{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T04:19:46Z","timestamp":1780633186696,"version":"3.54.1"},"reference-count":34,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,7,2]],"date-time":"2024-07-02T00:00:00Z","timestamp":1719878400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Even though the optimal management of a moderate or large residual shunt following patent foramen ovale (PFO) closure is open to question, recent data confirmed that it is associated with an increased risk of stroke recurrence.<\/jats:p><\/jats:sec><jats:sec><jats:title>Case summary<\/jats:title><jats:p>A 48-year-old woman, a migraineur with visual aura, was diagnosed with a PFO associated with a huge multifenestrated atrial septal aneurysm (mfASA) and a moderate right-to-left shunt, detectable only after a Valsalva maneuver on contrast-transthoracic echocardiography. Brain magnetic resonance imaging showed a 1-mm silent white matter lesion in the right frontal lobe. Although the indication was not supported by guidelines, a transcatheter PFO closure was performed at another center with implantation of a large, equally sized, double-disc device (Figulla UNI 33\/33\u2005mm). At 6-month follow-up, a 2D\/3D transesophageal echocardiography (TEE) color Doppler showed incorrect orientation of the device, which was not parallel to the interatrial septum, with two discs failing to capture the aortic muscular rim and partially protruding in the right atrium; furthermore, a 4\u2005mm\u2009\u00d7\u20097\u2005mm ASA fenestration was documented with a residual bidirectional shunt. Thereafter, the same team performed a minimally invasive cardiac surgery under femoro-femoral cardiopulmonary bypass; however, the procedure proved ineffective and was complicated by postoperative pericarditis with pericardial effusion, requiring further rehospitalization 1\u2005month later due to persistent pericarditis, bilateral pleuritis, phrenic nerve palsy, and atrial flutter, which was treated with amiodarone. The patient asked for a second opinion, and our multidisciplinary heart team decided to offer a percutaneous redo intervention. An uneventful implantation of a regular PFO occluder (Figulla Flex II 16\/18\u2005mm) across the septal defect was performed successfully. Twelve-month follow-up with 2D TTE color Doppler and contrast transcranial Doppler showed correct position and good interaction between the two devices, with no residual shunt.<\/jats:p><\/jats:sec><jats:sec><jats:title>Discussion<\/jats:title><jats:p>In addition to the incorrect indication for PFO closure and the failure of minimally invasive surgery, the procedural mishap in this case could have been due to the inappropriate implantation of the first large device within the tunnel. It would have been better to deploy the same large device in the most central fenestration, covering the PFO and a greater part of the remaining mfASA at the same time.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fcvm.2024.1367515","type":"journal-article","created":{"date-parts":[[2024,7,2]],"date-time":"2024-07-02T04:56:55Z","timestamp":1719896215000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Case Report: Persistent residual shunt after a first percutaneous PFO closure followed by minimally invasive surgical failure: third time is a charm"],"prefix":"10.3389","volume":"11","author":[{"given":"Eustaquio M.","family":"Onorato","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Alamanni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giovanni","family":"Monizzi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Angelo","family":"Mastrangelo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio Luca","family":"Bartorelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2024,7,2]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"335","DOI":"10.7326\/M17-2679","article-title":"Device closure versus medical therapy alone for patent foramen ovale in patients with cryptogenic stroke: a systematic review and meta-analysis","volume":"168","author":"Shah","year":"2018","journal-title":"Ann Intern Med"},{"key":"B2","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1007\/s11886-019-1137-5","article-title":"Device closure of patent foramen ovale for cryptogenic stroke: patient selection and outcomes according to new randomized trials","volume":"21","author":"Carroll","year":"2019","journal-title":"Curr Cardiol Rep"},{"key":"B3","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1016\/j.jstrokecerebrovasdis.2012.12.002","article-title":"New trends in neurosonology and cerebral hemodynamics\u2014an update","volume":"1","author":"Caputi","year":"2012","journal-title":"Perspect Med"},{"key":"B4","doi-asserted-by":"publisher","first-page":"e219","DOI":"10.1016\/j.jstrokecerebrovasdis.2012.12.002","article-title":"Residual shunt after patent foramen ovale closure: preliminary results from Italian Patent Foramen Ovale Survey","volume":"22","author":"Caputi","year":"2013","journal-title":"J