{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T04:02:32Z","timestamp":1776744152523,"version":"3.51.2"},"reference-count":36,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,9,6]],"date-time":"2023-09-06T00:00:00Z","timestamp":1693958400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>The prevalence of young patients with cardiac implantable electronic devices (CIED) is steadily increasing, accompanied by a rise in the occurrence of complications related to CIEDs. Consequently, transvenous lead extraction (TLE) has become a crucial treatment approach for such individuals.<\/jats:p><\/jats:sec><jats:sec><jats:title>Objective<\/jats:title><jats:p>The purpose of this study was to examine the characteristics and procedural outcomes of young patients who undergo TLE, with a specific focus on identifying independent risk factors associated with adverse events.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>All patients in the GALLERY (GermAn Laser Lead Extraction RegistrY) were categorized into two groups based on their age at the time of enrollment: 45 years or younger, and over 45 years. A subgroup analysis was conducted specifically for the younger population. In this analysis, predictor variables for all-cause mortality, procedural complications, and procedural failure were evaluated using multivariable analyses.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>We identified 160 patients aged 45 years or younger with a mean age of 35.3\u2009\u00b1\u20097.6 years and 42.5% (<jats:italic>n<\/jats:italic>\u2009=\u200968) female patients. Leading extraction indication was lead dysfunction in 51.3% of cases, followed by local infections in 20.6% and systemic infections in 16.9%. The most common device to be extracted were implantable cardioverter-defibrillators (ICD) with 52.5%. Mean number of leads per patient was 2.2\u2009\u00b1\u20091.0. Median age of the oldest indwelling lead was 91.5 [54.75\u2013137.5] months. Overall complication rate was 3.8% with 1.9% minor and 1.9% major complications. Complete procedural success was achieved in 90.6% of cases. Clinical procedural success rate was 98.1%. Procedure-related mortality was 0.0%. The all-cause in-hospital mortality rate was 2.5%, with septic shock identified as the primary cause of mortality. Multivariable analysis revealed CKD (OR: 19.0; 95% CI: 1.84\u2013194.9; <jats:italic>p<\/jats:italic>\u2009=\u20090.018) and systemic infection (OR: 12.7; 95% CI: 1.14\u2013142.8; <jats:italic>p<\/jats:italic>\u2009=\u20090.039) as independent predictor for all-cause mortality. Lead age\u2009\u2265\u200910 years (OR: 14.58, 95% CI: 1.36\u2013156.2; <jats:italic>p<\/jats:italic>\u2009=\u20090.027) was identified as sole independent risk factor for procedural complication.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>TLE in young patients is safe and effective with a procedure-related mortality rate of 0.0%. CKD and systemic infection are predictors for all-cause mortality, whereas lead age\u2009\u2265\u200910 years was identified as independent risk factor for procedural complications in young patients undergoing TLE.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fcvm.2023.1251055","type":"journal-article","created":{"date-parts":[[2023,9,6]],"date-time":"2023-09-06T16:57:11Z","timestamp":1694019431000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":7,"title":["Procedural outcome &amp; risk prediction in young patients undergoing transvenous lead extraction\u2014a GALLERY subgroup analysis"],"prefix":"10.3389","volume":"10","author":[{"given":"Enida","family":"Rexha","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Da-Un","family":"Chung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Heiko","family":"Burger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naser","family":"Ghaffari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomas","family":"Madej","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Virgilijus","family":"Ziaukas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kambiz","family":"Hassan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hermann","family":"Reichenspurner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nele","family":"Gessler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephan","family":"Willems","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Butter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon","family":"Pecha","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samer","family":"Hakmi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2023,9,6]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"ii1","DOI":"10.1093\/europace\/eux258","article-title":"A decade of information on the use of cardiac implantable electronic devices and interventional electrophysiological procedures in the European society of cardiology countries: 2017 report from the European heart rhythm association","volume":"19","author":"Raatikainen","year":"2017","journal-title":"Europace"},{"key":"B2","doi-asserted-by":"publisher","first-page":"1013","DOI":"10.1111\/j.1540-8159.2011.03150.x","article-title":"The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009\u2014a world society of Arrhythmia\u2019s project","volume":"34","author":"Mond","year":"2011","journal-title":"Pacing Clin