{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,8]],"date-time":"2026-04-08T18:45:24Z","timestamp":1775673924822,"version":"3.50.1"},"reference-count":87,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2021,9,21]],"date-time":"2021-09-21T00:00:00Z","timestamp":1632182400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:p>Diabetes is a complex metabolic disease characterized by hyperglycemia. Its complications are various, often involving the heart, brain, kidney, and other essential organs. At present, the number of diabetic patients in the world is growing day by day. The cardiovascular disease caused by diabetes has dramatically affected the quality of life of diabetic patients. It is the leading cause of death of diabetic patients. Diabetic patients often suffer from microvascular angina pectoris without obstructive coronary artery disease. Still, there are typical ECG ischemia and angina pectoris, that is, chest pain and dyspnea under exercise. Unlike obstructive coronary diseases, nitrate does not affect chest pain caused by coronary microvascular angina in most cases. With the increasing emphasis on diabetic microvascular angina, the need for accurate diagnosis of the disease is also increasing. We can use SPECT, PET, CMR, MCE, and other methods to evaluate coronary microvascular function. SPECT is commonly used in clinical practice, and PET is considered the gold standard for non-invasive detection of myocardial blood flow. This article mainly introduces the research progress of these imaging methods in detecting microvascular angina in diabetic patients.<\/jats:p>","DOI":"10.3389\/fcvm.2021.713971","type":"journal-article","created":{"date-parts":[[2021,9,21]],"date-time":"2021-09-21T04:47:50Z","timestamp":1632199670000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["Research Progress of Imaging Methods for Detection of Microvascular Angina Pectoris in Diabetic Patients"],"prefix":"10.3389","volume":"8","author":[{"given":"Yiming","family":"Qi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lihua","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guoquan","family":"Feng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chen","family":"Shao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yue","family":"Cai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhongqun","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2021,9,21]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1901","DOI":"10.1177\/0300060516675504","article-title":"Coronary microvascular dysfunction in diabetes mellitus","volume":"45","author":"Kibel","year":"2017","journal-title":"J Int Med Res."},{"key":"B2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1136\/bmjdrc-2020-001847","article-title":"Prevalence and incidence of microvascular and macrovascular complications over 15 years among patients with incident type 2 diabetes","volume":"9","author":"An","year":"2021","journal-title":"BMJ Open Diabetes Res Care."},{"key":"B3","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1016\/S0002-9149(73)80150-X","article-title":"Left ventricular function in patients with the anginal syndrome and normal coronary arteriograms","volume":"32","author":"Kemp","year":"1973","journal-title":"Am J Cardiol."},{"key":"B4","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1007\/s00125-015-3799-x","article-title":"Cardiac 82Rb PET\/CT for fast and non-invasive assessment of microvascular function and structure in asymptomatic patients with type 2 diabetes","volume":"59","author":"von Scholten","year":"2016","journal-title":"Diabetologia."},{"key":"B5","doi-asserted-by":"publisher","first-page":"119","DOI":"10.4330\/wjc.v7.i3.119","article-title":"Coronary artery disease in type 2 diabetes mellitus: recent treatment strategies and future perspectives","volume":"7","author":"Naito","year":"2015","journal-title":"World J Cardiol."},{"key":"B6","doi-asserted-by":"publisher","first-page":"H1339","DOI":"10.1152\/ajpheart.00458.2015","article-title":"Coronary microvascular dysfunction after long-term diabetes and hypercholesterolemia","volume":"311","author":"Sorop","year":"2016","journal-title":"Am J Physiol Hear Circ Physiol."