{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T04:11:48Z","timestamp":1787026308251,"version":"build-2736575974"},"reference-count":35,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,7,22]],"date-time":"2022-07-22T00:00:00Z","timestamp":1658448000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec>\n                    <jats:title>Aims<\/jats:title>\n                    <jats:p>\n                      This study aimed to assess the diagnostic performances of dual-energy computed tomography (CT)-derived iodine concentration and effective atomic number (Z\n                      <jats:sub>\n                        <jats:italic>eff<\/jats:italic>\n                      <\/jats:sub>\n                      ) in early-phase cardiac CT in detecting left atrial appendage (LAA) thrombus and differentiating thrombus from spontaneous echo contrast (SEC) in patients with atrial fibrillation using transesophageal echocardiography (TEE) as the reference standard.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and results<\/jats:title>\n                    <jats:p>\n                      A total of 389 patients with atrial fibrillation were prospectively recruited. All patients underwent a single-phase cardiac dual-energy CT scan using a third-generation dual-source CT. The iodine concentration, Z\n                      <jats:sub>\n                        <jats:italic>eff<\/jats:italic>\n                      <\/jats:sub>\n                      , and conventional Hounsfield units (HU) in the LAA were measured and normalized to the ascending aorta (AA) of the same slice to calculate the LAA\/AA ratio. Of the 389 patients, TEE showed thrombus in 15 (3.9%), SEC in 33 (8.5%), and no abnormality in 341 (87.7%) patients. Using TEE findings as the reference standard, the respective sensitivity, specificity, positive predictive value, and negative predictive value of the LAA\/AA HU ratio for detecting LAA thrombus were 100.0, 96.8, 55.6, and 100.0%; those of the LAA\/AA iodine concentration ratio were 100.0, 99.2, 83.3, and 100.0%; and those of the LAA\/AA Z\n                      <jats:sub>\n                        <jats:italic>eff<\/jats:italic>\n                      <\/jats:sub>\n                      ratio were 100.0, 98.9, 79.0, and 100.0%. The areas under the receiver operator characteristic curve (AUC) of the LAA\/AA iodine concentration ratio (0.978; 95% CI 0.945\u20131.000) and Z\n                      <jats:sub>\n                        <jats:italic>eff<\/jats:italic>\n                      <\/jats:sub>\n                      ratio (0.962; 95% CI 0.913\u20131.000) were significantly larger than that of the LAA\/AA HU ratio (0.828; 95% CI 0.714\u20130.942) in differentiating the thrombus from the SEC (both\n                      <jats:italic>P<\/jats:italic>\n                      &amp;lt; 0.05). Although the AUC of the LAA\/AA iodine concentration ratio was larger than that of the LAA\/AA Z\n                      <jats:sub>\n                        <jats:italic>eff<\/jats:italic>\n                      <\/jats:sub>\n                      ratio, no significant difference was found between them (\n                      <jats:italic>P<\/jats:italic>\n                      =\n                      <jats:italic>0.259<\/jats:italic>\n                      ).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>\n                      The dual-energy CT-derived iodine concentration and the Z\n                      <jats:sub>\n                        <jats:italic>eff<\/jats:italic>\n                      <\/jats:sub>\n                      showed better diagnostic performance than the conventional HU in early-phase cardiac CT in detecting LAA thrombus and differentiating the thrombus from the circulatory stasis. However, these results need to be validated in large-cohort studies with late-phase images.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fcvm.2022.809688","type":"journal-article","created":{"date-parts":[[2022,7,22]],"date-time":"2022-07-22T08:53:00Z","timestamp":1658479980000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["Detection of left atrial appendage thrombus by dual-energy computed tomography-derived imaging biomarkers in patients with atrial fibrillation"],"prefix":"10.3389","volume":"9","author":[{"given":"Wenhuan","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mingxi","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fangfang","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weiwei","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xianbo","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaojuan","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qi","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,7,22]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1093\/eurheartj\/ehi825","article-title":"Prevalence, incidence and lifetime risk of atrial fibrillation: the Rotterdam study.","volume":"27","author":"Heeringa","year":"2006","journal-title":"Eur Heart J."},{"key":"B2","doi-asserted-by":"publisher","first-page":"1042","DOI":"10.1161\/01.CIR.0000140263.20897.42","article-title":"Lifetime risk for development of atrial fibrillation: the Framingham heart study.","volume":"110","author":"Lloyd-Jones","year":"2004","journal-title":"Circulation."},{"key":"B3","doi-asserted-by":"publisher","first-page":"1477","DOI":"10.1136\/hrt.2003.027805","article-title":"Electron beam computed tomography for the detection of left atrial thrombi in patients with atrial fibrillation.","volume":"90","author":"Achenbach","year":"2004","journal-title":"Heart."