{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T15:49:30Z","timestamp":1753890570946,"version":"3.41.2"},"reference-count":26,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,1,31]],"date-time":"2022-01-31T00:00:00Z","timestamp":1643587200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>There is no evidence of hemodynamic performance during exercise in patients with aortic stenosis (AS) after transcatheter aortic valve implantation (TAVI). This study aimed to investigate the changes in kinematic hemodynamics during exercise and determine the impact of prosthesis-patient mismatch (PPM) on the hemodynamics of transcatheter heart valves using exercise stress echocardiography (ESE) in AS patients after TAVI.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods and Results<\/jats:title><jats:p>This study enrolled 77 consecutive patients (mean age 82 \u00b1 5 years, 50.6% male) who underwent ESE 3\u20136 months after TAVI with a balloon-expandable valve. The effective orifice area index at rest was significantly correlated with the mean pressure gradient (PG) during exercise (<jats:italic>p<\/jats:italic> &amp;lt;0.001). The patients were divided into two groups according to the presence of PPM (PPM and non-PPM groups). During exercise, the patients with PPM had a higher left ventricular ejection fraction (74.6 \u00b1 6.1% vs. 69.7 \u00b1 9.6%, <jats:italic>p<\/jats:italic> = 0.048), a lower stroke volume index (47.2 \u00b1 14.0 ml\/m<jats:sup>2<\/jats:sup> vs. 55.6 \u00b1 14.5 ml\/m<jats:sup>2<\/jats:sup>, <jats:italic>p<\/jats:italic> = 0.037), a significantly higher mean transvalvular PG (21.9 \u00b1 9.1 mmHg vs. 12.2 \u00b1 4.9 mmHg, <jats:italic>p<\/jats:italic> = 0.01) and an increased mean PG from rest to exercise (5.7 \u00b1 3.5 mmHg vs. 2.3 \u00b1 2.8 mmHg, <jats:italic>p<\/jats:italic> &amp;lt;0.001) compared with patients without PPM. Patients with PPM had a higher pulmonary artery systolic pressure (SPAP) during exercise (57.3 \u00b1 13.8 mmHg vs. 49.7 \u00b1 10.9 mmHg, <jats:italic>p<\/jats:italic> = 0.021) and a higher incidence of exercise-induced pulmonary hypertension (43.8 vs. 15.0%, <jats:italic>p<\/jats:italic> = 0.037) than patients without PPM. PPM was strongly associated with exercise-induced pulmonary hypertension (hazard ratio: 3.570, <jats:italic>p<\/jats:italic> = 0.013).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>AS patients with PPM after TAVI showed a disproportionate increase in the transvalvular PG and SPAP during exercise, and PPM was associated with exercise-induced pulmonary hypertension.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fcvm.2021.799285","type":"journal-article","created":{"date-parts":[[2022,1,31]],"date-time":"2022-01-31T06:57:28Z","timestamp":1643612248000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve"],"prefix":"10.3389","volume":"8","author":[{"given":"Haruka","family":"Kameshima","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masaki","family":"Izumo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomomi","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Ohara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yukio","family":"Sato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mika","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shingo","family":"Kuwata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuaki","family":"Okuyama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryo","family":"Kamijima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Manabu","family":"Takai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seisyou","family":"Kou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuhiro","family":"Tanabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomoo","family":"Harada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshihiro J.","family":"Akashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2022,1,31]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1695","DOI":"10.1056\/NEJMoa1814052","article-title":"Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients","volume":"380","author":"Mack","year":"2019","journal-title":"N Engl J Med."},{"key":"B2","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1161\/01.CIR.58.1.20","article-title":"The problem of valve prosthesis-patient mismatch","volume":"58","author":"Rahimtoola","year":"1978","journal-title":"Circulation."},{"key":"B3","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1161\/01.CIR.0000085167.67105.32","article-title":"Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement","volume":"108","author":"Blais","year":"2003","journal-title":"Circulation."},{"key":"B4","doi-asserted-by":"publisher","first-page":"1518","DOI":"10.1093\/eurheartj\/ehs003","article-title":"The impact of prosthesis\u2013patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years","volume":"33","author":"Head","year":"2012","journal-title":"European heart journal."},{"key":"B5","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1016\/j.jcmg.2015.10.026","article-title":"Predictors and outcomes of prosthesis-patient mismatch after aortic valve replacement","volume":"9","author":"Dayan","year":"2016","journal-title":"JACC: Cardiovasc Imaging."},{"key":"B6","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.jacc.2014.06.1195","article-title":"Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort-A analysis","volume":"64","author":"Pibarot","year":"2014","journal-title":"J Am Coll Cardiol."},{"key":"B7","doi-asserted-by":"publisher","first-page":"2123","DOI":"10.1161\/CIRCULATIONAHA.109.901272","article-title":"Prosthesis-patient mismatch predicts structural valve degeneration in bioprosthetic heart valves","volume":"121","author":"Flameng","year":"2010","journal-title":"Circulation."},{"key":"B8","doi-asserted-by":"publisher","first-page":"2701","DOI":"10.1016\/j.jacc.2018.09.001","article-title":"Prosthesis\u2013patient mismatch in patients undergoing transcatheter aortic valve replacement: from the STS\/ACC TVT registry","volume":"72","author":"Herrmann","year":"2018","journal-title":"J Am Coll Cardiol."},{"key":"B9","doi-asserted-by":"publisher","first-page":"1648","DOI":"10.4244\/EIJ-D-18-00827","article-title":"Prosthesis-patient mismatch after transcatheter aortic valve implantation: prevalence and prognostic impact with respect to baseline left ventricular function","volume":"14","author":"Schofer","year":"2019","journal-title":"EuroIntervention."