{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T06:09:33Z","timestamp":1778479773730,"version":"3.51.4"},"reference-count":117,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T00:00:00Z","timestamp":1778457600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cell. Infect. Microbiol."],"abstract":"<jats:p>The escalating global burden of antimicrobial resistance (AMR) necessitates diagnostic strategies that can overcome the limitations of conventional culture-based methods, which often require several days to generate clinically actionable results. Such delays are associated with increased mortality, inappropriate antibiotic use, and continued transmission of resistant pathogens. In this context, microfluidic chip technology has emerged as a promising platform for rapid, miniaturized, and increasingly automated point-of-care diagnostics. Recent advances have enabled integrated lab-on-a-chip systems that combine bacterial isolation, phenotypic antimicrobial susceptibility testing, and genotypic resistance detection within closed and self-contained architectures, thereby reducing contamination risk and operator dependence. In addition, these platforms are increasingly capable of operating at single-cell resolution, allowing the detection of heteroresistance and resistant subpopulations that may be overlooked by conventional bulk assays. A major advantage of microfluidic systems is their ability to bridge phenotypic and genotypic diagnostics by enabling real-time monitoring of bacterial growth, metabolic activity, and morphological responses to antibiotics while simultaneously incorporating on-chip nucleic acid amplification for resistance gene detection. This integrated approach improves the interpretation of discrepancies between genetic determinants and functional resistance. Studies to date have demonstrated high sensitivity and specificity in complex clinical matrices, including blood, urine, and sputum, with turnaround times reduced from days to less than one hour in some applications. Furthermore, the integration of CRISPR-Cas systems, nanomaterial-enhanced biosensing, and machine learning has further improved analytical performance and data interpretation. Nevertheless, important translational challenges remain, including scalable manufacturing, regulatory standardization, and integration into routine clinical workflows. Future microfluidic platforms are expected to support multiplexed, intelligent antimicrobial susceptibility testing capable of simultaneous pathogen identification, resistance profiling, and therapeutic guidance, thereby advancing precision diagnostics for AMR management.<\/jats:p>","DOI":"10.3389\/fcimb.2026.1819856","type":"journal-article","created":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T05:30:25Z","timestamp":1778477425000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Research advances in the application of microfluidic chip technology for rapid detection of antibiotic-resistant bacteria"],"prefix":"10.3389","volume":"16","author":[{"given":"Lijun","family":"Xia","sequence":"first","affiliation":[{"name":"Wuhou District People\u2019s Hospital","place":["Chengdu, China"]},{"name":"Wuhou District Health Hospital Woman and Children","place":["Chengdu, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Changqing","family":"Tang","sequence":"additional","affiliation":[{"name":"Wuhou District People\u2019s Hospital","place":["Chengdu, China"]},{"name":"Wuhou District Health Hospital Woman and Children","place":["Chengdu, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dalong","family":"Tong","sequence":"additional","affiliation":[{"name":"Wuhou District People\u2019s Hospital","place":["Chengdu, China"]},{"name":"Wuhou District Health Hospital Woman and Children","place":["Chengdu, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qifu","family":"He","sequence":"additional","affiliation":[{"name":"Wuhou District People\u2019s Hospital","place":["Chengdu, China"]},{"name":"Wuhou District Health Hospital Woman and Children","place":["Chengdu, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2026,5,11]]},"reference":[{"key":"B54","doi-asserted-by":"publisher","first-page":"16181","DOI":"10.1038\/S41598-024-66706-6","article-title":"Single-cell level LasR-mediated quorum sensing response of Pseudomonas aeruginosa to pulses of signal molecules","volume":"14","author":"\u00c1brah\u00e1m","year":"2024","journal-title":"Sci. Rep."},{"key":"B44","doi-asserted-by":"publisher","DOI":"10.1002\/mame.202200053","article-title":"A review of cyclic olefin copolymer applications in microfluidics and microdevices","volume":"307","author":"Agha","year":"2022","journal-title":"Macromol. Mater. Eng."