Electrophysiol"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1071","DOI":"10.1016\/j.jacep.2019.06.016","article-title":"Trends of cardiovascular implantable electronic device infection in 3 decades: a population-based study","volume":"5","author":"Dai","year":"2019","journal-title":"JACC Clin Electrophysiol"},{"key":"B4","doi-asserted-by":"publisher","first-page":"iv3","DOI":"10.1093\/europace\/euab042","article-title":"Epidemiology of cardiac implantable electronic device infections: incidence and risk factors","volume":"23","author":"Han","year":"2021","journal-title":"Europace"},{"key":"B5","doi-asserted-by":"publisher","first-page":"e002798","DOI":"10.1161\/JAHA.115.002798","article-title":"Multi-center, community-based cardiac implantable electronic devices registry: population, device utilization, and outcomes","volume":"5","author":"Gupta","year":"2016","journal-title":"J Am Heart Assoc"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1627","DOI":"10.1093\/europace\/euac056","article-title":"The German laser lead extraction registry: GALLERY","volume":"24","author":"Pecha","year":"2022","journal-title":"Europace"},{"key":"B7","doi-asserted-by":"publisher","first-page":"4946","DOI":"10.1093\/eurheartj\/ehac576","article-title":"Risk factors for cardiac implantable electronic device infections: a nationwide Danish study","volume":"43","author":"Olsen","year":"2022","journal-title":"Eur Heart J"},{"key":"B8","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/j.hrthm.2022.10.004","article-title":"Transvenous lead extraction in patients with systemic cardiac device-related infection-procedural outcome and risk prediction: a GALLERY subgroup analysis","volume":"20","author":"Chung","year":"2023","journal-title":"Hear Rhythm"},{"key":"B9","doi-asserted-by":"publisher","first-page":"e503","DOI":"10.1016\/j.hrthm.2017.09.001","article-title":"2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction","volume":"14","author":"Kusumoto","year":"2017","journal-title":"Hear Rhythm"},{"key":"B10","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.1093\/europace\/euy050","article-title":"2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS\/HRS\/LAHRS","volume":"20","author":"Bongiorni","year":"2018","journal-title":"Europace"},{"key":"B11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jacep.2016.06.009","article-title":"Cardiac implantable electronic device infections: added complexity and suboptimal outcomes with previously abandoned leads","volume":"3","author":"Hussein","year":"2017","journal-title":"JACC Clin Electrophysiol"},{"key":"B12","doi-asserted-by":"publisher","DOI":"10.17219\/acem\/159531","article-title":"Lead-related tricuspid regurgitation and ventricle dysfunction: current management and future perspectives","volume":"32","author":"Chod\u00f3r-Rozwadowska","year":"2023","journal-title":"Adv Clin Exp Med"},{"key":"B13","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1016\/j.jacc.2009.08.070","article-title":"Lead extraction in the contemporary setting: the LExICon study: an observational retrospective study of consecutive laser lead extractions","volume":"55","author":"Wazni","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"B14","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1093\/europace\/euy307","article-title":"Procedural outcomes associated with transvenous lead extraction in patients with abandoned leads: an ESC-EHRA ELECTRa (European lead extraction controlled) registry sub-analysis","volume":"21","author":"Segreti","year":"2019","journal-title":"Europace"},{"key":"B15","doi-asserted-by":"publisher","first-page":"9601","DOI":"10.1038\/s41598-022-13769-y","article-title":"Disparities in transvenous lead extraction in young adults","volume":"12","author":"Kutarski","year":"2022","journal-title":"Sci Rep"},{"key":"B16","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.jjcc.2017.01.011","article-title":"Neointimal fibrotic lead encapsulation\u2014clinical challenges and demands for implantable cardiac electronic devices","volume":"70","author":"Keiler","year":"2017","journal-title":"J Cardiol"},{"key":"B17","doi-asserted-by":"publisher","first-page":"602179","DOI":"10.3389\/fcvm.2020.602179","article-title":"Quantitative and qualitative assessment of adhesive thrombo-fibrotic lead encapsulations (TFLE) of pacemaker and ICD leads in arrhythmia patients\u2014a post mortem study","volume":"7","author":"Keiler","year":"2020","journal-title":"Front Cardiovasc Med"},{"key":"B18","doi-asserted-by":"publisher","first-page":"2995","DOI":"10.1093\/eurheartj\/ehx080","article-title":"The European lead extraction controlled (ELECTRa) study: a European heart rhythm association (EHRA) registry of transvenous lead extraction outcomes","volume":"38","author":"Bongiorni","year":"2017","journal-title":"Eur Heart J"},{"key":"B19","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1016\/j.hrthm.2017.01.030","article-title":"Outcomes of lead extraction in young adults","volume":"14","author":"El-Chami","year":"2017","journal-title":"Hear Rhythm"},{"key":"B20","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1016\/j.jacep.2021.11.008","article-title":"Lead extraction at a pediatric\/congenital heart disease center: the importance of patient age at implant","volume":"8","author":"Pham","year":"2022","journal-title":"JACC