{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T18:14:05Z","timestamp":1787595245510,"version":"build-2736575974"},"reference-count":140,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,4,8]],"date-time":"2024-04-08T00:00:00Z","timestamp":1712534400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:p>Transcatheter aortic valve replacement (TAVR) has increasingly become a safe, feasible, and widely accepted alternative surgical treatment for patients with severe symptomatic aortic stenosis. However, the incidence of conduction abnormalities associated with TAVR, including left bundle branch block (LBBB) and high-degree atrioventricular block (HAVB), remains high and is often correlated with risk factors such as the severity of valvular calcification, preexisting conditions in patients, and procedural factors. The existing research results on the impact of post-TAVR conduction abnormalities and permanent pacemaker (PPM) requirements on prognosis, including all-cause mortality and rehospitalization, remain contradictory, with varied management strategies for post-TAVR conduction system diseases across different institutions. This review integrates the latest research in the field, offering a comprehensive discussion of the mechanisms, risk factors, consequences, and management of post-TAVR conduction abnormalities. This study provides insights into optimizing patient prognosis and explores the potential of novel strategies, such as conduction system pacing, to minimize the risk of adverse clinical outcomes.<\/jats:p>","DOI":"10.3389\/fcvm.2024.1370244","type":"journal-article","created":{"date-parts":[[2024,4,8]],"date-time":"2024-04-08T05:00:00Z","timestamp":1712552400000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":13,"title":["Predictors, clinical impact, and management strategies for conduction abnormalities after transcatheter aortic valve replacement: an updated review"],"prefix":"10.3389","volume":"11","author":[{"given":"Qingyun","family":"Yu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qingan","family":"Fu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunlei","family":"Xia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanqing","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2024,4,8]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1016\/j.mayocp.2018.01.020","article-title":"Management of patients with aortic valve stenosis","volume":"93","author":"Kanwar","year":"2018","journal-title":"Mayo Clin Proc"},{"key":"B2","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1016\/j.pcad.2014.02.006","article-title":"The global burden of aortic stenosis","volume":"56","author":"Thaden","year":"2014","journal-title":"Prog Cardiovasc Dis"},{"key":"B3","doi-asserted-by":"publisher","first-page":"16006","DOI":"10.1038\/nrdp.2016.6","article-title":"Calcific aortic stenosis","volume":"2","author":"Lindman","year":"2016","journal-title":"Nat Rev Dis Primers"},{"key":"B4","doi-asserted-by":"publisher","first-page":"1875","DOI":"10.1001\/jama.2022.5776","article-title":"Effect of transcatheter aortic valve implantation vs surgical aortic valve replacement on all-cause mortality in patients with aortic stenosis: a randomized clinical trial","volume":"327","author":"Toff","year":"2022","journal-title":"JAMA"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1890","DOI":"10.1093\/eurheartj\/ehaa036","article-title":"Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial","volume":"41","author":"Thiele","year":"2020","journal-title":"Eur Heart J"},{"key":"B6","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1016\/j.tcm.2021.10.002","article-title":"The selection of transcatheter heart valves in transcatheter aortic valve replacement","volume":"32","author":"Tugaoen","year":"2022","journal-title":"Trends Cardiovasc Med"},{"key":"B7","doi-asserted-by":"publisher","first-page":"3143","DOI":"10.1093\/eurheartj\/ehz275","article-title":"Transcatheter aortic valve implantation vs. surgical aortic valve replacement for treatment of symptomatic severe aortic stenosis: an updated meta-analysis","volume":"40","author":"Siontis","year":"2019","journal-title":"Eur Heart J"},{"key":"B8","doi-asserted-by":"publisher","first-page":"1532","DOI":"10.1016\/j.jacc.2019.06.076","article-title":"Transcatheter versus surgical aortic valve replacement in low-risk patients","volume":"74","author":"Kolte","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1161\/CIRCULATIONAHA.117.028352","article-title":"Conduction disturbances after transcatheter aortic valve replacement: current Status and future perspectives","volume":"136","author":"Auffret","year":"2017","journal-title":"Circulation"},{"key":"B10","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.jcin.2020.09.063","article-title":"Incidence, predictors, and implications of permanent pacemaker requirement after transcatheter aortic valve replacement","volume":"14","author":"Sammour","year":"2021","journal-title":"JACC Cardiovasc Interv"},{"key":"B11","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1016\/j.jcin.2014.10.026","article-title":"European experience with the second-generation Edwards SAPIEN XT transcatheter heart valve in patients with severe aortic stenosis: 1-year outcomes from the SOURCE XT registry","volume":"8","author":"Schymik","year":"2015","journal-title":"JACC Cardiovasc Interv"},{"key":"B12","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1002\/ccd.30870","article-title":"Implantation depth of balloon-expandable transcatheter heart valves and risks for permanent pacemaker implantation and midterm adverse events","volume":"102","author":"Pellegrini","year":"2023","journal-title":"Catheter Cardiovasc Interv"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1240","DOI":"10.4244\/EIJ-D-19-00541","article-title":"In-hospital and thirty-day outcomes of the SAPIEN 3 ultra balloon-expandable transcatheter aortic valve: the S3U