},{"key":"B78","doi-asserted-by":"publisher","first-page":"061301","DOI":"10.1063\/5.0029846","article-title":"Is microfluidics the \u201cassembly line\u201d for CRISPR-Cas9 gene-editing","volume":"14","author":"Ahmadi","year":"2020","journal-title":"Biomicrofluidics"},{"key":"B40","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1007\/s00216-022-04459-9","article-title":"Improving droplet microfluidic systems for studying single bacteria growth","volume":"415","author":"Akuoko","year":"2022","journal-title":"Anal. Bioanal. Chem."},{"key":"B39","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/S40258-025-00969-6","article-title":"Antimicrobial resistance (AMR) development map: a conceptual map and a tool to support economic evaluation of AMR interventions","volume":"23","author":"Aluzaite","year":"2025","journal-title":"Appl. Health Econ Health Policy"},{"key":"B45","doi-asserted-by":"publisher","first-page":"6478","DOI":"10.3390\/MA15186478","article-title":"The fabrication and bonding of thermoplastic microfluidics: a review","volume":"15","author":"Amid","year":"2022","journal-title":"Materials"},{"key":"B46","doi-asserted-by":"publisher","DOI":"10.1016\/j.matdes.2022.111517","article-title":"Development of glass-based microfluidic devices: a review on its fabrication and biologic applications","volume":"225","author":"Aralekallu","year":"2023","journal-title":"Mater. Des."},{"key":"B122","doi-asserted-by":"publisher","DOI":"10.1016\/J.TRAC.2024.118004","article-title":"A review on recent advances of AI-integrated microfluidics for analytical and bioanalytical applications","volume":"181","author":"Asadian","year":"2024","journal-title":"Trends Analytical Chem."},{"key":"B94","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1038\/S41378-024-00738-W","article-title":"Enhancing the performance of porous silicon biosensors: the interplay of nanostructure design and microfluidic integration","volume":"10","author":"Awawdeh","year":"2024","journal-title":"Microsystems Nanoengineering"},{"key":"B50","doi-asserted-by":"publisher","DOI":"10.1093\/jacamr\/dlae202","article-title":"Antimicrobial resistance-attributable mortality: a patient-level analysis","volume":"6","author":"Baltas","year":"2024","journal-title":"JAC-Antimicrob. Resist."},{"key":"B52","doi-asserted-by":"publisher","first-page":"114377","DOI":"10.1016\/J.ISCI.2025.114377","article-title":"Droplet microfluidics strategies for overcoming bottlenecks in antibiotics discovery","volume":"29","author":"Barakat","year":"2026","journal-title":"iScience"},{"key":"B62","doi-asserted-by":"publisher","DOI":"10.1128\/SPECTRUM.00322-22","article-title":"Development of microfluidic chip-based loop-mediated isothermal amplification (LAMP) method for detection of carbapenemase producing bacteria","volume":"10","author":"Bin","year":"2022","journal-title":"Microbiol. Spectr."},{"key":"B75","doi-asserted-by":"publisher","DOI":"10.3389\/FBIOE.2022.851712","article-title":"Powerful CRISPR-based biosensing techniques and their integration with microfluidic platforms","volume":"10","author":"Bing","year":"2022","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B26","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1111\/jvp.12962","article-title":"Diagnostic clinical microbiology","volume":"44","author":"Blondeau","year":"2021","journal-title":"J. Vet. Pharmacol. Ther."},{"key":"B32","doi-asserted-by":"publisher","DOI":"10.1016\/j.contraception.2024.110553","article-title":"Characteristics of foreign-born abortion patients in the United States, 2021-2022","volume":"140","author":"Cartwright","year":"2024","journal-title":"Contraception"},{"key":"B115","doi-asserted-by":"publisher","first-page":"2486","DOI":"10.1039\/d1lc00302j","article-title":"A microfluidic device enabling deterministic single cell trapping and release","volume":"21","author":"Chai","year":"2021","journal-title":"Lab. Chip"},{"key":"B81","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1126\/science.aar6245","article-title":"CRISPR-Cas12a target binding unleashes indiscriminate single-stranded DNase activity","volume":"360","author":"Chen","year":"2018","journal-title":"Science"},{"key":"B58","doi-asserted-by":"publisher","first-page":"114703","DOI":"10.1016\/J.BIOS.2022.114703","article-title":"Development of a novel microfluidic biosensing platform integrating micropillar array electrode and acoustic microstreaming techniques","volume":"22","author":"Chen","year":"2023","journal-title":"Biosens. Bioelectron."},{"key":"B53","doi-asserted-by":"publisher","first-page":"6100","DOI":"10.1039\/D5LC00216H","article-title":"Transforming microfluidics for single-cell analysis with robotics and artificial intelligence","volume":"25","author":"Cheng","year":"2025","journal-title":"Lab. Chip"},{"key":"B68","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1007\/S00284-024-04027-7","article-title":"Microfluidic chip-based enrichment and nucleic acid extraction for quantitative detection of Mycobacterium smegmatis in aerosols","volume":"82","author":"Cheng","year":"2024","journal-title":"Curr. Microbiol."