{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T07:15:53Z","timestamp":1788419753147,"version":"build-2803163510"},"reference-count":149,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T00:00:00Z","timestamp":1788393600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000925","name":"National Health and Medical Research Council","doi-asserted-by":"publisher","award":["2001734"],"award-info":[{"award-number":["2001734"]}],"id":[{"id":"10.13039\/501100000925","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p>Orthopaedic surgical outcomes remain variable due to the poorly characterised, patient-specific post-surgical mechanical and physiological environment of implants and tissues. Differences in anatomy, alignment, neuromuscular function, and movement govern surgical-site loading and the tissue-level environment that drive healing. Coupled neuromusculoskeletal-finite element analysis (NMSK-FEA) workflows link these factors to the tissue-level mechanical and physiological environment, enabling preoperative evaluation of surgical strategies. This paper outlines current methodological considerations for the development and application of coupled NMSK-FEA workflows in orthopaedic biomechanics and identifies key priorities for their translation into clinically useful decision-support tools. We discuss methodological considerations and rationale for creating personalised MSK and NMSK models, patient-specific FEA geometry and material definition, transfer of NMSK outputs into FEA motion, loading, and boundary conditions, and selection of clinically relevant output measures. The workflow enforces NMSK and FEA parameter and boundary condition constraints to generate physiologically plausible outputs. Case studies of anterior cruciate ligament reconstruction and proximal femoral osteotomy are presented as methodological exemplars to illustrate how these NMSK-FEA workflow recommendations can be operationalised. These examples of NMSK-FEA workflows used in clinical cases show that mechanically optimal solutions can differ substantially between patients, thereby reinforcing the need for personalised biomechanical assessment. This paper presents practical recommendations for standardising and validating workflows and communicating key findings in a format that supports clinical decision making, laying the groundwork for prospective clinical validation. Together, these recommendations help move orthopaedic surgery planning beyond population averages towards patient-specific decision support at the point of care.<\/jats:p>","DOI":"10.3389\/fbioe.2026.1875782","type":"journal-article","created":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T06:40:25Z","timestamp":1788417625000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Evidence-informed methodological approaches for coupled neuromusculoskeletal-finite element analysis workflows in orthopaedic biomechanics"],"prefix":"10.3389","volume":"14","author":[{"given":"Alireza Y.","family":"Bavil","sequence":"first","affiliation":[{"name":"School of Mechanical Engineering and Industrial Design, Griffith University","place":["Gold Coast, QLD, Australia"]},{"name":"Australian Centre for Precision Health and Technology (PRECISE), Griffith University","place":["Gold Coast, QLD, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ayda","family":"Karimi Dastgerdi","sequence":"additional","affiliation":[{"name":"Australian Centre for Precision Health and Technology (PRECISE), Griffith University","place":["Gold Coast, QLD, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rod S.","family":"Barrett","sequence":"additional","affiliation":[{"name":"Australian Centre for Precision Health and Technology (PRECISE), Griffith University","place":["Gold Coast, QLD, Australia"]},{"name":"School of Allied Health, Sport and Social Work, Griffith University","place":["Gold Coast, QLD, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bradley M.","family":"Cornish","sequence":"additional","affiliation":[{"name":"Australian Centre for Precision Health and Technology (PRECISE), Griffith University","place":["Gold Coast, QLD, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew J.","family":"Hambly","sequence":"additional","affiliation":[{"name":"Australian Centre for Precision Health and Technology (PRECISE), Griffith University","place":["Gold Coast, QLD, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew","family":"Carrall-Worsey","sequence":"additional","affiliation":[{"name":"Australian Centre for Precision Health and Technology (PRECISE), Griffith University","place":["Gold Coast, QLD, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claudio","family":"Pizzolato","sequence":"additional","affiliation":[{"name":"Australian Centre for Precision Health and Technology (PRECISE), Griffith University","place":["Gold Coast, QLD, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amir","family":"Esrafilian","sequence":"additional","affiliation":[{"name":"Australian Centre for Precision Health and Technology (PRECISE), Griffith University","place":["Gold Coast, QLD, Australia"]},{"name":"Department of Technical Physics, Faculty of Science, Forestry and Technology, University of Eastern Finland","place":["Kuopio, Finland"]},{"name":"School of Human Sciences, University of Western Australia","place":["Perth, WA, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dale","family":"Robinson","sequence":"additional","affiliation":[{"name":"School of Mechanical and Mining Engineering, University of Queensland","place":["Brisbane, QLD, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laurent","family":"Frossard","sequence":"additional","affiliation":[{"name":"Australian Centre for Precision Health and Technology (PRECISE), Griffith University","place":["Gold Coast, QLD, Australia"]},{"name":"School of Exercise and Nutrition Sciences, Queensland University of Technology","place":["Brisbane, QLD, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David John","family":"Saxby","sequence":"additional","affiliation":[{"name":"Australian Centre for Precision Health and Technology (PRECISE), Griffith University","place":["Gold Coast, QLD, Australia"]},{"name":"School of Allied Health, Sport and Social Work, Griffith University","place":["Gold Coast, QLD, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefanie","family":"Feih","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering and Industrial Design, Griffith University","place":["Gold Coast, QLD, Australia"]},{"name":"Australian Centre for Precision Health and Technology (PRECISE), Griffith University","place":["Gold Coast, QLD, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher P.","family":"Carty","sequence":"additional","affiliation":[{"name":"Australian Centre for Precision Health and Technology (PRECISE), Griffith University","place":["Gold Coast, QLD, Australia"]},{"name":"School of Medicine and Dentistry, Griffith University","place":["Southport, QLD, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David G.","family":"Lloyd","sequence":"additional","affiliation":[{"name":"Australian Centre for Precision Health and Technology (PRECISE), Griffith University","place":["Gold Coast, QLD, Australia"]},{"name":"School of Allied Health, Sport and Social Work, Griffith University","place":["Gold Coast, QLD, Australia"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,9,3]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"7940242","DOI":"10.1155\/2021\/7940242","article-title":"Preoperative planning using 3D printing technology in orthopedic surgery","volume":"2021","author":"Alemayehu","year":"2021","journal-title":"Biomed. Res. Int."},{"key":"B2","doi-asserted-by":"publisher","first-page":"19987","DOI":"10.1038\/s41598-025-04792-w","article-title":"Advantages of digital twin technology in orthopedic trauma surgery - exploring different clinical use cases","volume":"15","author":"Andres","year":"2025","journal-title":"Sci. Rep."},{"key":"B3","doi-asserted-by":"publisher","first-page":"4235","DOI":"10.1109\/TNSRE.2023.3323516","article-title":"EMG-Driven musculoskeletal model calibration with wrapping surface personalization","volume":"31","author":"Ao","year":"2023","journal-title":"IEEE Trans. Neural Syst. Rehabilitation Eng."},{"key":"B4","volume-title":"V&V 40 - Assessing Credibility of Computational Modeling Through Verification and Validation: Application to Medical Devices","year":"2018"},{"key":"B5","volume-title":"VVUQ 40.1 - An Example of Assessing Computational Model Credibility Using the ASME V&V 40 Risk-based Framework: Tibial Tray Component Worst-Case Size Identification for Fatigue Testing","year":"2026"},{"key":"B6","doi-asserted-by":"publisher","first-page":"10808","DOI":"10.1038\/s41598-024-61305-x","article-title":"Effect of different constraining boundary conditions on simulated femoral stresses and strains during gait","volume":"14","author":"Bavil","year":"2024","journal-title":"Sci. Rep."},{"key":"B7","doi-asserted-by":"publisher","first-page":"842","DOI":"10.1002\/jor.26043","article-title":"Effect of postoperative neck-shaft and anteversion angles on biomechanical outcomes in proximal femoral osteotomy: an in silico study","volume":"43","author":"Bavil","year":"2025","journal-title":"J. Orthop. Res."},{"key":"B8","doi-asserted-by":"publisher","first-page":"100919","DOI":"10.1016\/j.irbm.2025.100919","article-title":"Selected postoperative neck-shaft angle in proximal femoral osteotomy can affect the bone healing: a finite element study","volume":"47","author":"Bavil","year":"2026","journal-title":"IRBM"},{"key":"B9","doi-asserted-by":"publisher","first-page":"2268","DOI":"10.1109\/TBME.2022.3141067","article-title":"EMG-Informed neuromusculoskeletal models accurately predict knee loading measured using instrumented implants","volume":"69","author":"Bennett","year":"2022","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"B10","volume-title":"The co-ordination and Regulation of Movements","author":"Bernstein","year":"1967"},{"key":"B11","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1097\/00005768-200301000-00019","article-title":"Muscle activation strategies at the knee during running and cutting maneuvers","volume":"35","author":"Besier","year":"2003","journal-title":"Med. Sci. Sports Exerc."},{"key":"B12","doi-asserted-by":"publisher","first-page":"17351","DOI":"10.1038\/s41598-018-35628-5","article-title":"Comparison between kinetic and kinetic-kinematic driven knee joint finite element models","volume":"8","author":"Bolcos","year":"2018","journal-title":"Sci. Rep."},{"key":"B13","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/0304-3940(95)11727-e","article-title":"Muscle activity is different for humans performing static tasks which require force control and position control","volume":"194","author":"Buchanan","year":"1995","journal-title":"Neurosci. Lett."},{"key":"B14","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1097\/00005768-199607000-00014","article-title":"Selective muscle activation following rapid varus\/valgus perturbations at the knee","volume":"28","author":"Buchanan","year":"1996","journal-title":"Med. Sci. Sports Exerc."},{"key":"B15","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1249\/jsr.0000000000000601","article-title":"Musculoskeletal simulation tools for understanding mechanisms of lower-limb sports injuries","volume":"18","author":"Bulat","year":"2019","journal-title":"Curr. Sports Med. Rep."},{"key":"B16","doi-asserted-by":"publisher","first-page":"1477","DOI":"10.1016\/j.jbiomech.2013.03.022","article-title":"Finite element modeling mesh quality, energy balance and validation methods: a review with recommendations associated with the modeling of bone tissue","volume":"46","author":"Burkhart","year":"2013","journal-title":"J. Biomech."},{"key":"B17","doi-asserted-by":"publisher","first-page":"041004","DOI":"10.1115\/1.4026228","article-title":"Subject-specific finite element modeling of the tibiofemoral joint based on CT, magnetic resonance imaging and dynamic stereo-radiography data in vivo","volume":"136","author":"Carey","year":"2014","journal-title":"J. Biomech. Eng."},{"key":"B18","doi-asserted-by":"publisher","first-page":"3251","DOI":"10.1038\/s41598-022-07267-4","article-title":"Morphological variation in paediatric lower limb bones","volume":"12","author":"Carman","year":"2022","journal-title":"Sci. Rep."},{"key":"B19","doi-asserted-by":"publisher","first-page":"3333","DOI":"10.1016\/j.jbiomech.2007.05.004","article-title":"Validation of a voxel-based FE method for prediction of the uniaxial apparent modulus of human trabecular bone using macroscopic mechanical tests and nanoindentation","volume":"40","author":"Chevalier","year":"2007","journal-title":"J. Biomech."},{"key":"B20","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1177\/09544119241307793","article-title":"The role of high-resolution cartilage thickness distribution for contact mechanics predictions in the tibiofemoral joint","volume":"239","author":"Cooper","year":"2025","journal-title":"Proc. Inst. Mech. Eng. H."},{"key":"B21","doi-asserted-by":"publisher","first-page":"111383","DOI":"10.1016\/j.jbiomech.2022.111383","article-title":"Electromyography-driven model-based estimation of ankle torque and stiffness during dynamic joint rotations in perturbed and unperturbed conditions","volume":"145","author":"Cop","year":"2022","journal-title":"J. Biomech."