registry","volume":"15","author":"Saia","year":"2020","journal-title":"EuroIntervention"},{"key":"B14","doi-asserted-by":"publisher","first-page":"889","DOI":"10.1002\/ccd.29923","article-title":"Next-generation balloon-expandable myval transcatheter heart valve in low-risk aortic stenosis patients","volume":"99","author":"Garc\u00eda-G\u00f3mez","year":"2022","journal-title":"Catheter Cardiovasc Interv"},{"key":"B15","doi-asserted-by":"publisher","first-page":"443","DOI":"10.3390\/jcm11020443","article-title":"Safety and efficacy of myval implantation in patients with severe bicuspid aortic valve stenosis-A multicenter real-world experience","volume":"11","author":"Elkoumy","year":"2022","journal-title":"J Clin Med"},{"key":"B16","doi-asserted-by":"publisher","first-page":"751","DOI":"10.1002\/ccd.27934","article-title":"Initial experience of a large, self-expanding, and fully recapturable transcatheter aortic valve: the UK & Ireland Implanters\u2019 registry","volume":"93","author":"Dowling","year":"2019","journal-title":"Catheter Cardiovasc Interv"},{"key":"B17","doi-asserted-by":"publisher","first-page":"850","DOI":"10.4244\/EIJ-D-20-00279","article-title":"Thirty-day clinical outcomes of the evolut PRO self-expanding transcatheter aortic valve: the international FORWARD PRO study","volume":"16","author":"Manoharan","year":"2020","journal-title":"EuroIntervention"},{"key":"B18","doi-asserted-by":"publisher","first-page":"e012538","DOI":"10.1161\/CIRCINTERVENTIONS.122.012538","article-title":"Temporal trends and contemporary outcomes after transcatheter aortic valve replacement with evolut PRO\/PRO+ self-expanding valves: insights from the NEOPRO\/NEOPRO-2 registries","volume":"16","author":"Scotti","year":"2023","journal-title":"Circ Cardiovasc Interv"},{"key":"B19","doi-asserted-by":"publisher","first-page":"2398","DOI":"10.1016\/j.jcin.2022.08.057","article-title":"Transcatheter aortic valve replacement with the latest-iteration self-expanding or balloon-expandable valves: the multicenter OPERA-TAVI registry","volume":"15","author":"Costa","year":"2022","journal-title":"JACC Cardiovasc Interv"},{"key":"B20","doi-asserted-by":"publisher","first-page":"1626","DOI":"10.1016\/j.jcin.2023.05.004","article-title":"First-in-human multicenter experience of the newest generation supra-annular self-expanding evolut FX TAVR system","volume":"16","author":"Zaid","year":"2023","journal-title":"JACC Cardiovasc Interv"},{"key":"B21","doi-asserted-by":"publisher","first-page":"e1040","DOI":"10.4244\/EIJ-D-17-00187","article-title":"Transfemoral TAVI using the self-expanding ACURATE neo prosthesis: one-year outcomes of the multicentre \u201cCE-approval cohort.\u201d","volume":"13","author":"M\u00f6llmann","year":"2017","journal-title":"EuroIntervention"},{"key":"B22","doi-asserted-by":"publisher","first-page":"1912","DOI":"10.1007\/s00392-021-01882-3","article-title":"The ACURATE neo2 valve system for transcatheter aortic valve implantation: 30-day and 1-year outcomes","volume":"110","author":"M\u00f6llmann","year":"2021","journal-title":"Clin Res Cardiol"},{"key":"B23","doi-asserted-by":"publisher","first-page":"1538","DOI":"10.1016\/j.jcin.2017.05.021","article-title":"Implantation and 30-day follow-up on all 4 valve sizes within the portico transcatheter aortic bioprosthetic family","volume":"10","author":"M\u00f6llmann","year":"2017","journal-title":"JACC Cardiovasc Interv"},{"key":"B24","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1016\/j.jcin.2023.02.002","article-title":"30-day clinical outcomes of a self-expanding transcatheter aortic valve: the international PORTICO NG study","volume":"16","author":"Reardon","year":"2023","journal-title":"JACC Cardiovasc Interv"},{"key":"B25","doi-asserted-by":"publisher","first-page":"1206","DOI":"10.1002\/ccd.26914","article-title":"Procedural and 30-day clinical outcomes following transcatheter aortic valve replacement with lotus valve: results of the RELEVANT study","volume":"90","author":"Montone","year":"2017","journal-title":"Catheter Cardiovasc Interv"},{"key":"B26","doi-asserted-by":"publisher","first-page":"1339","DOI":"10.1016\/j.jacc.2014.05.067","article-title":"Transcatheter aortic valve replacement for severe symptomatic aortic stenosis using a repositionable valve system: 30-day primary endpoint results from the REPRISE II study","volume":"64","author":"Meredith Am","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"B27","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1016\/j.jcin.2020.09.044","article-title":"Transcatheter aortic valve replacement with the LOTUS edge system: early European experience","volume":"14","author":"Armario","year":"2021","journal-title":"JACC Cardiovasc Interv"},{"key":"B28","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1016\/j.jcin.2019.08.035","article-title":"Three generations of self-expanding transcatheter aortic valves: a report from the STS\/ACC TVT registry","volume":"13","author":"Forrest","year":"2020","journal-title":"JACC Cardiovasc Interv"},{"key":"B29","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/j.jcin.2018.11.036","article-title":"Transcatheter aortic valve replacement with next-generation self-expanding devices: a multicenter, retrospective, propensity-matched comparison of evolut PRO versus acurate neo transcatheter heart valves","volume":"12","author":"Pagnesi","year":"2019","journal-title":"JACC Cardiovasc Interv"},{"key":"B30","doi-asserted-by":"publisher","first-page":"2631","DOI":"10.1016\/j.jcin.2020.07.013","article-title":"Transcatheter aortic valve replacement with balloon-expandable valves: comparison of SAPIEN 3 ultra versus SAPIEN 3","volume":"13","author":"Rheude","year":"2020","journal-title":"JACC Cardiovasc Interv"},{"key":"B31","doi-asserted-by":"publisher","first-page":"1706","DOI":"10.1056\/NEJMoa1816885","article-title":"Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients","volume":"380","author":"Popma","year":"2019","journal-title":"N Engl J