},{"key":"B7","doi-asserted-by":"publisher","first-page":"631","DOI":"10.2337\/db18-0650","article-title":"Sex differences in coronary microvascular function in individuals with type 2 diabetes","volume":"68","author":"Haas","year":"2019","journal-title":"Diabetes."},{"key":"B8","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1016\/S0735-1097(16)30269-8","article-title":"Prevalence and predictors of coronary microvascular dysfunction among patients with ischemia and non-obstructive CAD","volume":"67","author":"Sattar","year":"2016","journal-title":"J Am Coll Cardiol."},{"key":"B9","doi-asserted-by":"publisher","DOI":"10.2463\/mrms.rev.2021-0033","article-title":"Advances in myocardial perfusion MR imaging: physiological implications, the importance of quantitative analysis, and impact on patient care in coronary artery disease","author":"Sakuma","year":"2021","journal-title":"Magn Reson Med Sci."},{"key":"B10","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/S0002-8703(98)70194-2","article-title":"Current concepts of coronary flow reserve for clinical decision making during cardiac catheterization","volume":"136","author":"Baumgart","year":"1998","journal-title":"Interv Cardiol."},{"key":"B11","doi-asserted-by":"publisher","first-page":"2625","DOI":"10.1016\/j.jacc.2018.09.042","article-title":"Coronary microvascular disease pathogenic mechanisms and therapeutic options","volume":"72","author":"Taqueti","year":"2018","journal-title":"J Am Coll Cardiol."},{"key":"B12","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1016\/S0735-1097(03)00166-9","article-title":"Role of chronic hyperglycemia in the pathogenesis of coronary microvascular dysfunction in diabetes","volume":"41","author":"Di Carli","year":"2003","journal-title":"J Am Coll Cardiol."},{"key":"B13","first-page":"258","article-title":"Microvascular Disease in Diabetes","author":"Tecilazich","year":"2020"},{"key":"B14","doi-asserted-by":"publisher","first-page":"377","DOI":"10.4330\/wjc.v2.i11.377","article-title":"Coronary microvascular dysfunction in diabetes mellitus: a review","volume":"2","author":"Picchi","year":"2010","journal-title":"World J Cardiol."},{"key":"B15","doi-asserted-by":"publisher","first-page":"110641","DOI":"10.1016\/j.mce.2019.110641","article-title":"The NF-\u03baB\/miR-425-5p\/MCT4 axis: a novel insight into diabetes-induced endothelial dysfunction","volume":"500","author":"Luo","year":"2019","journal-title":"Mol Cell Endocrinol."},{"key":"B16","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehab282","article-title":"Clinical characteristics and prognosis of patients with microvascular angina: an international and prospective cohort study by the coronary vasomotor disorders international study (COVADIS) group","author":"Shimokawa","year":"2021","journal-title":"Eur Heart J."},{"key":"B17","doi-asserted-by":"publisher","first-page":"830","DOI":"10.1056\/NEJMc070666","article-title":"Coronary microvascular dysfunction","volume":"356","author":"Camici","year":"2007","journal-title":"N Engl J Med."},{"key":"B18","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.ijcard.2017.08.068","article-title":"International standardization of diagnostic criteria for microvascular angina","volume":"250","author":"Ong","year":"2017","journal-title":"Int J Cardiol."},{"key":"B19","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1016\/j.yjmcc.2011.08.028","article-title":"The coronary circulation and blood flow in left ventricular hypertrophy","volume":"52","author":"Camici","year":"2012","journal-title":"J Mol Cell Cardiol."},{"key":"B20","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1016\/j.jcin.2014.01.157","article-title":"Angina pectoris and myocardial ischemia in the absence of obstructive coronary artery disease: practical considerations for diagnostic tests","volume":"7","author":"Radico","year":"2014","journal-title":"Jacc Cardiov Interv."},{"key":"B21","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1016\/j.ijcard.2020.02.038","article-title":"Microvascular function, diabetes and coronary risk - ScienceDirect","volume":"307","author":"Guti\u00e9rrez","year":"2020","journal-title":"Int J Cardiol."