},{"key":"B22","doi-asserted-by":"publisher","first-page":"987","DOI":"10.1109\/TBME.2023.3324485","article-title":"The simultaneous model-based estimation of joint, muscle, and tendon stiffness is highly sensitive to the tendon force-strain relationship","volume":"71","author":"Cop","year":"2024","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"B23","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1145\/29380.29864","article-title":"Minimizing multimodal functions of continuous variables with the \u201csimulated annealing\u201d algorithm\u2014","volume":"13","author":"Corana","year":"1987","journal-title":"ACM Trans. Math. Softw. (TOMS)"},{"key":"B24","doi-asserted-by":"publisher","first-page":"3486","DOI":"10.1109\/TNSRE.2024.3455262","article-title":"Real-time calibration-free musculotendon kinematics for neuromusculoskeletal models","volume":"32","author":"Cornish","year":"2024","journal-title":"IEEE Trans. Neural Syst. Rehabilitation Eng."},{"key":"B25","doi-asserted-by":"publisher","first-page":"112586","DOI":"10.1016\/j.jbiomech.2025.112586","article-title":"A calibrated EMG-Informed neuromusculoskeletal model can estimate hip and knee joint contact forces in cycling better than static optimisation","volume":"182","author":"Crossley","year":"2025","journal-title":"J. Biomech."},{"key":"B26","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/0021-9290(78)90045-3","article-title":"A biomechanical investigation of the human hip","volume":"11","author":"Crowninshield","year":"1978","journal-title":"J. Biomech."},{"key":"B27","doi-asserted-by":"publisher","first-page":"108132","DOI":"10.1016\/j.cmpb.2024.108132","article-title":"Sensitivity analysis of paediatric knee kinematics to the graft surgical parameters during anterior cruciate ligament reconstruction: a sequentially linked neuromusculoskeletal-finite element analysis","volume":"248","author":"Dastgerdi","year":"2024","journal-title":"Comput. Methods Programs Biomed."},{"key":"B28","doi-asserted-by":"publisher","first-page":"113017","DOI":"10.1016\/j.jbiomech.2025.113017","article-title":"Surgical efficacy in paediatric anterior cruciate ligament reconstruction: a comparative 3-case study of actual and simulated surgeries","volume":"193","author":"Dastgerdi","year":"","journal-title":"J. Biomech."},{"key":"B29","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1002\/ksa.12413","article-title":"Surgical parameters influence paediatric knee kinematics and cartilage stresses in anterior cruciate ligament reconstruction: navigating subject\u2010specific variability using neuromusculoskeletal\u2010finite element modelling analysis","volume":"33","author":"Dastgerdi","year":"","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"B30","doi-asserted-by":"publisher","first-page":"20116","DOI":"10.1038\/s41598-025-04260-5","article-title":"Effects of K-wire diameter and insertion angle on femoral bone medial closing-wedge osteotomies: a finite element study","volume":"15","author":"Dastgerdi","year":"","journal-title":"Sci. Rep."},{"key":"B149","doi-asserted-by":"publisher","first-page":"100929","DOI":"10.1016\/j.irbm.2026.100929","article-title":"The effects of surgical parameters on meniscal mechanics following anterior cruciate ligament reconstruction: an exploratory in-silico study","volume":"47","author":"Dastgerdi","year":"2026","journal-title":"IRBM"},{"key":"B31","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.clinbiomech.2019.12.011","article-title":"Increasing level of neuromusculoskeletal model personalisation to investigate joint contact forces in cerebral palsy: a twin case study","volume":"72","author":"Davico","year":"2020","journal-title":"Clin. Biomech. (Bristol)"},{"key":"B32","doi-asserted-by":"publisher","first-page":"1873","DOI":"10.1007\/s10237-022-01626-w","article-title":"Multi-level personalization of neuromusculoskeletal models to estimate physiologically plausible knee joint contact forces in children","volume":"21","author":"Davico","year":"2022","journal-title":"Biomech. Model. Mechanobiol."},{"key":"B33","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2021.696360","article-title":"Statistical-shape prediction of lower limb kinematics during cycling, squatting, lunging, and stepping\u2014are bone geometry predictors helpful?","volume":"9","author":"De Roeck","year":"2021","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B34","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1007\/BF00228972","article-title":"Wrist muscle activation patterns and stiffness associated with stable and unstable mechanical loads","volume":"86","author":"De Serres","year":"1991","journal-title":"Exp. Brain Res."},{"key":"B35","doi-asserted-by":"publisher","first-page":"1940","DOI":"10.1109\/tbme.2007.901024","article-title":"OpenSim: open-source software to create and analyze dynamic simulations of movement","volume":"54","author":"Delp","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"B36","doi-asserted-by":"publisher","first-page":"956","DOI":"10.1152\/japplphysiol.00662.2021","article-title":"Free achilles tendon strain during selected rehabilitation, locomotor, jumping, and landing tasks","volume":"132","author":"Devaprakash","year":"2022","journal-title":"J. Appl. Physiol. (1985)"},{"key":"B37","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/s0021-9290(02)00334-2","article-title":"Reflex muscle contractions can be elicited by valgus positional perturbations of the human knee","volume":"36","author":"Dhaher","year":"2003","journal-title":"J. Biomech."},{"key":"B38","doi-asserted-by":"publisher","first-page":"2698","DOI":"10.1152\/jn.00921.2004","article-title":"Neuromuscular reflexes contribute to knee stiffness during valgus loading","volume":"93","author":"Dhaher","year":"2005","journal-title":"J. Neurophysiol."},{"key":"B39","doi-asserted-by":"publisher","first-page":"913","DOI":"10.1007\/s42600-022-00227-x","article-title":"Computational analysis of the anterior cruciate ligament reconstruction under different graft configurations","volume":"38","author":"D\u00edaz-Cuadro","year":"2022","journal-title":"Res. Biomed. Eng."},{"key":"B40","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1186\/s12938-024-01321-0","article-title":"Experimental and computational evaluation of knee implant wear and creep under in vivo and ISO boundary conditions","volume":"23","author":"Dreyer","year":"2024","journal-title":"Biomed. Eng. Online"},{"key":"B41","doi-asserted-by":"publisher","first-page":"1141","DOI":"10.1243\/09544119JEIM799","article-title":"A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro tests","volume":"224","author":"Eberle","year":"2010","journal-title":"Proc. Inst. Mech. Eng. H."