Med"},{"key":"B32","doi-asserted-by":"publisher","first-page":"1695","DOI":"10.1056\/NEJMoa1814052","article-title":"Transcatheter aortic-valve replacement with a balloon-expandable valve in low-risk patients","volume":"380","author":"Mack","year":"2019","journal-title":"N Engl J Med"},{"key":"B33","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1016\/j.jacc.2020.12.052","article-title":"Outcomes 2 years after transcatheter aortic valve replacement in patients at low surgical risk","volume":"77","author":"Leon","year":"2021","journal-title":"J Am Coll Cardiol"},{"key":"B34","doi-asserted-by":"publisher","first-page":"1330","DOI":"10.1161\/CIRCRESAHA.120.317978","article-title":"Genetic and developmental contributors to aortic stenosis","volume":"128","author":"Dutta","year":"2021","journal-title":"Circ Res"},{"key":"B35","doi-asserted-by":"publisher","first-page":"e75","DOI":"10.1161\/CIRCEP.113.000956","article-title":"Editor\u2019s perspective: the interatrial septum","volume":"6","author":"Asirvatham","year":"2013","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"B36","doi-asserted-by":"publisher","first-page":"81","DOI":"10.15420\/AER.2015.04.02.81","article-title":"Mechanisms of heart block after transcatheter aortic valve replacement\u2014cardiac anatomy, clinical predictors and mechanical factors that contribute to permanent pacemaker implantation","volume":"4","author":"Lee","year":"2015","journal-title":"Arrhythm Electrophysiol Rev"},{"key":"B37","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1080\/17434440.2019.1624161","article-title":"How does new-onset left bundle branch block affect the outcomes of transcatheter aortic valve repair?","volume":"16","author":"Muntan\u00e9-Carol","year":"2019","journal-title":"Expert Rev Med Devices"},{"key":"B38","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1161\/CIRCINTERVENTIONS.108.780858","article-title":"Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve","volume":"1","author":"Piazza","year":"2008","journal-title":"Circ Cardiovasc Interv"},{"key":"B39","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1080\/17434440.2017.1282819","article-title":"Pathophysiology, incidence and predictors of conduction disturbances during transcatheter aortic valve implantation","volume":"14","author":"Barbanti","year":"2017","journal-title":"Expert Rev Med Devices"},{"key":"B40","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ijcard.2014.04.003","article-title":"Visualizing anatomical evidences on atrioventricular conduction system for TAVI","volume":"174","author":"Kawashima","year":"2014","journal-title":"Int J Cardiol"},{"key":"B41","doi-asserted-by":"publisher","first-page":"452","DOI":"10.21037\/acs-2020-av-23","article-title":"The incidence and impact of cardiac conduction disturbances after transcatheter aortic valve replacement","volume":"9","author":"Chen","year":"2020","journal-title":"Ann Cardiothorac Surg"},{"key":"B42","doi-asserted-by":"publisher","first-page":"90","DOI":"10.31083\/j.rcm2303090","article-title":"Current opinions on new-onset left bundle branch block after transcatheter aortic valve replacement and the search for physiological pacing","volume":"23","author":"Zhang","year":"2022","journal-title":"Rev Cardiovasc Med"},{"key":"B43","doi-asserted-by":"publisher","first-page":"e29","DOI":"10.1161\/CIRCULATIONAHA.109.849281","article-title":"Cause of complete atrioventricular block after percutaneous aortic valve implantation: insights from a necropsy study","volume":"120","author":"Moreno","year":"2009","journal-title":"Circulation"},{"key":"B44","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1038\/nrcardio.2012.58","article-title":"New conduction abnormalities after TAVI\u2013frequency and causes","volume":"9","author":"van der Boon","year":"2012","journal-title":"Nat Rev Cardiol"},{"key":"B45","doi-asserted-by":"publisher","first-page":"2067","DOI":"10.1093\/eurheartj\/ehr110","article-title":"Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve system in patients with aortic stenosis","volume":"32","author":"Nuis","year":"2011","journal-title":"Eur Heart J"},{"key":"B46","doi-asserted-by":"publisher","first-page":"2789","DOI":"10.1016\/j.jacc.2009.12.068","article-title":"Bicuspid aortic valve disease","volume":"55","author":"Siu","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"B47","doi-asserted-by":"publisher","first-page":"2625","DOI":"10.1093\/eurheartj\/ehy244","article-title":"Transcatheter aortic valve implantation: current status and future perspectives","volume":"39","author":"Cahill","year":"2018","journal-title":"Eur Heart J"},{"key":"B48","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1097\/HCO.0000000000000379","article-title":"Latest evidence on transcatheter aortic valve implantation vs. surgical aortic valve replacement for the treatment of aortic stenosis in high and intermediate-risk patients","volume":"32","author":"Praz","year":"2017","journal-title":"Curr Opin Cardiol"},{"key":"B49","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1007\/s00392-017-1093-2","article-title":"Predictors for permanent pacemaker implantation in patients undergoing transfemoral aortic valve implantation with the Edwards Sapien 3 valve","volume":"106","author":"Gonska","year":"2017","journal-title":"Clin Res Cardiol"},{"key":"B50","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/j.ahj.2017.07.011","article-title":"Predictors of permanent pacemaker implantation after transfemoral aortic valve implantation with the Lotus valve","volume":"192","author":"Ke\u00dfler","year":"2017","journal-title":"Am Heart J"},{"key":"B51","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1007\/s00392-023-02160-0","article-title":"Prediction of conduction disturbances in patients undergoing transcatheter aortic valve replacement","volume":"112","author":"Pavlicek","year":"2023","journal-title":"Clin Res Cardiol"},{"key":"B52","doi-asserted-by":"publisher","first-page":"743257","DOI":"10.3389\/fcvm.2021.743257","article-title":"Predictors