{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T15:36:35Z","timestamp":1793288195260,"version":"4.5.0"},"reference-count":34,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T00:00:00Z","timestamp":1790294400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Bioeng. Biotechnol."],"abstract":"<jats:p>Proximal junctional complications are often driven by abrupt mechanical transition at the uppermost instrumented vertebra (UIV). This study used patient-specific finite element analysis to compare biomechanical effects of transverse process hooks and pedicle screws at the UIV, specifically examining how hook orientation influences anterior-posterior load sharing. A validated nonlinear three-dimensional T7\u2013L2 spinal model was developed using data from a 60-year-old woman. Three UIV constructs were evaluated at T9: bilateral pedicle screws (BPS) and downward and upward facing transverse process hook (TPH) configurations. Under a 500-N follower load and 8-Nm bending moments, we analyzed facet joint load (FJL), range of motion (ROM), intradiscal pressure, and mechanical failure risk. In flexion, FJL at the UIV+1\/UIV level decreased by 6.2% and 19.6% in the downward-facing and upward-facing TPH models, respectively, compared with the BPS model. In extension, FJL decreased by 4.2% in the upward-facing TPH model, but increased by 32.4% in the downward-facing TPH model, relative to the BPS model. Both TPH models preserved greater UIV ROM than the bilateral pedicle screw model, with the upward-facing configuration achieving the highest flexion ROM (2.1\u00b0) and the downward-facing configuration achieving the highest extension ROM (3.2\u00b0). In the BPS model, UIV screw pull-out risk was 136% in flexion. Conversely, the risks of transverse process breakage for the downward-facing and upward-facing TPH models were substantially lower (50% and 42%, respectively). Hook constructs increased screw pull-out risk at the UIV-1 level compared with the BPS model. Using the TPH at the UIV can facilitate a biomechanical \u201csoft landing\u201d by preserving segmental motion and reducing posterior load at adjacent levels. These effects are orientation-dependent, with the upward-facing TPH configuration potentially offering greater advantage in preserving segmental motion during flexion. Surgical strategies should be tailored to individual bone quality due to potential stress transfer to the UIV-1 level.<\/jats:p>","DOI":"10.3389\/fbioe.2026.1937182","type":"journal-article","created":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T05:33:52Z","timestamp":1790314432000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Direction-dependent biomechanical effects of transverse process hooks versus pedicle screws at the uppermost instrumented vertebra in adult spinal deformity: a finite element analysis"],"prefix":"10.3389","volume":"14","author":[{"given":"Sun-Joon","family":"Yoo","sequence":"first","affiliation":[{"name":"Department of Neurosurgery, Inha University College of Medicine","place":["Incheon, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bong-Ju","family":"Moon","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Spine and Spinal Cord Institute, Gangnam Severance Hospital, Yonsei University College of Medicine","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jung-Do","family":"Eom","sequence":"additional","affiliation":[{"name":"RAIDAM Co. Ltd.","place":["Wonju, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young-Hoon","family":"Won","sequence":"additional","affiliation":[{"name":"CGBio Co. Ltd.","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jae Keun","family":"Oh","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyung-Hyun","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Spine and Spinal Cord Institute, Gangnam Severance Hospital, Yonsei University College of Medicine","place":["Seoul, Republic of Korea"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,9,25]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"280","DOI":"10.3171\/2017.6.Spine1492","article-title":"Adjacent-segment disease after thoracic pedicle screw fixation","volume":"28","author":"Agarwal","year":"2018","journal-title":"J. Neurosurg. Spine"},{"key":"B2","doi-asserted-by":"publisher","first-page":"044101","DOI":"10.1088\/1748-6041\/3\/4\/044101","article-title":"Comparison of the load-sharing characteristics between pedicle-based dynamic and rigid rod devices","volume":"3","author":"Ahn","year":"2008","journal-title":"Biomed. Mater"},{"key":"B3","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1097\/bor.0000000000000183","article-title":"Role of cortical bone in bone fragility","volume":"27","author":"Bala","year":"2015","journal-title":"Curr. Opin. Rheumatol."},{"key":"B4","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/s0021-9290(03)00257-4","article-title":"Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue","volume":"37","author":"Bayraktar","year":"2004","journal-title":"J. Biomech."