},{"key":"B42","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1016\/j.medengphy.2011.07.016","article-title":"Finite element prediction of surface strain and fracture strength at the distal radius","volume":"34","author":"Edwards","year":"2012","journal-title":"Med. Eng. Phys."},{"key":"B43","doi-asserted-by":"publisher","first-page":"108480","DOI":"10.1016\/j.cmpb.2024.108480","article-title":"Enhancing biomechanical outcomes in proximal femoral osteotomy through optimised blade plate sizing: a neuromusculoskeletal-informed finite element analysis","volume":"257","author":"Eghan-Acquah","year":"2024","journal-title":"Comput. Methods Programs Biomed."},{"key":"B44","doi-asserted-by":"publisher","first-page":"106908","DOI":"10.1016\/j.jmbbm.2025.106908","article-title":"Evaluation of boundary conditions for predicting femoral bone-implant mechanics during gait in the absence of comprehensive medical imaging","volume":"164","author":"Eghan-Acquah","year":"","journal-title":"J. Mech. Behav. Biomed. Mater"},{"key":"B45","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1007\/s00402-025-06058-6","article-title":"Comparative analysis of the effects of blade plate retention versus removal on paediatric bone remodelling following proximal femoral osteotomy","volume":"145","author":"Eghan-Acquah","year":"","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"B46","doi-asserted-by":"publisher","first-page":"071002","DOI":"10.1115\/1.4043346","article-title":"Deciphering the \u201cart\u201d in modeling and simulation of the knee joint: overall strategy","volume":"141","author":"Erdemir","year":"2019","journal-title":"J. Biomech. Eng."},{"key":"B47","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1109\/TNSRE.2020.3037411","article-title":"12 degrees of freedom muscle force driven fibril-reinforced poroviscoelastic finite element model of the knee joint","volume":"29","author":"Esrafilian","year":"2021","journal-title":"IEEE Trans. Neural Syst. Rehabilitation Eng."},{"key":"B48","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1109\/TBME.2024.3438272","article-title":"An automated and robust tool for musculoskeletal and finite element modeling of the knee joint","volume":"72","author":"Esrafilian","year":"2024","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"B49","volume-title":"Assessing the Credibility of Computational Modeling and Simulation in Medical Device Submissions: Guidance for Industry and Food and Drug Administration Staff","year":"2023"},{"key":"B50","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1007\/s00423-026-03997-5","article-title":"Incidence and risk factors for fixation failure of femoral neck fractures in adults: a single-center multifactorial analysis","volume":"411","author":"Feng","year":"2026","journal-title":"Langenbeck's Archives Surg."},{"key":"B51","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1123\/jab.2023-0079","article-title":"A narrative review of personalized musculoskeletal modeling using the physiome and musculoskeletal atlas projects","volume":"39","author":"Fernandez","year":"2023","journal-title":"J. Appl. Biomech."},{"key":"B52","doi-asserted-by":"publisher","first-page":"e0200952","DOI":"10.1371\/journal.pone.0200952","article-title":"On the internal reaction forces, energy absorption, and fracture in the hip during simulated sideways fall impact","volume":"13","author":"Fleps","year":"2018","journal-title":"PLoS One"},{"key":"B53","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1016\/j.gaitpost.2009.10.010","article-title":"Apparatus for monitoring load bearing rehabilitation exercises of a transfemoral amputee fitted with an osseointegrated fixation: a proof-of-concept study","volume":"31","author":"Frossard","year":"2010","journal-title":"Gait Posture"},{"key":"B54","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1007\/s11548-016-1519-8","article-title":"Estimation of attachment regions of hip muscles in CT image using muscle attachment probabilistic atlas constructed from measurements in eight cadavers","volume":"12","author":"Fukuda","year":"2017","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"B55","doi-asserted-by":"publisher","first-page":"1059003","DOI":"10.3389\/fbioe.2022.1059003","article-title":"Robust automatic hexahedral cartilage meshing framework enables population-based computational studies of the knee","volume":"10","author":"Gibbons","year":"2022","journal-title":"Front. Bioeng Biotechnol"},{"key":"B56","doi-asserted-by":"publisher","first-page":"e670","DOI":"10.1016\/S2665-9913(23)00232-1","article-title":"Global, regional, and national burden of other musculoskeletal disorders, 1990\u20132020, and projections to 2050: a systematic analysis of the global burden of disease study 2021","volume":"5","author":"Gill","year":"2023","journal-title":"Lancet Rheumatology"},{"key":"B57","doi-asserted-by":"publisher","first-page":"071001","DOI":"10.1115\/1.4045594","article-title":"Direct validation of human knee-joint contact mechanics derived from subject-specific finite-element models of the tibiofemoral and patellofemoral joints","volume":"142","author":"Gu","year":"2020","journal-title":"J. Biomech. Eng."},{"key":"B58","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.1111\/os.13674","article-title":"Long-term survival and predictors of failure of opening wedge high tibial osteotomy","volume":"15","author":"Guarino","year":"2023","journal-title":"Orthop. Surg."},{"key":"B59","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1007\/s11044-011-9289-0","article-title":"Method for determining musculotendon parameters in subject-specific musculoskeletal models of children developed from MRI data","volume":"28","author":"Hainisch","year":"2012","journal-title":"Multibody Syst. Dyn."},{"key":"B60","doi-asserted-by":"publisher","first-page":"3453","DOI":"10.1109\/tbme.2025.3569682","article-title":"Improving calibration of EMG-informed neuromusculoskeletal models through differentiable physics and muscle synergies","volume":"72","author":"Hambly","year":"","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"B61","first-page":"970","article-title":"Real-time continuous calibration of an EMG-informed neuromusculoskeletal model for assistive exoskeleton control","volume-title":"2025 International Conference on Rehabilitation Robotics (ICORR)","author":"Hambly","year":""},{"key":"B62","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1016\/j.jbiomech.2013.12.002","article-title":"Relationships of 35 lower limb muscles to height and body mass quantified using MRI","volume":"47","author":"Handsfield","year":"2014","journal-title":"J. Biomech."