of permanent pacemaker implantation in patients after transcatheter aortic valve replacement in a Chinese population","volume":"8","author":"Zhang","year":"2021","journal-title":"Front Cardiovasc Med"},{"key":"B53","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.1016\/j.jcin.2018.06.014","article-title":"Predictors of advanced conduction disturbances requiring a late (\u226548\u2005H) permanent pacemaker following transcatheter aortic valve replacement","volume":"11","author":"Mangieri","year":"2018","journal-title":"JACC Cardiovasc Interv"},{"key":"B54","doi-asserted-by":"publisher","first-page":"846","DOI":"10.1111\/pace.13695","article-title":"Cardiac conduction abnormalities associated with pacemaker implantation after transcatheter aortic valve replacement","volume":"42","author":"Cresse","year":"2019","journal-title":"Pacing Clin Electrophysiol"},{"key":"B55","doi-asserted-by":"publisher","first-page":"2723","DOI":"10.1016\/j.jcin.2021.09.003","article-title":"Delayed total atrioventricular block after transcatheter aortic valve replacement assessed by implantable loop recorders","volume":"14","author":"Reiter","year":"2021","journal-title":"JACC Cardiovasc Interv"},{"key":"B56","doi-asserted-by":"publisher","first-page":"euad066","DOI":"10.1093\/europace\/euad066","article-title":"The R-wave amplitude in V1 on baseline electrocardiogram correlates with the occurrence of high-degree atrioventricular block following left bundle branch block after transcatheter aortic valve replacement","volume":"25","author":"Yagel","year":"2023","journal-title":"Europace"},{"key":"B57","doi-asserted-by":"publisher","first-page":"1385","DOI":"10.1093\/ehjci\/jev343","article-title":"Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation","volume":"17","author":"Fujita","year":"2016","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"B58","doi-asserted-by":"publisher","first-page":"2200","DOI":"10.1016\/j.jcin.2016.08.034","article-title":"Predictors of permanent pacemaker implantation after transcatheter aortic valve replacement with the SAPIEN 3","volume":"9","author":"Mauri","year":"2016","journal-title":"JACC Cardiovasc Interv"},{"key":"B59","doi-asserted-by":"publisher","first-page":"1139","DOI":"10.1016\/j.jcmg.2016.11.020","article-title":"A highly predictive risk model for pacemaker implantation after TAVR","volume":"10","author":"Maeno","year":"2017","journal-title":"JACC Cardiovasc Imaging"},{"key":"B60","doi-asserted-by":"publisher","first-page":"4835","DOI":"10.3390\/jcm12144835","article-title":"Predictors of conduction disturbances requiring new permanent pacemaker implantation following transcatheter aortic valve implantation using the evolut series","volume":"12","author":"Abdelshafy","year":"2023","journal-title":"J Clin Med"},{"key":"B61","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1016\/j.jcct.2022.07.003","article-title":"Impact of membranous septum length on pacemaker need with different transcatheter aortic valve replacement systems: the INTERSECT registry","volume":"16","author":"Hokken","year":"2022","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"B62","doi-asserted-by":"publisher","first-page":"1194","DOI":"10.1093\/eurheartj\/ehw594","article-title":"Concomitant mitral annular calcification and severe aortic stenosis: prevalence, characteristics and outcome following transcatheter aortic valve replacement","volume":"38","author":"Abramowitz","year":"2017","journal-title":"Eur Heart J"},{"key":"B63","doi-asserted-by":"publisher","first-page":"1055","DOI":"10.1007\/s00380-021-01999-5","article-title":"Impact of tapered-shape left ventricular outflow tract on pacemaker rate after transcatheter aortic valve replacement","volume":"37","author":"Ishizu","year":"2022","journal-title":"Heart Vessels"},{"key":"B64","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1186\/s40001-023-01237-w","article-title":"A prediction model for permanent pacemaker implantation after transcatheter aortic valve replacement","volume":"28","author":"Qi","year":"2023","journal-title":"Eur J Med Res"},{"key":"B65","doi-asserted-by":"publisher","first-page":"E897","DOI":"10.1002\/ccd.29805","article-title":"Computed tomography derived predictors of permanent pacemaker implantation after transcatheter aortic valve replacement: a meta-analysis","volume":"98","author":"Maier","year":"2021","journal-title":"Catheter Cardiovasc Interv"},{"key":"B66","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1016\/j.jcct.2017.08.003","article-title":"Association between implantation depth assessed by computed tomography and new-onset conduction disturbances after transcatheter aortic valve implantation","volume":"11","author":"Almeida","year":"2017","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"B67","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.jcin.2014.07.022","article-title":"Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve replacement: the PARTNER (placement of AoRtic TraNscathetER valves) trial and registry","volume":"8","author":"Nazif","year":"2015","journal-title":"JACC Cardiovasc Interv"},{"key":"B68","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1186\/s12872-022-02576-y","article-title":"Preprocedural and procedural variables that predict new-onset conduction disturbances after transcatheter aortic valve replacement","volume":"22","author":"Boonyakiatwattana","year":"2022","journal-title":"BMC Cardiovasc Disord"},{"key":"B69","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1016\/j.ijcard.2022.05.014","article-title":"Development of atrioventricular and intraventricular conduction disturbances in patients undergoing transcatheter aortic valve replacement with new generation self-expanding valves: a real world multicenter analysis","volume":"362","author":"Castro-Mej\u00eda","year":"2022","journal-title":"Int J Cardiol"},{"key":"B70","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.jtcvs.2020.07.072","article-title":"Membranous