},{"key":"B5","doi-asserted-by":"publisher","first-page":"125","DOI":"10.3171\/2016.6.Spine151477","article-title":"The effect of posterior polyester tethers on the biomechanics of proximal junctional kyphosis: a finite element analysis","volume":"26","author":"Bess","year":"2017","journal-title":"J. Neurosurg. Spine"},{"key":"B6","doi-asserted-by":"publisher","first-page":"E716","DOI":"10.1097\/BRS.0b013e3181ae23d1","article-title":"In situ contact analysis of the prosthesis components of Prodisc-L in lumbar spine following total disc replacement","volume":"34","author":"Chen","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"key":"B7","doi-asserted-by":"publisher","first-page":"855","DOI":"10.1016\/j.spinee.2021.01.017","article-title":"Biomechanical comparison of semirigid junctional fixation techniques to prevent proximal junctional failure after thoracolumbar adult spinal deformity correction","volume":"21","author":"Doodkorte","year":"2021","journal-title":"Spine J."},{"key":"B8","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1186\/s12891-016-0980-4","article-title":"Biomechanical response of lumbar facet joints under follower preload: a finite element study","volume":"17","author":"Du","year":"2016","journal-title":"BMC Musculoskelet. Disord."},{"key":"B9","doi-asserted-by":"publisher","first-page":"e1360","DOI":"10.1002\/jsp2.1360","article-title":"Facet deflection and strain are dependent on axial compression and distraction in C5-C7 spinal segments under constrained flexion","volume":"7","author":"Foroutan","year":"2024","journal-title":"JOR Spine"},{"key":"B10","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1097\/00007632-199503150-00010","article-title":"Interlaminar shear stresses and laminae separation in a disc. Finite element analysis of the L3-L4 motion segment subjected to axial compressive loads","volume":"20","author":"Goel","year":"1995","journal-title":"Spine (Phila Pa 1976)"},{"key":"B11","doi-asserted-by":"publisher","first-page":"427s","DOI":"10.1177\/1947603520973240","article-title":"Assessment of native human articular cartilage: a biomechanical protocol","volume":"13","author":"Kabir","year":"2021","journal-title":"Cartilage"},{"key":"B12","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1016\/s0021-9290(98)00057-8","article-title":"Yield strain behavior of trabecular bone","volume":"31","author":"Kopperdahl","year":"1998","journal-title":"J. Biomech."},{"key":"B13","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1016\/s0736-0266(01)00185-1","article-title":"Quantitative computed tomography estimates of the mechanical properties of human vertebral trabecular bone","volume":"20","author":"Kopperdahl","year":"2002","journal-title":"J. Orthop. Res."},{"key":"B14","doi-asserted-by":"publisher","first-page":"502","DOI":"10.14245\/ns.2347116.558","article-title":"Radiographic and clinical outcomes of transverse process hook placement at the proximal thoracic upper instrumented vertebra in adult spinal deformity surgery","volume":"21","author":"Lee","year":"2024","journal-title":"Neurospine"},{"key":"B15","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.jbiomech.2017.10.033","article-title":"Load-sharing in the lumbosacral spine in neutral standing and flexed postures - a combined finite element and inverse static study","volume":"70","author":"Liu","year":"","journal-title":"J. Biomech."},{"key":"B16","doi-asserted-by":"publisher","first-page":"E216","DOI":"10.1097\/brs.0000000000002290","article-title":"The effects of orientation of lumbar facet joints on the facet joint contact forces: an in vitro biomechanical study","volume":"43","author":"Liu","year":"","journal-title":"Spine (Phila Pa 1976)"},{"key":"B17","doi-asserted-by":"publisher","first-page":"622","DOI":"10.31616\/asj.2018.12.4.622","article-title":"Effect of different types of upper instrumented vertebrae instruments on proximal junctional kyphosis following adult spinal deformity surgery: pedicle screw versus transverse process hook","volume":"12","author":"Matsumura","year":"2018","journal-title":"Asian Spine J."},{"key":"B18","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1055\/s-0035-1563611","article-title":"Biomechanical analysis of the proximal adjacent segment after multilevel instrumentation of the thoracic spine: do hooks ease the transition?","volume":"6","author":"Metzger","year":"2016","journal-title":"Glob. Spine J."},{"key":"B19","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.1007\/s43390-022-00506-8","article-title":"Clinically relevant biomechanical properties of three different fixation techniques of the upper instrumented vertebra in deformity surgery","volume":"10","author":"Nevzati","year":"2022","journal-title":"Spine Deform."},{"key":"B20","doi-asserted-by":"publisher","first-page":"1072","DOI":"10.1177\/21925682211018467","article-title":"Longer screws can reduce the stress on the upper instrumented vertebra with long spinal fusion surgery: a finite element analysis study","volume":"13","author":"Oe","year":"2023","journal-title":"Glob. Spine J."