{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,2]],"date-time":"2026-03-02T07:02:36Z","timestamp":1772434956066,"version":"3.50.1"},"reference-count":51,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,3,2]],"date-time":"2026-03-02T00:00:00Z","timestamp":1772409600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Magnesium degradation-induced variable fixation plates (MVFPs) offer different fixation modes during fracture healing, but their biomechanical reliability is not well established.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods<\/jats:title>\n                    <jats:p>CT images of femurs from volunteers were used to build a model, and Abaqus software simulated deformation, stress, and relative displacement under various stress conditions. Mechanical tests including vertical loading, four-point bending, torsion, and fatigue were conducted using femur simulation models and suitable magnesium shims were screened.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Finite element analysis showed that under 700N vertical loading, MVFP exhibited 83%\u2013116% of the total deformation, 88%\u2013120% of the maximum stress, and 86%\u2013121% of the average relative displacement compared to locking plate (LP). Under 250N four-point bending, these were 76%\u2013186%, 73%\u2013183%, and 61%\u2013170%, respectively. Under 10Nm torsional moment, they were 102%\u2013109%, 114%\u2013118% (for implants), and 110%\u2013113%, respectively.\n                      <jats:italic>In vitro<\/jats:italic>\n                      biomechanical tests showed that MVFP had greater total and relative displacements but lower axial, four-point bending, and torsional stiffness (81.5%, 68.5%, and 63.9% of LP, respectively). Fatigue testing indicated both LP and MVFP samples endured 100,000 cycles of 700N vertical load without failure. The MVFP with a 0.5\u00a0mm shim exhibited superior stiffness and offered greater space for elastic deformation compared to the 1\u00a0mm shim.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Although MVFP\u2019s stiffness slightly decreases compared to LP after shim degradation, it improves interfragmentary micromotion and reduces stress shielding while maintaining good fatigue resistance. MVFP with 0.5\u00a0mm axial micromotion shows promise for further development and clinical application.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fbioe.2026.1774985","type":"journal-article","created":{"date-parts":[[2026,3,2]],"date-time":"2026-03-02T06:32:30Z","timestamp":1772433150000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Finite element and in vitro biomechanical analysis of a novel magnesium degradation-induced variable fixation plate"],"prefix":"10.3389","volume":"14","author":[{"given":"Jian","family":"Wen","sequence":"first","affiliation":[{"name":"Department of Pain Management, The 2nd Affiliated Hospital, Jiangxi Medical College, Nanchang University","place":["Nanchang, Jiangxi, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xingyu","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, Jiangxi Province Hospital of Integrated Chinese and Western Medicine","place":["Nanchang, Jiangxi, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhe","family":"Wang","sequence":"additional","affiliation":[{"name":"JXHC Key Laboratory of Digital Orthopedics, Jiangxi Provincial People\u2019s Hospital, The First Affiliated Hospital of Nanchang Medical College","place":["Nanchang, Jiangxi, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yu","family":"Zeng","sequence":"additional","affiliation":[{"name":"JXHC Key Laboratory of Digital Orthopedics, Jiangxi Provincial People\u2019s Hospital, The First Affiliated Hospital of Nanchang Medical College","place":["Nanchang, Jiangxi, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaofan","family":"Chen","sequence":"additional","affiliation":[{"name":"JXHC Key Laboratory of Digital Orthopedics, Jiangxi Provincial People\u2019s Hospital, The First Affiliated Hospital of Nanchang Medical College","place":["Nanchang, Jiangxi, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xueqi","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Orthopedics, People\u2019s Hospital of Ningxia Hui Autonomous Region, Third Clinical Medical College of Ningxia Medical University, Ningxia Medical University","place":["Yinchuan, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xieping","family":"Dong","sequence":"additional","affiliation":[{"name":"JXHC Key Laboratory of Digital Orthopedics, Jiangxi Provincial People\u2019s Hospital, The First Affiliated Hospital of Nanchang Medical College","place":["Nanchang, Jiangxi, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2026,3,2]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.fas.2013.10.004","article-title":"A biomechanical evaluation of locked plating for distal fibula fractures in an osteoporotic sawbone model","volume":"20","author":"Bariteau","year":"2014","journal-title":"Foot Ankle Surgery"},{"key":"B2","doi-asserted-by":"publisher","first-page":"3229","DOI":"10.1016\/j.jbiomech.2008.08.003","article-title":"Evaluation of bone plate with low-stiffness material in terms of stress distribution","volume":"41","author":"Benli","year":"2008","journal-title":"J. Biomech."