septum length predicts conduction disturbances following transcatheter aortic valve replacement","volume":"164","author":"Chen","year":"2022","journal-title":"J Thorac Cardiovasc Surg"},{"key":"B71","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.ijcard.2022.03.043","article-title":"Multicenter comparison of latest-generation balloon-expandable versus self-expanding transcatheter heart valves: ultra versus evolut","volume":"357","author":"Rheude","year":"2022","journal-title":"Int J Cardiol"},{"key":"B72","doi-asserted-by":"publisher","first-page":"2218","DOI":"10.1093\/eurheartj\/ehz227","article-title":"New-onset left bundle branch block after transcatheter aortic valve replacement is associated with adverse long-term clinical outcomes in intermediate-risk patients: an analysis from the PARTNER II trial","volume":"40","author":"Nazif","year":"2019","journal-title":"Eur Heart J"},{"key":"B73","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1080\/00015385.2020.1713520","article-title":"A single-centre cohort and short-term follow-up of patients who developed persistent new onset left bundle branch block after transcatheter aortic valve replacement","volume":"75","author":"Akdemir","year":"2020","journal-title":"Acta Cardiol"},{"key":"B74","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.1016\/j.jcin.2019.03.025","article-title":"Long-term outcomes in patients with new-onset persistent left bundle branch block following TAVR","volume":"12","author":"Chamandi","year":"2019","journal-title":"JACC Cardiovasc Interv"},{"key":"B75","doi-asserted-by":"publisher","first-page":"1599","DOI":"10.1093\/eurheartj\/eht376","article-title":"Clinical implications of new-onset left bundle branch block after transcatheter aortic valve replacement: analysis of the PARTNER experience","volume":"35","author":"Nazif","year":"2014","journal-title":"Eur Heart J"},{"key":"B76","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1016\/j.jcin.2017.10.032","article-title":"Long-term outcomes in patients with new permanent pacemaker implantation following transcatheter aortic valve replacement","volume":"11","author":"Chamandi","year":"2018","journal-title":"JACC Cardiovasc Interv"},{"key":"B77","doi-asserted-by":"publisher","first-page":"1508","DOI":"10.1016\/j.hrthm.2022.04.030","article-title":"Pacing burden and clinical outcomes after transcatheter aortic valve replacement-A real-world registry report","volume":"19","author":"Natanzon","year":"2022","journal-title":"Heart Rhythm"},{"key":"B78","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1016\/j.acvd.2022.04.005","article-title":"Long-term outcomes of new-onset conduction abnormalities following transcatheter aortic valve implantation","volume":"115","author":"Tomii","year":"2022","journal-title":"Arch Cardiovasc Dis"},{"key":"B79","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1016\/j.jacc.2011.09.061","article-title":"Incidence, predictive factors, and prognostic value of new-onset atrial fibrillation following transcatheter aortic valve implantation","volume":"59","author":"Amat-Santos","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"B80","doi-asserted-by":"publisher","first-page":"e026239","DOI":"10.1161\/JAHA.122.026239","article-title":"Value of periprocedural electrophysiology testing during transcatheter aortic valve replacement for risk stratification of patients with new-onset left bundle-branch block","volume":"11","author":"Badertscher","year":"2022","journal-title":"J Am Heart Assoc"},{"key":"B81","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1016\/j.jcin.2018.04.016","article-title":"Arrhythmic burden as determined by ambulatory continuous cardiac monitoring in patients with new-onset persistent left bundle branch block following transcatheter aortic valve replacement: the MARE study","volume":"11","author":"Rod\u00e9s-Cabau","year":"2018","journal-title":"JACC Cardiovasc Interv"},{"key":"B82","doi-asserted-by":"publisher","first-page":"5390338","DOI":"10.1155\/2023\/5390338","article-title":"Impact of new-onset conduction disturbances following transcatheter aortic valve replacement on outcomes: a single-center study","volume":"2023","author":"See","year":"2023","journal-title":"J Interv Cardiol"},{"key":"B83","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.ijcard.2016.11.063","article-title":"Predictive factor and clinical consequence of left bundle-branch block after a transcatheter aortic valve implantation","volume":"227","author":"Nishiyama","year":"2017","journal-title":"Int J Cardiol"},{"key":"B84","doi-asserted-by":"publisher","first-page":"E144","DOI":"10.1002\/ccd.25765","article-title":"Trends in the occurrence of new conduction abnormalities after transcatheter aortic valve implantation","volume":"85","author":"van der Boon","year":"2015","journal-title":"Catheter Cardiovasc Interv"},{"key":"B85","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1016\/j.tcm.2018.10.012","article-title":"Mechanism of harm from left bundle branch block","volume":"29","author":"Smiseth","year":"2019","journal-title":"Trends Cardiovasc Med"},{"key":"B86","doi-asserted-by":"publisher","first-page":"e003635","DOI":"10.1161\/CIRCINTERVENTIONS.115.003635","article-title":"Impact of new-onset left bundle branch block and periprocedural permanent pacemaker implantation on clinical outcomes in patients undergoing transcatheter aortic valve replacement: a systematic review and meta-analysis","volume":"9","author":"Regueiro","year":"2016","journal-title":"Circ Cardiovasc Interv"},{"key":"B87","doi-asserted-by":"publisher","first-page":"893878","DOI":"10.3389\/fcvm.2022.893878","article-title":"Impact of new-onset persistent left bundle branch block on reverse cardiac remodeling and clinical outcomes after transcatheter aortic valve replacement","volume":"9","author":"Kim","year":"2022","journal-title":"Front Cardiovasc Med"},{"key":"B88","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1186\/s12968-018-0457-8","article-title":"Effect