{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T21:09:46Z","timestamp":1789765786386,"version":"4.0.1"},"reference-count":23,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2021,1,29]],"date-time":"2021-01-29T00:00:00Z","timestamp":1611878400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000274","name":"British Heart Foundation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000274","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:p><jats:bold>Background:<\/jats:bold> Measurement of myocardial T1 is increasingly incorporated into standard cardiovascular magnetic resonance (CMR) protocols, however accuracy may be reduced in patients with metallic cardiovascular implants. Measurement is feasible in segments free from visual artifact, but there may still be off-resonance induced error.<\/jats:p><jats:p><jats:bold>Aim:<\/jats:bold> To quantify off-resonance induced T1 error in patients with metallic cardiovascular implants, and validate a method for error correction for a conventional MOLLI pulse sequence.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> Twenty-four patients with cardiac implantable electronic devices (CIEDs: 46% permanent pacemakers, PPMs; 33% implantable loop recorders, ILRs; and 21% implantable cardioverter-defibrillators, ICDs); and 31 patients with aortic valve replacement (AVR) (45% metallic) were studied. Paired mid-myocardial short-axis MOLLI and single breath-hold off-resonance field maps were acquired at 1.5 T. T1 values were measured by AHA segment, and segments with visual artifact were excluded. T1 correction was applied using a published relationship between off-resonance and T1. The accuracy of the correction was assessed in 10 healthy volunteers by measuring T1 before and after external placement of an ICD generator next to the chest to generate off-resonance.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> T1 values in healthy volunteers with an ICD were underestimated compared to without (967 \u00b1 52 vs. 997 \u00b1 26 ms respectively, <jats:italic>p<\/jats:italic> = 0.0001), but were similar after correction (<jats:italic>p<\/jats:italic> = 0.57, residual difference 2 \u00b1 27 ms). Artifact was visible in 4 \u00b1 12, 42 \u00b1 31, and 53 \u00b1 27% of AHA segments in patients with ILRs, PPMs, and ICDs, respectively. In segments without artifact, T1 was underestimated by 63 ms (interquartile range: 7\u2013143) per patient. The greatest error for patients with ILRs, PPMs and ICDs were 79, 146, and 191 ms, respectively. The presence of an AVR did not generate T1 error.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> Even when there is no visual artifact, there is error in T1 in patients with CIEDs, but not AVRs. Off-resonance field map acquisition can detect error in measured T1, and a correction can be applied to quantify T1 MOLLI accurately.<\/jats:p>","DOI":"10.3389\/fcvm.2021.631366","type":"journal-article","created":{"date-parts":[[2021,1,29]],"date-time":"2021-01-29T05:50:06Z","timestamp":1611899406000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":14,"title":["Measurement of T1 Mapping in Patients With Cardiac Devices: Off-Resonance Error Extends Beyond Visual Artifact but Can Be Quantified and Corrected"],"prefix":"10.3389","volume":"8","author":[{"given":"Anish N.","family":"Bhuva","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas A.","family":"Treibel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"Seraphim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Scully","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kristopher D.","family":"Knott","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jo\u00e3o B.","family":"Augusto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Camilla","family":"Torlasco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katia","family":"Menacho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clement","family":"Lau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kush","family":"Patel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James C.","family":"Moon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Kellman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charlotte H.","family":"Manisty","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2021,1,29]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12968-017-0389-8","article-title":"Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2 and extracellular volume: a consensus statement by the Society for Cardiovascular Magnetic Resonance (SCMR) endorsed by the European Association for Cardiovascular Imagin","volume":"19","author":"Messroghli","year":"2017","journal-title":"J Cardiovasc Magn Reson."},{"key":"B2","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1016\/j.jacc.2017.05.053","article-title":"Magnetic resonance in transthyretin cardiac amyloidosis","volume":"70","author":"Martinez-Naharro","year":"2017","journal-title":"J Am Coll Cardiol."},{"key":"B3","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1161\/CIRCIMAGING.112.000070","article-title":"Identification and assessment of anderson-fabry disease by cardiovascular magnetic resonance noncontrast myocardial T1 mapping","volume":"6","author":"Sado","year":"2013","journal-title":"Circ Cardiovasc Imaging."},{"key":"B4","doi-asserted-by":"publisher","first-page":"e0192890","DOI":"10.1371\/journal.pone.0192890","article-title":"Role of T1 mapping as a complementary tool to T2* for non-invasive cardiac iron overload assessment","volume":"13","author":"Torlasco","year":"2018","journal-title":"PLoS ONE."},{"key":"B5","doi-asserted-by":"publisher","first-page":"864","DOI":"10.1016\/j.hrthm.2013.02.019","article-title":"Impact of the Advisa MRI pacing system on the diagnostic quality of cardiac MR images and contraction patterns of cardiac muscle during scans: advisa MRI randomized clinical multicenter study results","volume":"10","author":"Schwitter","year":"2013","journal-title":"Hear Rhythm."