular pressure level predicts the amount of underestimated intraocular pressure after LASIK for myopia","volume":"89","author":"Chihara","year":"2005","journal-title":"Br. Journal Ophthalmology"},{"key":"B12","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1016\/j.ophtha.2022.11.030","article-title":"Mendelian randomization implicates bidirectional association between myopia and primary open-angle glaucoma or intraocular pressure","volume":"130","author":"Chong","year":"2023","journal-title":"Ophthalmology"},{"key":"B13","doi-asserted-by":"publisher","first-page":"233","DOI":"10.3109\/08820538.2014.962156","article-title":"Intraocular pressure evaluation after myopic refractive surgery: a comparison of methods in 121 eyes","volume":"31","author":"De Bernardo","year":"2016","journal-title":"Seminars Ophthalmology"},{"key":"B14","doi-asserted-by":"publisher","first-page":"25158414241287431","DOI":"10.1177\/25158414241287431","article-title":"Early diagnostics and interventional glaucoma","volume":"16","author":"De Francesco","year":"2024","journal-title":"Ther. Advances Ophthalmology"},{"key":"B15","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1097\/00061198-200108000-00003","article-title":"Tonometry after laser in situ keratomileusis treatment","volume":"10","author":"Duch","year":"2001","journal-title":"J. Glaucoma"},{"key":"B16","doi-asserted-by":"publisher","first-page":"1320","DOI":"10.1016\/s0886-3350(98)80222-8","article-title":"Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis","volume":"24","author":"Emara","year":"1998","journal-title":"J. Cataract Refractive Surgery"},{"key":"B17","doi-asserted-by":"publisher","first-page":"141","DOI":"10.11613\/BM.2015.015","article-title":"Understanding bland altman analysis","volume":"25","author":"Giavarina","year":"2015","journal-title":"Biochem. Med. Zagreb."},{"key":"B18","doi-asserted-by":"publisher","first-page":"740","DOI":"10.1001\/archopht.125.6.740","article-title":"Effect of central corneal thickness on dynamic contour tonometry and goldmann applanation tonometry in primary open-angle glaucoma","volume":"125","author":"Grieshaber","year":"2007","journal-title":"Archives Ophthalmol."},{"key":"B19","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1167\/tvst.12.3.12","article-title":"Corneal biomechanics after SMILE, femtosecond-assisted LASIK, and photorefractive keratectomy: a matched comparison study","volume":"12","author":"Hashemi","year":"2023","journal-title":"Transl. Vision Science & Technology"},{"key":"B20","doi-asserted-by":"publisher","first-page":"509","DOI":"10.2147\/OPTH.S239329","article-title":"Intraocular pressure calculation in myopic patients after laser-assisted in situ keratomileusis","volume":"14","author":"Helmy","year":"2020","journal-title":"Clin. Ophthalmology Auckl. NZ"},{"key":"B21","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1097\/01.ijg.0000176936.16015.4e","article-title":"Dynamic contour tonometry: presentation of a new tonometer","volume":"14","author":"Kanngiesser","year":"2005","journal-title":"J. Glaucoma"},{"key":"B22","doi-asserted-by":"publisher","first-page":"3790","DOI":"10.1167\/iovs.02-0946","article-title":"Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis","volume":"44","author":"Kaufmann","year":"2003","journal-title":"Invest Ophthalmol. Vis. Sci."},{"key":"B23","doi-asserted-by":"publisher","first-page":"3118","DOI":"10.1167\/iovs.04-0018","article-title":"Comparison of dynamic contour tonometry with goldmann applanation tonometry","volume":"45","author":"Kaufmann","year":"2004","journal-title":"Investigative Ophthalmology & Visual Science"},{"key":"B24","doi-asserted-by":"publisher","first-page":"1287","DOI":"10.1001\/archopht.122.9.1287","article-title":"Dynamic contour tonometry: a comparative study on human cadaver eyes","volume":"122","author":"Kniestedt","year":"2004","journal-title":"Arch. Ophthalmol."},{"key":"B25","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1007\/s00417-004-1024-6","article-title":"Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration states","volume":"243","author":"Kniestedt","year":"2005","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"B26","doi-asserted-by":"publisher","first-page":"263","DOI":"10.3928\/1081-597X-20060301-11","article-title":"A correction formula for the real intraocular pressure after LASIK for the correction of myopic astigmatism","volume":"22","author":"Kohlhaas","year":"","journal-title":"J. Refractive Surgery"},{"key":"B27","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1001\/archopht.124.4.471","article-title":"Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry","volume":"124","author":"Kohlhaas","year":"","journal-title":"Archives Ophthalmology"},{"key":"B28","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1016\/j.jclinepi.2010.03.002","article-title":"Guidelines for reporting reliability and agreement studies (GRRAS) were proposed","volume":"64","author":"Kottner","year":"2011","journal-title":"J. Clin. Epidemiol."},{"key":"B29","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1038\/sj.eye.6701849","article-title":"Comparison of intraocular pressure measured by pascal dynamic contour tonometry and goldmann applanation tonometry","volume":"20","author":"Ku","year":"2006","journal-title":"Eye (Lond)."