{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T04:12:05Z","timestamp":1787026325232,"version":"build-2736575974"},"reference-count":21,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2020,11,30]],"date-time":"2020-11-30T00:00:00Z","timestamp":1606694400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:p>\n                    <jats:bold>Background:<\/jats:bold>\n                    Cardiac arrhythmias are very common but underdiagnosed due to their transient and asymptomatic nature. An optimization of arrhythmia detection would permit to better treat patients and could substantially reduce morbidity and mortality. The SmartCardia ScaAI wireless patch is a novel CE IIa approved, single-lead electrocardiographic (ECG) ambulatory monitor designed for cardiac arrhythmias detection.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Hypothesis:<\/jats:bold>\n                    The accuracy of the new SmartCardia wireless patch to detect arrhythmias is comparable to the conventional Holter monitoring.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Methods:<\/jats:bold>\n                    Patients referred for a suspicion of arrhythmia between February and March 2020 were included in the trial. Simultaneous ambulatory ECG were recorded using a conventional 24-h Holter and the SmartCardia. The primary endpoint was the detection of cardiac arrhythmias over the total wear time of the devices, defined as premature atrial contraction (PAC), supraventricular tachycardia \u22653 beats, premature ventricular contraction (PVC), and ventricular tachycardia \u22653 beats. Conduction abnormalities, pause \u22652 s and atrioventricular block (AVB), were also tracked. McNemar's test was used to compare the matched pairs of data from both devices.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Results:<\/jats:bold>\n                    A total of 40 patients were included in the trial. Over the total wear time, there was no significant difference between the devices for ventricular and supraventricular arrhythmias detection. Pauses and AVB were equally identified by the two devices in three patients.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Conclusion:<\/jats:bold>\n                    Over the total wear time, the SmartCardia device showed an accuracy to detect arrhythmia similar to the 24-h Holter monitoring: single-lead, adhesive-patch monitoring might become an interesting alternative to the conventional Holter monitoring.\n                  <\/jats:p>","DOI":"10.3389\/fcvm.2020.587945","type":"journal-article","created":{"date-parts":[[2020,11,29]],"date-time":"2020-11-29T23:39:38Z","timestamp":1606693178000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":14,"title":["Cardiac Ambulatory Monitoring: New Wireless Device Validated Against Conventional Holter Monitoring in a Case Series"],"prefix":"10.3389","volume":"7","author":[{"given":"Srinivasan","family":"Murali","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicolas","family":"Brugger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francisco","family":"Rincon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manoj","family":"Mashru","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"St\u00e9phane","family":"Cook","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Jacques","family":"Goy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2020,11,30]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1007\/s11886-000-0025-2","article-title":"Stroke prevention in atrial fibrillation","volume":"2","author":"Hart","year":"2000","journal-title":"Curr Cardiol Rep."},{"key":"B2","doi-asserted-by":"publisher","first-page":"1647","DOI":"10.1161\/01.STR.0000131269.69502.d9","article-title":"Usefulness of ambulatory 7-day ECG monitoring for the detection of atrial fibrillation and flutter after acute stroke and transient ischemic attack","volume":"35","author":"Jabaudon","year":"2004","journal-title":"Stroke."},{"key":"B3","doi-asserted-by":"publisher","first-page":"878","DOI":"10.1016\/j.amjcard.2004.12.015","article-title":"First experience with a Mobile Cardiac Outpatient Telemetry (MCOT) system for the diagnosis and management of cardiac arrhythmia","volume":"95","author":"Joshi","year":"2005","journal-title":"Am J Cardiol."},{"key":"B4","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1111\/j.1540-8167.2007.00779.x","article-title":"Utility of mobile cardiac outpatient telemetry for the diagnosis of palpitations, presyncope, syncope, and the assessment of therapy efficacy","volume":"18","author":"Olson","year":"2007","journal-title":"J Cardiovasc Electrophysiol."},{"key":"B5","doi-asserted-by":"publisher","first-page":"1449","DOI":"10.1161\/STROKEAHA.111.676189","article-title":"Occult atrial fibrillation in cryptogenic stroke: detection by 7-day electrocardiogram versus implantable cardiac monitors","volume":"44","author":"Ritter","year":"2013","journal-title":"Stroke."},{"key":"B6","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1111\/j.1540-8167.2006.00729.x","article-title":"The diagnosis of cardiac arrhythmias: a prospective multi-center randomized study comparing mobile cardiac outpatient telemetry versus standard loop event monitoring","volume":"18","author":"Rothman","year":"2007","journal-title":"J Cardiovasc Electrophysiol."