{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T08:11:17Z","timestamp":1791879077706,"version":"4.3.4"},"reference-count":21,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2021,11,30]],"date-time":"2021-11-30T00:00:00Z","timestamp":1638230400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:p><jats:bold>Introduction:<\/jats:bold> For patients who develop atrioventricular block (AVB) following transcatheter aortic valve replacement (TAVR), right ventricular pacing (RVP) may be associated with adverse outcomes. We assessed the feasibility of conduction system pacing (CSP) in patients who developed AVB following TAVR and compared the procedural and clinical outcomes with RVP.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> Consecutive patients who developed AVB following TAVR were prospectively enrolled, and were implanted with RVP or CSP. Procedural and clinical outcomes were compared among different pacing modalities.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> A total of 60 patients were enrolled, including 10 who were implanted with His bundle pacing (HBP), 20 with left bundle branch pacing (LBBP), and 30 with RVP. The HBP group had significantly lower implant success rate, higher capture threshold, and lower R-wave amplitude than the LBBP and RVP groups (<jats:italic>p<\/jats:italic> &amp;lt; 0.01, respectively). The RVP group had a significantly longer paced QRS duration (153.5 \u00b1 6.8 ms, <jats:italic>p<\/jats:italic> &amp;lt; 0.01) than the other two groups (HBP: 121.8 \u00b1 8.6 ms; LBBP: 120.2 \u00b1 10.6 ms). During a mean follow-up of 15.0 \u00b1 9.1 months, the LBBP group had significantly higher left ventricular ejection fraction (LVEF) (54.9 \u00b1 6.7% vs. 48.9 \u00b1 9.1%, <jats:italic>p<\/jats:italic> &amp;lt; 0.05) and shorter left ventricular end-diastolic diameter (LVEDD) (49.7 \u00b1 5.6 mm vs. 55.0 \u00b1 7.7 mm, <jats:italic>p<\/jats:italic> &amp;lt; 0.05) than the RVP group. While the HBP group showed trends of higher LVEF (<jats:italic>p<\/jats:italic> = 0.016) and shorter LVEDD (<jats:italic>p<\/jats:italic> = 0.017) than the RVP group. Four patients in the RVP group died\u2014three deaths were due to progressive heart failure and one was due to non-cardiac reasons. One death in the LBBP group was due to the non-cardiac reasons.<\/jats:p><jats:p><jats:bold>Conclusions:<\/jats:bold> CSP achieved shorter paced QRS duration and better cardiac structure and function in post-TAVR patients than RVP. LBBP had a higher implant success rate and better pacing parameters than HBP.<\/jats:p>","DOI":"10.3389\/fcvm.2021.772548","type":"journal-article","created":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T16:25:11Z","timestamp":1638375911000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":28,"title":["Conduction System Pacing for Post Transcatheter Aortic Valve Replacement Patients: Comparison With Right Ventricular Pacing"],"prefix":"10.3389","volume":"8","author":[{"given":"Hong-Xia","family":"Niu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xi","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min","family":"Gu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuhua","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chi","family":"Cai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minsi","family":"Cai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shu","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Hua","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2021,11,30]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"2932","DOI":"10.1161\/01.CIR.0000072769.17295.B1","article-title":"Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline qrs duration in a clinical trial of pacemaker therapy for sinus node dysfunction","volume":"107","author":"Sweeney","year":"2003","journal-title":"Circulation."},{"key":"B2","doi-asserted-by":"publisher","first-page":"2319","DOI":"10.1016\/j.jacc.2018.02.048","article-title":"Clinical outcomes of his bundle pacing compared to right ventricular pacing","volume":"71","author":"Abdelrahman","year":"2018","journal-title":"J Am Coll Cardiol."},{"key":"B3","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1016\/j.jacep.2020.02.010","article-title":"His-purkinje conduction system pacing following transcatheter aortic valve replacement: feasibility and safety","volume":"6","author":"Vijayaraman","year":"2020","journal-title":"JACC Clin Electrophysiol."},{"key":"B4","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.hrthm.2016.09.016","article-title":"Permanent his-bundle pacing in patients with prosthetic cardiac valves","volume":"14","author":"Sharma","year":"2017","journal-title":"Hear Rhythm."},{"key":"B5","doi-asserted-by":"publisher","first-page":"3039","DOI":"10.1016\/j.jacc.2019.10.039","article-title":"Left bundle branch pacing: JACC review topic of the week","volume":"74","author":"Zhang","year":"2019","journal-title":"J Am Coll Cardiol."