{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T09:00:14Z","timestamp":1790586014095,"version":"4.1.0"},"reference-count":67,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T00:00:00Z","timestamp":1790553600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p>\n                    The clinical translation of endovascular implants and new therapeutics for aortic aneurysms depend broadly on the reliability of the experimental testing models utilized.\n                    <jats:italic>In vivo<\/jats:italic>\n                    models present serious ethical and logistical limitations. Conversely,\n                    <jats:italic>in vitro<\/jats:italic>\n                    modelling is a high fidelity, human relevant approach, with carefully controlled environments and quicker clinical translation. Using the systematic literature search method, literature was screened for the various types of\n                    <jats:italic>in vitro<\/jats:italic>\n                    platforms used in aneurysm studies and classified into three main categories: (1) 3D-printed replicas, (2) computational fluid dynamics models, and (3) tissue mimicking hydrogel phantoms. A critical evaluation of material properties, fabrication techniques and experimental applications has shown that material compliance is crucial to reproduce physiological wall motion, and hydrogels provide outstanding properties for multi-modal imaging validation (Ultrasound, MRI and computed tomography) and for mimicking the structure of tissues. Moreover, the use of experimental flow visualization techniques also helps to overcome the challenges of disturbed hemodynamic patterns characterization. While several\n                    <jats:italic>in vitro<\/jats:italic>\n                    aneurysm models have achieved luminal endothelialization, the biomimetic incorporation of arterial smooth muscle cells together with endothelial cells in tissue-engineered aortic constructs is lacking in the literature and is an important future area of vascular research. To sum up, this review synthesizes these different\n                    <jats:italic>in vitro<\/jats:italic>\n                    modalities and their clinical translational potential, providing a clearer framework for future implant and therapeutic evaluation.\n                  <\/jats:p>","DOI":"10.3389\/fbioe.2026.1918602","type":"journal-article","created":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T08:42:38Z","timestamp":1790584958000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["In vitro aneurysm models: a comprehensive review of 3D-printed, computational, and hydrogel platforms"],"prefix":"10.3389","volume":"14","author":[{"given":"Saurav Ranjan","family":"Mohapatra","sequence":"first","affiliation":[{"name":"Department of Vascular Surgery, University Hospital RWTH Aachen, RWTH Aachen University","place":["Aachen, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Apel","sequence":"additional","affiliation":[{"name":"Department of Biohybrid and Medical Textiles Institute of Applied Medical Engineering, RWTH Aachen University","place":["Aachen, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Panagiotis","family":"Doukas","sequence":"additional","affiliation":[{"name":"Department of Vascular Surgery, University Hospital RWTH Aachen, RWTH Aachen University","place":["Aachen, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Gombert","sequence":"additional","affiliation":[{"name":"Department of Vascular Surgery, University Hospital RWTH Aachen, RWTH Aachen University","place":["Aachen, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Jockenh\u00f6vel","sequence":"additional","affiliation":[{"name":"Department of Biohybrid and Medical Textiles Institute of Applied Medical Engineering, RWTH Aachen University","place":["Aachen, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Uhl","sequence":"additional","affiliation":[{"name":"Department of Vascular Surgery, University Hospital RWTH Aachen, RWTH Aachen University","place":["Aachen, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,9,28]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"e69310","DOI":"10.7554\/eLife.69310","article-title":"Aorta