{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T19:07:38Z","timestamp":1790708858159,"version":"4.1.0"},"reference-count":60,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,1,6]],"date-time":"2023-01-06T00:00:00Z","timestamp":1672963200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:p>In contrast to the advanced development of the left ventricular assist device (LVAD) therapy for advanced heart failure, the mechanical circulatory support (MCS) with biventricular assist device (BVAD) and total artificial heart (TAH) options remain challenging. The treatment strategy of BVAD and TAH therapy largely depends on the support duration. For example, an extracorporeal centrifugal pump, typically referred to as a temporary surgical extracorporeal right ventricular assist device, is implanted for the short term with acute right ventricular failure following LVAD implantation. Meanwhile, off-label use of a durable implantable LVAD is a strategy for long-term right ventricular support. Hence, this review focuses on the current treatment strategies and clinical outcomes based on each ventricle support duration. In addition, the issue of heart failure post-heart transplantation (post-HT) is explored. We will discuss MCS therapy options for post-HT recipients.<\/jats:p>","DOI":"10.3389\/fcvm.2022.972132","type":"journal-article","created":{"date-parts":[[2023,1,6]],"date-time":"2023-01-06T12:51:31Z","timestamp":1673009491000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":14,"title":["Biventricular assist devices and total artificial heart: Strategies and outcomes"],"prefix":"10.3389","volume":"9","author":[{"given":"Taiyo","family":"Kuroda","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chihiro","family":"Miyagi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kiyotaka","family":"Fukamachi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jamshid H.","family":"Karimov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2023,1,6]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm11164901","article-title":"A device strategy-matched comparison analysis among different intermacs profiles: A single center experience.","volume":"11","author":"Caraffa","year":"2022","journal-title":"J Clin Med."},{"key":"B2","doi-asserted-by":"publisher","first-page":"1304","DOI":"10.1016\/j.healun.2018.04.004","article-title":"Interagency registry for mechanically assisted circulatory support report on the total artificial heart.","volume":"37","author":"Arab\u00eda","year":"2018","journal-title":"J Heart Lung Transplant."},{"key":"B3","doi-asserted-by":"publisher","first-page":"e578","DOI":"10.1161\/CIR.0000000000000560","article-title":"Evaluation and management of right-sided heart failure: A scientific statement from the american heart association.","volume":"137","author":"Konstam","year":"2018","journal-title":"Circulation."},{"key":"B4","doi-asserted-by":"publisher","first-page":"3381","DOI":"10.1111\/jocs.15089","article-title":"Outcomes of mechanical support for cardiogenic shock associated with late cardiac allograft failure.","volume":"35","author":"D\u2019Angelo","year":"2020","journal-title":"J Card Surg."},{"key":"B5","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1111\/jocs.14468","article-title":"Heart transplantation from donation after circulatory death donors: Present and future.","volume":"35","author":"Quader","year":"2020","journal-title":"J Card Surg."},{"key":"B6","doi-asserted-by":"publisher","first-page":"1155","DOI":"10.1016\/j.healun.2018.07.022","article-title":"The international thoracic organ transplant registry of the international society for heart and lung transplantation: Thirty-fifth adult heart transplantation report-2018; focus theme: Multiorgan transplantation.","volume":"37","author":"Khush","year":"2018","journal-title":"J Heart Lung Transplant."},{"key":"B7","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1016\/j.athoracsur.2021.12.011","article-title":"Twelfth interagency registry for mechanically assisted circulatory support report: Readmissions after left ventricular assist device.","volume":"113","author":"Shah","year":"2022","journal-title":"Ann Thorac Surg."},{"key":"B8","doi-asserted-by":"publisher","first-page":"1392","DOI":"10.1002\/ejhf.2211","article-title":"Primary results of long-term outcomes in the momentum 3 pivotal trial and continued access protocol study phase: A study of 2200 heartmate 3 left ventricular assist device implants.","volume":"23","author":"Mehra","year":"2021","journal-title":"Eur J Heart Fail."},{"key":"B9","first-page":"163","article-title":"Ventricular interactions during mechanical circulatory support.","volume":"6","author":"Farrar","year":"1994","journal-title":"Semin Thorac Cardiovasc Surg."},{"key":"B10","doi-asserted-by":"publisher","first-page":"1320","DOI":"10.1161\/01.CIR.95.5.1320","article-title":"Septal function during left ventricular unloading.","volume":"95","author":"Moon","year":"1997","journal-title":"Circulation."},{"key":"B11","doi-asserted-by":"publisher","DOI":"10.3390\/jcdd4040018","article-title":"The dark side of the moon: The right ventricle.","volume":"4","author":"Foschi","year":"2017","journal-title":"J Cardiovasc Dev Dis."