Clin Electrophysiol"},{"key":"B21","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1111\/j.1540-8159.2006.00376.x","article-title":"Effectiveness of excimer laser-assisted pacing and ICD lead extraction in children and young adults","volume":"29","author":"Moak","year":"2006","journal-title":"Pacing Clin Electrophysiol"},{"key":"B22","doi-asserted-by":"publisher","first-page":"2393","DOI":"10.1161\/CIRCULATIONAHA.112.001120","article-title":"Multi-institutional study of implantable defibrillator lead performance in children and young adults: results of the pediatric lead extractability and survival evaluation (PLEASE) study","volume":"127","author":"Atallah","year":"2013","journal-title":"Circulation"},{"key":"B23","doi-asserted-by":"publisher","first-page":"2474","DOI":"10.1161\/CIRCULATIONAHA.106.663807","article-title":"Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years","volume":"115","author":"Kleemann","year":"2007","journal-title":"Circulation"},{"key":"B24","doi-asserted-by":"publisher","first-page":"2196","DOI":"10.1016\/j.hrthm.2014.08.011","article-title":"Major predictors of fibrous adherences in transvenous implantable cardioverter-defibrillator lead extraction","volume":"11","author":"Segreti","year":"2014","journal-title":"Hear Rhythm"},{"key":"B25","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1111\/pace.14195","article-title":"Safety and efficacy of transvenous lead extraction in octogenarians using powered extraction sheaths","volume":"44","author":"Burger","year":"2021","journal-title":"Pacing Clin Electrophysiol"},{"key":"B26","doi-asserted-by":"publisher","first-page":"1540","DOI":"10.1111\/pace.14310","article-title":"Transvenous lead extraction: the influence of age on patient outcomes in the PROMET study cohort","volume":"44","author":"Akhtar","year":"2021","journal-title":"Pacing Clin Electrophysiol"},{"key":"B27","doi-asserted-by":"publisher","first-page":"1703","DOI":"10.1093\/europace\/euz238","article-title":"Reported mortality with rotating sheaths vs. laser sheaths for transvenous lead extraction","volume":"21","author":"Diaz","year":"2019","journal-title":"Europace"},{"key":"B28","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1093\/europace\/euac200","article-title":"A head-to-head comparison of laser vs. powered mechanical sheaths as first choice and second line extraction tools","volume":"25","author":"Zsigmond","year":"2023","journal-title":"Europace"},{"key":"B29","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1111\/pace.14631","article-title":"Chronic kidney disease is associated with increased all-cause mortality in transvenous lead extraction: a systematic review and meta-analysis","volume":"46","author":"Tan","year":"2023","journal-title":"Pacing Clin Electrophysiol"},{"key":"B30","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1093\/europace\/euaa086","article-title":"Long-term follow-up of abandoned transvenous defibrillator leads: a nationwide cohort study","volume":"22","author":"Elgaard","year":"2020","journal-title":"Europace"},{"key":"B31","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1161\/CIRCEP.110.954107","article-title":"Lead extraction is preferred for lead revisions and system upgrades: when less is more","volume":"3","author":"Maytin","year":"2010","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"B32","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.hrthm.2008.10.012","article-title":"Do abandoned leads pose risk to implantable cardioverter-defibrillator patients?","volume":"6","author":"Glikson","year":"2009","journal-title":"Hear Rhythm"},{"key":"B33","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1053\/eupc.2001.0202","article-title":"Malfunction of endocardial defibrillator leads and lead extraction: where do they meet?","volume":"4","author":"Bracke","year":"2002","journal-title":"Europace"},{"key":"B34","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1093\/europace\/euv053","article-title":"Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysis","volume":"17","author":"Polyzos","year":"2015","journal-title":"Europace"},{"key":"B35","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1161\/CIRCULATIONAHA.117.027636","article-title":"Outcomes associated with extraction versus capping and abandoning pacing and defibrillator leads","volume":"136","author":"Pokorney","year":"2017","journal-title":"Circulation"},{"key":"B36","doi-asserted-by":"publisher","first-page":"1462","DOI":"10.1093\/europace\/euab037","article-title":"Risk stratification of patients undergoing transvenous lead extraction with the ELECTRa registry outcome score (EROS): an ESC EHRA EORP European lead extraction controlled ELECTRa registry analysis","volume":"23","author":"Sidhu","year":"2021","journal-title":"Europace"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2023.1251055\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,6]],"date-time":"2023-09-06T16:57:14Z","timestamp":1694019434000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2023.1251055\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,6]]},"references-count":36,"alternative-id":["10.3389\/fcvm.2023.1251055"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2023.1251055","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,6]]},"article-number":"1251055"}}