smooth muscle-on-a-chip reveals impaired mitochondrial dynamics as a therapeutic target for aortic aneurysm in bicuspid aortic valve disease","volume":"10","author":"Abudupataer","year":"2021","journal-title":"Elife"},{"key":"B2","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1186\/s12938-015-0032-6","article-title":"Aortic dissection simulation models for clinical support: fluid-structure interaction vs. rigid wall models","volume":"14","author":"Alimohammadi","year":"2015","journal-title":"Biomed. Eng. Online"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1141623","DOI":"10.3389\/fcvm.2023.1141623","article-title":"Fabrication of deformable patient-specific AAA models by material casting techniques","volume":"10","author":"Antonuccio","year":"2023","journal-title":"Front. Cardiovasc. Med."},{"key":"B4","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1007\/s10237-016-0853-7","article-title":"Wall shear stress exposure time: a Lagrangian measure of near-wall stagnation and concentration in cardiovascular flows","volume":"16","author":"Arzani","year":"2017","journal-title":"Biomech. Model. Mechanobiol."},{"key":"B5","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1007\/s13239-017-0312-3","article-title":"Pulsatile flow leads to intimal flap motion and flow reversal in an in vitro model of type B aortic dissection","volume":"8","author":"Birjiniuk","year":"2017","journal-title":"Cardiovasc. Eng. Technol."},{"key":"B6","doi-asserted-by":"publisher","first-page":"230563","DOI":"10.1098\/rsos.230563","article-title":"The effect of stent graft curvature on the hemodynamic displacement force after abdominal aortic aneurysm endovascular repair","volume":"10","author":"Brand","year":"2023","journal-title":"R. Soc. Open Sci."},{"key":"B7","doi-asserted-by":"publisher","first-page":"1918","DOI":"10.2174\/1381612826666200622132440","article-title":"3D printing in modern cardiology","volume":"27","author":"Celi","year":"2021","journal-title":"Curr. Pharm. Des."},{"key":"B8","doi-asserted-by":"publisher","first-page":"81001","DOI":"10.1115\/1.4024275","article-title":"Fluid-structure interaction modeling of abdominal aortic aneurysms: the impact of patient-specific inflow conditions and fluid\/solid coupling","volume":"135","author":"Chandra","year":"2013","journal-title":"J. Biomech. Eng."},{"key":"B9","doi-asserted-by":"publisher","first-page":"627877","DOI":"10.3389\/fbioe.2021.627877","article-title":"Engineering a human pluripotent stem cell-based in vitro microphysiological system for studying the metformin response in aortic smooth muscle cells","volume":"9","author":"Chen","year":"2021","journal-title":"Front Bioeng Biotechnol."},{"key":"B10","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1089\/3dp.2013.0010","article-title":"3D-printed tissue-mimicking phantoms for medical imaging and computational validation applications","volume":"1","author":"Cloonan","year":"2014","journal-title":"3D Print. Addit. Manuf."},{"key":"B11","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1136\/jnnp.22.4.259","article-title":"Some observations on the pathogenesis and natural history of intracranial aneurysms","volume":"22","author":"Crawford","year":"1959","journal-title":"J. Neurol. Neurosurg. Psychiatry"},{"key":"B12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/admt.202502610","article-title":"Additive manufacturing of patient-specific intracranial aneurysm cell culture models","volume":"11","author":"de Nys","year":"2025","journal-title":"bioRxiv"},{"key":"B13","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1007\/s00348-016-2263-0","article-title":"3D analysis of vortical structures in an abdominal aortic aneurysm by stereoscopic PIV","volume":"57","author":"Deplano","year":"2016","journal-title":"Exp. Fluids"},{"key":"B14","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1007\/s13239-025-00810-0","article-title":"Development and characteristics of a dual-layered vascular phantom","volume":"17","author":"Elmer","year":"2025","journal-title":"Cardiovasc. Eng. Technol."