},{"key":"B63","doi-asserted-by":"publisher","first-page":"37707","DOI":"10.1038\/srep37707","article-title":"Predicting the location of the hip joint centres, impact of age group and sex","volume":"6","author":"Hara","year":"2016","journal-title":"Sci. Rep."},{"key":"B64","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1016\/j.jbiomech.2006.02.003","article-title":"Prediction of the hip joint centre in adults, children, and patients with cerebral palsy based on magnetic resonance imaging","volume":"40","author":"Harrington","year":"2007","journal-title":"J. Biomech."},{"key":"B65","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/S0021-9290(01)00158-0","article-title":"The fundamental problem of myoskeletal inverse dynamics and its implications","volume":"35","author":"Hatze","year":"2002","journal-title":"J. Biomech."},{"key":"B66","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1115\/1.1470171","article-title":"A finite element model of the human knee joint for the study of tibio-femoral contact","volume":"124","author":"Haut Donahue","year":"2002","journal-title":"J. Biomech. Eng."},{"key":"B67","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1016\/B978-0-12-824481-4.00026-3","article-title":"Finite element analysis in orthopedic biomechanics","volume-title":"Human Orthopaedic Biomechanics","author":"Heller","year":"2022"},{"key":"B68","doi-asserted-by":"publisher","first-page":"020905","DOI":"10.1115\/1.4029304","article-title":"Is my model good enough? Best practices for verification and validation of musculoskeletal models and simulations of movement","volume":"137","author":"Hicks","year":"2015","journal-title":"J. Biomech. Eng."},{"key":"B69","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1098\/rspb.1938.0050","article-title":"The heat of shortening and the dynamic constants of muscle","volume":"126","author":"Hill","year":"1938","journal-title":"Proc. R. Soc. Lond. Ser. B-Biological Sci."},{"key":"B70","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.jbiomech.2018.08.023","article-title":"Subject-specific calibration of neuromuscular parameters enables neuromusculoskeletal models to estimate physiologically plausible hip joint contact forces in healthy adults","volume":"80","author":"Hoang","year":"2018","journal-title":"J. Biomech."},{"key":"B71","doi-asserted-by":"publisher","first-page":"1165","DOI":"10.1152\/japplphysiol.01101.2018","article-title":"Individuals have unique muscle activation signatures as revealed during gait and pedaling","volume":"127","author":"Hug","year":"2019","journal-title":"J. Appl. Physiol."},{"key":"B72","first-page":"520","volume-title":"From Structure to Process, from Organ to Cell: Recent Developments of FE-analysis in Orthopaedic J. Biomech. Eng","author":"Huiskes","year":"1993"},{"key":"B73","doi-asserted-by":"publisher","first-page":"105402","DOI":"10.1016\/j.clinbiomech.2021.105402","article-title":"Generic scaled versus subject-specific models for the calculation of musculoskeletal loading in cerebral palsy gait: effect of personalized musculoskeletal geometry outweighs the effect of personalized neural control","volume":"87","author":"Kainz","year":"2021","journal-title":"Clin. Biomech. (Bristol, Avon)"},{"key":"B74","doi-asserted-by":"publisher","first-page":"2654","DOI":"10.1109\/jbhi.2024.3486538","article-title":"Advancing in silico clinical trials for regulatory adoption and innovation","volume":"29","author":"Karanasiou","year":"2025","journal-title":"IEEE J. Biomed. Health Inf."},{"key":"B75","doi-asserted-by":"publisher","first-page":"18328","DOI":"10.1038\/s41598-023-45408-5","article-title":"Validation and evaluation of subject-specific finite element models of the pediatric knee","volume":"13","author":"Karimi Dastgerdi","year":"2023","journal-title":"Sci. Rep."},{"key":"B76","doi-asserted-by":"publisher","first-page":"109348","DOI":"10.1016\/j.jbiomech.2019.109348","article-title":"Static optimization underestimates antagonist muscle activity at the glenohumeral joint: a musculoskeletal modeling study","volume":"97","author":"Kian","year":"2019","journal-title":"J. Biomech."},{"key":"B77","doi-asserted-by":"publisher","first-page":"110698","DOI":"10.1016\/j.jbiomech.2021.110698","article-title":"The effectiveness of EMG-Driven neuromusculoskeletal model calibration is task dependent","volume":"129","author":"Kian","year":"2021","journal-title":"J. Biomech."},{"key":"B78","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1007\/s10439-019-02207-2","article-title":"Anthropometric scaling of anatomical datasets for subject-specific musculoskeletal modelling of the shoulder","volume":"47","author":"Klemt","year":"2019","journal-title":"Ann. Biomed. Eng."},{"key":"B79","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1186\/s40634-016-0072-2","article-title":"Quantitative computed tomography (QCT) derived bone mineral density (BMD) in finite element studies: a review of the literature","volume":"3","author":"Knowles","year":"2016","journal-title":"J. Experimental Orthopaedics"},{"key":"B80","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1007\/s10237-006-0021-6","article-title":"Collagen network of articular cartilage modulates fluid flow and mechanical stresses in chondrocyte","volume":"5","author":"Korhonen","year":"2006","journal-title":"Biomech. Model. Mechanobiol."},{"key":"B81","doi-asserted-by":"publisher","first-page":"284","DOI":"10.2340\/17453674.2022.1997","article-title":"The effect of patient and prosthesis factors on revision rates after total knee replacement using a multi-registry meta-analytic approach","volume":"93","author":"Lewis","year":"2022","journal-title":"Acta Orthop."},{"key":"B82","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jbiomech.2017.04.038","article-title":"Three-dimensional data-tracking dynamic optimization simulations of human locomotion generated by direct collocation","volume":"59","author":"Lin","year":"2017","journal-title":"J. Biomech."},{"key":"B83","doi-asserted-by":"publisher","first-page":"532","DOI":"10.1038\/s43856-025-01238-2","article-title":"Patient-specific musculoskeletal modeling to enhance preoperative planning for pelvic fracture reduction","volume":"5","author":"Liu","year":"2025","journal-title":"Commun. Med."},{"key":"B84","doi-asserted-by":"publisher","first-page":"23259671221110191","DOI":"10.1177\/23259671221110191","article-title":"Revision rates after primary ACL reconstruction performed between 1969 and 2018: a systematic review and metaregression analysis","volume":"10","author":"Liukkonen","year":"2022","journal-title":"Orthop. J. Sports Med."