},{"key":"B10","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1093\/ehjci\/jev014","article-title":"Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging","volume":"16","author":"Lang","year":"2015","journal-title":"Eur Heart J Cardiovasc Imaging."},{"key":"B11","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1093\/ehjci\/jew025","article-title":"Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging","volume":"17","author":"Lancellotti","year":"2016","journal-title":"Eur Heart J Cardiovasc Imaging."},{"key":"B12","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1016\/j.echo.2017.02.009","article-title":"Recommendations on the echocardiographic assessment of aortic valve stenosis: a focused update from the European Association of Cardiovascular Imaging and the American Society of Echocardiography","volume":"30","author":"Baumgartner","year":"2017","journal-title":"J Am Soc Echocardiogr."},{"key":"B13","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1016\/j.jcmg.2015.01.008","article-title":"Assessment of paravalvular regurgitation following TAVR: a proposal of unifying grading scheme","volume":"8","author":"Pibarot","year":"2015","journal-title":"JACC Cardiovasc Imaging."},{"key":"B14","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1016\/j.jcct.2012.11.002","article-title":"SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)\/transcatheter aortic valve replacement (TAVR)","volume":"6","author":"Achenbach","year":"2012","journal-title":"J Cardiovasc Comp Tomogr."},{"key":"B15","doi-asserted-by":"publisher","first-page":"1609","DOI":"10.1016\/S0735-1097(99)00360-5","article-title":"Hemodynamic and physical performance during maximal exercise in patients with an aortic bioprosthetic valve: comparison of stentless versus stented bioprostheses","volume":"34","author":"Pibarot","year":"1999","journal-title":"J Am Coll Cardiol."},{"key":"B16","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1016\/S0002-9149(98)00910-2","article-title":"Usefulness of the indexed effective orifice area at rest in predicting an increase in gradient during maximum exercise in patients with a bioprosthesis in the aortic valve position","volume":"83","author":"Pibarot","year":"1999","journal-title":"Am J Cardiol."},{"key":"B17","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1136\/hrt.2007.116673","article-title":"Impact of patient-prosthesis mismatch on exercise capacity in patients after bioprosthetic aortic valve replacement","volume":"94","author":"Bleiziffer","year":"2008","journal-title":"Heart."},{"key":"B18","doi-asserted-by":"publisher","first-page":"e002358","DOI":"10.1161\/CIRCINTERVENTIONS.114.002358","article-title":"Effect of pulmonary hypertension hemodynamic presentation on clinical outcomes in patients with severe symptomatic aortic valve stenosis undergoing transcatheter aortic valve implantation: insights from the new proposed pulmonary hypertension classification","volume":"8","author":"O'Sullivan","year":"2015","journal-title":"Circ Cardiovasc Interventions."},{"key":"B19","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1161\/CIRCULATIONAHA.111.085761","article-title":"Pulmonary hypertension due to left heart disease","volume":"126","author":"Guazzi","year":"2012","journal-title":"Circulation."},{"key":"B20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.echo.2012.10.009","article-title":"Echocardiography in pulmonary arterial hypertension: from diagnosis to prognosis","volume":"26","author":"Bossone","year":"2013","journal-title":"J Am Soc Echocardiogr."},{"key":"B21","doi-asserted-by":"publisher","first-page":"1226","DOI":"10.1016\/S0735-1097(96)00315-4","article-title":"Noninvasive Doppler echocardiographic evaluation of left ventricular filling pressures in patients with cardiomyopathies: a simultaneous Doppler echocardiographic and cardiac catheterization study","volume":"28","author":"Nishimura","year":"1996","journal-title":"J Am Coll Cardiol."},{"key":"B22","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1161\/01.CIR.99.2.254","article-title":"Doppler estimation of left ventricular filling pressures in patients with hypertrophic cardiomyopathy","volume":"99","author":"Nagueh","year":"1999","journal-title":"Circulation."},{"key":"B23","doi-asserted-by":"publisher","first-page":"2702","DOI":"10.1161\/CIRCULATIONAHA.107.698985","article-title":"Evaluation of left ventricular filling pressures by Doppler echocardiography in patients with hypertrophic cardiomyopathy: correlation with direct left atrial pressure measurement at cardiac catheterization","volume":"116","author":"Geske","year":"2007","journal-title":"Circulation."},{"key":"B24","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1053\/euje.2001.0137","article-title":"Mitral inflow and mitral annular motion velocities in patients with mitral annular calcification: evaluation by pulsed Doppler echocardiography and pulsed Doppler tissue imaging","volume":"3","author":"Soeki","year":"2002","journal-title":"Eur J Echocardiogr."},{"key":"B25","doi-asserted-by":"publisher","first-page":"1411","DOI":"10.1016\/j.jcmg.2016.10.017","article-title":"Doppler echocardiography for the estimation of LV filling pressure in patients with mitral annular calcification","volume":"10","author":"Abudiab","year":"2017","journal-title":"JACC Cardiovasc Imaging."},{"key":"B26","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.jcmg.2018.04.010","article-title":"Comprehensive echocardiographic assessment of normal transcatheter valve function","volume":"12","author":"Hahn","year":"2019","journal-title":"JACC Cardiovasc Imaging."}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2021.799285\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,31]],"date-time":"2022-01-31T06:57:31Z","timestamp":1643612251000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2021.799285\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,31]]},"references-count":26,"alternative-id":["10.3389\/fcvm.2021.799285"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2021.799285","relation":{},"ISSN":["2297-055X"],"issn-type":[{"type":"electronic","value":"2297-055X"}],"subject":[],"published":{"date-parts":[[2022,1,31]]},"article-number":"799285"}}