},{"key":"B15","doi-asserted-by":"publisher","first-page":"092002","DOI":"10.1088\/1361-6501\/ac75b0","article-title":"Flow visualization: state-of-the-art development of micro-particle image velocimetry","volume":"33","author":"Etminan","year":"2022","journal-title":"Meas. Sci. Technol."},{"key":"B16","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1115\/1.1543991","article-title":"The effect of asymmetry in abdominal aortic aneurysms under physiologically realistic pulsatile flow conditions","volume":"125","author":"Finol","year":"2003","journal-title":"J. Biomech. Eng."},{"key":"B17","doi-asserted-by":"publisher","first-page":"2200051","DOI":"10.1002\/mabi.202200051","article-title":"Recent development of conductive hydrogels for tissue engineering: review and perspective","volume":"22","author":"Gao","year":"","journal-title":"Macromol. Biosci."},{"key":"B18","doi-asserted-by":"publisher","first-page":"244","DOI":"10.12945\/j.aorta.2013.13-052","article-title":"Lessons from animal models of arterial aneurysm","volume":"1","author":"Gertz","year":"","journal-title":"Aorta (Stamford)"},{"key":"B19","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1007\/BF00593516","article-title":"In vitro study of haemodynamics in a giant saccular aneurysm model: influence of flow dynamics in the parent vessel and effects of coil embolisation","volume":"36","author":"Gobin","year":"2014","journal-title":"Neuroradiology"},{"key":"B20","doi-asserted-by":"publisher","first-page":"100245","DOI":"10.1016\/j.pacs.2021.100245","article-title":"Polyacrylamide hydrogel phantoms for performance evaluation of multispectral photoacoustic imaging systems","volume":"22","author":"Hariri","year":"2021","journal-title":"Photoacoustics"},{"key":"B21","doi-asserted-by":"publisher","first-page":"2948","DOI":"10.1109\/TBME.2024.3403799","article-title":"Quantification of cervical elasticity during pregnancy based on transvaginal ultrasound imaging and stress measurement","volume":"71","author":"Hu","year":"2024","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"B22","doi-asserted-by":"publisher","first-page":"eabb3308","DOI":"10.1126\/sciadv.abb3308","article-title":"Examining metastatic behavior within 3D bioprinted vasculature for the validation of a 3D computational flow model","volume":"6","author":"Hynes","year":"2020","journal-title":"Sci. Adv."},{"key":"B23","doi-asserted-by":"publisher","first-page":"015021","DOI":"10.1088\/1758-5090\/abbb9b","article-title":"Three-dimensional bioprinting of aneurysm-bearing tissue structure for endovascular deployment of embolization coils","volume":"13","author":"Jang","year":"2020","journal-title":"Biofabrication"},{"key":"B24","doi-asserted-by":"publisher","first-page":"100424","DOI":"10.1016\/j.medntd.2025.100424","article-title":"In-vitro study of arterial vessel stiffness on wall shear stress reversal under physiological pulsatile flow conditions","volume":"29","author":"Jiao","year":"2026","journal-title":"Med. Nov. Technol. Devices"},{"key":"B25","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1016\/j.ultrasmedbio.2025.10.006","article-title":"Method for developing tissue-mimicking ultrasound imaging phantoms of organs using polyvinyl alcohol and 3-D printed moulds","volume":"52","author":"Kumar","year":"2026","journal-title":"Ultrasound Med. Biol."},{"key":"B26","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1227\/neu.0000000000003189","article-title":"Force characterization of intracranial endovascular embolization: coil type, microcatheter placement, and insertion rate","volume":"96","author":"Lamano","year":"2025","journal-title":"Neurosurgery"},{"key":"B27","doi-asserted-by":"publisher","first-page":"6837","DOI":"10.3390\/jcm12216837","article-title":"Systematic review and meta-analysis of the incidence of rupture, repair, and death of small and large abdominal aortic aneurysms under surveillance","volume":"12","author":"Leone","year":"2023","journal-title":"J. Clin. Med."