{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T04:56:23Z","timestamp":1790744183356,"version":"4.1.0"},"reference-count":44,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,9,21]],"date-time":"2022-09-21T00:00:00Z","timestamp":1663718400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:p>Open thoracoabdominal aortic aneurysm (TAAA) repair is a complex and challenging operation with a high incidence of serious complications, and high perioperative mortality and morbidity. Left heart bypass (LHB) is a circulatory support system used to perfuse the distal aorta during TAAA operation, and the advantages of LHB include guaranteeing distal perfusion, reducing the use of heparin, and diminishing the risk of bleeding and postoperative neurological deficits. In China, the circuit for TAAA repair is deficient, and far from the perfusion requirements. We designed a modular multifunctional LHB circuit for TAAA repair. The modular circuit consisted of cannulation pipelines, functional consumables connection pipelines, and accessory pipelines. The accessory pipelines make up lines for selective visceral perfusion and kidney perfusion, suckers and rapid infusion. The circuit can be assembled according to surgical requirements. The ultrafilter and heat exchanger are integrated into the circuit to fulfill the basic demands of LHB. The LHB circuit also has pipelines for selective visceral perfusion to the celiac artery and superior mesenteric artery and renal perfusion pipelines. Meanwhile, the reserved pipelines facilitate the quick switch from LHB to conventional cardiopulmonary bypass (CPB). The reserved pipelines reduce the time of reassembling the CPB circuit. Moreover, the rapid infusion was integrated into the LHB circuit, which can rapid infusion when massive hemorrhage during the open procedures such as exposure and reconstruction of the aorta. The ultrafiltration can diminish the consequent hemodilution of hemorrhage and rapid infusion. A hemoperfusion cartridge also can be added to reduce the systemic inflammatory during operation. The circuit can meet the needs of LHB and quickly switch to conventional CPB. No oxygenator was required during LHB, which reduce the use of heparin and reduce the risk of bleeding. The heat exchanger contributes to temperature regulation; ultrafiltration, arterial filter, and rapid-infusion facilitated the blood volume management and are useful to maintain hemodynamic stability. This circuit made the assembly of the LHB circuit more easily, and more efficient, which may contribute to the TAAA repair operation performed in lower volume centers easily. 26 patients who received TAAA repair under the modular multifunctional LHB from January 2018-March 2022 were analyzed, and we achieved acceptable clinical outcomes. The in-hospital mortality and 30-day postoperative mortality were 15.4%, and the postoperative incidences of paraparesis (4%), stroke (4%), and AKI need hemodialysis (12%) were not particularly high, based on the limited patients sample size in short research period duration.<\/jats:p>","DOI":"10.3389\/fcvm.2022.944287","type":"journal-article","created":{"date-parts":[[2022,9,21]],"date-time":"2022-09-21T07:43:00Z","timestamp":1663746180000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":9,"title":["The application of modular multifunctional left heart bypass circuit system integrated with ultrafiltration in thoracoabdominal aortic aneurysm repair"],"prefix":"10.3389","volume":"9","author":[{"given":"Lingjin","family":"Huang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuliang","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qinghua","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fanyan","family":"Luo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiajia","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lian","family":"Duan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhi","family":"Ye","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chengliang","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,9,21]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"191","DOI":"10.23736\/S0021-9509.21.11776-8","article-title":"A history of open thoracoabdominal aortic aneurysm repair: Perspective from Houston.","volume":"62","author":"Green","year":"2021","journal-title":"J Cardiovasc Surg (Torino)."},{"key":"B2","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1016\/j.ejvs.2022.02.003","article-title":"Outcome of elective and emergency open thoraco-abdominal aortic aneurysm repair in 255 cases: A retrospective single centre study.","volume":"63","author":"Gombert","year":"2022","journal-title":"Eur J Vasc Endovasc Surg."