},{"key":"B22","doi-asserted-by":"publisher","first-page":"e003995","DOI":"10.1161\/JAHA.116.003995","article-title":"Bimodal pattern of coronary microvascular involvement in diabetes mellitus","volume":"5","author":"Sezer","year":"2016","journal-title":"J Am Heart Assoc."},{"key":"B23","doi-asserted-by":"publisher","first-page":"1858","DOI":"10.1161\/CIRCULATIONAHA.112.120402","article-title":"Association between coronary vascular dysfunction and cardiac mortality in patients with and without diabetes mellitus","volume":"126","author":"Murthy","year":"2012"},{"key":"B24","doi-asserted-by":"publisher","first-page":"e006427","DOI":"10.1161\/CIRCIMAGING.117.006427","article-title":"Quantitative assessment of coronary microvascular function","volume":"10","author":"Feher","year":"2017","journal-title":"Circ Cardiov Imag."},{"key":"B25","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1186\/CVM-1-1-031","article-title":"Importance of the TIMI frame count: implications for future trials","volume":"1","author":"Appleby","year":"2000","journal-title":"Curr Control Trials Cardiovasc Med."},{"key":"B26","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1007\/s11239-008-0220-3","article-title":"Use of the TIMI frame count in the assessment of coronary artery blood flow and microvascular function over the past 15 years","volume":"27","author":"Kunadian","year":"2009","journal-title":"J Thromb Thrombol."},{"key":"B27","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1002\/ccd.22298","article-title":"TIMI myocardial perfusion frame count: a new method to assess myocardial perfusion and its predictive value for short-term prognosis","volume":"75","author":"Ding","year":"2009","journal-title":"Catheterizat Cardiovasc Inte"},{"key":"B28","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1016\/j.ijcard.2015.10.194","article-title":"Frame counting improves the assessment of post-reperfusion microvascular patency by TIMI myocardial perfusion grade: evidence from cardiac magnetic resonance imaging","volume":"203","author":"Ge","year":"2015","journal-title":"Int J Cardiol."},{"key":"B29","doi-asserted-by":"publisher","first-page":"855","DOI":"10.1007\/s00259-005-1779-y","article-title":"EANM\/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology","volume":"32","author":"Hesse","year":"2005","journal-title":"Eur J Nucl Med Mol Imag."},{"key":"B30","doi-asserted-by":"publisher","first-page":"1960","DOI":"10.1007\/s12350-017-1023-8","article-title":"PET should not replace routine SPECT MPS for the assessment of patients with known or suspected CAD","volume":"24","author":"Stirrup","year":"2017","journal-title":"J Nucl Cardiol."},{"key":"B31","doi-asserted-by":"publisher","first-page":"156","DOI":"10.4103\/1450-1147.163241","article-title":"Development of scintillators in nuclear medicine","volume":"14","author":"Khoshakhlagh","year":"2015","journal-title":"World J Nucl Med."},{"key":"B32","doi-asserted-by":"publisher","first-page":"1280","DOI":"10.1007\/s12350-018-1242-7","article-title":"Dual isotope stress Tl-201 and rest Tc-99m CZT SPECT: are we truly leveraging CZT technology?","volume":"26","author":"Malhotra","year":"2018","journal-title":"J Nucl Cardiol."},{"key":"B33","doi-asserted-by":"publisher","first-page":"1009","DOI":"10.1007\/s12350-010-9215-5","article-title":"Reduced isotope dose with rapid SPECT MPI imaging: initial experience with a CZT SPECT camera","volume":"17","author":"Duvall","year":"2010","journal-title":"J Nucl Cardiol."},{"key":"B34","doi-asserted-by":"publisher","first-page":"373","DOI":"10.2967\/jnumed.112.110601","article-title":"Myocardial perfusion imaging with a solid-state camera: simulation of a very low dose imaging protocol","volume":"54","author":"Nakazato","year":"2013","journal-title":"J Nucl Med."},{"key":"B35","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1007\/s12350-019-01678-z","article-title":"Absolute myocardial blood flows derived by dynamic CZT scan vs invasive fractional flow reserve: correlation and accuracy","volume":"28","author":"Zavadovsky","year":"2021","journal-title":"J Nucl Cardiol."