},{"key":"B28","doi-asserted-by":"publisher","first-page":"1611","DOI":"10.1007\/s11548-022-02612-4","article-title":"A patient-specific multi-modality abdominal aortic aneurysm imaging phantom","volume":"17","author":"Little","year":"2022","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"B29","doi-asserted-by":"publisher","first-page":"104080","DOI":"10.1016\/j.ebiom.2022.104080","article-title":"Patient-derived microphysiological model identifies the therapeutic potential of metformin for thoracic aortic aneurysm","volume":"81","author":"Ma","year":"2022","journal-title":"EBioMedicine"},{"key":"B30","doi-asserted-by":"publisher","first-page":"e61344","DOI":"10.3791\/61344","article-title":"Patient-specific polyvinyl alcohol phantom fabrication with ultrasound and x-ray contrast for brain tumor surgery planning","author":"Mackle","year":"2020","journal-title":"J. Vis. Exp."},{"key":"B31","doi-asserted-by":"publisher","first-page":"105930","DOI":"10.1016\/j.jmbbm.2023.105930","article-title":"3D printed biomedical devices and their applications: a review on state-of-the-art technologies, existing challenges, and future perspectives","volume":"143","author":"Mamo","year":"2023","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"B32","doi-asserted-by":"publisher","first-page":"015033","DOI":"10.1088\/1361-6560\/aa9e2c","article-title":"Anatomically realistic ultrasound phantoms using gel wax with 3D printed moulds","volume":"63","author":"Maneas","year":"","journal-title":"Phys. Med. Biol."},{"key":"B33","doi-asserted-by":"publisher","first-page":"1151","DOI":"10.1364\/boe.9.001151","article-title":"Gel wax-based tissue-mimicking phantoms for multispectral photoacoustic imaging","volume":"9","author":"Maneas","year":"","journal-title":"Biomed. Opt. Express"},{"key":"B34","doi-asserted-by":"publisher","first-page":"111004","DOI":"10.1115\/1.4005416","article-title":"Stereoscopically observed deformations of a compliant abdominal aortic aneurysm model","volume":"133","author":"Meyer","year":"2011","journal-title":"J. Biomech. Eng."},{"key":"B35","doi-asserted-by":"publisher","first-page":"1439","DOI":"10.1007\/s10439-025-03717-y","article-title":"Vascular flow phantom of A cohort-based averaged abdominal aortic aneurysm: design, fabrication and characterization","volume":"53","author":"Mirgolbabaee","year":"","journal-title":"Ann. Biomed. Eng."},{"key":"B36","doi-asserted-by":"publisher","first-page":"2223","DOI":"10.1177\/15266028231219988","article-title":"Ultrasound particle image velocimetry to investigate potential hemodynamic causes of limb thrombosis after endovascular aneurysm repair with the anaconda device","volume":"32","author":"Mirgolbabaee","year":"","journal-title":"J. Endovasc. Ther."},{"key":"B37","doi-asserted-by":"publisher","first-page":"e57984","DOI":"10.3791\/57984","article-title":"Manufacturing abdominal aorta hydrogel tissue-mimicking phantoms for ultrasound elastography validation","author":"Mix","year":"2018","journal-title":"J. Vis. Exp."},{"key":"B38","doi-asserted-by":"publisher","first-page":"1169","DOI":"10.1007\/s13770-022-00482-0","article-title":"From in vitro to perioperative vascular tissue engineering: shortening production time by traceable textile-reinforcement","volume":"19","author":"Mohapatra","year":"2022","journal-title":"Tissue Eng. Regen. Med."},{"key":"B39","doi-asserted-by":"publisher","first-page":"871","DOI":"10.1016\/j.jvir.2023.01.008","article-title":"Mechanical properties of a 3 dimensional\u2013printed transparent flexible resin used for vascular model simulation compared with those of porcine arteries","volume":"34","author":"Morita","year":"2023","journal-title":"J. Vasc. Interv. Radiol."