},{"key":"B30","doi-asserted-by":"publisher","first-page":"255","DOI":"10.2307\/2532051","article-title":"A concordance correlation coefficient to evaluate reproducibility","volume":"45","author":"Lin","year":"1989","journal-title":"Biometrics"},{"key":"B31","first-page":"159","article-title":"Correction of intraocular pressure for changes in central corneal thickness following photorefractive keratectomy","volume":"33","author":"Munger","year":"1998","journal-title":"Can. Journal Ophthalmology J. Canadien D'ophtalmologie"},{"key":"B32","doi-asserted-by":"publisher","first-page":"243","DOI":"10.3390\/jcm12010243","article-title":"Clinical evaluation of corneal biomechanics following laser refractive surgery in myopic eyes: a review of the literature","volume":"12","author":"Pniakowska","year":"2022","journal-title":"J. Clin. Med."},{"key":"B33","doi-asserted-by":"publisher","first-page":"420","DOI":"10.3928\/1081-597X-20010701-03","article-title":"Changes in intraocular pressure after laser in situ keratomileusis","volume":"17","author":"Rashad","year":"2001","journal-title":"J. Refractive Surgery"},{"key":"B34","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1034\/j.1600-0420.1998.760508.x","article-title":"Goldmann applanation tonometry after myopic photorefractive keratectomy","volume":"76","author":"Rosa","year":"1998","journal-title":"Acta Ophthalmologica Scand."},{"key":"B35","doi-asserted-by":"publisher","first-page":"366","DOI":"10.3928\/1081-597X-19950901-13","article-title":"Intraocular pressure after excimer laser photorefractive keratectomy for myopia","volume":"11","author":"Schipper","year":"1995","journal-title":"J. Refractive Surgery"},{"key":"B36","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1097\/01.ijg.0000196655.85460.d6","article-title":"Intraocular pressure measurement-comparison of dynamic contour tonometry and goldmann applanation tonometry","volume":"15","author":"Schneider","year":"2006","journal-title":"J. Glaucoma"},{"key":"B37","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1097\/IJG.0b013e31829da1ec","article-title":"Changes in biomechanical properties of the cornea and intraocular pressure after myopic laser in situ keratomileusis using a femtosecond laser for flap creation determined using ocular response analyzer and goldmann applanation tonometry","volume":"24","author":"Shin","year":"2015","journal-title":"J. Glaucoma"},{"key":"B38","doi-asserted-by":"publisher","first-page":"746","DOI":"10.1016\/j.jcrs.2003.12.033","article-title":"Assessment of the pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK","volume":"30","author":"Siganos","year":"2004","journal-title":"J. Cataract Refractive Surgery"},{"key":"B39","doi-asserted-by":"publisher","first-page":"011002","DOI":"10.1115\/1.4002934","article-title":"Patient-specific modeling of corneal refractive surgery outcomes and inverse estimation of elastic property changes","volume":"133","author":"Sinha Roy","year":"2011","journal-title":"J. Biomech. Eng."},{"key":"B40","doi-asserted-by":"publisher","first-page":"562","DOI":"10.3390\/biom13030562","article-title":"Glaucoma and myopia: diagnostic challenges","volume":"13","author":"Sun","year":"2023","journal-title":"Biomolecules"},{"key":"B41","doi-asserted-by":"publisher","first-page":"1218","DOI":"10.1007\/s00417-005-0072-x","article-title":"Changes in corneal thickness and curvature after different excimer laser photorefractive procedures and their impact on intraocular pressure measurements","volume":"243","author":"Svedberg","year":"2005","journal-title":"Graefe's Archive Clinical Experimental Ophthalmology"},{"key":"B42","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1001\/jamaophthalmol.2017.1012","article-title":"Correlation between dynamic contour tonometry, uncorrected and corrected goldmann applanation tonometry, and stage of glaucoma","volume":"135","author":"Wachtl","year":"2017","journal-title":"JAMA Ophthalmol."},{"key":"B43","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1111\/cxo.12861","article-title":"Intraocular pressure changes in eyes with small incision lenticules and laser in situ keratomileusis","volume":"102","author":"Wang","year":"2019","journal-title":"Clin. & Experimental Optometry"},{"key":"B44","doi-asserted-by":"publisher","first-page":"834270","DOI":"10.3389\/fbioe.2022.834270","article-title":"Biomechanical effects of tPRK, FS-LASIK, and SMILE on the cornea","volume":"10","author":"Xin","year":"2022","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B45","doi-asserted-by":"publisher","first-page":"437","DOI":"10.3928\/15428877-20100426-01","article-title":"A clinical comparison of dynamic contour tonometry versus goldmann applanation tonometry","volume":"41","author":"Yalcinbayir","year":"2010","journal-title":"Ophthalmic Surgery, Lasers & Imaging"},{"key":"B46","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1186\/s12886-022-02620-7","article-title":"Comparison of different correction formulas and measurement methods for the accurate determination of intraocular pressure after SMILE and FS-LASIK surgery","volume":"22","author":"Yang","year":"2022","journal-title":"BMC Ophthalmology"}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2026.1735079\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T06:54:32Z","timestamp":1769064872000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2026.1735079\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,22]]},"references-count":46,"alternative-id":["10.3389\/fbioe.2026.1735079"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2026.1735079","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,22]]},"article-number":"1735079"}}