{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T06:28:22Z","timestamp":1761805702642,"version":"build-2065373602"},"reference-count":25,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T00:00:00Z","timestamp":1761782400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:p>Acute pulmonary embolism (APE), a critical complication following permanent pacemaker implantation, presents profound therapeutic challenges when occurring during the early postoperative phase. We report a 73-year-old female who developed high-risk APE with cardiogenic shock 47\u2005h after dual-chamber pacemaker implantation via the right subclavian vein. The immobilization of the affected upper limb and bed rest, along with endothelial injury during the implantation process, can trigger an inflammatory response and activate the coagulation cascade, ultimately leading to a pro-coagulant state, which may subsequently induce deep vein thrombosis in the lower extremities and subsequent bilateral pulmonary embolism. Following the 2019 ESC guidelines for managing high-risk APE, prompt intravenous thrombolysis with alteplase (50\u2005mg) stabilized hemodynamics. However, this intervention caused pacemaker pocket hemorrhage. Strategic intermittent elastic compression bandaging mitigated hematoma progression without compromising wound healing. Anticoagulation with warfarin (INR 2\u20133) and serial imaging confirmed resolution of thromboembolic burden and right atrial remodeling. This case underscores the delicate balance between life-saving reperfusion and device-related complications in pacemaker recipients, advocating for tailored hemostatic strategies in high-risk cohorts.<\/jats:p>","DOI":"10.3389\/fcvm.2025.1587204","type":"journal-article","created":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T06:23:27Z","timestamp":1761805407000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Acute pulmonary embolism following dual-chamber pacemaker implantation: a case report"],"prefix":"10.3389","volume":"12","author":[{"given":"Zhizhou","family":"Song","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanhua","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanan","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lijuan","family":"Hao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ying","family":"Ma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qi","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuehong","family":"Huo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2025,10,30]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1803","DOI":"10.1055\/s-0030-1263323","article-title":"Acute pulmonary embolism","volume":"135","author":"Braun","year":"2010","journal-title":"Dtsch Med Wochenschr"},{"key":"B2","doi-asserted-by":"publisher","first-page":"780","DOI":"10.1183\/13993003.00024-2016","article-title":"Acute pulmonary embolism: mortality prediction by the 2014 European society of cardiology risk stratification model","volume":"48","author":"Becattini","year":"2016","journal-title":"Eur Respir J"},{"key":"B3","doi-asserted-by":"publisher","first-page":"698336","DOI":"10.3389\/fcvm.2021.698336","article-title":"Upper extremity deep vein thrombosis and asymptomatic vein occlusion in patients with transvenous leads: a systematic review and meta-analysis","volume":"8","author":"Duijzer","year":"2021","journal-title":"Front Cardiovasc Med"},{"key":"B4","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1515\/rjim-2017-0018","article-title":"Upper extremity deep venous thrombosis and stenosis after implantation of pacemakers and defibrillators; a prospective study","volume":"55","author":"Safi","year":"2017","journal-title":"Rom J Intern Med"},{"key":"B5","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1159\/000007018","article-title":"Transvenous pacing lead-induced thrombosis: a series of cases with a review of the literature","volume":"93","author":"Barakat","year":"2000","journal-title":"Cardiology"},{"key":"B6","doi-asserted-by":"publisher","first-page":"e0272305","DOI":"10.1371\/journal.pone.0272305","article-title":"Sex differences in rates of permanent pacemaker implantation and in-hospital complications: a statewide cohort study of over 7 million persons from 2009 to 2018","volume":"17","author":"Vijayarajan","year":"2022","journal-title":"PLoS One"},{"key":"B7","doi-asserted-by":"publisher","first-page":"1194","DOI":"10.1111\/j.1540-8159.2012.03467.x","article-title":"Permanent pacemaker-related upper extremity deep vein thrombosis: a series of 20 cases","volume":"35","author":"Mandal","year":"2012","journal-title":"Pacing Clin Electrophysiol"},{"key":"B8","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1111\/pace.13915","article-title":"Upper extremity deep venous thrombosis and pulmonary embolism after transvenous lead replacement or upgrade procedures","volume":"43","author":"Albertini","year":"2020","journal-title":"Pacing Clin Electrophysiol"},{"key":"B9","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1007\/s11936-018-0664-5","article-title":"Venous obstruction in cardiac rhythm device therapy","volume":"20","author":"Donnelly","year":"2018","journal-title":"Curr Treat Options Cardiovasc Med"},{"key":"B10","doi-asserted-by":"publisher","first-page":"e21737","DOI":"10.7759\/cureus.21737","article-title":"Post-cardiac