},{"key":"B6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1161\/CIRCIMAGING.115.004025","article-title":"Image quality of cardiac magnetic resonance imaging in patients with an implantable cardioverter defibrillator system designed for the magnetic resonance imaging environment","volume":"9","author":"Schwitter","year":"2016","journal-title":"Circ Cardiovasc Imaging."},{"key":"B7","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1056\/NEJMoa1603265","article-title":"Assessing the risks associated with MRI in patients with a pacemaker or defibrillator","volume":"376","author":"Russo","year":"2017","journal-title":"N Engl J Med."},{"key":"B8","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.ijcard.2019.01.005","article-title":"Clinical impact of cardiovascular magnetic resonance with optimized myocardial scar detection in patients with cardiac implantable devices","volume":"279","author":"Bhuva","year":"2019","journal-title":"Int J Cardiol."},{"key":"B9","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1002\/mrm.20110","article-title":"Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart","volume":"52","author":"Messroghli","year":"2004","journal-title":"Magn Reson Med."},{"key":"B10","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1148\/radiol.14140296","article-title":"Accuracy, precision, and reproducibility of four T1 mapping sequences: a head-to-head comparison of MOLLI. ShMOLLI, SASHA, and SAPPHIRE","volume":"272","author":"Roujol","year":"2014","journal-title":"Radiology."},{"key":"B11","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1186\/1532-429X-15-63","article-title":"Influence of off-resonance in myocardial T1-mapping using SSFP based MOLLI method","volume":"15","author":"Kellman","year":"2013","journal-title":"J Cardiovasc Magn Reson."},{"key":"B12","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1081\/JCMR-100108585","article-title":"Prosthetic heart valves and annuloplasty rings: assessment of magnetic field interactions, heating, and artifacts at 1.5 Tesla","volume":"3","author":"Shellock","year":"2001","journal-title":"J Cardiovasc Magn Reson."},{"key":"B13","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1002\/mrm.22177","article-title":"Robust water\/fat separation in the presence of large field inhomogeneities using a graph cut algorithm","volume":"63","author":"Hernando","year":"2010","journal-title":"Magn Reson Med."},{"key":"B14","doi-asserted-by":"publisher","first-page":"e4030","DOI":"10.1002\/nbm.4030","article-title":"Mapping tissue water T1 in the liver using the MOLLI T1 method in the presence of fat, iron and B0 inhomogeneity","volume":"32","author":"Mozes","year":"2019","journal-title":"NMR Biomed."},{"key":"B15","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1186\/1532-429X-15-56","article-title":"T1 and extracellular volume mapping in the heart: estimation of error maps and the influence of noise on precision","volume":"15","author":"Kellman","year":"2013","journal-title":"J Cardiovasc Magn Reson."},{"key":"B16","doi-asserted-by":"publisher","first-page":"1408","DOI":"10.1002\/mrm.24385","article-title":"Phase-sensitive inversion recovery for myocardial T1 mapping with motion correction and parametric fitting","volume":"69","author":"Xue","year":"2013","journal-title":"Magn Reson Med."},{"key":"B17","doi-asserted-by":"publisher","first-page":"e99","DOI":"10.1016\/j.hrthm.2017.04.025","article-title":"2017 HRS expert consensus statement on magnetic resonance imaging and radiation exposure in patients with cardiovascular implantable electronic devices","volume":"14","author":"Indik","year":"2017","journal-title":"Heart Rhythm"},{"key":"B18","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1002\/jmri.24163","article-title":"Fundamentals of balanced steady state free precession MRI","volume":"38","author":"Bieri","year":"2013","journal-title":"J Magn Reson Imaging."},{"key":"B19","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1093\/ehjci\/jey034","article-title":"Myocardial native T1 and extracellular volume with healthy ageing and gender","volume":"19","author":"Rosmini","year":"2018","journal-title":"Eur Heart J Cardiovasc Imaging."},{"key":"B20","doi-asserted-by":"publisher","first-page":"P2","DOI":"10.1186\/1532-429X-18-S1-P2","article-title":"Reproducibility of native T1 mapping using ShMOLLI and MOLLI - implications for sample size calculation","volume":"18","author":"Bhuva","year":"2016","journal-title":"J Cardiovasc Magn Reson"},{"key":"B21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/mrm.26223","article-title":"Myocardial T1 mapping for patients with implanted cardiac devices using wideband inversion recovery spoiled gradient echo readout","author":"Shao","year":"2016","journal-title":"Magn Reson Med."},{"key":"B22","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1002\/mrm.25712","article-title":"Wideband arrhythmia-Insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by an implantable-cardioverter-defibrillator","volume":"74","author":"Hong","year":"2015","journal-title":"Magn Reson Med."},{"key":"B23","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1002\/mrm.26795","article-title":"Fast, precise, and accurate myocardial T 1 mapping using a radial MOLLI sequence with FLASH readout","volume":"79","author":"Marty","year":"2018","journal-title":"Magn Reson Med."}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2021.631366\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,29]],"date-time":"2021-01-29T05:50:08Z","timestamp":1611899408000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2021.631366\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,29]]},"references-count":23,"alternative-id":["10.3389\/fcvm.2021.631366"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2021.631366","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,29]]},"article-number":"631366"}}