},{"key":"B87","doi-asserted-by":"publisher","DOI":"10.1093\/bib\/bbac453","article-title":"A rapid bacterial pathogen and antimicrobial resistance diagnosis workflow using Oxford nanopore adaptive sequencing method","volume":"23","author":"Cheng","year":"2022","journal-title":"Brief Bioinform."},{"key":"B59","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1186\/S12916-025-04428-W","article-title":"Ultrahigh-throughput screening of heterogeneous vancomycin-intermediate Staphylococcus aureus based on fluorescence-activated droplet sorting","volume":"23","author":"Cheng","year":"2025","journal-title":"BMC Med."},{"key":"B61","doi-asserted-by":"publisher","first-page":"1394","DOI":"10.3390\/MI13091394","article-title":"Nucleic acid detection with ion concentration polarization microfluidic chip for reduced cycle numbers of polymerase chain reaction","volume":"13","author":"Chengzhuang","year":"2022","journal-title":"Micromachines"},{"key":"B73","doi-asserted-by":"publisher","first-page":"38183","DOI":"10.1016\/J.SNB.2025.138183","article-title":"Rapid quantitative detection, identification and antimicrobial susceptibility testing of pathogens in blood using the static droplet array (SDA) chip-based method","volume":"44","author":"Diao","year":"2025","journal-title":"Sensors Actuators: B. Chem."},{"key":"B12","doi-asserted-by":"publisher","DOI":"10.1016\/j.aca.2024.342429","article-title":"A review of the recent achievements and future trends on 3D printed microfluidic devices for bioanalytical applications","volume":"1299","author":"Duarte","year":"2024","journal-title":"Anal. Chim. Acta"},{"key":"B23","doi-asserted-by":"publisher","DOI":"10.1093\/jacamr\/dlac142","article-title":"A call to action-stopping antimicrobial resistance","volume":"5","author":"Eisinger","year":"2023","journal-title":"JAC-Antimicrob. Resist."},{"key":"B14","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1093\/INFDIS\/JIAA263","article-title":"Role of rapid diagnostics in diagnosis and management of patients with sepsis","volume":"222","author":"Eubank","year":"2021","journal-title":"J. Infect. Dis."},{"key":"B8","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1039\/d0lc00966k","article-title":"An integrated microfluidic system for early detection of sepsis-inducing bacteria","volume":"21","author":"Fang","year":"2020","journal-title":"Lab. Chip"},{"key":"B119","doi-asserted-by":"publisher","DOI":"10.1016\/j.talanta.2025.128325","article-title":"Bacterial identification in SERS-integrated microfluidics using CNN-driven 2D classification of 1D spectra","volume":"295","author":"Feizpour","year":"2025","journal-title":"Talanta"},{"key":"B36","doi-asserted-by":"publisher","first-page":"9603","DOI":"10.1007\/S00210-024-03318-X","article-title":"The challenge of antimicrobial resistance (AMR): current status and future prospects","volume":"397","author":"Ferrara","year":"2024","journal-title":"Naunyn-Schmiedeberg\u2019s Arch. Pharmacol."},{"key":"B83","doi-asserted-by":"publisher","first-page":"5898","DOI":"10.1038\/S41467-025-60491-0","article-title":"Context-Seq: CRISPR-Cas9 targeted nanopore sequencing for transmission dynamics of antimicrobial resistance","volume":"16","author":"Fuhrmeister","year":"2025","journal-title":"Nat. Commun."},{"key":"B49","doi-asserted-by":"publisher","first-page":"165807","DOI":"10.1016\/J.CEJ.2025.165807","article-title":"Microfluidics enables rapid and facile fabrication of multi-component antimicrobial nanoparticles","volume":"5","author":"Gamage","year":"2025","journal-title":"Chem. Eng. J."},{"key":"B113","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2024.1421831","article-title":"Unveiling the state of the art: a systematic review and meta-analysis of paper-based microfluidic devices","volume":"12","author":"Garc\u00eda-Azuma","year":"2024","journal-title":"Front. Bioeng. Biotechnol."},{"key":"B82","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1126\/science.aam9321","article-title":"Nucleic acid detection with CRISPR-Cas13a\/C2c2","volume":"356","author":"Gootenberg","year":"2017","journal-title":"Science"},{"key":"B20","doi-asserted-by":"publisher","DOI":"10.1002\/adhm.202101546","article-title":"Biosensors and point-of-care devices for bacterial detection: rapid diagnostics informing antibiotic therapy","volume":"11","author":"Gopal","year":"2021","journal-title":"Adv. Healthcare Mater."},{"key":"B31","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1186\/S13023-024-03293-9","article-title":"Meeting abstracts from the 12th European conference on rare diseases and orphan products","volume":"19","author":"Graham","year":"2024","journal-title":"Orphanet J. Rare Dis."},{"key":"B43","doi-asserted-by":"publisher","first-page":"14012","DOI":"10.1038\/S41598-025-97111-2","article-title":"Sorption and release of small molecules in PDMS and COC for organs on chip","volume":"15","author":"Grindulis","year":"2025","journal-title":"Sci. Rep."