},{"key":"B3","doi-asserted-by":"publisher","first-page":"S21","DOI":"10.1097\/BOT.0b013e318207885b","article-title":"Biomechanics of far cortical locking","volume":"25","author":"Bottlang","year":"2011","journal-title":"J. Orthop. Trauma"},{"key":"B4","doi-asserted-by":"publisher","first-page":"12","DOI":"10.2106\/JBJS.J.00780","article-title":"Effects of construct stiffness on healing of fractures stabilized with locking plates","volume":"92","author":"Bottlang","year":"2010","journal-title":"J. Bone Jt. Surg. Am."},{"key":"B5","doi-asserted-by":"publisher","first-page":"466","DOI":"10.2106\/JBJS.O.00705","article-title":"Dynamic stabilization with active locking plates delivers faster, stronger, and more symmetric fracture-healing","volume":"98","author":"Bottlang","year":"2016","journal-title":"J. Bone Jt. Surg. Am."},{"key":"B6","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.jor.2024.09.013","article-title":"Far cortical locking versus standard locking screw fixation in simulated femoral fractures: a biomechanical meta-analysis","volume":"61","author":"Bullock","year":"2025","journal-title":"J. Orthop."},{"key":"B7","doi-asserted-by":"publisher","first-page":"110148","DOI":"10.1016\/j.jbiomech.2020.110148","article-title":"Improvement of clinical fracture healing - what can be learned from mechano-biological research?","volume":"115","author":"Claes","year":"2021","journal-title":"J. Biomech."},{"key":"B8","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/0268-0033(95)99799-8","article-title":"Effect of dynamization on gap healing of diaphyseal fractures under external fixation","volume":"10","author":"Claes","year":"1995","journal-title":"Clin. Biomech."},{"key":"B9","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1002\/jor.1100150414","article-title":"Influence of size and stability of the osteotomy gap on the success of fracture healing","volume":"15","author":"Claes","year":"1997","journal-title":"J. Orthop. Res."},{"key":"B10","doi-asserted-by":"publisher","first-page":"1099","DOI":"10.1016\/S0736-0266(02)00044-X","article-title":"The effect of mechanical stability on local vascularization and tissue differentiation in callus healing","volume":"20","author":"Claes","year":"2002","journal-title":"J. Orthop. Res."},{"key":"B11","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1097\/CORR.0000000000000945","article-title":"Does screw location affect the risk of subtrochanteric femur fracture after femoral neck fixation? A biomechanical study","volume":"478","author":"Crump","year":"2020","journal-title":"Clin. Orthopaedics Related Research"},{"key":"B12","doi-asserted-by":"publisher","first-page":"1796","DOI":"10.1016\/j.injury.2022.03.032","article-title":"Triangular support intramedullary nail: a new internal fixation innovation for treating intertrochanteric fracture and its finite element analysis","volume":"53","author":"Ding","year":"2022","journal-title":"Injury"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1297507","DOI":"10.3389\/fbioe.2023.1297507","article-title":"Proximal femoral bionic nail-a novel internal fixation system for the treatment of femoral neck fractures: a finite element analysis","volume":"11","author":"Ding","year":"2023","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B14","doi-asserted-by":"publisher","first-page":"276","DOI":"10.2106\/JBJS.O.00684","article-title":"Motion predicts clinical callus formation: construct-specific finite element analysis of supracondylar femoral fractures","volume":"98","author":"Elkins","year":"2016","journal-title":"J. Bone Jt. Surg. Am."},{"key":"B15","doi-asserted-by":"publisher","first-page":"1679","DOI":"10.1002\/jor.20230","article-title":"In vivo cyclic axial compression affects bone healing in the mouse tibia","volume":"24","author":"Gardner","year":"2006","journal-title":"J. Orthop. Res."},{"key":"B16","doi-asserted-by":"publisher","first-page":"652","DOI":"10.1016\/j.injury.2010.02.022","article-title":"Less rigid stable fracture fixation in osteoporotic bone using locked plates with near cortical slots","volume":"41","author":"Gardner","year":"2010","journal-title":"Injury"},{"key":"B17","doi-asserted-by":"publisher","first-page":"650","DOI":"10.1302\/0301-620X.67B4.4030869","article-title":"The influence of induced micromovement upon the healing of experimental tibial fractures","volume":"67","author":"Goodship","year":"1985","journal-title":"J. Bone Jt. Surg. Br."