Stroke Cerebrovasc Dis"},{"key":"B5","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1002\/ccd.25453","article-title":"Comparison of residual shunt rates in five devices used to treat patent foramen ovale","volume":"84","author":"Matsumura","year":"2014","journal-title":"Catheter Cardiovasc Interv"},{"key":"B6","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1002\/ccd.20221","article-title":"Implantation of a second closure device in patients with residual shunt after percutaneous closure of patent foramen ovale","volume":"63","author":"Schwerzmann","year":"2004","journal-title":"Catheter Cardiovasc Interv"},{"key":"B7","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1002\/ccd.22475","article-title":"Management of residual shunts after initial percutaneous patent foramen ovale closure: a single center experience with immediate and long-term follow-up","volume":"76","author":"Diaz","year":"2010","journal-title":"Catheter Cardiovasc Interv"},{"key":"B8","doi-asserted-by":"publisher","first-page":"833","DOI":"10.4244\/eijv5i7a139","article-title":"Device closure of residual shunt after percutaneous closure of patent foramen ovale","volume":"5","author":"Majunke","year":"2010","journal-title":"EuroIntervention"},{"key":"B9","doi-asserted-by":"publisher","first-page":"858","DOI":"10.4244\/EIJ-D-17-00061","article-title":"Second transcatheter closure for residual shunt following percutaneous closure of patent foramen ovale","volume":"13","author":"Susuri","year":"2017","journal-title":"EuroIntervention"},{"key":"B10","doi-asserted-by":"publisher","first-page":"950","DOI":"10.1002\/ccd.25097","article-title":"Residual shunting after percutaneous PFO closure: how to manage and how to close","volume":"82","author":"Butera","year":"2013","journal-title":"Catheter Cardiovasc Interv"},{"key":"B11","doi-asserted-by":"publisher","first-page":"3182","DOI":"10.1093\/eurheartj\/ehy649","article-title":"European Position paper on the management of patients with patent foramen ovale. General approach and left circulation thromboembolism","volume":"40","author":"Pristipino","year":"2019","journal-title":"Eur Heart J"},{"key":"B12","doi-asserted-by":"publisher","first-page":"100039","DOI":"10.1016\/j.jscai.2022.100039","article-title":"SCAI guidelines for the management of patent foramen ovale","volume":"1","author":"Kavinsky","year":"2022","journal-title":"J Soc Cardiovasc Angiograph Interv"},{"key":"B13","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1046\/j.1540-8175.2002.00501.x","article-title":"Intracardiac echocardiography during catheter-based procedures: ultrasound system, examination technique, and image presentation","volume":"19","author":"Zanchetta","year":"2002","journal-title":"Echocardiography"},{"key":"B14","doi-asserted-by":"publisher","first-page":"1677","DOI":"10.1016\/j.jacc.2003.08.023","article-title":"Intracardiac echocardiography-guided transcatheter closure of secundum atrial septal defect: a new efficient device selection method","volume":"42","author":"Zanchetta","year":"2003","journal-title":"J Am Coll Cardiol"},{"key":"B15","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1002\/ccd.20584","article-title":"Iatrogenic atrial septal defect, erosion of the septum primum after device closure of a patent foramen ovale as a new medical entity","volume":"68","author":"Meier","year":"2006","journal-title":"Catheter Cardiovasc Interv"},{"key":"B16","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1002\/ccd.25333","article-title":"Iatrogenic erosion of the septum primum resulting in an atrial septal defect with left-to-right shunt: a rare pitfall of patent foramen ovale percutaneous closure","volume":"84","author":"Scacciatella","year":"2014","journal-title":"Catheter Cardiovasc Interv"},{"key":"B17","doi-asserted-by":"publisher","first-page":"1377","DOI":"10.1093\/ehjci\/jeu143","article-title":"Echocardiographic findings in simple and complex patent foramen ovale before and after transcatheter closure","volume":"15","author":"Vitarelli","year":"2014","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"B18","doi-asserted-by":"publisher","first-page":"382","DOI":"10.4244\/EIJV9I3A61","article-title":"Residual shunt after percutaneous closure of patent foramen ovale with AMPLATZER occluder devices\u2014influence of anatomic features: a transcranial Doppler and intracardiac echocardiography study","volume":"9","author":"Marchese","year":"2013","journal-title":"EuroIntervention"},{"key":"B19","doi-asserted-by":"publisher","first-page":"244","DOI":"10.14503\/THIJ-17-6582","article-title":"Importance of persistent right-to-left shunt after patent foramen ovale closure in cryptogenic stroke patients","volume":"47","author":"He","year":"2020","journal-title":"Tex Heart Inst J"},{"key":"B20","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1186\/2047-783x-16-1-13","article-title":"Risk and fate of residual interatrial shunting after transcatheter closure of patent foramen ovale: a long-term follow-up study","volume":"16","author":"Hammerstingl","year":"2011","journal-title":"Eur J Med Res"},{"key":"B21","doi-asserted-by":"publisher","first-page":"2140","DOI":"10.1161\/01.STR.0000137764.07815.de","article-title":"Does transcatheter closure of patent foramen ovale really \u201cshut the door?