of isolated left bundle-branch block on biventricular volumes and ejection fraction: a cardiovascular magnetic resonance assessment","volume":"20","author":"Akhtari","year":"2018","journal-title":"J Cardiovasc Magn Reson"},{"key":"B89","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.ejheart.2006.04.011","article-title":"Left bundle branch block as a risk factor for progression to heart failure","volume":"9","author":"Zannad","year":"2007","journal-title":"Eur J Heart Fail"},{"key":"B90","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.1093\/europace\/euw174","article-title":"Severe conduction defects requiring permanent pacemaker implantation in patients with a new-onset left bundle branch block after transcatheter aortic valve implantation","volume":"19","author":"Nijenhuis","year":"2017","journal-title":"Europace"},{"key":"B91","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1016\/j.amjcard.2022.06.014","article-title":"Effects of left bundle branch block and pacemaker implantation on left ventricular systolic function after transcatheter aortic valve implantation","volume":"179","author":"Dolci","year":"2022","journal-title":"Am J Cardiol"},{"key":"B92","doi-asserted-by":"publisher","first-page":"540","DOI":"10.1016\/j.jcin.2012.03.004","article-title":"Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings","volume":"5","author":"Bagur","year":"2012","journal-title":"JACC Cardiovasc Interv"},{"key":"B93","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1161\/CIRCINTERVENTIONS.111.961649","article-title":"Atrioventricular conduction disturbance characterization in transcatheter aortic valve implantation with the CoreValve prosthesis","volume":"4","author":"Rub\u00edn","year":"2011","journal-title":"Circ Cardiovasc Interv"},{"key":"B94","doi-asserted-by":"publisher","first-page":"e51","DOI":"10.1016\/j.jacc.2018.10.044","article-title":"2018 ACC\/AHA\/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay: a report of the American college of cardiology\/American heart association task force on clinical practice guidelines and the heart rhythm society","volume":"74","author":"Kusumoto","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"B95","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.hrthm.2020.10.013","article-title":"Effect of pacemaker implantation after transcatheter aortic valve replacement on long- and mid-term mortality","volume":"18","author":"Hochstadt","year":"2021","journal-title":"Heart Rhythm"},{"key":"B96","doi-asserted-by":"publisher","first-page":"2281","DOI":"10.1093\/eurheartj\/eht150","article-title":"2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European society of cardiology (ESC). Developed in collaboration with the European heart rhythm association (EHRA)","volume":"34","author":"Brignole","year":"2013","journal-title":"Eur Heart J"},{"key":"B97","doi-asserted-by":"publisher","first-page":"3427","DOI":"10.1093\/eurheartj\/ehab364","article-title":"2021 ESC guidelines on cardiac pacing and cardiac resynchronization therapy","volume":"42","author":"Glikson","year":"2021","journal-title":"Eur Heart J"},{"key":"B98","doi-asserted-by":"publisher","first-page":"e6","DOI":"10.1016\/j.jacc.2012.11.007","article-title":"2012 ACCF\/AHA\/HRS focused update incorporated into the ACCF\/AHA\/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American college of cardiology foundation\/American heart association task force on practice guidelines and the heart rhythm society","volume":"61","author":"Epstein","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"B99","doi-asserted-by":"publisher","first-page":"e005046","DOI":"10.1161\/CIRCINTERVENTIONS.117.005046","article-title":"Clinical and echocardiographic outcomes following permanent pacemaker implantation after transcatheter aortic valve replacement: meta-analysis and meta-regression","volume":"10","author":"Mohananey","year":"2017","journal-title":"Circ Cardiovasc Interv"},{"key":"B100","doi-asserted-by":"publisher","first-page":"911234","DOI":"10.3389\/fcvm.2022.911234","article-title":"Mid- to long-term clinical and echocardiographic effects of post-procedural permanent pacemaker implantation after transcatheter aortic valve replacement: a systematic review and meta-analysis","volume":"9","author":"Xu","year":"2022","journal-title":"Front Cardiovasc Med"},{"key":"B101","doi-asserted-by":"publisher","first-page":"1086","DOI":"10.1016\/j.jacc.2019.07.014","article-title":"Management of conduction disturbances associated with transcatheter aortic valve replacement: JACC scientific expert panel","volume":"74","author":"Rod\u00e9s-Cabau","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"B102","doi-asserted-by":"publisher","first-page":"743","DOI":"10.1002\/ccd.30788","article-title":"Prognostic impact of new permanent pacemaker implantation following transcatheter aortic valve replacement","volume":"102","author":"Zheng","year":"2023","journal-title":"Catheter Cardiovasc Interv"},{"key":"B103","doi-asserted-by":"publisher","first-page":"1081","DOI":"10.1016\/j.jcin.2023.02.003","article-title":"Impact of right ventricular pacing in patients with TAVR undergoing permanent pacemaker implantation","volume":"16","author":"Bruno","year":"2023","journal-title":"JACC Cardiovasc Interv"},{"key":"B104","doi-asserted-by":"publisher","first-page":"764","DOI":"10.1016\/j.jacc.2009.06.006","article-title":"The effects of right ventricular apical pacing on ventricular function and dyssynchrony implications for therapy","volume":"54","author":"Tops","year":"2009","journal-title":"J Am Coll Cardiol"},{"key":"B105","doi-asserted-by":"publisher","first-page":"2027","DOI":"10.1016\/j.hrthm.2021.06.1175","article-title":"Outcomes associated with pacemaker implantation following transcatheter aortic valve replacement: a nationwide cohort study","volume":"18","author":"Clementy","year":"2021","journal-title":"Heart