{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T01:29:35Z","timestamp":1783128575597,"version":"3.54.6"},"reference-count":12,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,9,28]],"date-time":"2022-09-28T00:00:00Z","timestamp":1664323200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>Juxtarenal abdominal aortic aneurysms (JRAAAs) are challenging to cure by traditional endovascular aortic repair (EVAR). Due to the inherent disadvantages of the customized fenestrated and\/or branched aortic endografts (such as delayed cycles with a risk of aneurysm rupture, unavailable in emergency or confine operations), several off-the-shelf devices have been developed for the treatment of JRAAA. However, these devices being used in clinical trials have been proven to have a non-negligible risk of reintervention and inadequate anatomic applicability. We have developed a new off-the-shelf aortic endograft system (WeFlow-JAAA) with a mixed design of inner branches and modified fenestrations. The purpose of this cohort study is to assess the safety and effectiveness of the innovative aortic endograft system.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods and analysis<\/jats:title><jats:p>This is a prospective, multicenter, single-armed clinical trial cohort study. The enrolment will take place in 29 centers in China, and 106 adult patients with JRAAA will be enrolled in total. Clinical information and CT angiography (CTA) images will be collected and recorded. Patients will be followed up for 5 years. The primary safety endpoint is the rate of no major adverse event within 30 days after index EVAR. The primary efficacy endpoint is the rate of immediate technical success and no JRAAA-related reintervention within 12 months after the procedure.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fcvm.2022.1013834","type":"journal-article","created":{"date-parts":[[2022,9,28]],"date-time":"2022-09-28T05:21:45Z","timestamp":1664342505000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":6,"title":["A prospective, multicenter, single-arm clinical trial cohort to evaluate the safety and effectiveness of a novel stent graft system (WeFlow-JAAA) for the treatment of juxtarenal abdominal aortic aneurysm: A study protocol"],"prefix":"10.3389","volume":"9","author":[{"given":"Jiang-Ping","family":"Gao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong-Peng","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Jia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiang","family":"Xiong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao-Hui","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li-Jun","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min-Hong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong-Le","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,9,28]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1016\/j.ejvs.2018.09.020","article-title":"Editor\u2019s choice \u2013 European society for vascular surgery (ESVS) 2019 clinical practice guidelines on the management of abdominal aorto-iliac artery aneurysms.","volume":"57","author":"Wanhainen","year":"2019","journal-title":"Eur J Vasc Endovasc Surg."},{"key":"B2","doi-asserted-by":"publisher","first-page":"641","DOI":"10.6061\/clinics\/2014(09)11","article-title":"Open and endovascular repair of juxtarenal abdominal aortic aneurysms: a systematic review.","volume":"69","author":"Belczak","year":"2014","journal-title":"Clinics."},{"key":"B3","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1002\/bjs5.50178","article-title":"Meta-analysis of fenestrated endovascular aneurysm repair versus open surgical repair of juxtarenal abdominal aortic aneurysms over the last 10 years.","volume":"3","author":"Jones","year":"2019","journal-title":"BJS Open."},{"key":"B4","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.jvs.2019.08.273","article-title":"The risk of aneurysm rupture and target visceral vessel occlusion during the lead period of custom-made fenestrated\/branched endograft.","volume":"72","author":"Gallitto","year":"2020","journal-title":"J Vasc Surg."},{"key":"B5","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.ejvs.2020.03.003","article-title":"Aneurysm rupture and mortality during the waiting time for a customised fenestrated\/branched stent graft in complex endovascular aortic repair.","volume":"60","author":"Katsargyris","year":"2020","journal-title":"Eur J Vasc Endovasc Surg."},{"key":"B6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jvs.2012.12.065","article-title":"Prospective, multicenter experience with the ventana fenestrated system for juxtarenal and pararenal aortic aneurysm endovascular repair.","volume":"58","author":"Qui\u00f1ones-Baldrich","year":"2013","journal-title":"J Vasc Surg."},{"key":"B7","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1016\/j.ejvs.2020.12.012","article-title":"Five year results of off the shelf fenestrated endografts for elective and emergency repair of juxtarenal abdominal aortic aneurysm.","volume":"61","author":"Sveinsson","year":"2021","journal-title":"Eur J Vasc Endovasc Surg."},{"key":"B8","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1177\/1526602815611887","article-title":"Systematic review of off-the-shelf or physician-modified fenestrated and branched endografts.","volume":"23","author":"Georgiadis","year":"2016","journal-title":"J Endovasc Ther."},{"key":"B9","author":"de Niet","year":"2020","journal-title":"Endovascular Approaches To Complex Aortic Aneurysms."},{"key":"B10","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1016\/j.jvs.2014.03.258","article-title":"\u201dOff-the-shelf\u201d devices for complex aortic aneurysm repair.","volume":"60","author":"Farber","year":"2014","journal-title":"J Vasc Surg."},{"key":"B11","doi-asserted-by":"publisher","first-page":"1417","DOI":"10.1016\/j.jvs.2014.12.061","article-title":"The compatibility of p-branch \u201coff-the-shelf\u201d fenestrated endovascular graft in Asian patients with juxtarenal aortic aneurysm.","volume":"61","author":"Ou","year":"2015","journal-title":"J Vasc Surg."},{"key":"B12","doi-asserted-by":"publisher","first-page":".1420","DOI":"10.1016\/j.jvs.2014.08.061","article-title":"Results of the United States multicenter prospective study evaluating the Zenith fenestrated endovascular graft for treatment of juxtarenal abdominal aortic aneurysms.","volume":"60","author":"Oderich","year":"2014","journal-title":"J Vasc Surg."}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2022.1013834\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,28]],"date-time":"2022-09-28T05:21:49Z","timestamp":1664342509000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2022.1013834\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,28]]},"references-count":12,"alternative-id":["10.3389\/fcvm.2022.1013834"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2022.1013834","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,28]]},"article-number":"1013834"}}