},{"key":"B86","doi-asserted-by":"publisher","first-page":"118369","DOI":"10.1016\/J.BIOS.2026.118369","article-title":"A microreactor system for point-of-care viral genome sequencing","volume":"297","author":"Hadlock","year":"2026","journal-title":"Biosens. Bioelectron."},{"key":"B123","doi-asserted-by":"publisher","DOI":"10.1371\/JOURNAL.PONE.0330265","article-title":"Rapid label-free identification of seven bacterial species using microfluidics, single-cell time-lapse phase-contrast microscopy, and deep learning-based image and video classification","volume":"20","author":"Hallstr\u00f6m","year":"2025","journal-title":"PloS One"},{"key":"B114","doi-asserted-by":"publisher","first-page":"25677","DOI":"10.1039\/d1ra04916j","article-title":"Enhanced passive mixing for paper microfluidics","volume":"11","author":"Hamidon","year":"2021","journal-title":"RSC Adv."},{"key":"B34","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1093\/jac\/dkab418","article-title":"BSAC vanguard series: antimicrobial resistance and the future of diagnostic testing","volume":"77","author":"Hayward","year":"2022","journal-title":"J. Antimicrob. Chemother."},{"key":"B93","doi-asserted-by":"publisher","DOI":"10.1016\/j.bioelechem.2025.109207","article-title":"Gold nanoparticle-modified graphene oxide electrochemical aptasensor for ultrasensitive detection of interferon gamma in kidney transplants","volume":"169","author":"Hosseini","year":"2025","journal-title":"Bioelectrochemistry"},{"key":"B35","doi-asserted-by":"publisher","first-page":"1748","DOI":"10.1039\/D4CC05488A","article-title":"Surveillance of antimicrobial resistance using isothermal amplification: a review","volume":"61","author":"Hou","year":"2025","journal-title":"Chem. Commun. (Cambridge England)"},{"key":"B5","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1021\/acs.accounts.1c00462","article-title":"Combating antimicrobial resistance via single-cell diagnostic technologies powered by droplet microfluidics","volume":"55","author":"Hsieh","year":"2021","journal-title":"Acc. Chem. Res."},{"key":"B102","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1038\/S44259-024-00033-8","article-title":"Limitations of current techniques in clinical antimicrobial resistance diagnosis: examples and future prospects","volume":"2","author":"Jack","year":"2024","journal-title":"NPJ Antimicrobials Resistance"},{"key":"B65","doi-asserted-by":"publisher","first-page":"11039","DOI":"10.1038\/s41598-020-67995-3","article-title":"Development of simple and efficient lab-on-a-disc platforms for automated chemical cell lysis","volume":"10","author":"Jahromi","year":"2020","journal-title":"Sci. Rep."},{"key":"B29","doi-asserted-by":"publisher","first-page":"100940","DOI":"10.1016\/J.LANMIC.2024.07.003","article-title":"WHO publishes updated list of bacterial priority pathogens","volume":"5","author":"Jesudason","year":"2024","journal-title":"Lancet Microbe"},{"key":"B37","doi-asserted-by":"publisher","DOI":"10.1016\/j.lanmic.2025.101326","article-title":"EMBL-EBI\u2019s AMR portal: a new gateway in global antimicrobial resistance research","volume":"6","author":"Jesudason","year":"2026","journal-title":"Lancet Microbe"},{"key":"B71","doi-asserted-by":"publisher","DOI":"10.1002\/ANIE.202501913","article-title":"AM-DMF-ddRPA: an all-in-one digital microfluidic platform for rapid and automatic digital nucleic acid analysis","volume":"64","author":"Ji","year":"2025","journal-title":"Angewandte Chemie (International Ed. English)"},{"key":"B116","doi-asserted-by":"publisher","first-page":"2899","DOI":"10.2147\/IDR.S470821","article-title":"Artificial intelligence-clinical decision support system in infectious disease control: Combatting multidrug-resistant Klebsiella pneumoniae with machine learning","volume":"17","author":"Jian","year":"2024","journal-title":"Infect. Drug Resist."},{"key":"B90","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1039\/D4LC00619D","article-title":"Detecting telomerase activity at the single-cell level using a CRISPR-Cas12a-based chip","volume":"25","author":"Jiang","year":"2024","journal-title":"Lab. Chip"},{"key":"B3","doi-asserted-by":"publisher","first-page":"S507","DOI":"10.1093\/cid\/ciad634","article-title":"Methodological approach to identify and expand the volume of antimicrobial resistance (AMR) data in the human health sector in low- and middle-income countries in Asia: implications for local and regional AMR surveillance systems strengthening","volume":"77","author":"Joh","year":"2023","journal-title":"Clin. Infect. Diseases: An. Off. Publ. Infect. Dis. Soc. America"},{"key":"B57","doi-asserted-by":"publisher","first-page":"36","DOI":"10.2174\/0113816128315140240828110618","article-title":"An overview of microfluidic phenotype separation of bacteria","volume":"32","author":"Juliet","year":"2024","journal-title":"Curr. Pharm. Des."