},{"key":"B18","doi-asserted-by":"publisher","first-page":"593448","DOI":"10.3389\/fbioe.2020.593448","article-title":"Axial micromotion locking plate construct can promote faster and stronger bone healing in an ovine osteotomy model","volume":"8","author":"Han","year":"2020","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B19","doi-asserted-by":"publisher","first-page":"104345","DOI":"10.1016\/j.jmbbm.2021.104345","article-title":"A novel design of printable tunable stiffness metamaterial for bone healing","volume":"116","author":"Hashemi","year":"2021","journal-title":"J. Mech. Behav. Biomed. Mater"},{"key":"B20","doi-asserted-by":"publisher","first-page":"107006","DOI":"10.1016\/j.cmpb.2022.107006","article-title":"Plate configuration for biological reconstructions of femoral intercalary defect - a finite element evaluation","volume":"224","author":"He","year":"2022","journal-title":"Comput. Methods Programs Biomed."},{"key":"B21","doi-asserted-by":"publisher","first-page":"1751","DOI":"10.1016\/j.injury.2020.04.032","article-title":"Biphasic plating - in vivo study of a novel fixation concept to enhance mechanobiological fracture healing","volume":"51","author":"Hofmann-Fliri","year":"2020","journal-title":"Injury"},{"key":"B22","doi-asserted-by":"publisher","first-page":"1638","DOI":"10.1111\/os.13308","article-title":"Spatial bridge locking fixator versus traditional locking plates in treating AO\/OTA 32-A3.2 fracture: finite element analysis and biomechanical evaluation","volume":"14","author":"Hu","year":"2022","journal-title":"Orthop. Surg."},{"key":"B23","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1002\/jor.25968","article-title":"Mechanically compliant locking plates for diaphyseal fracture fixation: a biomechanical study","volume":"43","author":"Huxman","year":"","journal-title":"J. Orthop. Res."},{"key":"B24","doi-asserted-by":"publisher","first-page":"1271","DOI":"10.1007\/s10439-025-03714-1","article-title":"Dynamic fracture fixation plates: a systematic review of evolving design approaches","volume":"53","author":"Huxman","year":"","journal-title":"Ann. Biomed. Eng."},{"key":"B25","doi-asserted-by":"publisher","first-page":"011008","DOI":"10.1115\/1.4070406","article-title":"Flexure-based locking plates can modulate interfragmentary motion in distal femur and diaphyseal fractures: a parametric finite element analysis","volume":"148","author":"Huxman","year":"2026","journal-title":"J. Biomech. Eng."},{"key":"B26","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1016\/0010-4485(84)90036-8","article-title":"Finite-element analysis","volume":"16","author":"Knowles","year":"1984","journal-title":"Computer-aided Design"},{"key":"B27","doi-asserted-by":"publisher","first-page":"e10835","DOI":"10.1002\/jbm4.10835","article-title":"Anisotropy, anatomical region, and additional variables influence young's modulus of bone: a systematic review and meta-analysis","volume":"7","author":"Kov\u00e1cs","year":"2023","journal-title":"JBMR Plus"},{"key":"B28","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/j.ajodo.2020.10.017","article-title":"Finite element analysis: is it justifiable?","volume":"159","author":"Lagrav\u00e8re","year":"2021","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"B29","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1002\/jor.23065","article-title":"Enhancing fixation strength in periprosthetic femur fractures by orthogonal plating-A biomechanical study","volume":"34","author":"Lenz","year":"2016","journal-title":"J. Orthop. Res."},{"key":"B30","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1007\/s11914-021-00690-y","article-title":"Finite element analysis of fracture fixation","volume":"19","author":"Lewis","year":"2021","journal-title":"Curr. Osteoporos. Rep."},{"key":"B31","doi-asserted-by":"publisher","first-page":"1088","DOI":"10.1002\/jor.25447","article-title":"Novel slide compression anatomic plates of the femoral neck for treating unstable femoral neck fracture: a biomechanical study","volume":"41","author":"Li","year":"2023","journal-title":"J. Orthop. Res."},{"key":"B32","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1016\/j.orthres.2004.09.006","article-title":"Initial vascularization and tissue differentiation are influenced by fixation stability","volume":"23","author":"Lienau","year":"2005","journal-title":"J. Orthop. Res."},{"key":"B33","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.bone.2017.12.027","article-title":"Effects of mechanical loading on cortical defect repair using a novel mechanobiological model of bone healing","volume":"108","author":"Liu","year":"2018","journal-title":"Bone"},{"key":"B34","doi-asserted-by":"publisher","first-page":"10225536251352559","DOI":"10.1177\/10225536251352559","article-title":"Advancements in micromotion-based fixation systems for fracture healing","volume":"33","author":"Lv","year":"2025","journal-title":"J. Orthop. Surg."},{"key":"B35","doi-asserted-by":"publisher","first-page":"1133869","DOI":"10.3389\/fbioe.2023.1133869","article-title":"Experimental analysis and numerical fatigue life prediction of 3D-Printed osteosynthesis plates","volume":"11","author":"Nakhaei","year":"2023","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B36","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1007\/s00264-010-0983-y","article-title":"Comparison of mechanical rigidity between plate augmentation leaving the nail in situ and interlocking nail using cadaveric fracture model of the femur","volume":"35","author":"Park","year":"2011","journal-title":"Int. Orthop."