},{"key":"B3","doi-asserted-by":"publisher","first-page":"1135","DOI":"10.1016\/j.jvs.2021.09.021","article-title":"Risk factors associated with long-term mortality and complications after thoracoabdominal aortic aneurysm repair.","volume":"75","author":"Rocha","year":"2022","journal-title":"J Vasc Surg."},{"key":"B4","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1016\/j.jtcvs.2019.09.148","article-title":"Outcomes after endovascular versus open thoracoabdominal aortic aneurysm repair: A population-based study.","volume":"161","author":"Rocha","year":"2021","journal-title":"J Thorac Cardiovasc Surg."},{"key":"B5","doi-asserted-by":"publisher","first-page":"1396","DOI":"10.1016\/j.jvs.2019.06.216","article-title":"Systematic review of contemporary outcomes of endovascular and open thoracoabdominal aortic aneurysm repair.","volume":"71","author":"Rocha","year":"2020","journal-title":"J Vasc Surg."},{"key":"B6","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.jtcvs.2015.12.050","article-title":"Outcomes of 3309 thoracoabdominal aortic aneurysm repairs.","volume":"151","author":"Coselli","year":"2016","journal-title":"J Thorac Cardiovasc Surg."},{"key":"B7","doi-asserted-by":"publisher","first-page":"2168","DOI":"10.1016\/j.jtcvs.2018.08.094","article-title":"Open surgery for descending thoracic aorta in an endovascular era.","volume":"157","author":"Fujikawa","year":"2019","journal-title":"J Thorac Cardiovasc Surg."},{"key":"B8","doi-asserted-by":"publisher","first-page":"1374","DOI":"10.1093\/ejcts\/ezv415","article-title":"Open thoracoabdominal aortic aneurysm repair in the modern era: Results from a 20-year single-centre experience.","volume":"49","author":"Murana","year":"2016","journal-title":"Eur J Cardiothorac Surg."},{"key":"B9","doi-asserted-by":"publisher","first-page":"295","DOI":"10.23736\/S0021-9509.21.11825-7","article-title":"Open thoracoabdominal aortic aneurysm surgery technique: How we do it.","volume":"62","author":"Tanaka","year":"2021","journal-title":"J Cardiovasc Surg (Torino)."},{"key":"B10","doi-asserted-by":"crossref","first-page":"708","DOI":"10.1093\/icvts\/ivw450","article-title":"Spinal cord protection during thoracoabdominal aortic replacement: Spinal cord perfusion maintenance.","volume":"24","author":"Uchino","year":"2017","journal-title":"Interact Cardiovasc Thorac Surg."},{"key":"B11","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1002\/bjs.1800820517","article-title":"Surgical repair of thoracoabdominal aortic aneurysm: 10 years\u2019 experience.","volume":"82","author":"Gilling-Smith","year":"1995","journal-title":"Br J Surg."},{"key":"B12","doi-asserted-by":"publisher","first-page":"634","DOI":"10.1016\/j.jvs.2018.03.410","article-title":"Open repair of thoracoabdominal aortic aneurysms in experienced centers.","volume":"68","author":"Moulakakis","year":"2018","journal-title":"J Vasc Surg."},{"key":"B13","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1016\/j.jvs.2011.05.086","article-title":"Hospital volume of thoracoabdominal aneurysm repair does not affect mortality in California.","volume":"2","author":"Anna","year":"2011","journal-title":"J Vasc Surg."},{"key":"B14","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/j.jvs.2005.10.070","article-title":"Thirty-day mortality statistics underestimate the risk of repair of thoracoabdominal aortic aneurysms: A statewide experience.","volume":"43","author":"Rigberg","year":"2006","journal-title":"J Vasc Surg."},{"key":"B15","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1016\/j.jvs.2020.05.027","article-title":"Increased hospital volume is associated with reduced mortality after thoracoabdominal aortic aneurysm repair.","volume":"73","author":"Polanco","year":"2021","journal-title":"J Vasc Surg."},{"key":"B16","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/j.ejvs.2016.06.005","article-title":"Editor\u2019s choice - management of descending thoracic aorta diseases: Clinical practice guidelines of the European society for vascular surgery (ESVS).","volume":"53","author":"Riambau","year":"2017","journal-title":"Eur J Vasc Endovasc Surg."},{"key":"B17","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1097\/SLA.0000000000004982","article-title":"Midterm outcomes of a prospective, nonrandomized study to evaluate endovascular repair of complex aortic aneurysms using fenestrated-branched endografts.","volume":"274","author":"Oderich","year":"2021","journal-title":"Ann Surg."