},{"key":"B97","doi-asserted-by":"publisher","DOI":"10.1126\/SCIADV.ABM2382","article-title":"A functional genomic approach to actionable gene fusions for precision oncology","volume":"8","author":"Jun","year":"2022","journal-title":"Sci. Adv."},{"key":"B111","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1007\/s11033-024-09840-8","article-title":"Harnessing the power of clustered regularly interspaced short palindromic repeats (CRISPR) based microfluidics for next-generation molecular diagnostics","volume":"51","author":"Kaur","year":"2024","journal-title":"Mol. Biol. Rep."},{"key":"B38","doi-asserted-by":"publisher","first-page":"2103","DOI":"10.1162\/jocn_a_01621","article-title":"Reasoning about durations","volume":"32","author":"Kelly","year":"2020","journal-title":"J. Cognit. Neurosci."},{"key":"B47","doi-asserted-by":"publisher","DOI":"10.1063\/5.0306466","article-title":"Microfluidics for antimicrobial susceptibility testing: current advances and future perspectives","volume":"15","author":"Khan","year":"2025","journal-title":"Front. Microbiol."},{"key":"B56","doi-asserted-by":"publisher","first-page":"111492","DOI":"10.1016\/J.FOODCONT.2025.111492","article-title":"A pangenome-informed portable qPCR microchip assay for detecting stress-resistant Listeria monocytogenes (LM-ResiChip)","volume":"17","author":"Kim","year":"2025","journal-title":"Food Control"},{"key":"B69","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/j.ihj.2021.02.008","article-title":"Door to balloon time in patients presenting with acute ST elevation myocardial infarction and time factors influencing it; an observational study from a tertiary care teaching hospital in India","volume":"73","author":"Krishnan","year":"2021","journal-title":"Indian Heart J."},{"key":"B33","doi-asserted-by":"publisher","first-page":"1283","DOI":"10.1016\/S0140-6736(25)01335-2","article-title":"Enteric (typhoid and paratyphoid) fever","volume":"406","author":"Kuehn","year":"2025","journal-title":"Lancet (London England)"},{"key":"B91","doi-asserted-by":"publisher","first-page":"5685","DOI":"10.1007\/s00216-021-03560-9","article-title":"Microchip for continuous DNA analysis based on gel electrophoresis coupled with co-injection of size markers and in-channel staining","volume":"413","author":"Kwak","year":"2021","journal-title":"Anal. Bioanal. Chem."},{"key":"B19","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1055\/a-2133-4826","article-title":"Diagnostic approaches for invasive mycoses: what\u2019s hot","volume":"149","author":"Lass-Fl\u00f6rl","year":"2024","journal-title":"Deutsche Medizinische Wochenschrift (1946)"},{"key":"B6","doi-asserted-by":"publisher","DOI":"10.1016\/j.bios.2020.112890","article-title":"Rapid antimicrobial susceptibility tests on an integrated microfluidic device for precision medicine of antibiotics","volume":"176","author":"Lee","year":"2020","journal-title":"Biosens. Bioelectron."},{"key":"B21","doi-asserted-by":"publisher","DOI":"10.1038\/s43586-022-00190-y","article-title":"Single-cell pathogen diagnostics for combating antibiotic resistance","volume":"3","author":"Li","year":"2023","journal-title":"Nat. Rev. Methods Primers"},{"key":"B9","doi-asserted-by":"publisher","DOI":"10.1016\/j.aca.2023.340995","article-title":"Lower fluidic resistance of double-layer droplet continuous flow PCR microfluidic chip for rapid detection of bacteria","volume":"1251","author":"Li","year":"2023","journal-title":"Anal. Chim. Acta"},{"key":"B17","doi-asserted-by":"publisher","DOI":"10.3390\/microorganisms12091824","article-title":"Getting up to speed: rapid pathogen and antimicrobial resistance diagnostics in sepsis","volume":"12","author":"Liborio","year":"2024","journal-title":"Microorganisms"},{"key":"B88","doi-asserted-by":"publisher","DOI":"10.1186\/s13073-024-01416-2","article-title":"Comprehensive pathogen identification and antimicrobial resistance prediction from positive blood cultures using nanopore sequencing technology","volume":"16","author":"Liu","year":"2024","journal-title":"Genome Med."},{"key":"B30","doi-asserted-by":"publisher","first-page":"542","DOI":"10.7196\/SAMJ.2022.V112I8.16351","article-title":"Carbapenem-resistant Enterobacterales in patients with bacteraemia at tertiary academic hospitals in South Africa, 2019 - 2020: an update","volume":"112","author":"Lowe","year":"2022","journal-title":"South. Afr. Med. J."},{"key":"B11","doi-asserted-by":"publisher","DOI":"10.3390\/mi14050972","article-title":"Advances in integration, wearable applications, and artificial intelligence of biomedical microfluidics systems","volume":"14","author":"Ma","year":"2023","journal-title":"Micromachines"},{"key":"B60","doi-asserted-by":"publisher","first-page":"e824","DOI":"10.1002\/CTM2.824","article-title":"Detection of pathogens and antimicrobial resistance genes directly from urine samples in patients suspected of urinary tract infection by metagenomics nanopore sequencing: a large-scale multi-centre study","volume":"13","author":"Manjiao","year":"2023","journal-title":"Clin. Transl. Med."