{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,9]],"date-time":"2025-09-09T20:35:46Z","timestamp":1757450146773,"version":"3.41.2"},"reference-count":10,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2021,8,18]],"date-time":"2021-08-18T00:00:00Z","timestamp":1629244800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:p>The role of cardiac computed tomography in the evaluation of patients for transcatheter aortic valve implantation is well-established. However, its role in the evaluation of anomalous vessels in the pre-procedure planning, intra-procedural fusion imaging and post-procedure assessment of vessel patency is not yet defined. This case report illustrates the utility of cardiac CT throughout the management of complex structural interventions. Here, we describe an anomalous left coronary artery where the course of the anomalous vessel and its proximity to the aortic valve annulus is defined allowing the selection of the most appropriate balloon expandable valve with a planned deployment. Upon follow up, patency of this anomalous vessel is ascertained using CT as well as the transcatheter valve function and leaflet thickening.<\/jats:p>","DOI":"10.3389\/fcvm.2021.721363","type":"journal-article","created":{"date-parts":[[2021,8,18]],"date-time":"2021-08-18T07:21:29Z","timestamp":1629271289000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":5,"title":["Case Report: Transcatheter Aortic Valve Replacement in a Patient With Severe Aortic Stenosis, Left Ventricular Dysfunction, and an Anomalous Left Circumflex Artery"],"prefix":"10.3389","volume":"8","author":[{"given":"Badreyah","family":"Aldauig","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammed","family":"El-Sabbah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mirvat","family":"Alasnag","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2021,8,18]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"iv65","DOI":"10.1136\/heartjnl-2012-302393","article-title":"Transcatheter aortic valve implantation: the evidence","volume":"98","author":"Sinning","year":"2012","journal-title":"Heart"},{"key":"B2","doi-asserted-by":"publisher","first-page":"2130","DOI":"10.1016\/j.jacc.2011.08.050","article-title":"Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the UK TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry","volume":"58","author":"Moat","year":"2011","journal-title":"J Am Coll Cardiol."},{"key":"B3","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1016\/j.jcmg.2011.01.014","article-title":"Multidetector computed tomography in transcatheter aortic valve implantation","author":"Leipsic","year":"2011","journal-title":"JACC Cardiovasc Imag."},{"key":"B4","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1016\/j.jcct.2012.11.002","article-title":"expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)\/transcatheter aortic valve replacement (TAVR)","volume":"6","author":"Achenbach","year":"2012","journal-title":"J Cardiovasc Comput Tomogr."},{"key":"B5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jcct.2018.11.008","article-title":"Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI)\/ transcatheter aortic valve replacement (TAVR): An expert consensus document of the Society of Cardiovascular Computed Tomography","volume":"13","author":"Blanke","year":"2019","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1227","DOI":"10.1002\/ccd.26541","article-title":"A case of anomalous left coronary artery obstruction caused by Lotus Valve implanation","volume":"90","author":"Mizote","year":"2017","journal-title":"Catheter Cardiovasc Interv."},{"key":"B7","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.1016\/j.jcin.2020.02.005","article-title":"Alignment of transcatheter aortic-valve neo-commissures (ALIGN TAVR): impact on final valve orientation and coronary artery overlap","volume":"13","author":"Tang","year":"2020","journal-title":"JACC Cardiovasc Interv"},{"key":"B8","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1002\/ccd.28695","article-title":"Assessing the risk of an anomalous circumflex artery using balloon aortic valvuloplasty prior to transcatheter aortic valve replacement","volume":"96","author":"Tabachnick","year":"2020","journal-title":"Catheter Cardiovasc Interv"},{"key":"B9","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.jcmg.2013.10.009","article-title":"CT angiography-fluoroscopy fusion imaging for percutaneous transapical access","volume":"7","author":"Kliger","year":"2014","journal-title":"JACC Cardiovasc Imag"},{"key":"B10","doi-asserted-by":"publisher","first-page":"2263","DOI":"10.1093\/eurheartj\/ehv526","article-title":"Early hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valves","volume":"37","author":"Pache","year":"2016","journal-title":"Eur Heart J"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2021.721363\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,18]],"date-time":"2021-08-18T07:21:33Z","timestamp":1629271293000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2021.721363\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,18]]},"references-count":10,"alternative-id":["10.3389\/fcvm.2021.721363"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2021.721363","relation":{},"ISSN":["2297-055X"],"issn-type":[{"type":"electronic","value":"2297-055X"}],"subject":[],"published":{"date-parts":[[2021,8,18]]},"article-number":"721363"}}