Rhythm"},{"key":"B106","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1016\/j.jelectrocard.2015.07.002","article-title":"The effects of right ventricular apical pacing with transvenous pacemaker and implantable cardioverter defibrillator on mitral and tricuspid regurgitation","volume":"48","author":"Fanari","year":"2015","journal-title":"J Electrocardiol"},{"key":"B107","doi-asserted-by":"publisher","first-page":"1171","DOI":"10.1080\/13696998.2019.1652186","article-title":"Pacemaker complications and costs: a nationwide economic study","volume":"22","author":"Cl\u00e9menty","year":"2019","journal-title":"J Med Econ"},{"key":"B108","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1016\/j.jcin.2016.01.037","article-title":"Prevalence and impact of atrial fibrillation in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement: an analysis from the SOURCE XT prospective multicenter registry","volume":"9","author":"Tarantini","year":"2016","journal-title":"JACC Cardiovasc Interv"},{"key":"B109","doi-asserted-by":"publisher","first-page":"2119","DOI":"10.1016\/j.jcin.2019.06.019","article-title":"Impact of pre-existing and new-onset atrial fibrillation on outcomes after transcatheter aortic valve replacement","volume":"12","author":"Mentias","year":"2019","journal-title":"JACC Cardiovasc Interv"},{"key":"B110","doi-asserted-by":"publisher","first-page":"1746","DOI":"10.1016\/j.jcin.2018.05.042","article-title":"Incidence, management, and associated clinical outcomes of new-onset atrial fibrillation following transcatheter aortic valve replacement: an analysis from the STS\/ACC TVT registry","volume":"11","author":"Vora","year":"2018","journal-title":"JACC Cardiovasc Interv"},{"key":"B111","doi-asserted-by":"publisher","first-page":"1565","DOI":"10.1016\/j.jcin.2021.05.026","article-title":"Postoperative atrial fibrillation or flutter following transcatheter or surgical aortic valve replacement: pARTNER 3 trial","volume":"14","author":"Shahim","year":"2021","journal-title":"JACC Cardiovasc Interv"},{"key":"B112","doi-asserted-by":"publisher","first-page":"1510","DOI":"10.1016\/j.jacc.2013.11.046","article-title":"New-onset atrial fibrillation after aortic valve replacement: comparison of transfemoral, transapical, transaortic, and surgical approaches","volume":"63","author":"Tanawuttiwat","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"B113","doi-asserted-by":"publisher","first-page":"2083","DOI":"10.1093\/eurheartj\/ehi350","article-title":"Inflammation in the genesis and perpetuation of atrial fibrillation","volume":"26","author":"Engelmann","year":"2005","journal-title":"Eur Heart J"},{"key":"B114","doi-asserted-by":"publisher","first-page":"1894","DOI":"10.1161\/01.CIR.100.18.1894","article-title":"Electrical remodeling of the atria following loss of atrioventricular synchrony: a long-term study in humans","volume":"100","author":"Sparks","year":"1999","journal-title":"Circulation"},{"key":"B115","doi-asserted-by":"publisher","first-page":"e199","DOI":"10.1161\/CIR.0000000000000041","article-title":"2014 AHA\/ACC\/HRS guideline for the management of patients with atrial fibrillation: a report of the American college of cardiology\/American heart association task force on practice guidelines and the heart rhythm society","volume":"130","author":"January","year":"2014","journal-title":"Circulation"},{"key":"B116","doi-asserted-by":"publisher","first-page":"2124","DOI":"10.1111\/pace.14353","article-title":"Outcomes of non-left bundle branch block conduction abnormalities after transcatheter aortic valve replacement","volume":"44","author":"Wang","year":"2021","journal-title":"Pacing Clin Electrophysiol"},{"key":"B117","doi-asserted-by":"publisher","first-page":"1218","DOI":"10.1111\/jce.14469","article-title":"New-onset intrinsic and paced QRS morphology of right bundle branch block pattern after atrioventricular nodal ablation: longitudinal dissociation or anatomical bifurcation?","volume":"31","author":"Wu","year":"2020","journal-title":"J Cardiovasc Electrophysiol"},{"key":"B118","doi-asserted-by":"publisher","first-page":"e180088","DOI":"10.1001\/jamanetworkopen.2018.0088","article-title":"Association of clinical and economic outcomes with permanent pacemaker implantation after transcatheter aortic valve replacement","volume":"1","author":"Aljabbary","year":"2018","journal-title":"JAMA Netw Open"},{"key":"B119","doi-asserted-by":"publisher","first-page":"1269","DOI":"10.1016\/j.jcin.2016.03.024","article-title":"The electrocardiogram after transcatheter aortic valve replacement determines the risk for post-procedural high-degree AV block and the need for telemetry monitoring","volume":"9","author":"Toggweiler","year":"2016","journal-title":"JACC Cardiovasc Interv"},{"key":"B120","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.1016\/j.jcin.2016.05.004","article-title":"Electrocardiographic monitoring following transcatheter aortic valve replacement: do we need to and for how long?","volume":"9","author":"Urena","year":"2016","journal-title":"JACC Cardiovasc Interv"},{"key":"B121","doi-asserted-by":"publisher","first-page":"1179","DOI":"10.1093\/europace\/euac027","article-title":"Management of conduction disorders after transcatheter aortic valve implantation: results of the EHRA survey","volume":"24","author":"Badertscher","year":"2022","journal-title":"Europace"},{"key":"B122","doi-asserted-by":"publisher","first-page":"1981","DOI":"10.1093\/europace\/euy074","article-title":"Conduction dynamics after transcatheter aortic valve implantation and implications for permanent pacemaker implantation and early discharge: the CONDUCT-study","volume":"20","author":"van Gils","year":"2018","journal-title":"Europace"},{"key":"B123","doi-asserted-by":"publisher","first-page":"1441","DOI":"10.1093\/europace\/euad025","article-title":"Clinical impact of right ventricular pacing burden in patients with post-transcatheter aortic valve replacement permanent pacemaker