},{"key":"B4","doi-asserted-by":"publisher","first-page":"1609","DOI":"10.1093\/europace\/euw295","article-title":"2016 ESC guidelines for the management of atrial fibrillation developed in collaboration with EACTS.","volume":"18","author":"Kirchhof","year":"2016","journal-title":"Europace."},{"key":"B5","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1093\/eurheartj\/ehaa612","article-title":"2020 ESC guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European association for cardio-thoracic surgery (EACTS): the task force for the diagnosis and management of atrial fibrillation of the european society of cardiology (ESC) developed with the special contribution of the European heart rhythm association (EHRA) of the ESC.","volume":"42","author":"Hindricks","year":"2021","journal-title":"Eur Heart J."},{"key":"B6","doi-asserted-by":"publisher","first-page":"1126","DOI":"10.1016\/j.jacc.2010.11.002","article-title":"ACCF\/ASE\/AHA\/ASNC\/HFSA\/HRS\/SCAI\/SCCM\/SCCT\/SCMR 2011 appropriate use criteria for echocardiography.","volume":"57","author":"Douglas","year":"2011","journal-title":"J Am Coll Cardiol."},{"key":"B7","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1016\/j.echo.2010.08.013","article-title":"Safety of transesophageal echocardiography.","volume":"23","author":"Hilberath","year":"2010","journal-title":"J Am Soc Echocardiogr."},{"key":"B8","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1093\/ije\/dyab123","article-title":"Excess all-cause mortality and COVID-19-related mortality: a temporal analysis in 22 countries, from January until August 2020.","volume":"51","author":"Achilleos","year":"2022","journal-title":"Int J Epidemiol."},{"key":"B9","doi-asserted-by":"publisher","first-page":"1251","DOI":"10.1016\/j.jcmg.2014.08.009","article-title":"The left atrial appendage: anatomy, function, and noninvasive evaluation.","volume":"7","author":"Beigel","year":"2014","journal-title":"JACC Cardiovasc Imaging."},{"key":"B10","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1038\/nrcardio.2014.77","article-title":"Cardiac imaging for assessment of left atrial appendage stasis and thrombosis.","volume":"11","author":"Romero","year":"2014","journal-title":"Nat Rev Cardiol."},{"key":"B11","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1007\/s00330-016-4411-6","article-title":"Assessments of pulmonary vein and left atrial anatomical variants in atrial fibrillation patients for catheter ablation with cardiac CT.","volume":"27","author":"Chen","year":"2017","journal-title":"Eur Radiol."},{"key":"B12","doi-asserted-by":"publisher","first-page":"794","DOI":"10.1097\/RLI.0b013e318184cd6c","article-title":"Diagnostic accuracy of cardiac 64-slice computed tomography in detecting atrial thrombi. Comparative study with transesophageal echocardiography and cardiac surgery.","volume":"43","author":"Feuchtner","year":"2008","journal-title":"Invest Radiol."},{"key":"B13","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/j.jcin.2019.08.054","article-title":"Expert recommendations on cardiac computed tomography for planning transcatheter left atrial appendage occlusion.","volume":"13","author":"Korsholm","year":"2020","journal-title":"JACC Cardiovasc Interv."},{"key":"B14","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1161\/CIRCIMAGING.112.000153","article-title":"Detection of left atrial appendage thrombus by cardiac computed tomography in patients with atrial fibrillation: a meta-analysis.","volume":"6","author":"Romero","year":"2013","journal-title":"Circ Cardiovasc Imaging."},{"key":"B15","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1016\/j.amjcard.2013.03.018","article-title":"Dual-enhancement cardiac computed tomography for assessing left atrial thrombus and pulmonary veins before radiofrequency catheter ablation for atrial fibrillation.","volume":"112","author":"Hur","year":"2013","journal-title":"Am J Cardiol."},{"key":"B16","doi-asserted-by":"publisher","first-page":"2471","DOI":"10.1161\/STROKEAHA.110.611293","article-title":"Dual-enhanced cardiac CT for detection of left atrial appendage thrombus in patients with stroke: a prospective comparison study with transesophageal echocardiography.","volume":"42","author":"Hur","year":"2011","journal-title":"Stroke."},{"key":"B17","doi-asserted-by":"publisher","first-page":"2069","DOI":"10.1007\/s00330-018-5736-0","article-title":"How accurate and precise are CT based measurements of iodine concentration? A comparison of the minimum detectable concentration difference among single source and dual source dual energy CT in a phantom study.","volume":"29","author":"Euler","year":"2019","journal-title":"Eur Radiol."},{"key":"B18","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1007\/s00330-013-3040-6","article-title":"Accuracy of dual-energy computed tomography for the measurement of iodine concentration using cardiac CT protocols: validation in a phantom model.","volume":"24","author":"Koonce","year":"2014","journal-title":"Eur Radiol."},{"key":"B19","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1148\/radiol.2017170896","article-title":"Intermanufacturer comparison of dual-energy CT iodine quantification and monochromatic attenuation: a phantom study.","volume":"287","author":"Jacobsen","year":"2018","journal-title":"Radiology."