},{"key":"B12","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1016\/j.athoracsur.2016.02.006","article-title":"Limitations to chronic right ventricular assist device support.","volume":"102","author":"Karimov","year":"2016","journal-title":"Ann Thorac Surg."},{"key":"B13","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/j.ejcts.2011.05.047","article-title":"Liberal use of tricuspid-valve annuloplasty during left-ventricular assist device implantation.","volume":"41","author":"Krishan","year":"2012","journal-title":"Eur J Cardiothorac Surg."},{"key":"B14","doi-asserted-by":"publisher","first-page":"1123","DOI":"10.1016\/j.healun.2015.06.015","article-title":"Right ventricular failure after left ventricular assist devices.","volume":"34","author":"Lampert","year":"2015","journal-title":"J Heart Lung Transplant."},{"key":"B15","doi-asserted-by":"publisher","first-page":"2294","DOI":"10.1016\/j.jacc.2021.09.1362","article-title":"Evolution of late right heart failure with left ventricular assist devices and association with outcomes.","volume":"78","author":"Rame","year":"2021","journal-title":"J Am Coll Cardiol."},{"key":"B16","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1080\/17434440.2019.1635006","article-title":"Mechanical circulatory support for the right ventricle in combination with a left ventricular assist device.","volume":"16","author":"Shimada","year":"2019","journal-title":"Expert Rev Med Devices."},{"key":"B17","doi-asserted-by":"publisher","first-page":"1316","DOI":"10.1016\/j.jtcvs.2009.11.020","article-title":"Right ventricular failure in patients with the heartmate ii continuous-flow left ventricular assist device: Incidence, risk factors, and effect on outcomes.","volume":"139","author":"Kormos","year":"2010","journal-title":"J Thorac Cardiovasc Surg."},{"key":"B18","doi-asserted-by":"publisher","first-page":"828","DOI":"10.1093\/icvts\/ivw409","article-title":"Contemporary outcome of unplanned right ventricular assist device for severe right heart failure after continuous-flow left ventricular assist device insertion.","volume":"24","author":"Yoshioka","year":"2017","journal-title":"Interact Cardiovasc Thorac Surg."},{"key":"B19","doi-asserted-by":"publisher","first-page":"1768","DOI":"10.1016\/j.athoracsur.2018.11.051","article-title":"Outcomes after extracorporeal right ventricular assist device combined with durable left ventricular assist device support.","volume":"107","author":"Khorsandi","year":"2019","journal-title":"Ann Thorac Surg."},{"key":"B20","doi-asserted-by":"publisher","first-page":"1215","DOI":"10.1111\/jocs.16329","article-title":"Trends and outcomes following total artificial heart as bridge to transplant from the unos database.","volume":"37","author":"Coyan","year":"2022","journal-title":"J Card Surg."},{"key":"B21","doi-asserted-by":"publisher","first-page":"314","DOI":"10.1161\/CIRCULATIONAHA.116.025290","article-title":"Mechanical circulatory support devices for acute right ventricular failure.","volume":"136","author":"Kapur","year":"2017","journal-title":"Circulation."},{"key":"B22","doi-asserted-by":"publisher","first-page":"2181","DOI":"10.1016\/S0003-4975(99)00753-5","article-title":"Preoperative risk factors for right ventricular failure after implantable left ventricular assist device insertion.","volume":"68","author":"Fukamachi","year":"1999","journal-title":"Ann Thorac Surg."},{"key":"B23","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1016\/j.cardfail.2015.10.019","article-title":"Pulmonary artery pulsatility index is associated with right ventricular failure after left ventricular assist device surgery.","volume":"22","author":"Morine","year":"2016","journal-title":"J Card Fail."},{"key":"B24","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.healun.2015.06.009","article-title":"Pulmonary artery pulsatility index predicts right ventricular failure after left ventricular assist device implantation.","volume":"35","author":"Kang","year":"2016","journal-title":"J Heart Lung Transplant."},{"key":"B25","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1097\/MAT.0000000000001467","article-title":"Right ventricular global longitudinal strain as a predictor of acute and early right heart failure post left ventricular assist device implantation.","volume":"68","author":"Liang","year":"2022","journal-title":"Asaio J."},{"key":"B26","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1016\/j.healun.2017.03.014","article-title":"A new \u201ctwist\u201d on right heart failure with left ventricular assist systems.","volume":"36","author":"Houston","year":"2017","journal-title":"J Heart Lung Transplant."},{"key":"B27","doi-asserted-by":"publisher","first-page":"1399","DOI":"10.1016\/j.healun.2018.08.008","article-title":"An international multicenter experience of biventricular support with heartmate 3 ventricular assist systems.","volume":"37","author":"Lavee","year":"2018","journal-title":"J Heart Lung Transplant."