implantation","volume":"25","author":"Tsushima","year":"2023","journal-title":"Europace"},{"key":"B124","doi-asserted-by":"publisher","first-page":"2004","DOI":"10.1016\/j.jcin.2023.05.020","article-title":"Incidence, predictors, and prognostic impact of new permanent pacemaker implantation after TAVR with self-expanding valves","volume":"16","author":"Pagnesi","year":"2023","journal-title":"JACC Cardiovasc Interv"},{"key":"B125","doi-asserted-by":"publisher","first-page":"2932","DOI":"10.1161\/01.CIR.0000072769.17295.B1","article-title":"Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction","volume":"107","author":"Sweeney","year":"2003","journal-title":"Circulation"},{"key":"B126","doi-asserted-by":"publisher","first-page":"2407","DOI":"10.1161\/CIRCULATIONAHA.112.000112","article-title":"Cardiac resynchronization therapy: state-of-the-art of current applications, guidelines, ongoing trials, and areas of controversy","volume":"128","author":"Prinzen","year":"2013","journal-title":"Circulation"},{"key":"B127","doi-asserted-by":"publisher","first-page":"3099","DOI":"10.1016\/j.jacc.2017.05.005","article-title":"The continued search for physiological pacing: where are we now?","volume":"69","author":"Vijayaraman","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"B128","doi-asserted-by":"publisher","first-page":"772548","DOI":"10.3389\/fcvm.2021.772548","article-title":"Conduction system pacing for post transcatheter aortic valve replacement patients: comparison with right ventricular pacing","volume":"8","author":"Niu","year":"2021","journal-title":"Front Cardiovasc Med"},{"key":"B129","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1111\/jce.14371","article-title":"Feasibility of his-bundle pacing in patients with conduction disorders following transcatheter aortic valve replacement","volume":"31","author":"De Pooter","year":"2020","journal-title":"J Cardiovasc Electrophysiol"},{"key":"B130","first-page":"300","article-title":"Comparison of TransFemoral transcatheter aortic valve replacement performed with a minimally invasive simplified technique: \u201cFAST\u201d versus a standard approach","volume":"31","author":"Lef\u00e8vre","year":"2019","journal-title":"J Invasive Cardiol"},{"key":"B131","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.3390\/jcm9041017","article-title":"Direct rapid left ventricular wire pacing during balloon aortic valvuloplasty","volume":"9","author":"Kleczynski","year":"2020","journal-title":"J Clin Med"},{"key":"B132","doi-asserted-by":"publisher","first-page":"100213","DOI":"10.1016\/j.shj.2023.100213","article-title":"Best practices in left ventricular pacing for transcatheter aortic valve replacement","volume":"7","author":"Blusztein","year":"2023","journal-title":"Struct Heart"},{"key":"B133","doi-asserted-by":"publisher","first-page":"e014446","DOI":"10.1161\/JAHA.119.014446","article-title":"Electrophysiology testing to stratify patients with left bundle branch block after transcatheter aortic valve implantation","volume":"9","author":"Knecht","year":"2020","journal-title":"J Am Heart Assoc"},{"key":"B134","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1016\/j.hrthm.2014.10.023","article-title":"Electrocardiographic and electrophysiological predictors of atrioventricular block after transcatheter aortic valve replacement","volume":"12","author":"Rivard","year":"2015","journal-title":"Heart Rhythm"},{"key":"B135","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1016\/j.hrthm.2023.01.013","article-title":"Incidence and management of atrioventricular conduction disorders in new-onset left bundle branch block after TAVI: a prospective multicenter study","volume":"20","author":"Massoulli\u00e9","year":"2023","journal-title":"Heart Rhythm"},{"key":"B136","doi-asserted-by":"publisher","first-page":"2391","DOI":"10.1016\/j.jacc.2020.08.050","article-title":"2020 ACC expert consensus decision pathway on management of conduction disturbances in patients undergoing transcatheter aortic valve replacement: a report of the American college of cardiology solution set oversight committee","volume":"76","author":"Lilly","year":"2020","journal-title":"J Am Coll Cardiol"},{"key":"B137","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1007\/s00392-022-02150-8","article-title":"Reduction of permanent pacemaker implantation by using the cusp overlap technique in transcatheter aortic valve replacement: a meta-analysis","volume":"112","author":"Rawish","year":"2023","journal-title":"Clin Res Cardiol"},{"key":"B138","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/j.jcin.2021.10.002","article-title":"Permanent pacemaker reduction using cusp-overlapping projection in TAVR: a propensity score analysis","volume":"15","author":"Pascual","year":"2022","journal-title":"JACC Cardiovasc Interv"},{"key":"B139","doi-asserted-by":"publisher","first-page":"1269833","DOI":"10.3389\/fcvm.2023.1269833","article-title":"Cusp-overlap view reduces conduction disturbances and permanent pacemaker implantation after transcatheter aortic valve replacement even with balloon-expandable and mechanically-expandable heart valves","volume":"10","author":"Stephan","year":"2023","journal-title":"Front Cardiovasc Med"},{"key":"B140","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1016\/j.jcin.2021.12.006","article-title":"Cusp-overlapping projections in TAVR: where the left meets the right","volume":"15","author":"Barth\u00e9l\u00e9my","year":"2022","journal-title":"JACC Cardiovasc Interv"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2024.1370244\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,8]],"date-time":"2024-04-08T05:00:04Z","timestamp":1712552404000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2024.1370244\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,8]]},"references-count":140,"alternative-id":["10.3389\/fcvm.2024.1370244"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2024.1370244","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,8]]},"article-number":"1370244"}}