},{"key":"B7","doi-asserted-by":"publisher","first-page":"1055","DOI":"10.1016\/j.amjcard.2005.01.025","article-title":"Comparison of autotriggered memory loop recorders versus standard loop recorders versus 24-hour Holter monitors for arrhythmia detection","volume":"95","author":"Reiffel","year":"2005","journal-title":"Am J Cardiol."},{"key":"B8","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1056\/NEJMoa1105575","article-title":"Subclinical atrial fibrillation and the risk of stroke","volume":"366","author":"Healey","year":"2012","journal-title":"New Engl J Med."},{"key":"B9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0002-9343(03)00233-X","article-title":"A prospective randomized comparison of loop recorders versus Holter monitors in patients with syncope or presyncope","volume":"115","author":"Sivakumaran","year":"2003","journal-title":"Am J Med."},{"key":"B10","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1016\/j.amjcard.2019.11.028","article-title":"Comparison of Holter With Zio Patch Electrocardiography Monitoring in Children","volume":"125","author":"Bolourchi","year":"2020","journal-title":"Am J Cardiol."},{"key":"B11","doi-asserted-by":"publisher","first-page":"319","DOI":"10.2217\/fca.14.24","article-title":"Comparing 14-day adhesive patch with 24-h Holter monitoring","volume":"10","author":"Cheung","year":"2014","journal-title":"Fut Cardiol."},{"key":"B12","doi-asserted-by":"publisher","first-page":"S126","DOI":"10.1016\/j.hlc.2016.06.299","article-title":"Diagnostic benefit of 48 hour Holter monitors compared to 24 hour Holter monitors","volume":"25","author":"Collins","year":"2016","journal-title":"Heart Lung Circ."},{"key":"B13","doi-asserted-by":"publisher","first-page":"95 e11","DOI":"10.1016\/j.amjmed.2013.10.003","article-title":"Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring","volume":"127","author":"Barrett","year":"2014","journal-title":"Am J Med."},{"key":"B14","doi-asserted-by":"publisher","first-page":"e10802","DOI":"10.2196\/10802","article-title":"Continuous versus intermittent vital signs monitoring using a wearable, wireless patch in patients admitted to surgical wards: pilot cluster randomized controlled trial","volume":"20","author":"Downey","year":"2018","journal-title":"J Med Int Res."},{"key":"B15","doi-asserted-by":"publisher","first-page":"103515","DOI":"10.1016\/j.ijnurstu.2019.103515","article-title":"Remote wireless vital signs monitoring on the ward for early detection of deteriorating patients: a case series","volume":"104","author":"Posthuma","year":"2020","journal-title":"Int J Nurs Stud."},{"key":"B16","doi-asserted-by":"publisher","first-page":"S182","DOI":"10.1016\/0022-0736(88)90090-8","article-title":"Deriving the 12-lead electrocardiogram from four (EASI) electrodes","volume":"21","author":"Dower","year":"1988","journal-title":"J Electrocardiol."},{"key":"B17","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1054\/jelc.2002.37150","article-title":"Comparison of a new reduced lead set ECG with the standard ECG for diagnosing cardiac arrhythmias and myocardial ischemia","volume":"35","author":"Drew","year":"2002","journal-title":"J Electrocardiol."},{"key":"B18","doi-asserted-by":"publisher","first-page":"1632","DOI":"10.1109\/EMBC.2018.8512569","article-title":"Fully disposable wireless patch sensor for continuous remote patient monitoring","volume":"2018","author":"Selvaraj","year":"2018","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc."},{"key":"B19","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1016\/j.hrthm.2014.11.015","article-title":"Using a novel wireless system for monitoring patients after the atrial fibrillation ablation procedure: the iTransmit study","volume":"12","author":"Tarakji","year":"2015","journal-title":"Heart Rhythm."},{"key":"B20","doi-asserted-by":"publisher","first-page":"881","DOI":"10.1016\/j.jelectrocard.2014.08.012","article-title":"Clinical validation of a low-power and wearable ECG patch for long term full-disclosure monitoring","volume":"47","author":"Torfs","year":"2014","journal-title":"J Electrocardiol."},{"key":"B21","doi-asserted-by":"publisher","first-page":"S97","DOI":"10.1016\/j.injury.2019.11.018","article-title":"Are current wireless monitoring systems capable of detecting adverse events in high-risk surgical patients? A descriptive study","volume":"51","author":"Breteler","year":"2019","journal-title":"Injury."}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2020.587945\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,29]],"date-time":"2020-11-29T23:39:39Z","timestamp":1606693179000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2020.587945\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,11,30]]},"references-count":21,"alternative-id":["10.3389\/fcvm.2020.587945"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2020.587945","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,11,30]]},"article-number":"587945"}}