},{"key":"B40","doi-asserted-by":"publisher","first-page":"105575","DOI":"10.1016\/j.jmbbm.2022.105575","article-title":"Techniques for characterizing mechanical properties of soft tissues","volume":"138","author":"Navindaran","year":"2023","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"B41","doi-asserted-by":"publisher","first-page":"e155","DOI":"10.1055\/s-0041-1728790","article-title":"Thrombin\u2013fibrinogen in vitro flow model of thrombus growth in cerebral aneurysms","volume":"5","author":"Ngoepe","year":"2021","journal-title":"TH Open"},{"key":"B42","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1186\/s12938-023-01179-8","article-title":"Integrated particle image velocimetry and fluid\u2013structure interaction analysis for patient-specific abdominal aortic aneurysm studies","volume":"22","author":"\u00d6zcan","year":"2023","journal-title":"Biomed. Eng. Online"},{"key":"B43","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/j.jmbbm.2014.11.005","article-title":"Determining the influence of calcification on the failure properties of abdominal aortic aneurysm (AAA) tissue","volume":"42","author":"O\u2019Leary","year":"2015","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"B44","doi-asserted-by":"publisher","first-page":"1485267","DOI":"10.3389\/fcvm.2024.1485267","article-title":"Application of three-dimensional printing in the planning and execution of aortic aneurysm repair","volume":"11","author":"Patel","year":"2024","journal-title":"Front. Cardiovasc. Med."},{"key":"B45","doi-asserted-by":"publisher","first-page":"2252","DOI":"10.1039\/c3lc41393d","article-title":"Microfluidic platforms for mechanobiology","volume":"13","author":"Polacheck","year":"2013","journal-title":"Lab. Chip"},{"key":"B46","doi-asserted-by":"publisher","first-page":"619858","DOI":"10.3389\/fbioe.2020.619858","article-title":"Pulsatile flow-induced fatigue-resistant photopolymerizable hydrogels for the treatment of intracranial aneurysms","volume":"8","author":"Poupart","year":"2021","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B47","doi-asserted-by":"publisher","first-page":"2105783","DOI":"10.1002\/advs.202105783","article-title":"Monitoring the remodeling of biohybrid tissue-engineered vascular grafts by multimodal molecular imaging","volume":"9","author":"Rama","year":"","journal-title":"Adv. Sci."},{"key":"B48","doi-asserted-by":"publisher","first-page":"1577","DOI":"10.1002\/jbm.a.35271","article-title":"Design and biocompatibility of endovascular aneurysm filling devices","volume":"103","author":"Rodriguez","year":"2015","journal-title":"J. Biomed. Mater. Res. - Part A"},{"key":"B49","doi-asserted-by":"publisher","first-page":"1505","DOI":"10.1016\/j.medengphy.2016.09.010","article-title":"Anisotropic abdominal aortic aneurysm replicas with biaxial material characterization","volume":"38","author":"Ruiz de Galarreta","year":"2016","journal-title":"Med. Eng. Phys."},{"key":"B50","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1016\/j.jbiomech.2017.04.001","article-title":"A methodology for developing anisotropic AAA phantoms via additive manufacturing","volume":"57","author":"Ruiz de Galarreta","year":"2017","journal-title":"J. Biomech."},{"key":"B51","doi-asserted-by":"publisher","first-page":"111","DOI":"10.3389\/fbioe.2019.00111","article-title":"Biomechanical investigation of disturbed hemodynamics-induced tissue degeneration in abdominal aortic aneurysms using computational and experimental techniques","volume":"7","author":"Salman","year":"2019","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B52","doi-asserted-by":"publisher","first-page":"1021","DOI":"10.1177\/0271678X19854640","article-title":"What does computational fluid dynamics tell us about intracranial aneurysms? A meta-analysis and critical review","volume":"40","author":"Saqr","year":"2020","journal-title":"J. Cereb. Blood Flow. Metab."},{"key":"B53","doi-asserted-by":"publisher","first-page":"105156","DOI":"10.1016\/j.jmbbm.2022.105156","article-title":"Assessing the aneurysm occlusion efficacy of a shear-thinning biomaterial in a 3D-printed model","volume":"130","author":"Schroeder","year":"2022","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"B54","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1186\/1475-925X-4-64","article-title":"Fluid-structure interaction in abdominal aortic aneurysms: effects of asymmetry and wall thickness","volume":"4","author":"Scotti","year":"2005","journal-title":"Biomed. Eng. Online"},{"key":"B55","doi-asserted-by":"publisher","first-page":"e35465","DOI":"10.1002\/jbm.b.35465","article-title":"Application of 3D printing to create an in vitro aneurysm rupture model","volume":"112","author":"Sodawalla","year":"2024","journal-title":"J. Biomed. Mater. Res. - Part B Appl. Biomater."