{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T19:10:25Z","timestamp":1777662625119,"version":"3.51.4"},"reference-count":14,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,11,9]],"date-time":"2022-11-09T00:00:00Z","timestamp":1667952000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Left bundle branch (LBB) pacing (LBBP) has recently emerged as a physiological pacing mode. Current of injury (COI) can be used as the basis for electrode fixation position and detection of perforation. However, because the intermittent pacing method cannot monitor the changes in COI in real time, it cannot obtain information about the entire COI change process during implantation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Case summary<\/jats:title><jats:p>Left bundle branch pacing was achieved for treatment of atrioventricular block in a 76-year-old female. Uninterrupted electrocardiogram and electrogram were recorded on an electrophysiology system. In contrast to the interrupted pacing method, this continuous pacing and recording technique enables real-time monitoring of the change in ventricular COI and the paced QRS complex as the lead advances into the interventricular septum. During the entire screw-in process, the COI amplitude increased and then decreased gradually after reaching the peak, followed by a small but significant, rather than dramatic, decrease.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>This case report aims to demonstrate the clinical significance of changes in COI and QRS morphology for LBBP using real-time electrocardiographic monitoring and filtered and unfiltered electrograms when the lead is deployed using a continuous pacing technique. The technique could be used to confirm LBB capture and avoid perforation.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fcvm.2022.1025620","type":"journal-article","created":{"date-parts":[[2022,11,9]],"date-time":"2022-11-09T05:04:25Z","timestamp":1667970265000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":6,"title":["Case report: Left bundle branch pacing guided by real-time monitoring of current of injury and electrocardiography"],"prefix":"10.3389","volume":"9","author":[{"given":"Jiabo","family":"Shen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Longfu","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hao","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hengdong","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinyan","family":"Zhong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lifang","family":"Pan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2022,11,9]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1736.e1","DOI":"10.1016\/j.cjca.2017.09.013","article-title":"A novel pacing strategy with low and stable output: pacing the left bundle branch immediately beyond the conduction block.","volume":"33","author":"Huang","year":"2017","journal-title":"Can J Cardiol."},{"key":"B2","doi-asserted-by":"publisher","first-page":"1791","DOI":"10.1016\/j.hrthm.2019.06.016","article-title":"A beginner\u2019s guide to permanent left bundle branch pacing.","volume":"16","author":"Huang","year":"2019","journal-title":"Heart Rhythm."},{"key":"B3","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1016\/j.hrthm.2022.01.018","article-title":"Electrophysiological characteristics of septal perforation during left bundle branch pacing.","volume":"19","author":"Ponnusamy","year":"2022","journal-title":"Heart Rhythm."},{"key":"B4","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1016\/j.hrthm.2022.04.027","article-title":"Current of injury is an indicator of lead depth and performance during left bundle branch pacing lead implantation.","volume":"19","author":"Shali","year":"2022","journal-title":"Heart Rhythm."},{"key":"B5","doi-asserted-by":"publisher","first-page":"1315","DOI":"10.1016\/j.cjca.2022.03.003","article-title":"Left bundle branch pacing guided by continuous pacing technique that can monitor electrocardiograms and electrograms in real time: a technical report.","volume":"38","author":"Shen","year":"2022","journal-title":"Can J Cardiol."},{"key":"B6","doi-asserted-by":"publisher","DOI":"10.1016\/j.cjca.2022.09.008","article-title":"A continuous pacing and recording technique for differentiating left bundle branch pacing from left ventricular septal pacing.","author":"Shen","year":"2022","journal-title":"Can J Cardiol."},{"key":"B7","doi-asserted-by":"publisher","first-page":"664","DOI":"10.33963\/KP.a2022.0094","article-title":"Recording an isoelectric interval as an endpoint of left bundle branch pacing with continuous paced intracardiac electrogram monitoring.","volume":"80","author":"Wu","year":"2022","journal-title":"Kardiol Pol."},{"key":"B8","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-022-01203-2","article-title":"Premature beat of selective left bundle branch: a novel marker for reaching and capturing the left bundle branch.","author":"Shen","year":"2022","journal-title":"J Interv Card Electrophysiol."},{"key":"B9","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2022.06.022","article-title":"Electrophysiological characteristics and possible mechanism of bipolar pacing in left bundle branch pacing.","author":"Wu","year":"2022","journal-title":"Heart Rhythm."},{"key":"B10","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1016\/j.jacc.2004.10.045","article-title":"Current of injury predicts adequate active lead fixation in permanent pacemaker\/defibrillation leads.","volume":"45","author":"Saxonhouse","year":"2005","journal-title":"J Am Coll Cardiol."},{"key":"B11","doi-asserted-by":"publisher","first-page":"1438","DOI":"10.1111\/j.1540-8159.2007.00889.x","article-title":"Current of injury predicts acute performance of catheter-delivered active fixation pacing leads.","volume":"30","author":"Redfearn","year":"2007","journal-title":"Pacing Clin Electrophysiol."},{"key":"B12","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1016\/j.ijcard.2018.01.005","article-title":"Could persistency of current of injury forecast successful active-fixation pacing lead implantation?","volume":"258","author":"Shali","year":"2018","journal-title":"Int J Cardiol."},{"key":"B13","doi-asserted-by":"publisher","first-page":"834","DOI":"10.1111\/jce.14377","article-title":"Electrophysiological characteristics and clinical values of left bundle branch current of injury in left bundle branch pacing.","volume":"31","author":"Su","year":"2020","journal-title":"J Cardiovasc Electrophysiol."},{"key":"B14","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1093\/europace\/euab164","article-title":"The V6-V1 interpeak interval: a novel criterion for the diagnosis of left bundle branch capture.","volume":"24","author":"Jastrz\u0119bski","year":"2022","journal-title":"Europace."}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2022.1025620\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,9]],"date-time":"2022-11-09T05:04:30Z","timestamp":1667970270000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2022.1025620\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,9]]},"references-count":14,"alternative-id":["10.3389\/fcvm.2022.1025620"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2022.1025620","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,9]]},"article-number":"1025620"}}