{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T15:50:02Z","timestamp":1753890602048,"version":"3.41.2"},"reference-count":10,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,6,22]],"date-time":"2023-06-22T00:00:00Z","timestamp":1687392000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100005632","name":"National Centre of Research and Development of Poland","doi-asserted-by":"publisher","award":["\u00a0"],"award-info":[{"award-number":["\u00a0"]}],"id":[{"id":"10.13039\/501100005632","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>In this study, a new probe was designed to enable electrocardiography of a rotated heart during cardiac surgery when skin electrodes became non-functional. This probe adhered non-invasively to the epicardium and collected the ECG signal independently from the position of the heart. The study compared the accuracy of cardiac ischemia detection between classic skin and epicardial electrodes in an animal model.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Using six pigs, an open chest model was devised with cardiac ischemia induction by coronary artery ligation in two non-physiologic heart positions. Both the accuracy and the time of detection of electrocardiographic symptoms of acute cardiac ischemia were compared between skin and epicardial methods of signal collection.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Heart rotation to expose either the anterior or the posterior wall resulted in a distortion or loss of the ECG signal collected by skin electrodes after coronary artery ligation, standard skin ECG monitoring did not reveal any ischemia symptoms. Attachment of an epicardial probe on the anterior and posterior walls helped in the recovery of the normal ECG wave. After ligation of the coronary artery, the epicardial probes recorded cardiac ischemia within 40\u2005s.<\/jats:p><\/jats:sec><jats:sec><jats:title>Discussion<\/jats:title><jats:p>This study highlighted the effectiveness of ECG monitoring with epicardial probes in a rotated heart. It can be concluded that epicardial probes can detect the presence of acute ischemia of a rotated heart when skin ECG monitoring becomes ineffective.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fcvm.2023.1111651","type":"journal-article","created":{"date-parts":[[2023,6,22]],"date-time":"2023-06-22T12:43:34Z","timestamp":1687437814000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Rapid cardiac ischemia detection with an epicardial graphene probe"],"prefix":"10.3389","volume":"10","author":[{"given":"Grzegorz","family":"Suwalski","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marek","family":"Galanty","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Beata","family":"Deg\u00f3rska","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jacek","family":"Sterna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan","family":"Frymus","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mikhal","family":"Baranski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Piotr","family":"Tr\u0119bacz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Janczak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandra","family":"Lepak-Kuc","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ma\u0142gorzata","family":"Jakubowska","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2023,6,22]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1007\/BF03017418","article-title":"Mechanisms of hemodynamic changes during off-pump coronary artery bypass surgery","volume":"49","author":"Couture","year":"2002","journal-title":"Review Can J Anaesth"},{"key":"B2","doi-asserted-by":"publisher","first-page":"1348","DOI":"10.1016\/S0003-4975(98)00226-4","article-title":"Vertical displacement of the beating heart by the octopus tissue stabilizer: influence on coronary flow","volume":"65","author":"Grundeman","year":"1998","journal-title":"Ann Thorac Surg"},{"key":"B3","doi-asserted-by":"publisher","first-page":"S393","DOI":"10.1088\/0967-3334\/29\/6\/S33","article-title":"Monitoring of myocardium state during off-pump coronary artery by-pass grafting","volume":"29","author":"Wtorek","year":"2008","journal-title":"Physiol Meas"},{"key":"B4","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1186\/1749-8090-1-12","article-title":"Ischemia monitoring in off-pump coronary artery bypass surgery using intravascular near-infrared spectroscopy","volume":"1","author":"Bernet","year":"2006","journal-title":"J Cardiothorac Surg"},{"key":"B5","doi-asserted-by":"publisher","first-page":"965","DOI":"10.1213\/01.ANE.0000130614.45647.81","article-title":"Transesophageal echocardiography for monitoring segmental wall motion during off-pump coronary artery bypass surgery","volume":"99","author":"Wang","year":"2004","journal-title":"Anesth Analg"},{"key":"B6","doi-asserted-by":"publisher","first-page":"S1033","DOI":"10.1016\/S0003-4975(01)02946-0","article-title":"Off-pump coronary artery bypass may decrease the patency of saphenous vein grafts","volume":"72","author":"Kim","year":"2001","journal-title":"Ann Thorac Surg"},{"key":"B7","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1097\/imi.0b013e31821692b1","article-title":"Short- and long-term outcomes in octogenarian patients undergoing off-pump coronary artery bypass grafting compared with on-pump coronary artery bypass grafting","volume":"6","author":"Sarin","year":"2011","journal-title":"Innovations"},{"key":"B8","doi-asserted-by":"publisher","first-page":"e009934","DOI":"10.1161\/JAHA.118.009934","article-title":"Off-pump coronary artery bypass grafting: 30 years of debate","volume":"7","author":"Gaudino","year":"2018","journal-title":"J Am Heart Assoc"},{"key":"B9","doi-asserted-by":"publisher","first-page":"475","DOI":"10.4103\/0971-9784.185534","article-title":"Intraoperative conversion to on-pump coronary artery bypass grafting is independently associated with higher mortality in patients undergoing off-pump coronary artery bypass grafting: a propensity-matched analysis","volume":"19","author":"Borde","year":"2016","journal-title":"Ann Card Anaesth"},{"key":"B10","doi-asserted-by":"publisher","first-page":"8567","DOI":"10.1038\/s41598-019-45093-3","article-title":"Long term outcomes of the off-pump and on-pump coronary artery bypass grafting in a high-volume center","volume":"12","author":"Matkovic","year":"2019","journal-title":"Sci Rep"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2023.1111651\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,22]],"date-time":"2023-06-22T12:43:37Z","timestamp":1687437817000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2023.1111651\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,22]]},"references-count":10,"alternative-id":["10.3389\/fcvm.2023.1111651"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2023.1111651","relation":{},"ISSN":["2297-055X"],"issn-type":[{"type":"electronic","value":"2297-055X"}],"subject":[],"published":{"date-parts":[[2023,6,22]]},"article-number":"1111651"}}