},{"key":"B56","doi-asserted-by":"publisher","first-page":"121","DOI":"10.5220\/0011652100003414","article-title":"In Vitro Flow Study in an Intracranial Aneurysm Biomodel Manufactured by Additive Manufacturing","volume":"1","author":"Souza","year":"2023","journal-title":"Proceedings of the 16th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2023)"},{"key":"B57","doi-asserted-by":"publisher","first-page":"915","DOI":"10.1016\/j.expthermflusci.2010.02.008","article-title":"Steady and unsteady flow within an axisymmetric tube dilatation","volume":"34","author":"Stamatopoulos","year":"2010","journal-title":"Exp. Therm. Fluid Sci."},{"key":"B58","doi-asserted-by":"publisher","first-page":"051004","DOI":"10.1115\/1.4049894","article-title":"Design, development, and temporal evaluation of a magnetic resonance imaging-compatible in vitro circulation model using a compliant abdominal aortic aneurysm phantom","volume":"143","author":"Thirugnanasambandam","year":"2021","journal-title":"J. Biomech. Eng."},{"key":"B59","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1080\/03091900110057806","article-title":"Mechanical properties of abdominal aortic aneurysm wall","volume":"25","author":"Thubrikar","year":"2001","journal-title":"J. Med. Eng. Technol."},{"key":"B60","doi-asserted-by":"publisher","first-page":"5530","DOI":"10.3390\/jcm12175530","article-title":"The management of ruptured abdominal aortic aneurysms: an ongoing challenge","volume":"12","author":"Troisi","year":"2023","journal-title":"J. Clin. Med."},{"key":"B61","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1007\/s11517-009-0573-6","article-title":"Flow pumping system for physiological waveforms","volume":"48","author":"Tsai","year":"2010","journal-title":"Med. Biol. Eng. Comput."},{"key":"B62","doi-asserted-by":"publisher","first-page":"2870","DOI":"10.1007\/s10439-025-03816-w","article-title":"Towards the intravascular delivery of 3D-printed leached SMP for endovascular treatment of intracranial aneurysm","volume":"53","author":"Vega","year":"2025","journal-title":"Ann. Biomed. Eng."},{"key":"B63","doi-asserted-by":"publisher","first-page":"104205","DOI":"10.1016\/j.medengphy.2024.104205","article-title":"Haemodynamic effects of non-Newtonian fluid blood on the abdominal aorta before and after double tear rupture","volume":"130","author":"Wang","year":"2024","journal-title":"Med. Eng. Phys."},{"key":"B64","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/j.engreg.2023.11.001","article-title":"PETG: applications in modern medicine","volume":"5","author":"Yan","year":"2024","journal-title":"Eng. Regen."},{"key":"B65","doi-asserted-by":"publisher","first-page":"3811","DOI":"10.3390\/app9183811","article-title":"A novel fabrication method for compliant silicone phantoms of arterial geometry for use in particle image velocimetry of haemodynamics","volume":"9","author":"Yazdi","year":"2019","journal-title":"Appl. Sci."},{"key":"B66","doi-asserted-by":"publisher","first-page":"2305880","DOI":"10.1002\/adfm.202305880","article-title":"Injectable shear-thinning hydrogels with sclerosing and matrix metalloproteinase modulatory properties for the treatment of vascular malformations","volume":"33","author":"Zehtabi","year":"2023","journal-title":"Adv. Funct. Mater."},{"key":"B67","doi-asserted-by":"publisher","first-page":"109398","DOI":"10.1016\/j.matdes.2020.109398","article-title":"Recent advances in 3D bioprinting of vascularized tissues","volume":"199","author":"Zhang","year":"2021","journal-title":"Mater. and Des."}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2026.1918602\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T08:42:39Z","timestamp":1790584959000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2026.1918602\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,28]]},"references-count":67,"alternative-id":["10.3389\/fbioe.2026.1918602"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2026.1918602","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,28]]},"article-number":"1918602"}}