},{"key":"B85","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1016\/s0021-9290(03)00010-1","article-title":"An EMG-Driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo","volume":"36","author":"Lloyd","year":"2003","journal-title":"J. Biomech."},{"key":"B86","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/23335432.2014.993706","article-title":"Scaling of musculoskeletal models from static and dynamic trials","volume":"2","author":"Lund","year":"2015","journal-title":"Int. Biomech."},{"key":"B87","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1016\/s0021-9290(03)00152-0","article-title":"A one-parameter neural activation to muscle activation model: estimating isometric joint moments from electromyograms","volume":"36","author":"Manal","year":"2003","journal-title":"J. Biomech."},{"key":"B88","doi-asserted-by":"publisher","first-page":"021014","DOI":"10.1115\/1.4023457","article-title":"An electromyogram-driven musculoskeletal model of the knee to predict in vivo joint contact forces during normal and novel gait patterns","volume":"135","author":"Manal","year":"2013","journal-title":"J. Biomech. Eng."},{"key":"B89","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1115\/1.1381396","article-title":"Kinematic analysis and synthesis of deterministic 3-2-1 locator schemes for machining fixtures","volume":"123","author":"Marin","year":"2000","journal-title":"J. Manuf. Sci. Eng."},{"key":"B90","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1016\/S1350-4533(97)00002-7","article-title":"Computer prediction of adaptive bone remodelling around noncemented femoral prostheses: the relationship between damage-based and strain-based algorithms","volume":"19","author":"McNamara","year":"1997","journal-title":"Med. Eng. Phys."},{"key":"B91","doi-asserted-by":"publisher","first-page":"111220","DOI":"10.1016\/j.jbiomech.2022.111220","article-title":"Electromyography measurements of the deep hip muscles do not improve estimates of hip contact force","volume":"141","author":"Meinders","year":"2022","journal-title":"J. Biomech."},{"key":"B92","doi-asserted-by":"publisher","first-page":"1447","DOI":"10.1016\/j.jbiomech.2003.12.017","article-title":"Moment arms and musculotendon lengths estimation for a three-dimensional lower-limb model","volume":"37","author":"Menegaldo","year":"2004","journal-title":"J. Biomech."},{"key":"B93","doi-asserted-by":"publisher","first-page":"110186","DOI":"10.1016\/j.jbiomech.2020.110186","article-title":"Automatic generation of personalised skeletal models of the lower limb from three-dimensional bone geometries","volume":"116","author":"Modenese","year":"2021","journal-title":"J. Biomech."},{"key":"B94","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.jbiomech.2015.11.006","article-title":"Estimation of musculotendon parameters for scaled and subject specific musculoskeletal models using an optimization technique","volume":"49","author":"Modenese","year":"2016","journal-title":"J. Biomech."},{"key":"B95","doi-asserted-by":"publisher","first-page":"024503","DOI":"10.1115\/1.4035866","article-title":"The role of computational modeling and simulation in the total product life cycle of peripheral vascular devices","volume":"11","author":"Morrison","year":"2017","journal-title":"J. Med. Device."},{"key":"B96","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1053\/joca.1998.0161","article-title":"The extracellular matrix, interstitial fluid and ions as a mechanical signal transducer in articular cartilage","volume":"7","author":"Mow","year":"1999","journal-title":"Osteoarthr. Cartil."},{"key":"B97","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1016\/j.knee.2020.01.010","article-title":"A novel approach for optimal graft positioning and tensioning in anterior cruciate ligament reconstructive surgery based on the finite element modeling technique","volume":"27","author":"Naghibi","year":"2020","journal-title":"Knee"},{"key":"B98","doi-asserted-by":"publisher","first-page":"1282","DOI":"10.1016\/j.jbiomech.2009.03.009","article-title":"Modular control of human walking: a simulation study","volume":"42","author":"Neptune","year":"2009","journal-title":"J. Biomech."},{"key":"B99","doi-asserted-by":"publisher","first-page":"2437","DOI":"10.1002\/jor.25912","article-title":"Effect of patient specificity on predicting knee cartilage degeneration in Obese adults: musculoskeletal finite\u2010element modeling of data from the CAROT trial","volume":"42","author":"Orozco","year":"2024","journal-title":"J. Orthop. Research\u00ae"},{"key":"B100","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1152\/jn.2002.88.2.991","article-title":"Short- and long-term changes in joint Co-Contraction associated with motor learning as revealed from surface EMG","volume":"88","author":"Osu","year":"2002","journal-title":"J. Neurophysiol."},{"key":"B101","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1115\/1.2401178","article-title":"The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs","volume":"129","author":"Papini","year":"2007","journal-title":"J. Biomech. Eng."},{"key":"B102","doi-asserted-by":"publisher","first-page":"5282","DOI":"10.1109\/jbhi.2022.3198145","article-title":"Toward A regulatory pathway for the use of in silico trials in the CE marking of medical devices","volume":"26","author":"Pappalardo","year":"2022","journal-title":"IEEE J. Biomed. Health Inf."},{"key":"B103","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1016\/0021-9290(81)90001-4","article-title":"An evaluation of the approaches of optimization models in the prediction of muscle forces during human gait","volume":"14","author":"Patriarco","year":"1981","journal-title":"J. Biomech."},{"key":"B104","doi-asserted-by":"publisher","first-page":"3929","DOI":"10.1016\/j.jbiomech.2015.09.021","article-title":"CEINMS: a toolbox to investigate the influence of different neural control solutions on the prediction of muscle excitation and joint moments during dynamic motor tasks","volume":"48","author":"Pizzolato","year":"2015","journal-title":"J. Biomech."},{"key":"B105","doi-asserted-by":"publisher","first-page":"1399","DOI":"10.1007\/s10439-025-03713-2","article-title":"EMG-informed neuromusculoskeletal simulations increase the accuracy of the estimation of knee joint contact forces during sub-optimal level walking","volume":"53","author":"Princelle","year":"2025","journal-title":"Ann. Biomed. Eng."