},{"key":"B21","doi-asserted-by":"publisher","first-page":"1938","DOI":"10.1097\/01.brs.0000137069.88904.03","article-title":"Adjacent segment disease after lumbar or lumbosacral fusion: review of the literature","volume":"29","author":"Park","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"B22","doi-asserted-by":"publisher","first-page":"3138","DOI":"10.1177\/21925682251319758","article-title":"Effects of transverse process hook fixation for preventing proximal junctional kyphosis\/failure in adult spinal deformity surgery: a multiple regression analysis adjusting for confounding factors","volume":"15","author":"Park","year":"2025","journal-title":"Glob. Spine J."},{"key":"B23","doi-asserted-by":"publisher","first-page":"540","DOI":"10.1016\/s0736-0266(02)00202-4","article-title":"Effect of compressive follower preload on the flexion-extension response of the human lumbar spine","volume":"21","author":"Patwardhan","year":"2003","journal-title":"J. Orthop. Res."},{"key":"B24","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1007\/s11914-018-0478-0","article-title":"The influence of cortical porosity on the strength of bone during growth and advancing age","volume":"16","author":"Ramchand","year":"2018","journal-title":"Curr. Osteoporos. Rep."},{"key":"B25","doi-asserted-by":"publisher","first-page":"1520","DOI":"10.1016\/j.jbiomech.2009.03.048","article-title":"Applying a follower load delivers realistic results for simulating standing","volume":"42","author":"Rohlmann","year":"2009","journal-title":"J. Biomech."},{"key":"B26","doi-asserted-by":"publisher","first-page":"643154","DOI":"10.3389\/fbioe.2021.643154","article-title":"Patient-specific finite element models of posterior pedicle screw fixation: effect of screw's size and geometry","volume":"9","author":"Sensale","year":"2021","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B27","doi-asserted-by":"publisher","first-page":"3252","DOI":"10.1016\/j.jbiomech.2016.08.003","article-title":"Effect of follower load on motion and stiffness of the human thoracic spine with intact rib cage","volume":"49","author":"Sis","year":"2016","journal-title":"J. Biomech."},{"key":"B28","doi-asserted-by":"publisher","first-page":"E826","DOI":"10.1097\/brs.0000000000000367","article-title":"Transverse process hooks at upper instrumented vertebra provide more gradual motion transition than pedicle screws","volume":"39","author":"Thawrani","year":"2014","journal-title":"Spine (Phila Pa 1976)"},{"key":"B29","doi-asserted-by":"publisher","first-page":"E280","DOI":"10.1097\/bsd.0000000000001204","article-title":"Optimal anchor at the uppermost instrumented vertebra in long fusion from the pelvis to the lower thoracic spine in elderly patients with degenerative spinal deformity: hook versus pedicle screw","volume":"35","author":"Tsutsui","year":"2022","journal-title":"Clin. Spine Surg."},{"key":"B30","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1097\/00007632-199904150-00005","article-title":"New in vivo measurements of pressures in the intervertebral disc in daily life","volume":"24","author":"Wilke","year":"1999","journal-title":"Spine (Phila Pa 1976)"},{"key":"B31","doi-asserted-by":"publisher","first-page":"e70052","DOI":"10.1002\/jsp2.70052","article-title":"Range of motion and neutral zone of all human spinal motion segments: a data collection of 30 years of in vitro experiments performed under standardized testing conditions","volume":"8","author":"Wilke","year":"2025","journal-title":"JOR Spine"},{"key":"B32","doi-asserted-by":"publisher","first-page":"377","DOI":"10.14245\/ns.1938100.050","article-title":"Bicortical screw purchase at upper instrumented vertebra (UIV) can cause UIV fracture after adult spinal deformity surgery: a finite element analysis study","volume":"17","author":"Wui","year":"2020","journal-title":"Neurospine"},{"key":"B33","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1186\/s13018-024-04896-5","article-title":"The reduced cortical bone density in vertebral bodies: risk for osteoporotic fractures? Insights from CT analysis","volume":"19","author":"Yang","year":"2024","journal-title":"J. Orthop. Surg. Res."},{"key":"B34","doi-asserted-by":"publisher","first-page":"1219","DOI":"10.14245\/ns.2448804.402","article-title":"Application of transverse process hooks at distal thoracic vertebrae in uppermost vertebral instrumentation for adult spinal deformity surgery: special focus on delayed-onset neurologic deficits","volume":"21","author":"Yoo","year":"2024","journal-title":"Neurospine"}],"updated-by":[{"DOI":"10.3389\/fbioe.2026.2034046","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T00:00:00Z","timestamp":1793232000000}}],"container-title":["Frontiers in Bioengineering and Biotechnology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2026.1937182\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T15:21:05Z","timestamp":1793287265000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fbioe.2026.1937182\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,25]]},"references-count":34,"alternative-id":["10.3389\/fbioe.2026.1937182"],"URL":"https:\/\/doi.org\/10.3389\/fbioe.2026.1937182","relation":{},"ISSN":["2296-4185"],"issn-type":[{"value":"2296-4185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,25]]},"article-number":"1937182"}}