},{"key":"B28","doi-asserted-by":"publisher","first-page":"822","DOI":"10.1016\/j.healun.2010.02.012","article-title":"Long-term biventricular support with the heartware implantable continuous flow pump.","volume":"29","author":"Hetzer","year":"2010","journal-title":"J Heart Lung Transplant."},{"key":"B29","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.healun.2020.12.006","article-title":"The results of a single-center experience with heartmate 3 in a biventricular configuration.","volume":"40","author":"McGiffin","year":"2021","journal-title":"J Heart Lung Transplant."},{"key":"B30","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1016\/j.athoracsur.2017.08.019","article-title":"Biventricular support with intracorporeal, continuous flow, centrifugal ventricular assist devices.","volume":"105","author":"Arab\u00eda","year":"2018","journal-title":"Ann Thorac Surg."},{"key":"B31","doi-asserted-by":"publisher","first-page":"1298","DOI":"10.1016\/j.healun.2018.07.019","article-title":"Clinical implications of the total artificial heart: Adversity and progress.","volume":"37","author":"Pagani","year":"2018","journal-title":"J Heart Lung Transplant."},{"key":"B32","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1111\/aor.13959","article-title":"Aeson\u2014the carmat total artificial heart is approved for enrollment in the united states.","volume":"45","author":"Han","year":"2021","journal-title":"Artif Organs."},{"key":"B33","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.healun.2017.09.002","article-title":"A bioprosthetic total artificial heart for end-stage heart failure: Results from a pilot study.","volume":"37","author":"Latr\u00e9mouille","year":"2018","journal-title":"J Heart Lung Transplant."},{"key":"B34","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.healun.2009.05.034","article-title":"An innovative, sensorless, pulsatile, continuous-flow total artificial heart: Device design and initial in vitro study.","volume":"29","author":"Fukamachi","year":"2010","journal-title":"J Heart Lung Transplant."},{"key":"B35","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1016\/j.jtcvs.2015.06.023","article-title":"First report of 90-day support of 2 calves with a continuous-flow total artificial heart.","volume":"150","author":"Karimov","year":"2015","journal-title":"J Thorac Cardiovasc Surg."},{"key":"B36","doi-asserted-by":"publisher","first-page":"1555","DOI":"10.1111\/aor.14237","article-title":"Pulsatility hemodynamics during speed modulation of continuous-flow total artificial heart in a chronic in vivo model.","volume":"46","author":"Kuroda","year":"2022","journal-title":"Artif Organs."},{"key":"B37","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1109\/MSPEC.2019.8818588","article-title":"The maglev heart.","volume":"56","author":"Greatrex","year":"2019","journal-title":"IEEE Spectrum."},{"key":"B38","doi-asserted-by":"publisher","first-page":"816","DOI":"10.1111\/j.1525-1594.2008.00633.x","article-title":"The bivacor rotary biventricular assist device: Concept and in vitro investigation.","volume":"32","author":"Timms","year":"2008","journal-title":"Artif Organs."},{"key":"B39","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1111\/aor.14077","article-title":"Anatomical human fitting of the bivacor total artificial heart.","volume":"46","author":"Emmanuel","year":"2022","journal-title":"Artif Organs."},{"key":"B40","doi-asserted-by":"publisher","first-page":"1585","DOI":"10.1111\/aor.14223","article-title":"Hemodynamic characterization of the realheart\u00ae total artificial heart with a hybrid cardiovascular simulator.","volume":"46","author":"Fresiello","year":"2022","journal-title":"Artif Organs."},{"key":"B41","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1111\/aor.14056","article-title":"Video-based valve motion combined with computational fluid dynamics gives stable and accurate simulations of blood flow in the realheart total artificial heart.","volume":"46","author":"Kelly","year":"2022","journal-title":"Artif Organs."},{"key":"B42","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1111\/aor.13542","article-title":"Evaluation of the novel total artificial heart realheart in a pilot human fitting study.","volume":"44","author":"Pieper","year":"2020","journal-title":"Artif Organs."},{"key":"B43","doi-asserted-by":"publisher","first-page":"3278","DOI":"10.1053\/j.jvca.2022.02.022","article-title":"Right heart failure management: Focus on mechanical support options.","author":"Bhatia","year":"2022","journal-title":"J Cardiothorac Vasc Anesth."},{"key":"B44","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1097\/MAT.0000000000000117","article-title":"Thoratec centrimag for temporary treatment of refractory cardiogenic shock or severe cardiopulmonary insufficiency: A systematic literature review and meta-analysis of observational studies.","volume":"60","author":"Borisenko","year":"2014","journal-title":"Asaio J."},{"key":"B45","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCHEARTFAILURE.121.008358","article-title":"Combining minimally invasive surgery with ultra-fast-track anesthesia in heartmate 3 patients: A pilot study.","volume":"15","author":"Ahmad","year":"2022","journal-title":"Circ Heart Fail."