},{"key":"B106","doi-asserted-by":"publisher","first-page":"3599","DOI":"10.1038\/s41598-022-07541-5","article-title":"A muscle synergy-based method to estimate muscle activation patterns of children with cerebral palsy using data collected from typically developing children","volume":"12","author":"Rabbi","year":"2022","journal-title":"Sci. Rep."},{"key":"B107","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.1007\/s10237-024-01825-7","article-title":"Muscle synergy-informed neuromusculoskeletal modelling to estimate knee contact forces in children with cerebral palsy","volume":"23","author":"Rabbi","year":"2024","journal-title":"Biomech. Model. Mechanobiol."},{"key":"B108","doi-asserted-by":"publisher","first-page":"2068","DOI":"10.1109\/tbme.2016.2586891","article-title":"Full-body musculoskeletal model for muscle-driven simulation of human gait","volume":"63","author":"Rajagopal","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"B109","doi-asserted-by":"publisher","first-page":"111987","DOI":"10.1016\/j.jbiomech.2024.111987","article-title":"Electromyography-driven musculoskeletal models with time-varying fatigue dynamics improve Lumbosacral joint moments during lifting","volume":"164","author":"Refai","year":"2024","journal-title":"J. Biomech."},{"key":"B110","doi-asserted-by":"publisher","first-page":"379","DOI":"10.2174\/1874325001105010379","article-title":"Differences in external and internal cortical strain with prosthesis in the femur","volume":"5","author":"Reikeras","year":"2011","journal-title":"Open Orthopaedics Journal"},{"key":"B111","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1016\/j.gaitpost.2007.07.012","article-title":"Uncertainties in inverse dynamics solutions: a comprehensive analysis and an application to gait","volume":"27","author":"Riemer","year":"2008","journal-title":"Gait Posture"},{"key":"B112","doi-asserted-by":"publisher","first-page":"8044","DOI":"10.1038\/s41598-022-11601-1","article-title":"Evaluation of anterior cruciate ligament surgical reconstruction through finite element analysis","volume":"12","author":"Risvas","year":"2022","journal-title":"Sci. Rep."},{"key":"B113","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/j.clinbiomech.2020.01.017","article-title":"Load response of an osseointegrated implant used in the treatment of unilateral transfemoral amputation: an early implant loosening case study","volume":"73","author":"Robinson","year":"2020","journal-title":"Clin. Biomech. (Bristol, Avon)"},{"key":"B114","doi-asserted-by":"publisher","first-page":"106074","DOI":"10.1016\/j.clinbiomech.2023.106074","article-title":"Influence of different calibration methods on surface electromyography-informed musculoskeletal models with few input signals","volume":"109","author":"Romanato","year":"2023","journal-title":"Clin. Biomech. (Bristol, Avon)"},{"key":"B115","doi-asserted-by":"publisher","first-page":"e52618","DOI":"10.1371\/journal.pone.0052618","article-title":"EMG-driven forward-dynamic estimation of muscle force and joint moment about multiple degrees of freedom in the human lower extremity","volume":"7","author":"Sartori","year":"","journal-title":"PLoS One"},{"key":"B116","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1016\/j.jbiomech.2011.10.040","article-title":"Estimation of musculotendon kinematics in large musculoskeletal models using multidimensional B-splines","volume":"45","author":"Sartori","year":"","journal-title":"J. Biomech."},{"key":"B117","doi-asserted-by":"publisher","first-page":"79","DOI":"10.3389\/fncom.2013.00079","article-title":"A musculoskeletal model of human locomotion driven by a low dimensional set of impulsive excitation primitives","volume":"7","author":"Sartori","year":"2013","journal-title":"Front. Comput. Neurosci."},{"key":"B118","doi-asserted-by":"publisher","first-page":"3613","DOI":"10.1016\/j.jbiomech.2014.10.009","article-title":"Hybrid neuromusculoskeletal modeling to best track joint moments using a balance between muscle excitations derived from electromyograms and optimization","volume":"47","author":"Sartori","year":"2014","journal-title":"J. Biomech."},{"key":"B119","doi-asserted-by":"publisher","first-page":"2509","DOI":"10.1152\/jn.00989.2014","article-title":"Modeling and simulating the neuromuscular mechanisms regulating ankle and knee joint stiffness during human locomotion","volume":"114","author":"Sartori","year":"2015","journal-title":"J. Neurophysiol."},{"key":"B120","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1123\/jab.2023-0114","article-title":"A digital twin framework for precision neuromusculoskeletal health care: extension upon industrial standards","volume":"39","author":"Saxby","year":"2023","journal-title":"J. Appl. Biomech."},{"key":"B121","doi-asserted-by":"publisher","first-page":"1018","DOI":"10.1002\/art.22889","article-title":"Influences on knee movement strategies during walking in persons with medial knee osteoarthritis","volume":"57","author":"Schmitt","year":"2007","journal-title":"Arthritis Rheum."},{"key":"B122","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1115\/1.1894388","article-title":"Evaluation of a particle swarm algorithm for biomechanical optimization","volume":"127","author":"Schutte","year":"2005","journal-title":"J. Biomech. Eng."},{"key":"B123","doi-asserted-by":"publisher","first-page":"e1006223","DOI":"10.1371\/journal.pcbi.1006223","article-title":"OpenSim: simulating musculoskeletal dynamics and neuromuscular control to study human and animal movement","volume":"14","author":"Seth","year":"2018","journal-title":"PLoS Comput. Biol."},{"key":"B124","doi-asserted-by":"publisher","first-page":"107002","DOI":"10.1016\/j.cmpb.2022.107002","article-title":"Development of predictive statistical shape models for paediatric lower limb bones","volume":"225","author":"Shi","year":"2022","journal-title":"Comput. Methods Programs Biomed."},{"key":"B125","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/j.jbiomech.2018.10.008","article-title":"Can altered neuromuscular coordination restore soft tissue loading patterns in anterior cruciate ligament and menisci deficient knees during walking?","volume":"82","author":"Smith","year":"2019","journal-title":"J. Biomech."},{"key":"B126","doi-asserted-by":"publisher","first-page":"2318","DOI":"10.1016\/j.jbiomech.2006.10.038","article-title":"Physiologically based boundary conditions in finite element modelling","volume":"40","author":"Speirs","year":"2007","journal-title":"J. Biomech."},{"key":"B127","doi-asserted-by":"publisher","first-page":"973","DOI":"10.1016\/j.medengphy.2006.10.014","article-title":"The material mapping strategy influences the accuracy of CT-based finite element models of bones: an evaluation against experimental measurements","volume":"29","author":"Taddei","year":"2007","journal-title":"Med. Eng. Phys."