},{"key":"B36","doi-asserted-by":"publisher","DOI":"10.1007\/s12350-020-02129-w.","article-title":"Quantification of myocardial perfusion reserve by CZT-SPECT: a head to head comparison with 82 rubidium PET imaging","author":"Acampa","year":"2020","journal-title":"J Nucl Cardiol."},{"key":"B37","doi-asserted-by":"publisher","DOI":"10.1007\/s12350-019-01854-1.","article-title":"Quantification of myocardial blood flow by CZT-SPECT with motion correction and comparison with 15O-water PET","author":"Otaki","year":"2019","journal-title":"J Nucl Cardiol"},{"key":"B38","doi-asserted-by":"publisher","first-page":"748","DOI":"10.1007\/s12350-018-01522-w","article-title":"Simultaneous dual isotope (201)Tl\/(99m)Tc myocardial perfusion imaging using CZT cameras: clinical utility or technical challenge?","volume":"27","author":"Zampella","year":"2020","journal-title":"J Nucl Cardiol."},{"key":"B39","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1007\/s12350-018-1452-z","article-title":"Feasibility of simultaneous dual isotope acquisition for myocardial perfusion imaging with a cadmium zinc telluride camera","volume":"27","author":"Songy","year":"2020","journal-title":"J Nucl Cardiol."},{"key":"B40","doi-asserted-by":"publisher","first-page":"1242","DOI":"10.1007\/s12350-018-1194-y","article-title":"Radiopharmaceuticals for cardiac imaging: current status and future trends","volume":"25","author":"Taillefer","year":"2018","journal-title":"J Nucl Cardiol."},{"key":"B41","doi-asserted-by":"publisher","first-page":"4493","DOI":"10.1002\/mp.13099","article-title":"Comparison of sparse domain approaches for 4D SPECT dynamic image reconstruction","volume":"45","author":"Debasis","year":"2018","journal-title":"Med Phys."},{"key":"B42","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.ejmp.2021.03.008","article-title":"The promise of artificial intelligence and deep learning in PET and SPECT imaging","volume":"83","author":"Arabi","year":"2021","journal-title":"Physica Medica."},{"key":"B43","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1007\/s11886-019-1096-x","article-title":"Quantification of PET myocardial blood flow","volume":"21","author":"Pelletier-Galarneau","year":"2019","journal-title":"Curr Cardiol Rep."},{"key":"B44","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1007\/s11936-017-0591-x","article-title":"Role of cardiac PET in clinical practice","volume":"19","author":"Salata","year":"2017","journal-title":"Curr Treat Options Cardiovasc Med."},{"key":"B45","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1007\/s11886-020-01287-0","article-title":"SPECT versus PET myocardial perfusion imaging in patients with equivocal CT","volume":"22","author":"Singh","year":"2020","journal-title":"Curr Cardiol Rep."},{"key":"B46","doi-asserted-by":"publisher","first-page":"S3","DOI":"10.1007\/s12350-011-9490-9","article-title":"Advantages and disadvantages of PET and SPECT in a busy clinical practice","volume":"19","author":"Bateman","year":"2012","journal-title":"J Nucl Cardiol Offic Public Am Soc Nucl Cardiol."},{"key":"B47","doi-asserted-by":"publisher","first-page":"478","DOI":"10.3760\/cma.j.issn.2095-2848.2019.08.007","article-title":"Value of PET quantitative analysis of coronary physiology for the diagnosis and risk factors assess- ment of non-obstructive coronary microvascular disease","volume":"39","author":"Wanli","year":"2019","journal-title":"Chin J Nucl Med Mol Imagin."},{"key":"B48","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1161\/CIRCULATIONAHA.114.011939","article-title":"Global coronary flow reserve is associated with adverse cardiovascular events independently of luminal angiographic severity and modifies the effect of early revascularization","volume":"131","author":"Taqueti","year":"2015","journal-title":"Circulation."},{"key":"B49","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1007\/s11886-020-01368-0","article-title":"Emerging F-18-labelled PET myocardial perfusion tracers","volume":"22","author":"Liga","year":"2020","journal-title":"Curr Cardiol Rep."