},{"key":"B46","doi-asserted-by":"publisher","first-page":"1448","DOI":"10.1016\/j.healun.2018.08.001","article-title":"Outcomes of patients with right ventricular failure requiring short-term hemodynamic support with the impella rp device.","volume":"37","author":"Anderson","year":"2018","journal-title":"J Heart Lung Transplant."},{"key":"B47","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1093\/icvts\/ivz322","article-title":"Novel percutaneous dual-lumen cannula-based right ventricular assist device provides effective support for refractory right ventricular failure after left ventricular assist device implantation.","volume":"30","author":"Salna","year":"2020","journal-title":"Interact CardioVasc Thorac Surg."},{"key":"B48","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1007\/s12265-018-9820-2","article-title":"Mechanical unloading by fulminant myocarditis: Lv-impella, ecmella, bi-pella, and propella concepts.","volume":"12","author":"Tsch\u00f6pe","year":"2019","journal-title":"J Cardiovasc Transl Res."},{"key":"B49","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.117.006670","article-title":"Acute biventricular mechanical circulatory support for cardiogenic shock.","volume":"6","author":"Kuchibhotla","year":"2017","journal-title":"J Am Heart Assoc."},{"key":"B50","doi-asserted-by":"publisher","first-page":"e12","DOI":"10.1161\/CIRCINTERVENTIONS.112.000018","article-title":"Percutaneous circulatory support for biventricular failure.","volume":"6","author":"Nagy","year":"2013","journal-title":"Circ Cardiovasc Interv."},{"key":"B51","doi-asserted-by":"publisher","first-page":"1006","DOI":"10.1161\/CIRCHEARTFAILURE.115.002374","article-title":"First successful use of 2 axial flow catheters for percutaneous biventricular circulatory support as a bridge to a durable left ventricular assist device.","volume":"8","author":"Kapur","year":"2015","journal-title":"Circ Heart Fail."},{"key":"B52","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.116.003636","article-title":"Biventricular circulatory support using 2 axial flow catheters for cardiogenic shock without the need for surgical vascular access.","volume":"9","author":"Aghili","year":"2016","journal-title":"Circ Cardiovasc Interv."},{"key":"B53","doi-asserted-by":"publisher","first-page":"2237","DOI":"10.1093\/eurheartj\/ehac204","article-title":"Heart transplantation: Focus on donor recovery strategies, left ventricular assist devices, and novel therapies.","volume":"43","author":"Crespo-Leiro","year":"2022","journal-title":"Eur Heart J."},{"key":"B54","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1002\/ejhf.886","article-title":"Late graft failure in heart transplant recipients: Incidence, risk factors and clinical outcomes.","volume":"20","author":"L\u00f3pez-Sainz","year":"2018","journal-title":"Eur J Heart Fail."},{"key":"B55","doi-asserted-by":"publisher","DOI":"10.1111\/ctr.13482","article-title":"Description and analysis of patients and outcomes following third-time heart transplantation: An analysis of the united network for organ sharing database from 1985 to 2017.","volume":"33","author":"Bhalla","year":"2019","journal-title":"Clin Transplant."},{"key":"B56","doi-asserted-by":"publisher","first-page":"e77","DOI":"10.1097\/MAT.0000000000001217","article-title":"Total artificial heart as bridge to cardiac retransplantation.","volume":"67","author":"Zadikany","year":"2021","journal-title":"Asaio J."},{"key":"B57","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1016\/j.healun.2018.05.001","article-title":"Multicenter experience with durable biventricular assist devices.","volume":"37","author":"Shah","year":"2018","journal-title":"J Heart Lung Transplant."},{"key":"B58","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1097\/MAT.0000000000000645","article-title":"Durable biventricular support using right atrial placement of the heartware hvad.","volume":"64","author":"Tran","year":"2018","journal-title":"Asaio J."},{"key":"B59","doi-asserted-by":"publisher","first-page":"926","DOI":"10.1111\/aor.13675","article-title":"Right atrial versus right ventricular heartware hvad position in patients on biventricular heartware hvad support: A systematic review.","volume":"44","author":"Maynes","year":"2020","journal-title":"Artif Organs."},{"key":"B60","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2017.00131","article-title":"The total artificial heart in end-stage congenital heart disease.","volume":"8","author":"Villa","year":"2017","journal-title":"Front Physiol."}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2022.972132\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,6]],"date-time":"2023-01-06T12:51:35Z","timestamp":1673009495000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2022.972132\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,6]]},"references-count":60,"alternative-id":["10.3389\/fcvm.2022.972132"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2022.972132","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,6]]},"article-number":"972132"}}