{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T13:57:35Z","timestamp":1778162255240,"version":"3.51.4"},"reference-count":20,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,10,4]],"date-time":"2022-10-04T00:00:00Z","timestamp":1664841600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>The use of cardiovascular implantable electronic device (CIED) is steadily increasing, and complications include venous occlusion and fractured leads. Transvenous lead extraction (TLE) can facilitate the re-implantation of new leads.<\/jats:p><\/jats:sec><jats:sec><jats:title>Aims<\/jats:title><jats:p>This study aims to explore predictors and complications of non-infectious TLE.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This study involves a retrospective analysis and comparison of characteristics, complications, and outcomes of patients with and without occluded veins (OVs) undergoing TLE at our center.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>In total, eighty-eight patients underwent TLE for non-infectious reasons. Indications for TLE were lead malfunction (62; 70.5%) and need for CIED upgrade (22; 25%). Fourteen patients referred due to lead malfunction had an OV observed during venography. The OV group (36 patients) were significantly older (65.7 \u00b1 14.1 vs. 53.8 \u00b1 15.9, <jats:italic>p<\/jats:italic> = 0.001) and had more comorbidities. Ejection fraction (EF) was significantly lower for the OV group (27.5 vs. 57.5%, <jats:italic>p<\/jats:italic> = 0.001) and had a longer lead dwelling time (3,226 \u00b1 2,324 vs. 2,191 \u00b1 1,355 days, <jats:italic>p<\/jats:italic> = 0.012). Major complications were exclusive for the OV group (5.5% vs. none, <jats:italic>p<\/jats:italic> = 0.17), and most minor complications occurred in the OV group as well (33.3 vs. 4.1%, <jats:italic>p<\/jats:italic> &amp;lt; 0.001). Laser sheath and mechanical tools for TLE were frequently used for OV as compared to the non-occluded group (94.4 vs. 73.5%, respectively, <jats:italic>p<\/jats:italic> = 0.012). Procedure success was higher in the non-occluded group compared to the OV group (98 vs. 83.3%, respectively, <jats:italic>p<\/jats:italic> = 0.047). Despite these results, periprocedural mortality was similar between groups.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Among the TLE for non-infectious reasons, vein occlusion appears as a major predictor of complex TLE tool use, complications, and procedural success. Venography should be considered prior to non-infectious TLE to identify high-risk patients.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fcvm.2022.1016657","type":"journal-article","created":{"date-parts":[[2022,10,12]],"date-time":"2022-10-12T16:02:51Z","timestamp":1665590571000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["Occluded vein as a predictor for complications in non-infectious transvenous lead extraction"],"prefix":"10.3389","volume":"9","author":[{"given":"Anat","family":"Milman","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eran","family":"Leshem","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eias","family":"Massalha","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Karen","family":"Jia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amit","family":"Meitus","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saar","family":"Kariv","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuval","family":"Shafir","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Glikson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Luria","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Avi","family":"Sabbag","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roy","family":"Beinart","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eyal","family":"Nof","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2022,10,4]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"e503","DOI":"10.1016\/j.hrthm.2017.09.001","article-title":"2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction","volume":"14","author":"Kusumoto","year":"2017","journal-title":"Heart Rhythm."},{"key":"B2","doi-asserted-by":"publisher","first-page":"e002418","DOI":"10.1161\/JAHA.115.002418","article-title":"Transvenous implantable cardioverter-defibrillator (ICD) lead performance: a meta-analysis of observational studies","volume":"4","author":"Provid\u00eancia","year":"2015","journal-title":"J Am Heart Assoc."},{"key":"B3","doi-asserted-by":"publisher","first-page":"2391","DOI":"10.1161\/CIRCULATIONAHA.106.622076","article-title":"Transvenous pacing leads and systemic thromboemboli in patients with intracardiac shunts: a multicenter study","volume":"113","author":"Khairy","year":"2006","journal-title":"Circulation."},{"key":"B4","doi-asserted-by":"publisher","first-page":"1350","DOI":"10.1093\/europace\/eut424","article-title":"Twenty-year experience of transvenous lead extraction at a single centre","volume":"16","author":"Gomes","year":"2014","journal-title":"Europace."},{"key":"B5","doi-asserted-by":"publisher","first-page":"2461","DOI":"10.1161\/CIRCULATIONAHA.107.698597","article-title":"Transvenous implantable cardioverter-defibrillator leads: the weakest link","volume":"115","author":"Maisel","year":"2007","journal-title":"Circulation."