},{"key":"B20","doi-asserted-by":"publisher","first-page":"W221","DOI":"10.2214\/AJR.16.17325","article-title":"Characterization of incidental renal mass with dual-energy CT: diagnostic accuracy of effective atomic number maps for discriminating nonenhancing cysts from enhancing masses.","volume":"209","author":"Mileto","year":"2017","journal-title":"AJR Am J Roentgenol."},{"key":"B21","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1016\/j.atherosclerosis.2017.03.025","article-title":"Clinical application of effective atomic number for classifying non-calcified coronary plaques by dual-energy computed tomography.","volume":"261","author":"Nakajima","year":"2017","journal-title":"Atherosclerosis."},{"key":"B22","doi-asserted-by":"publisher","first-page":"W17","DOI":"10.2214\/AJR.18.20843","article-title":"Preoperative diagnosis of regional lymph node metastasis of colorectal cancer with quantitative parameters from dual-energy CT.","volume":"213","author":"Yang","year":"2019","journal-title":"AJR Am J Roentgenol."},{"key":"B23","doi-asserted-by":"publisher","first-page":"834","DOI":"10.1016\/j.acra.2015.03.004","article-title":"The value of nonenhanced single-source dual-energy CT for differentiating metastases from adenoma in adrenal glands.","volume":"22","author":"Ju","year":"2015","journal-title":"Acad Radiol."},{"key":"B24","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.1007\/s00330-020-07195-9","article-title":"Improved differentiation between primary lung cancer and pulmonary metastasis by combining dual-energy CT-derived biomarkers with conventional CT attenuation.","volume":"31","author":"Deniffel","year":"2021","journal-title":"Eur Radiol."},{"key":"B25","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/s0735-1097(86)80275-3","article-title":"Transesophageal two-dimensional echocardiography for the detection of left atrial appendage thrombus.","volume":"7","author":"Aschenberg","year":"1986","journal-title":"J Am Coll Cardiol."},{"key":"B26","doi-asserted-by":"publisher","first-page":"1191","DOI":"10.1016\/0301-5629(95)02006-3","article-title":"Quantification of blood echogenicity: evaluation of a semiquantitative method of grading spontaneous echo contrast.","volume":"21","author":"Fatkin","year":"1995","journal-title":"Ultrasound Med Biol."},{"key":"B27","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1148\/radiol.2491071544","article-title":"Thrombus in the left atrial appendage in stroke patients: detection with cardiac CT angiography\u2013a preliminary report.","volume":"249","author":"Hur","year":"2008","journal-title":"Radiology."},{"key":"B28","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1016\/j.ahj.2007.08.004","article-title":"Left atrial appendage filling defects identified by multidetector computed tomography in patients undergoing radiofrequency pulmonary vein antral isolation: a comparison with transesophageal echocardiography.","volume":"154","author":"Kim","year":"2007","journal-title":"Am Heart J."},{"key":"B29","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1016\/j.amjcard.2013.09.037","article-title":"Comparison of transesophageal echocardiography versus computed tomography for detection of left atrial appendage filling defect (thrombus).","volume":"113","author":"Budoff","year":"2014","journal-title":"Am J Cardiol."},{"key":"B30","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1007\/s10554-016-0973-2","article-title":"Double-contrast, single-phase computed tomography angiography for ruling out left atrial appendage thrombus prior to atrial fibrillation ablation.","volume":"33","author":"Teunissen","year":"2017","journal-title":"Int J Cardiovasc Imaging."},{"key":"B31","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1002\/mp.12000","article-title":"Dual-energy CT quantitative imaging: a comparison study between twin-beam and dual-source CT scanners.","volume":"44","author":"Almeida","year":"2017","journal-title":"Med Phys."},{"key":"B32","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1148\/radiol.2015142631","article-title":"Dual- and Multi-Energy CT: principles, technical approaches, and clinical applications.","volume":"276","author":"Mccollough","year":"2015","journal-title":"Radiology."},{"key":"B33","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.ijcard.2019.04.079","article-title":"Detection of left atrial appendage thrombi by third-generation dual-source dual-energy CT: iodine concentration versus conventional enhancement measurements.","volume":"292","author":"Li","year":"2019","journal-title":"Int J Cardiol."},{"key":"B34","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1148\/radiol.12111691","article-title":"Cardioembolic stroke: dual-energy cardiac CT for differentiation of left atrial appendage thrombus and circulatory stasis.","volume":"263","author":"Hur","year":"2012","journal-title":"Radiology."},{"key":"B35","doi-asserted-by":"publisher","first-page":"1765","DOI":"10.1016\/j.ejrad.2016.07.019","article-title":"Differentiation of benign and malignant lung lesions: dual-energy computed tomography findings.","volume":"85","author":"Gonzalez-Perez","year":"2016","journal-title":"Eur J Radiol."}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2022.809688\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,22]],"date-time":"2022-07-22T08:53:03Z","timestamp":1658479983000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2022.809688\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,22]]},"references-count":35,"alternative-id":["10.3389\/fcvm.2022.809688"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2022.809688","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,22]]},"article-number":"809688"}}