},{"key":"B50","first-page":"200","article-title":"Searching for novel PET radiotracers: imaging","volume":"8","author":"Davidson","year":"2018","journal-title":"Am J Nucl Med Mol Imag."},{"key":"B51","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1007\/s10554-018-1469-z","article-title":"Moving into the next era of PET myocardial perfusion imaging: introduction of novel 18F-labeled tracers","volume":"35","author":"Werner","year":"2018","journal-title":"Int J Cardiovasc Imag."},{"key":"B52","doi-asserted-by":"publisher","first-page":"504532","DOI":"10.1155\/2014\/504532","article-title":"Advanced tracers in PET imaging of cardiovascular disease","volume":"2014","author":"Li","year":"2014","journal-title":"Bio Res Int."},{"key":"B53","doi-asserted-by":"publisher","DOI":"10.1089\/cbr.2020.4716.","article-title":"Likely common role of hypoxia in driving (18)F-FDG uptake in cancer, myocardial ischemia, inflammation and infection","author":"Yao","year":"2021","journal-title":"Can Biother Radiopharm"},{"key":"B54","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1053\/j.semnuclmed.2014.06.010","article-title":"Cardiac hot spot imaging with (18)FDG","volume":"44","author":"Jain","year":"2014","journal-title":"Semin Nucl Med."},{"key":"B55","doi-asserted-by":"publisher","first-page":"892","DOI":"10.7507\/1001-5515.202005003","article-title":"Advancement of imaging technology for coronary microcirculation dysfunction assessment","volume":"37","author":"Bowei","year":"2020","journal-title":"J Bio Eng"},{"key":"B56","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1016\/j.nucmedbio.2016.04.004","article-title":"Efficient radiosynthesis and non-clinical safety tests of the TSPO radioprobe [18F]FEDAC: prerequisites for clinical application","volume":"43","author":"Kawamura","year":"2016","journal-title":"Nucl Med Biol."},{"key":"B57","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1007\/s12149-021-01630-7","article-title":"[18F]FEDAC translocator protein positron emission tomography\u2013computed tomography for early detection of mitochondrial dysfunction secondary to myocardial ischemia","volume":"35","author":"Luo","year":"2021","journal-title":"Ann Nucl Med"},{"key":"B58","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1016\/j.crad.2014.12.017","article-title":"Measuring myocardial perfusion: the role of PET, MRI and CT","volume":"70","author":"Qayyum","year":"2015","journal-title":"Clin Radiol."},{"key":"B59","doi-asserted-by":"publisher","first-page":"768","DOI":"10.1097\/MNM.0000000000001218","article-title":"Validation of regional myocardial blood flow quantification using three-dimensional PET with rubidium-82: repeatability and comparison with two-dimensional PET data acquisition","volume":"41","author":"Manabe","year":"2020","journal-title":"Nucl Med Commun."},{"key":"B60","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/j.hlc.2019.05.187","article-title":"Assessing coronary microvascular dysfunction in ischaemic heart disease: little things can make a big difference","volume":"29","author":"Xu","year":"2019","journal-title":"Heart Lung Circ."},{"key":"B61","doi-asserted-by":"publisher","first-page":"1958","DOI":"10.1016\/j.jcmg.2018.12.022","article-title":"Automated pixel-wise quantitative myocardial perfusion mapping by CMR to detect obstructive coronary artery disease and coronary microvascular dysfunction","volume":"12","author":"Kotecha","year":"2019","journal-title":"JACC Cardiovasc Imag"},{"key":"B62","doi-asserted-by":"publisher","first-page":"1686","DOI":"10.1016\/j.jcmg.2018.08.018","article-title":"Global coronary flow reserve measured during stress cardiac magnetic resonance imaging is an independent predictor of adverse cardiovascular events","volume":"12","author":"Indorkar","year":"2019","journal-title":"JACC Cardiovasc Imag."},{"key":"B63","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1186\/s12968-018-0435-1","article-title":"Quantitative cardiovascular magnetic resonance perfusion imaging identifies reduced flow reserve in microvascular coronary artery disease","volume":"20","author":"Zorach","year":"2018","journal-title":"J Cardiovasc Mag Res."