\u201d A prospective study with transcranial Doppler","volume":"35","author":"Anzola","year":"2004","journal-title":"Stroke"},{"key":"B22","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.ijcard.2008.02.031","article-title":"Long-term follow up after percutaneous closure of PFO in 357 patients with paradoxical embolism: difference in occlusion systems and influence of atrial septum aneurysm","volume":"134","author":"von Bardeleben","year":"2009","journal-title":"Int J Cardiol"},{"key":"B23","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1002\/ccd.24511","article-title":"Recurrent events after percutaneous closure of patent foramen ovale","volume":"82","author":"Wallenborn","year":"2013","journal-title":"Catheter Cardiovasc Interv"},{"key":"B24","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/j.jstrokecerebrovasdis.2018.10.006","article-title":"Residual shunt after patent foramen ovale device closure in patients with cryptogenic stroke: serial bubble contrast transesophageal echocardiography data","volume":"28","author":"Moon","year":"2019","journal-title":"J Stroke Cerebrovasc Dis"},{"key":"B25","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1159\/000527457","article-title":"A systematic review and meta-analysis of the association between residual shunts after patent foramen ovale closure and long-term cerebrovascular events","volume":"52","author":"Liu","year":"2023","journal-title":"Cerebrovasc Dis"},{"key":"B26","doi-asserted-by":"publisher","first-page":"e203","DOI":"10.1212\/WNL.0000000000012188","article-title":"Effect of patent foramen ovale closure after stroke on circulatory biomarkers","volume":"97","author":"Deng","year":"2021","journal-title":"Neurology"},{"key":"B27","doi-asserted-by":"publisher","first-page":"e364","DOI":"10.1161\/STR.0000000000000375","article-title":"2021 guideline for the prevention of stroke in patients with stroke and transient ischemic attack: a guideline from the American Heart Association\/American Stroke Association","volume":"52","author":"Kleindorfer","year":"2021","journal-title":"Stroke"},{"key":"B28","doi-asserted-by":"publisher","first-page":"1311","DOI":"10.1016\/s0735-1097(00)00514-3","article-title":"Closure of patent foramen ovale for paradoxical emboli: intermediate-term risk of recurrent neurological events following transcatheter device placement","volume":"35","author":"Hung","year":"2000","journal-title":"J Am Coll Cardiol"},{"key":"B29","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1002\/ccd.26518","article-title":"Long-term follow-up after PFO device closure: outcomes and complications in a single-center experience","volume":"89","author":"Taggart","year":"2017","journal-title":"Catheter Cardiovasc Interv"},{"key":"B30","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1212\/WNL.0000000000009443","article-title":"Practice advisory update summary: patent foramen ovale and secondary stroke prevention: report of the guideline subcommittee of the American Academy of Neurology","volume":"94","author":"Mess\u00e9","year":"2020","journal-title":"Neurology"},{"key":"B31","doi-asserted-by":"publisher","first-page":"1066","DOI":"10.1016\/j.jtcvs.2006.12.002","article-title":"Avoiding vascular complications during minimally invasive, totally endoscopic intracardiac surgery","volume":"133","author":"Jeanmart","year":"2007","journal-title":"J Thorac Cardiovasc Surg"},{"key":"B32","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1007\/s12055-019-00843-w","article-title":"Minimally invasive mitral valve repair","volume":"36","author":"Marin Cuartas","year":"2020","journal-title":"Indian J Thorac Cardiovasc Surg"},{"key":"B33","first-page":"470","article-title":"Early and late outcomes after minimally invasive mitral valve repair surgery","volume":"24","author":"Akowuah","year":"2015","journal-title":"J Heart Valve Dis"},{"key":"B34","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1055\/s-0037-1601342","article-title":"Long-term outcomes after minimally invasive aortic valve surgery through right anterior minithoracotomy","volume":"65","author":"Reser","year":"2017","journal-title":"Thorac Cardiovasc Surg"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2024.1367515\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,2]],"date-time":"2024-07-02T04:56:58Z","timestamp":1719896218000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2024.1367515\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,2]]},"references-count":34,"alternative-id":["10.3389\/fcvm.2024.1367515"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2024.1367515","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,2]]},"article-number":"1367515"}}