},{"key":"B18","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1016\/j.ejvs.2018.10.030","article-title":"Editor\u2019s choice - hospital incidence, treatment, and in hospital mortality following open and endovascular surgery for thoraco-abdominal aortic aneurysms in Germany from 2005 to 2014: Secondary data analysis of the nationwide German DRG microdata.","volume":"57","author":"Geisb\u00fcsch","year":"2019","journal-title":"Eur J Vasc Endovasc Surg."},{"key":"B19","doi-asserted-by":"publisher","first-page":"102703","DOI":"10.1016\/j.amsu.2021.102703","article-title":"Re-intervention rate in endovascular vs open surgical repair for abdominal aortic aneurysms.","volume":"69","author":"Rahim","year":"2021","journal-title":"Ann Med Surg."},{"key":"B20","doi-asserted-by":"publisher","DOI":"10.1016\/j.avsg.2022.04.002","article-title":"Midterm outcomes of endovascular versus open surgical repair of intact descending thoracic aneurysms in patients with connective tissue disorders.","author":"Muncan","year":"2022","journal-title":"Ann Vasc Surg."},{"key":"B21","doi-asserted-by":"publisher","first-page":"1934","DOI":"10.1016\/j.jvs.2020.09.034","article-title":"Health care costs of endovascular compared with open thoracoabdominal aortic aneurysm repair.","volume":"73","author":"Rocha","year":"2021","journal-title":"J Vasc Surg."},{"key":"B22","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1016\/j.ejvs.2019.10.016","article-title":"Editor\u2019s choice - European society for vascular surgery (ESVS) 2020 clinical practice guidelines on the management of vascular graft and endograft infections.","volume":"59","author":"Chakf\u00e9","year":"2020","journal-title":"Eur J Vasc Endovasc Surg."},{"key":"B23","doi-asserted-by":"publisher","first-page":"588","DOI":"10.1016\/j.ejvs.2017.07.026","article-title":"Editor\u2019s choice - open thoracic and thoracoabdominal aortic repair in patients with connective tissue disease.","volume":"54","author":"Keschenau","year":"2017","journal-title":"Eur J Vasc Endovasc Surg."},{"key":"B24","doi-asserted-by":"publisher","first-page":"2434","DOI":"10.1111\/ans.16287","article-title":"Left heart bypass versus circulatory arrest for open repair of thoracoabdominal aortic pathologies.","volume":"90","author":"Papadimas","year":"2020","journal-title":"Anz J Surg."},{"key":"B25","doi-asserted-by":"publisher","first-page":"1113","DOI":"10.1111\/jcmm.17165","article-title":"The dynamic changes in autophagy activity and its role in lung injury after deep hypothermic circulatory arrest.","volume":"26","author":"Kong","year":"2022","journal-title":"J Cell Mol Med."},{"key":"B26","doi-asserted-by":"publisher","first-page":"754","DOI":"10.1007\/s11748-020-01399-y","article-title":"Hypothermic circulatory arrest induced coagulopathy: Rotational thromboelastometry analysis.","volume":"68","author":"Ise","year":"2020","journal-title":"Gen Thorac Cardiovasc Surg."},{"key":"B27","doi-asserted-by":"publisher","first-page":"1029","DOI":"10.1053\/j.jvca.2021.08.020","article-title":"Rotational thromboelastometry-guided transfusion protocol to reduce allogeneic blood transfusion in proximal aortic surgery with deep hypothermic circulatory arrest.","volume":"36","author":"Karrar","year":"2022","journal-title":"J Cardiothorac Vasc Anesth."},{"key":"B28","doi-asserted-by":"publisher","first-page":"678","DOI":"10.1093\/ejcts\/ezu053","article-title":"Deep hypothermic circulatory arrest versus non-deep hypothermic beating heart strategy in descending thoracic or thoracoabdominal aortic surgery.","volume":"46","author":"Yoo","year":"2014","journal-title":"Eur J Cardio Thorac."},{"key":"B29","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1182\/ject-2100022","article-title":"Hybrid left heart bypass circuit for repair of the descending aorta in an 8-kg williams syndrome patient.","volume":"53","author":"Matte","year":"2021","journal-title":"J Extra Corpor Technol."},{"key":"B30","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1053\/S1043-0679(03)00090-X","article-title":"The use of left heart bypass in the repair of thoracoabdominal aortic aneurysms: Current techniques and results.","volume":"15","author":"Coselli","year":"2003","journal-title":"Semin Thorac Cardiovasc Surg."},{"key":"B31","doi-asserted-by":"publisher","first-page":"2173","DOI":"10.1016\/j.athoracsur.2005.05.060","article-title":"Evolution of risk for neurologic deficit after descending and thoracoabdominal aortic repair.","volume":"80","author":"Safi","year":"2005","journal-title":"Ann Thorac Surg."