},{"key":"B25","doi-asserted-by":"publisher","first-page":"6","DOI":"10.37201\/req\/s01.02.2022","article-title":"Urgent need for a rapid microbiological diagnosis in critically ill pneumonia","volume":"35","author":"Mart\u00ednez Sagasti","year":"2022","journal-title":"Rev. Espanola Quimioterapia: Publicacion Oficial la Sociedad Espanola Quimioterapia"},{"key":"B74","doi-asserted-by":"publisher","first-page":"41814","DOI":"10.1038\/S41598-025-26706-6","article-title":"Association of the existence of CRISPR-Cas system and antimicrobial resistance in multi-drug resistant Klebsiella pneumoniae in Egypt","volume":"15","author":"Menofy","year":"2025","journal-title":"Sci. Rep."},{"key":"B24","doi-asserted-by":"publisher","DOI":"10.3389\/fimmu.2020.01938","article-title":"Evolutionary approaches to combat antibiotic resistance: opportunities and challenges for precision medicine","volume":"11","author":"Merker","year":"2020","journal-title":"Front. Immunol."},{"key":"B117","doi-asserted-by":"publisher","first-page":"125620","DOI":"10.1016\/J.ENVPOL.2024.125620","article-title":"Measuring water pollution effects on antimicrobial resistance through explainable artificial intelligence","volume":"36","author":"Monaco","year":"2025","journal-title":"Environ. pollut."},{"key":"B95","doi-asserted-by":"publisher","DOI":"10.1016\/J.SAA.2022.122206","article-title":"Pseudomonas aeruginosa detection based on droplets incubation using an integrated microfluidic chip, laser spectroscopy, and machine learning","volume":"28","author":"Mubashir","year":"2023","journal-title":"Spectrochimica Acta Part. A. Mol. Biomolecular Spectrosc."},{"key":"B79","doi-asserted-by":"publisher","first-page":"4779","DOI":"10.1039\/d1lc00829c","article-title":"A method of sequential liquid dispensing for the multiplexed genetic diagnosis of viral infections in a microfluidic device","volume":"21","author":"Natsuhara","year":"2021","journal-title":"Lab. Chip"},{"key":"B48","doi-asserted-by":"publisher","first-page":"2550","DOI":"10.1021\/cr300337x","article-title":"Advances in microfluidic materials, functions, integration, and applications","volume":"113","author":"Nge","year":"2013","journal-title":"Chem. Rev."},{"key":"B72","doi-asserted-by":"publisher","first-page":"112685","DOI":"10.1016\/J.MICROC.2025.112685","article-title":"A self-priming digital microfluidic chip for single-cell antibiotic susceptibility testing","volume":"20","author":"Pang","year":"2025","journal-title":"Microchem. J."},{"key":"B84","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1038\/S44259-025-00157-5","article-title":"The applications and advantages of nanopore sequencing in bacterial antimicrobial resistance surveillance and research","volume":"3","author":"Peng","year":"2025","journal-title":"NPJ Antimicrobials Resistance"},{"key":"B16","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1016\/j.idc.2023.12.003","article-title":"Novel and rapid diagnostics for common infections in the critically ill patient","volume":"38","author":"Pickens","year":"2024","journal-title":"Infect. Dis. Clinics North. America"},{"key":"B104","doi-asserted-by":"publisher","DOI":"10.1093\/clinchem\/hvaf086.298","article-title":"A-309 rapid detection of bloodstream infections with the Bio Fire Blood Culture Identification 2 panel compared to standard MALDI-TOF identification","volume":"71","author":"Pratt","year":"2025","journal-title":"Clin. Chem."},{"key":"B120","doi-asserted-by":"publisher","first-page":"115837","DOI":"10.1016\/J.BIOS.2023.115837","article-title":"Deep learning enhanced multiplex detection of viable foodborne pathogens in digital microfluidic chip","volume":"245","author":"Quan","year":"2023","journal-title":"Biosens. Bioelectron."},{"key":"B64","doi-asserted-by":"publisher","DOI":"10.3390\/PH15121498","article-title":"CRISPR-Cas system: a tool to eliminate drug-resistant gram-negative bacteria","volume":"15","author":"Rajeshwari","year":"2022","journal-title":"Pharmaceuticals"},{"key":"B18","doi-asserted-by":"publisher","DOI":"10.3390\/ijms22010456","article-title":"Emerging options for the diagnosis of bacterial infections and the characterization of antimicrobial resistance","volume":"22","author":"Rentschler","year":"2021","journal-title":"Int. J. Mol. Sci."},{"key":"B41","doi-asserted-by":"publisher","first-page":"10311","DOI":"10.1021\/acs.jpcb.4c02746","article-title":"Single-cell microfluidics: a primer for microbiologists","volume":"28","author":"Ripandelli","year":"2024","journal-title":"J. Phys. Chem. B"},{"key":"B112","doi-asserted-by":"publisher","first-page":"1815","DOI":"10.1021\/jacsau.1c00318","article-title":"Toward the development of rapid, specific, and sensitive microfluidic sensors: A comprehensive device blueprint","volume":"1","author":"Sathish","year":"2021","journal-title":"JACS Au"},{"key":"B27","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1016\/S1473-3099(25)00118-5","article-title":"The WHO bacterial priority pathogens list 2024: a prioritisation study to guide research, development, and public health strategies against antimicrobial resistance","volume":"25","author":"Sati","year":"2025","journal-title":"Lancet Infect. Dis."