},{"key":"B64","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1186\/s12968-017-0397-8","article-title":"Adenosine stress CMR T1-mapping detects early microvascular dysfunction in patients with type 2 diabetes mellitus without obstructive coronary artery disease","volume":"19","author":"Levelt","year":"2017","journal-title":"J Cardiovasc Mag Res."},{"key":"B65","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1016\/j.jacc.2017.11.071","article-title":"RETRACTED: gadolinium-free cardiac MR stress T1-mapping to distinguish epicardial from microvascular coronary disease","volume":"71","author":"Liu","year":"2018","journal-title":"J Am Coll Cardiol."},{"key":"B66","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1007\/s00392-019-01530-x","article-title":"\u201cMyocardial transit-time\u201d (MyoTT): a novel and easy-to-perform CMR parameter to assess microvascular disease","volume":"109","author":"Chatzantonis","year":"2020","journal-title":"Clin Res Cardiol"},{"key":"B67","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1007\/s00392-020-01661-6","article-title":"Diagnostic value of the novel CMR parameter \u201cmyocardial transit-time\u201d (MyoTT) for the assessment of microvascular changes in cardiac amyloidosis and hypertrophic cardiomyopathy","volume":"110","author":"Chatzantonis","year":"2021","journal-title":"Clin Res Cardiol."},{"key":"B68","doi-asserted-by":"publisher","first-page":"602","DOI":"10.1016\/j.jcmg.2020.09.034","article-title":"Long-term prognosis of patients with coronary microvascular disease using stress perfusion cardiac magnetic resonance","volume":"14","author":"Zhou","year":"2020","journal-title":"JACC Cardiovasc Imag"},{"key":"B69","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1016\/j.carj.2014.08.001","article-title":"Canadian heart rhythm society and Canadian association of radiologists consensus statement on magnetic resonance imaging with cardiac implantable electronic devices","volume":"65","author":"Verma","year":"2014","journal-title":"Can Assoc Radiol J."},{"key":"B70","doi-asserted-by":"publisher","first-page":"978","DOI":"10.1016\/j.jcmg.2020.10.015","article-title":"High-resolution cardiac magnetic resonance imaging techniques for the identification of coronary microvascular dysfunction","volume":"14","author":"Rahman","year":"2021","journal-title":"JACC Cardiovasc Imag"},{"key":"B71","doi-asserted-by":"publisher","first-page":"98","DOI":"10.2463\/mrms.mp.2015-0104","article-title":"Doppler ultrasound triggering for cardiovascular MRI at 3T in a healthy volunteer study","volume":"16","author":"Kording","year":"2017","journal-title":"Mag Res Med Sci."},{"key":"B72","doi-asserted-by":"publisher","first-page":"2974","DOI":"10.1021\/acs.molpharmaceut.1c00145","article-title":"Biomimetic PLGA microbubbles coated with platelet membranes for early detection of myocardial ischaemia-reperfusion injury","volume":"18","author":"Xu","year":"2021","journal-title":"Mol Pharmac."},{"key":"B73","doi-asserted-by":"publisher","first-page":"1362","DOI":"10.1016\/j.jacc.2013.05.053","article-title":"Myocardial contrast echocardiography perfusion imaging","volume":"62","author":"Thomas","year":"2013","journal-title":"J Am Coll Cardiol."},{"key":"B74","doi-asserted-by":"publisher","first-page":"861","DOI":"10.4330\/wjc.v7.i12.861","article-title":"Myocardial perfusion echocardiography and coronary microvascular dysfunction","volume":"7","author":"Barletta","year":"2015","journal-title":"World J Cardiol."},{"key":"B75","doi-asserted-by":"publisher","first-page":"e15990","DOI":"10.1097\/MD.0000000000015990","article-title":"Microcirculation function assessed by adenosine triphosphate stress myocardial contrast echocardiography and prognosis in patients with nonobstructive coronary artery disease","volume":"98","author":"Yang","year":"2019","journal-title":"Medicine."},{"key":"B76","doi-asserted-by":"publisher","first-page":"1354","DOI":"10.1016\/j.jacc.2007.06.027","article-title":"Additional prognostic value of coronary flow reserve in diabetic and nondiabetic patients with negative dipyridamole stress echocardiography by wall motion criteria","volume":"50","author":"Cortigiani","year":"2007","journal-title":"J Am Coll Cardiol."