},{"key":"B32","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/j.hlc.2021.05.092","article-title":"Spinal cord protection of aorto-iliac bypass in open repair of extent ii and III thoracoabdominal aortic aneurysm.","volume":"31","author":"Dong","year":"2022","journal-title":"Heart Lung Circ."},{"key":"B33","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1016\/s1010-7940(00)00499-1","article-title":"Single-clamp technique for aneurysms of the descending thoracic aorta: report of 132 consecutive cases.","volume":"18","author":"Cooley","year":"2000","journal-title":"Eur J Cardiothorac Surg."},{"key":"B34","doi-asserted-by":"publisher","first-page":"1159235759","DOI":"10.1177\/15385744221108049","article-title":"Distal perfusion with modified centrifugal pump circuit in thoracic and thoracoabdominal aortic aneurysm repair.","author":"Ertugay","year":"2022","journal-title":"Vasc Endovascular Surg."},{"key":"B35","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1159\/000514149","article-title":"The efficacy of resin hemoperfusion cartridge on inflammatory responses during adult cardiopulmonary bypass.","volume":"51","author":"He","year":"2022","journal-title":"Blood Purif."},{"key":"B36","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2019.01.120","article-title":"Spinal cord deficit after 1114 extent II open thoracoabdominal aortic aneurysm repairs.","author":"Coselli","year":"2019","journal-title":"J Thorac Cardiovasc Surg."},{"key":"B37","doi-asserted-by":"publisher","first-page":"430","DOI":"10.1053\/j.semtcvs.2021.04.050","article-title":"Acute kidney injury affects mid-term outcomes of thoracoabdominal aortic aneurysms repair.","volume":"34","author":"Henmi","year":"2021","journal-title":"Semin Thorac Cardiovasc Surg."},{"key":"B38","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2021.02.090","article-title":"Renal perfusion with histidine-tryptophan-ketoglutarate compared with ringer\u2019s solution in patients undergoing thoracoabdominal aortic open repair.","author":"Kahlberg","year":"2021","journal-title":"J Thorac Cardiovasc Surg."},{"key":"B39","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1016\/j.athoracsur.2020.09.032","article-title":"Early gastrointestinal complications after open thoracoabdominal aortic aneurysm repair.","volume":"112","author":"Frankel","year":"2021","journal-title":"Ann Thorac Surg."},{"key":"B40","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1016\/j.jclinane.2008.12.028","article-title":"The effect of left heart bypass on pulmonary blood flow and arterial oxygenation during one-lung ventilation in patients undergoing descending thoracic aortic surgery.","volume":"21","author":"Yuki","year":"2009","journal-title":"J Clin Anesth."},{"key":"B41","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1097\/ALN.0b013e3182303a7f","article-title":"Case scenario: Anesthetic considerations for thoracoabdominal aortic aneurysm repair.","volume":"115","author":"Vaughn","year":"2011","journal-title":"Anesthesiology."},{"key":"B42","doi-asserted-by":"publisher","first-page":"1770","DOI":"10.1016\/s0003-4975(01)03058-2","article-title":"Oxygenator support for partial left-heart bypass.","volume":"72","author":"Leach","year":"2001","journal-title":"Ann Thorac Surg."},{"key":"B43","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1053\/j.jvca.2011.12.011","article-title":"Improvement of pao2 during one-lung ventilation with partial left-heart bypass in pediatric patients is caused by increased blood flow to the dependent lung.","volume":"27","author":"Yuki","year":"2013","journal-title":"J Cardiothorac Vasc Anesth."},{"key":"B44","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1053\/j.jvca.2016.09.026","article-title":"Impact of left heart bypass on arterial oxygenation during one-lung ventilation for thoracic aortic surgery.","volume":"31","author":"Suga","year":"2017","journal-title":"J Cardiothorac Vasc Anesth."}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2022.944287\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,21]],"date-time":"2022-09-21T07:43:06Z","timestamp":1663746186000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2022.944287\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,21]]},"references-count":44,"alternative-id":["10.3389\/fcvm.2022.944287"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2022.944287","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,21]]},"article-number":"944287"}}