},{"key":"B13","doi-asserted-by":"publisher","first-page":"2607","DOI":"10.1039\/d0lc00034e","article-title":"Current state of the art in rapid diagnostics for antimicrobial resistance","volume":"20","author":"Shanmugakani","year":"2020","journal-title":"Lab. Chip"},{"key":"B80","doi-asserted-by":"publisher","first-page":"117178","DOI":"10.1016\/J.BIOS.2025.117178","article-title":"Lift-CM: an integrated lift-heater centrifugal microfluidic platform for point-of-care pathogen nucleic acid detection using isothermal amplification and CRISPR\/Cas12a","volume":"27","author":"Shu","year":"2025","journal-title":"Biosens. Bioelectron."},{"key":"B63","doi-asserted-by":"publisher","DOI":"10.3390\/BIOM15091313","article-title":"Strand displacement chain reaction (SDCR): new hybrid amplification technique for fast and sensitive detection of genetic materials","volume":"15","author":"Smirnova","year":"2025","journal-title":"Biomolecules"},{"key":"B7","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1093\/med\/9780190259631.003.0016","article-title":"Performance and clinical applications of rapid diagnostics for antimicrobial resistance","volume":"55","author":"So","year":"2023","journal-title":"Infect. Chemother."},{"key":"B4","doi-asserted-by":"publisher","DOI":"10.3390\/mi14010046","article-title":"Microfluidic chip for detection of drug resistance at the single-cell level","volume":"14","author":"Song","year":"2022","journal-title":"Micromachines"},{"key":"B15","doi-asserted-by":"publisher","DOI":"10.3390\/microorganisms11040946","article-title":"Multidrug resistance in critically ill patients: an unresolved issue","volume":"11","author":"Spadaro","year":"2023","journal-title":"Microorganisms"},{"key":"B108","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1007\/S00604-025-06996-3","article-title":"Multiplexed detection of respiratory virus RNA using optical pH sensors and injection-molded centrifugal microfluidics","volume":"192","author":"Suarez","year":"2025","journal-title":"Mikrochim. Acta"},{"key":"B96","doi-asserted-by":"publisher","first-page":"17084","DOI":"10.1038\/s41598-021-96609-9","article-title":"An automated real-time microfluidic platform to probe single NK cell heterogeneity and cytotoxicity on-chip","volume":"11","author":"Subedi","year":"2021","journal-title":"Sci. Rep."},{"key":"B110","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1016\/J.HLIFE.2025.04.005","article-title":"Tip optofluidic immunoassay: Evaluating COVID-19 antibody protection with 1 \u03bcL fingertip blood","volume":"3","author":"Tan","year":"2025","journal-title":"hLife"},{"key":"B10","doi-asserted-by":"publisher","first-page":"3947","DOI":"10.1021\/acssensors.2c02008","article-title":"Laser-printed paper-based microfluidic chip based on a multicolor fluorescence carbon dot biosensor for visual determination of multiantibiotics in aquatic products","volume":"7","author":"Tong","year":"2022","journal-title":"ACS Sens."},{"key":"B76","doi-asserted-by":"publisher","first-page":"3101","DOI":"10.1039\/d1an00180a","article-title":"Nucleic acid amplification-based microfluidic approaches for antimicrobial susceptibility testing","volume":"146","author":"Trinh","year":"2021","journal-title":"Analyst"},{"key":"B22","doi-asserted-by":"publisher","first-page":"1702","DOI":"10.1111\/1751-7915.13662","article-title":"Mining for novel antibiotics in the age of antimicrobial resistance","volume":"13","author":"Udaondo","year":"2020","journal-title":"Microb. Biotechnol."},{"key":"B1","doi-asserted-by":"publisher","first-page":"e1880","DOI":"10.1016\/S2214-109X(25)00308-0","article-title":"Global antibiotic consumption and regional antimicrobial resistance, 2010-21: an analysis of pharmaceutical sales and antimicrobial resistance surveillance data","volume":"13","author":"Wang","year":"2025","journal-title":"Lancet Glob. Health"},{"key":"B106","doi-asserted-by":"publisher","first-page":"117084","DOI":"10.1016\/J.BIOS.2024.117084","article-title":"Rapid and precise treatment selection for antimicrobial-resistant infection enabled by a nano-dilution SlipChip","volume":"27","author":"Wang","year":"2025","journal-title":"Biosens. Bioelectron."},{"key":"B42","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1038\/S41378-025-00938-Y","article-title":"Rapid antimicrobial susceptibility tests performed by self-diluting microfluidic chips for drug resistance studies and point-of-care diagnostics","volume":"11","author":"Wat","year":"2025","journal-title":"Microsystems Nanoeng."