},{"key":"B77","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1016\/j.echo.2020.03.016","article-title":"Flow augmentation in the myocardium by ultrasound cavitation of microbubbles: role of shear-mediated purinergic signaling","volume":"33","author":"Moccetti","year":"2020","journal-title":"J Am Soc Echocardiog"},{"key":"B78","doi-asserted-by":"publisher","first-page":"1535","DOI":"10.3389\/fphar.2019.01535","article-title":"Assessment of the preventive effect against diabetic cardiomyopathy of FGF1-loaded nanoliposomes combined with microbubble cavitation by ultrasound","volume":"10","author":"Lei","year":"2020","journal-title":"Front Pharmacol"},{"key":"B79","doi-asserted-by":"publisher","first-page":"679","DOI":"10.3390\/diagnostics10090679","article-title":"Coronary microvascular dysfunction and the role of noninvasive cardiovascular imaging","volume":"10","author":"Ayub","year":"2020","journal-title":"Diagnostics."},{"key":"B80","doi-asserted-by":"publisher","first-page":"1271","DOI":"10.1016\/j.jacc.2012.12.029","article-title":"Transluminal attenuation gradient in coronary computed tomography angiography is a novel noninvasive approach to the identification of functionally significant coronary artery stenosis: a comparison with fractional flow reserve","volume":"61","author":"Wong","year":"2013","journal-title":"J Am Coll Cardiol."},{"key":"B81","doi-asserted-by":"publisher","first-page":"1253","DOI":"10.1007\/s00330-017-5057-8","article-title":"CT myocardial perfusion imaging: ready for prime time?","volume":"28","author":"Takx","year":"2018","journal-title":"Eur Radiol."},{"key":"B82","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1016\/j.ijcard.2021.04.055","article-title":"Prevalence and disease features of myocardial ischemia with non-obstructive coronary arteries: insights from a dynamic CT myocardial perfusion imaging study","volume":"334","author":"Xu","year":"2021","journal-title":"Int J Cardiol."},{"key":"B83","doi-asserted-by":"publisher","first-page":"97","DOI":"10.3348\/kjr.2020.0249","article-title":"Dynamic CT myocardial perfusion imaging in patients without obstructive coronary artery disease: quantification of myocardial blood flow according to varied heart rate increments after stress","volume":"22","author":"Yu","year":"2021","journal-title":"Korean J Radiol."},{"key":"B84","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1016\/j.jcmg.2011.09.006","article-title":"Intracoronary transluminal attenuation gradient in coronary CT angiography for determining coronary artery stenosis","volume":"4","author":"Choi","year":"2011","journal-title":"JACC: Cardiovasc Imag."},{"key":"B85","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1007\/s00380-020-01712-y","article-title":"New transluminal attenuation gradient derived from dynamic coronary CT angiography: diagnostic ability of ischemia detected by 13N-ammonia PET","volume":"36","author":"Kojima","year":"2021","journal-title":"Heart Vessels."},{"key":"B86","doi-asserted-by":"publisher","first-page":"804","DOI":"10.1007\/s12350-013-9739-6","article-title":"Epicardial adipose tissue thickness as a predictor of impaired microvascular function in patients with non-obstructive coronary artery disease","volume":"20","author":"Alam","year":"2013","journal-title":"J Nucl Cardiol."},{"key":"B87","doi-asserted-by":"publisher","DOI":"10.21203\/rs.3.rs-495125\/v1","article-title":"Assessment of non-invasive diagnostic imaging modalities efficiency for detecting myocardial ischemia in patients suspected of having stable angina","author":"Iwata","year":"2021","journal-title":"Preprint"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2021.713971\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,21]],"date-time":"2021-09-21T04:47:55Z","timestamp":1632199675000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2021.713971\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,21]]},"references-count":87,"alternative-id":["10.3389\/fcvm.2021.713971"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2021.713971","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,21]]},"article-number":"713971"}}