},{"key":"B128","doi-asserted-by":"publisher","first-page":"220","DOI":"10.5435\/JAAOS-D-14-00332","article-title":"Preoperative planning in primary total knee arthroplasty","volume":"24","author":"Tanzer","year":"2016","journal-title":"JAAOS - J. Am. Acad. Orthop. Surg."},{"key":"B129","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1007\/BF00253623","article-title":"Differences in the activation of M. Biceps brachii in the control of slow isotonic movements and isometric contractions","volume":"76","author":"Tax","year":"1989","journal-title":"Exp. Brain Res."},{"key":"B130","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1007\/BF02423505","article-title":"Differences in coordination of elbow flexor muscles in force tasks and in movement tasks","volume":"81","author":"Tax","year":"1990","journal-title":"Exp. Brain Res."},{"key":"B131","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1016\/j.jbiomech.2014.12.019","article-title":"Four decades of finite element analysis of orthopaedic devices: where are we now and what are the opportunities?","volume":"48","author":"Taylor","year":"2015","journal-title":"J. Biomech."},{"key":"B132","doi-asserted-by":"publisher","first-page":"1107","DOI":"10.1016\/j.jbiomech.2005.02.010","article-title":"Using computed muscle control to generate forward dynamic simulations of human walking from experimental data","volume":"39","author":"Thelen","year":"2006","journal-title":"J. Biomech."},{"key":"B133","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1016\/s0021-9290(02)00432-3","article-title":"Generating dynamic simulations of movement using computed muscle control","volume":"36","author":"Thelen","year":"2003","journal-title":"J. Biomech."},{"key":"B134","doi-asserted-by":"publisher","first-page":"968","DOI":"10.1186\/s13018-025-06311-z","article-title":"Femoral fracture risk in transfemoral amputees with bone-anchored prosthetic limbs during activities of daily living","volume":"20","author":"Tiew","year":"2025","journal-title":"J. Orthop. Surg. Res."},{"key":"B135","doi-asserted-by":"publisher","first-page":"9842","DOI":"10.1038\/s41598-022-13386-9","article-title":"Muscle coordination retraining inspired by musculoskeletal simulations reduces knee contact force","volume":"12","author":"Uhlrich","year":"2022","journal-title":"Sci. Rep."},{"key":"B136","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1007\/BFb0031482","article-title":"Synergism in the control of force and movement of the forearm","volume":"118","author":"van der Gon","year":"1991","journal-title":"Rev. Physiol. Biochem. Pharmacol."},{"key":"B137","doi-asserted-by":"publisher","first-page":"106152","DOI":"10.1016\/j.clinbiomech.2023.106152","article-title":"Predictive simulations identify potential neuromuscular contributors to idiopathic toe walking","volume":"111","author":"Veerkamp","year":"2024","journal-title":"Clin. Biomech. (Bristol)"},{"key":"B138","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1109\/TNSRE.2014.2337956","article-title":"Static load bearing exercises of individuals with transfemoral amputation fitted with an osseointegrated implant: reliability of kinetic data","volume":"23","author":"Vertriest","year":"2015","journal-title":"IEEE Trans. Neural Syst. Rehabilitation Eng."},{"key":"B139","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1177\/0309364616640949","article-title":"Static load bearing exercises of individuals with transfemoral amputation fitted with an osseointegrated implant: loading compliance","volume":"41","author":"Vertriest","year":"2017","journal-title":"Prosthet. Orthot. Int."},{"key":"B140","doi-asserted-by":"publisher","first-page":"021031","DOI":"10.1115\/1.4026428","article-title":"Muscle synergies may improve optimization prediction of knee contact forces during walking","volume":"136","author":"Walter","year":"2014","journal-title":"J. Biomech. Eng."},{"key":"B141","doi-asserted-by":"crossref","DOI":"10.1007\/978-0-387-92897-5_1277","article-title":"Contact mechanics studies between the articulating surfaces of artificial hip joints","volume-title":"Encyclopedia of Tribology","author":"Wang","year":"2013"},{"key":"B142","doi-asserted-by":"publisher","first-page":"1682","DOI":"10.1016\/j.jbiomech.2008.03.008","article-title":"Evaluation of different analytical methods for subject-specific scaling of musculotendon parameters","volume":"41","author":"Winby","year":"2008","journal-title":"J. Biomech."},{"key":"B143","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1007\/BF02584437","article-title":"An improved muscle-reflex actuator for use in large-scale neuromusculoskeletal models","volume":"23","author":"Winters","year":"1995","journal-title":"Ann. Biomed. Eng."},{"key":"B144","doi-asserted-by":"publisher","first-page":"112890","DOI":"10.1016\/j.jbiomech.2025.112890","article-title":"Muscle forces and powers during sprint cycling at optimal cadence","volume":"191","author":"Worsey","year":"2025","journal-title":"J. Biomech."},{"key":"B145","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1111\/os.13980","article-title":"Model properties and clinical application in the finite element analysis of knee joint: a review","volume":"16","author":"Yan","year":"2024","journal-title":"Orthop. Surg."},{"key":"B146","doi-asserted-by":"publisher","first-page":"1239","DOI":"10.1007\/s10237-019-01243-0","article-title":"Rapid muscle volume prediction using anthropometric measurements and population-derived statistical models","volume":"19","author":"Yeung","year":"2020","journal-title":"Biomech. Model Mechanobiol."},{"key":"B147","first-page":"359","article-title":"Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control","volume":"17","author":"Zajac","year":"1989","journal-title":"Crit. Rev. Biomed. Eng."},{"key":"B148","doi-asserted-by":"publisher","first-page":"3875","DOI":"10.1016\/j.jbiomech.2016.10.021","article-title":"Lower limb estimation from sparse landmarks using an articulated shape model","volume":"49","author":"Zhang","year":"2016","journal-title":"J. Biomech."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2026.1875782\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T06:40:29Z","timestamp":1788417629000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2026.1875782\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,3]]},"references-count":149,"alternative-id":["10.3389\/fbioe.2026.1875782"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2026.1875782","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,3]]},"article-number":"1875782"}}