},{"key":"B6","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1111\/pace.14132","article-title":"Rapid reversal of heart failure by correcting left bundle branch block induced by transcatheter aortic valve replacement","volume":"44","author":"Zhang","year":"2021","journal-title":"Pacing Clin Electrophysiol."},{"key":"B7","doi-asserted-by":"publisher","first-page":"1110","DOI":"10.1002\/clc.23413","article-title":"Feasibility and stability of left bundle branch pacing in patients after prosthetic valve implantation","volume":"43","author":"Guo","year":"2020","journal-title":"Clin Cardiol."},{"key":"B8","doi-asserted-by":"publisher","first-page":"e008370","DOI":"10.1161\/CIRCEP.120.008370","article-title":"Permanent his bundle pacing implantation facilitated by visualization of the tricuspid valve annulus","volume":"13","author":"Gu","year":"2020","journal-title":"Circ Arrhythm Electrophysiol."},{"key":"B9","doi-asserted-by":"publisher","first-page":"1318","DOI":"10.1016\/j.hrthm.2021.04.015","article-title":"Contrast-enhanced image-guided lead deployment for left bundle branch pacing","volume":"18","author":"Liu","year":"2021","journal-title":"Hear Rhythm"},{"key":"B10","doi-asserted-by":"publisher","first-page":"2164","DOI":"10.1111\/jce.14140","article-title":"Visualization of tricuspid valve annulus for implantation of his bundle pacing in patients with symptomatic bradycardia","volume":"30","author":"Gu","year":"2019","journal-title":"J Cardiovasc Electrophysiol."},{"key":"B11","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1016\/j.iccl.2019.06.003","article-title":"Conduction system abnormalities after transcatheter aortic valve replacement: mechanism, prediction, and management","volume":"8","author":"Judson","year":"2019","journal-title":"Interv Cardiol Clin."},{"key":"B12","doi-asserted-by":"publisher","first-page":"2607","DOI":"10.1016\/j.jacc.2019.08.1064","article-title":"Incidence and risk factors for permanent pacemaker implantation following mitral or aortic valve surgery","volume":"74","author":"Moskowitz","year":"2019","journal-title":"J Am Coll Cardiol."},{"key":"B13","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1016\/j.hrthm.2016.11.029","article-title":"Long-term requirement for pacemaker implantation after cardiac valve replacement surgery","volume":"14","author":"Leyva","year":"2017","journal-title":"Hear Rhythm."},{"key":"B14","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1007\/s00392-017-1158-2","article-title":"Pacemaker implantation after TAVI: predictors of AV block persistence","volume":"107","author":"Gaede","year":"2018","journal-title":"Clin Res Cardiol."},{"key":"B15","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.hrthm.2020.10.013","article-title":"Effect of pacemaker implantation after transcatheter aortic valve replacement on long- and mid-term mortality","volume":"18","author":"Hochstadt","year":"2021","journal-title":"Hear Rhythm."},{"key":"B16","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2021.06.1175","article-title":"Outcomes associated with pacemaker implantation following transcatheter aortic valve replacement: a nationwide cohort study","volume-title":"Hear Rhythm.","author":"Clementy","year":"2021"},{"key":"B17","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1016\/j.hrthm.2017.10.039","article-title":"Permanent his bundle pacing: recommendations from a multicenter his bundle pacing collaborative working group for standardization of definitions, implant measurements, and follow-up","volume":"15","author":"Vijayaraman","year":"2018","journal-title":"Hear Rhythm."},{"key":"B18","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1016\/j.jacc.2018.06.017","article-title":"His bundle pacing","volume":"72","author":"Vijayaraman","year":"2018","journal-title":"J Am Coll Cardiol."},{"key":"B19","doi-asserted-by":"publisher","first-page":"763","DOI":"10.1093\/europace\/euy281","article-title":"Pacing parameters and success rates of permanent his-bundle pacing in patients with narrow QRS: a single-centre experience","volume":"21","author":"Su","year":"2019","journal-title":"Eurpace."},{"key":"B20","doi-asserted-by":"publisher","first-page":"1291","DOI":"10.1016\/j.jacep.2020.05.008","article-title":"Comparison of left bundle branch and his bundle pacing in bradycardia patients","volume":"6","author":"Hua","year":"2020","journal-title":"JACC Clin Electrophysiol."},{"key":"B21","doi-asserted-by":"publisher","first-page":"e04617","DOI":"10.1002\/ccr3.4617","article-title":"Ventricular pacemaker lead in the left hemithorax: mechanisms and evidence-based management of a late-onset hazardous complication","volume":"9","author":"Marazzato","year":"2021","journal-title":"Clin Case Rep."}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2021.772548\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T16:25:14Z","timestamp":1638375914000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2021.772548\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11,30]]},"references-count":21,"alternative-id":["10.3389\/fcvm.2021.772548"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2021.772548","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,11,30]]},"article-number":"772548"}}