},{"key":"B37","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1186\/s12891-020-03781-6","article-title":"Variable fixation promotes callus formation: an experimental study on transverse tibial osteotomies stabilized with locking plates","volume":"21","author":"Plecko","year":"2020","journal-title":"BMC Musculoskelet. Disord."},{"key":"B38","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1016\/0022-3913(90)90325-7","article-title":"Finite-element analysis of 6 endosseous implants","volume":"63","author":"Rieger","year":"1990","journal-title":"J. Prosthetic Dentistry"},{"key":"B39","doi-asserted-by":"publisher","first-page":"1648","DOI":"10.1016\/j.injury.2014.04.018","article-title":"Delayed bone healing following high tibial osteotomy related to increased implant stiffness in locked plating","volume":"45","author":"R\u00f6derer","year":"2014","journal-title":"Injury"},{"key":"B40","doi-asserted-by":"publisher","DOI":"10.1088\/2057-1976\/ad38c4","article-title":"Effect of matrix material property on the composite tibia fracture plate: a biomechanical study","volume":"10","author":"Roy","year":"2024","journal-title":"Biomed. Phys. Eng. Express"},{"key":"B41","doi-asserted-by":"publisher","first-page":"3298","DOI":"10.3390\/ma16093298","article-title":"Biomechanical effects of the porous structure of gyroid and voronoi hip implants: a finite element analysis using an experimentally validated model","volume":"16","author":"Salaha","year":"2023","journal-title":"Materials"},{"key":"B42","doi-asserted-by":"publisher","first-page":"2040","DOI":"10.1016\/j.injury.2014.08.036","article-title":"Plate selection for fixation of extra-articular distal humerus fractures: a biomechanical comparison of three different implants","volume":"45","author":"Scolaro","year":"2014","journal-title":"Injury-international Journal Care Injured"},{"key":"B43","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/0167-5273(89)90080-6","article-title":"Primary cardiac amyloidosis with pathologic hip fracture secondary to bone amyloid","volume":"22","author":"Sundar","year":"1989","journal-title":"Int. J. Cardiol."},{"key":"B44","doi-asserted-by":"publisher","first-page":"1943","DOI":"10.1002\/jor.25203","article-title":"The insidious risk of periprosthetic fracture in clinically functional total hip arthroplasties: a biomechanical study of willed joints","volume":"40","author":"Takamura","year":"2022","journal-title":"J. Orthop. Res."},{"key":"B45","first-page":"281","article-title":"The vascular response to fracture micromovement","author":"Wallace","year":"1994","journal-title":"Clin. Orthop. Relat. Res."},{"key":"B46","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1097\/BSD.0000000000001050","article-title":"What is finite element analysis?","volume":"33","author":"Welch-Phillips","year":"2020","journal-title":"Clin. Spine Surg."},{"key":"B47","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1186\/s10195-024-00803-0","article-title":"Magnesium degradation-induced variable fixation plates promote bone healing in rabbits","volume":"25","author":"Wen","year":"2024","journal-title":"J. Orthop. Traumatol."},{"key":"B48","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-025-06528-y","article-title":"Magnesium degradation-induced variable fixation plates promote the vascularization of femoral fracture in rabbits","volume":"93","author":"Wen","year":"2026","journal-title":"J. Orthop. Surg"},{"key":"B49","doi-asserted-by":"publisher","first-page":"630","DOI":"10.3113\/FAI.2011.0630","article-title":"Anterolateral and medial locking plate stiffness in distal tibial fracture model","volume":"32","author":"Yenna","year":"2011","journal-title":"Foot and Ankle International"},{"key":"B50","doi-asserted-by":"publisher","first-page":"104017","DOI":"10.1016\/j.medengphy","article-title":"Biomechanical properties of artificial bones made by sawbones: a review","author":"Zdero","year":"2023","journal-title":"Med. Engineering and Physics"},{"key":"B51","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1080\/08941939.2020.1836290","article-title":"Effects of bone-plate material on the predicted stresses in the tibial shaft comminuted fractures: a finite element analysis","volume":"35","author":"Zhou","year":"2022","journal-title":"J. Invest Surg."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2026.1774985\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,2]],"date-time":"2026-03-02T06:32:31Z","timestamp":1772433151000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2026.1774985\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,2]]},"references-count":51,"alternative-id":["10.3389\/fbioe.2026.1774985"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2026.1774985","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,2]]},"article-number":"1774985"}}