},{"key":"B6","doi-asserted-by":"publisher","first-page":"2995","DOI":"10.1093\/eurheartj\/ehx080","article-title":"The European lead extraction ConTRolled (ELECTRa) study: a European heart rhythm association (EHRA) registry of transvenous lead extraction outcomes","volume":"38","author":"Bongiorni","year":"2017","journal-title":"Eur Heart J."},{"key":"B7","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1016\/j.jacc.2009.08.070","article-title":"Lead extraction in the contemporary setting: the LExICon study. An observational retrospective study of consecutive laser lead extractions","volume":"55","author":"Wazni","year":"2010","journal-title":"J Am Coll Cardiol."},{"key":"B8","doi-asserted-by":"publisher","first-page":"e0215589","DOI":"10.1371\/journal.pone.0215589","article-title":"Transvenous lead extraction with laser reduces need for femoral approach during the procedure","volume":"14","author":"Younis","year":"2019","journal-title":"PLoS ONE."},{"key":"B9","doi-asserted-by":"publisher","first-page":"1155","DOI":"10.1111\/jce.14436","article-title":"Predictors of short-term mortality in patients undergoing a successful uncomplicated extraction procedure","volume":"31","author":"Milman","year":"2020","journal-title":"J Cardiovasc Electrophysiol."},{"key":"B10","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.1093\/europace\/euy050","article-title":"2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, data collection requirements for clinical scientific studies registries: endorsed by APHRS\/HRS\/LAHRS","volume":"20","author":"Bongiorni","year":"2018","journal-title":"Europace."},{"key":"B11","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1016\/j.hrthm.2021.10.019","article-title":"Predictors of perforation during lead extraction; results of the Canadian Lead ExtrAction risk (CLEAR) study","volume":"19","author":"Bashir","year":"2021","journal-title":"Heart Rhythm."},{"key":"B12","doi-asserted-by":"publisher","first-page":"1566","DOI":"10.1016\/j.hrthm.2021.05.007","article-title":"2021. Long-term survival following transvenous lead extraction: importance of indication and comorbidities","volume":"18","author":"Mehta","year":"2021","journal-title":"Heart Rhythm"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1177","DOI":"10.1016\/j.hrthm.2015.02.005","article-title":"Extraction of superfluous device leads: a comparison with removal of infected leads","volume":"12","author":"Huang","year":"2015","journal-title":"Heart Rhythm."},{"key":"B14","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1111\/jce.14841","article-title":"Transvenous extraction of permanent pacemaker and defibrillator leads: reduced procedural complexity and higher procedural success rates in patients with infective versus noninfective indications","volume":"32","author":"Archontakis","year":"2021","journal-title":"J Cardiovasc Electrophysiol."},{"key":"B15","doi-asserted-by":"publisher","first-page":"1029","DOI":"10.1055\/s-0035-1553351","article-title":"Obstruction in asymptomatic patients undergoing first implantation or revision of a cardiac pacemaker or implantable cardioverter-defibrillator: a retrospective single center analysis","volume":"187","author":"Pieper","year":"2015","journal-title":"Rofo."},{"key":"B16","doi-asserted-by":"publisher","first-page":"1258","DOI":"10.1046\/j.1540-8167.2004.04081.x","article-title":"Incidence and risk factors of early venous thrombosis associated with permanent pacemaker leads","volume":"15","author":"van Rooden","year":"2004","journal-title":"J Cardiovasc Electrophysiol."},{"key":"B17","doi-asserted-by":"publisher","first-page":"1220","DOI":"10.1093\/europace\/euv391","article-title":"Prevalence and predictor factors of severe venous obstruction after cardiovascular electronic device implantation","volume":"18","author":"Santini","year":"2016","journal-title":"Europace."},{"key":"B18","doi-asserted-by":"publisher","first-page":"1649","DOI":"10.1046\/j.1460-9592.2003.t01-1-00247.x","article-title":"Venous occlusion of the access vein in patients referred for lead extraction: influence of patient and lead characteristics","volume":"26","author":"Bracke","year":"2003","journal-title":"Pacing Clin Electrophysiol."},{"key":"B19","doi-asserted-by":"publisher","first-page":"1795","DOI":"10.1093\/europace\/euu124","article-title":"Prevalence of venous occlusion in patients referred for lead extraction: implications for tool selection","volume":"16","author":"Li","year":"2014","journal-title":"Europace."},{"key":"B20","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1080\/00015385.2017.1281545","article-title":"Venous stenosis and occlusion in the presence of endocardial leads in patients referred for transvenous lead extraction","volume":"72","author":"Boczar","year":"2017","journal-title":"Acta Cardiol."}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2022.1016657\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,12]],"date-time":"2022-10-12T16:02:52Z","timestamp":1665590572000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2022.1016657\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,4]]},"references-count":20,"alternative-id":["10.3389\/fcvm.2022.1016657"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2022.1016657","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,4]]},"article-number":"1016657"}}