},{"key":"B118","doi-asserted-by":"publisher","DOI":"10.1002\/SMLL.202510292","article-title":"Rapid bacteria identification and antimicrobial susceptibility testing via 5-min fluorescence in situ hybridization","volume":"22","author":"Wei","year":"2025","journal-title":"Small (Weinheim An. der Bergstrasse Germany)"},{"key":"B28","doi-asserted-by":"publisher","first-page":"2165","DOI":"10.1136\/BMJ.R2165","article-title":"One in six bacterial infections worldwide are now resistant to antibiotics, WHO warns","volume":"391","author":"Wise","year":"2025","journal-title":"BMJ (Clinical Res. Ed.)"},{"key":"B2","doi-asserted-by":"publisher","DOI":"10.1128\/mBio.03109-19","article-title":"A multiplex fluidic chip for rapid phenotypic antibiotic susceptibility testing","volume":"11","author":"Wistrand-Yuen","year":"2020","journal-title":"mBio"},{"key":"B107","doi-asserted-by":"publisher","first-page":"128507","DOI":"10.1016\/J.TALANTA.2025.128507","article-title":"Streamlining diagnosis of bloodstream infections with high-throughput microfluidic isolation and aptamer-based detection strategies","volume":"29","author":"Wu","year":"2026","journal-title":"Talanta"},{"key":"B98","doi-asserted-by":"publisher","first-page":"18842","DOI":"10.1021\/acs.analchem.4c04482","article-title":"Ultrafast evolution of bacterial antimicrobial resistance by picoliter-scale centrifugal microfluidics","volume":"96","author":"Xu","year":"2024","journal-title":"Anal. Chem."},{"key":"B51","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1186\/S12879-024-09212-4","article-title":"Rapid detection of pathogenic fungi from coastal population with respiratory infections using microfluidic chip technology","volume":"24","author":"Yao","year":"2024","journal-title":"BMC Infect. Dis."},{"key":"B67","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2020.00403","article-title":"Evaluation of quadruple real-time PCR method to detect enterococci carrying vancomycin-resistant genes vanA, vanB, vanM in rectal swabs","volume":"7","author":"Yuanhui","year":"2020","journal-title":"Front. Med."},{"key":"B105","doi-asserted-by":"publisher","first-page":"2780","DOI":"10.1039\/D5LC00343A","article-title":"Handheld RPA-based molecular POCT system for rapid, low-cost 8-plexed detection of respiratory pathogens at home","volume":"25","author":"Zai","year":"2025","journal-title":"Lab. Chip"},{"key":"B55","doi-asserted-by":"publisher","first-page":"16950","DOI":"10.1021\/ACS.ANALCHEM.5C02447","article-title":"Integrating fluorogenic DNAzymes with photonic crystals for bacterial detection on a microfluidic biochip","volume":"97","author":"Zhang","year":"2025","journal-title":"Anal. Chem."},{"key":"B89","doi-asserted-by":"publisher","first-page":"25583","DOI":"10.1021\/ACS.ANALCHEM.5C04524","article-title":"Amplification-free CRISPR-Cas system integrated centrifugal digital microfluidic platform developed for multiplexed respiratory pathogen nucleic acid analysis","volume":"97","author":"Zhang","year":"2025","journal-title":"Anal. Chem."},{"key":"B70","doi-asserted-by":"publisher","first-page":"131","DOI":"10.3390\/BIOS15030131","article-title":"Microfluidic biosensors for the detection of motile plant zoospores","volume":"15","author":"Zhang","year":"2025","journal-title":"Biosensors"},{"key":"B121","doi-asserted-by":"publisher","DOI":"10.1016\/j.bios.2024.116397","article-title":"Phosphorylation-amplified synchronized droplet microfluidics sensitizes bacterial growth kinetic real-time monitoring","volume":"259","author":"Zhong","year":"2024","journal-title":"Biosens. Bioelectron."},{"key":"B77","doi-asserted-by":"publisher","DOI":"10.1016\/J.BIOS.2025.117850","article-title":"CRISPR\/Cas13a-driven lateral flow assay for preamplification-free and ultrasensitive miRNA-21 detection","volume":"28","author":"Zhu","year":"2025","journal-title":"Biosens. Bioelectron."},{"key":"B100","doi-asserted-by":"publisher","DOI":"10.1016\/J.TALANTA.2024.126155","article-title":"A pump-free paper\/PDMS hybrid microfluidic chip for bacteria enrichment and fast detection","volume":"27","author":"Zhu","year":"2024","journal-title":"Talanta"},{"key":"B92","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1039\/d0lc00830c","article-title":"Growth amplification in ultrahigh-throughput microdroplet screening increases sensitivity of clonal enzyme assays and minimizes phenotypic variation","volume":"21","author":"Zurek","year":"2021","journal-title":"Lab. Chip"}],"container-title":["Frontiers in Cellular and Infection Microbiology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcimb.2026.1819856\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T05:30:27Z","timestamp":1778477427000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcimb.2026.1819856\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,11]]},"references-count":117,"alternative-id":["10.3389\/fcimb.2026.1819856"],"URL":"https:\/\/doi.org\/10.3389\/fcimb.2026.1819856","relation":{},"ISSN":["2235-2988"],"issn-type":[{"value":"2235-2988","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,11]]},"article-number":"1819856"}}