injury syndrome following permanent dual-chamber pacemaker implantation","volume":"14","author":"Patel","year":"2022","journal-title":"Cur\u0113us"},{"key":"B11","doi-asserted-by":"publisher","first-page":"1219","DOI":"10.1007\/s40520-018-1088-5","article-title":"The influence of age on the psychological profile of patients with cardiac implantable electronic devices: results from the Italian population in a multicenter study conducted by the European heart rhythm association","volume":"31","author":"Fumagalli","year":"2019","journal-title":"Aging Clin Exp Res"},{"key":"B12","doi-asserted-by":"publisher","first-page":"1901647","DOI":"10.1183\/13993003.01647-2019","article-title":"2019 ESC guidelines for the diagnosis and management of acute pulmonary embolism developed in collaboration with the European respiratory society (ERS): the task force for the diagnosis and management of acute pulmonary embolism of the European Society of Cardiology (ESC)","volume":"54","author":"Konstantinides","year":"2019","journal-title":"Eur Respir J"},{"key":"B13","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1016\/j.jvsv.2017.12.058","article-title":"Catheter-directed interventions compared with systemic thrombolysis achieve improved ventricular function recovery at a potentially lower complication rate for acute pulmonary embolism","volume":"6","author":"Avgerinos","year":"2018","journal-title":"J Vasc Surg Venous Lymphat Disord"},{"key":"B14","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1378\/chest.09-0765","article-title":"Efficacy and safety of low dose recombinant tissue-type plasminogen activator for the treatment of acute pulmonary thromboembolism: a randomized, multicenter, controlled trial","volume":"137","author":"Wang","year":"2010","journal-title":"Chest"},{"key":"B15","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1016\/j.hrtlng.2019.09.009","article-title":"The relationship between pocket hematoma and risk of wound infection among patients with a cardiovascular implantable electronic device: an integrative review","volume":"49","author":"Song","year":"2020","journal-title":"Heart Lung"},{"key":"B16","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1093\/europace\/euab263","article-title":"EHRA expert consensus statement and practical guide on optimal implantation technique for conventional pacemakers and implantable cardioverter-defibrillators: endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), and the Latin-American Heart Rhythm Society (LAHRS)\u2014a role for post-operative ultrasound?","volume":"24","author":"Davis","year":"2022","journal-title":"EP Eur"},{"key":"B17","doi-asserted-by":"publisher","first-page":"2493","DOI":"10.1016\/j.jacc.2006.02.049","article-title":"The frequency and incremental cost of major complications among medicare beneficiaries receiving implantable cardioverter-defibrillators","volume":"47","author":"Reynolds","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"B18","doi-asserted-by":"publisher","first-page":"1476","DOI":"10.1111\/pace.13482","article-title":"Interrupted versus uninterrupted novel oral anticoagulant peri-implantation of cardiac device: a single-center randomized prospective pilot trial","volume":"41","author":"Ricciardi","year":"2018","journal-title":"Pacing Clin Electrophysiol"},{"key":"B19","doi-asserted-by":"publisher","first-page":"e004822","DOI":"10.1161\/CIRCEP.116.004822","article-title":"Reimplantation and repeat infection after cardiac-implantable electronic device infections: experience from the MEDIC (multicenter electrophysiologic device infection cohort) database","volume":"10","author":"Boyle","year":"2017","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"B20","doi-asserted-by":"publisher","first-page":"1548","DOI":"10.1093\/europace\/euv075","article-title":"Impact of haematoma after pacemaker and CRT device implantation on hospitalization costs, length of stay, and mortality: a population-based study","volume":"17","author":"Sridhar","year":"2015","journal-title":"Europace"},{"key":"B21","doi-asserted-by":"publisher","first-page":"3427","DOI":"10.1093\/eurheartj\/ehab364","article-title":"2021 ESC guidelines on cardiac pacing and cardiac resynchronization therapy","volume":"42","author":"Glikson","year":"2021","journal-title":"Eur Heart J"},{"key":"B22","doi-asserted-by":"publisher","first-page":"5761","DOI":"10.1016\/j.asjsur.2023.08.133","article-title":"Implantation of micra AV: a leadless atrioventricular synchronous pacemaker","volume":"46","author":"Li","year":"2023","journal-title":"Asian J Surg"},{"key":"B23","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1093\/europace\/euaa367","article-title":"EHRA Expert consensus statement and practical guide on optimal implantation technique for conventional pacemakers and implantable cardioverter-defibrillators: endorsed by the heart rhythm society (HRS), the Asia Pacific heart rhythm society (APHRS), and the Latin-American heart rhythm society (LAHRS)","volume":"23","author":"Burri","year":"2021","journal-title":"Europace"},{"key":"B24","doi-asserted-by":"publisher","first-page":"1800","DOI":"10.1016\/j.hrthm.2018.08.005","article-title":"Updated performance of the Micra transcatheter pacemaker in the real-world setting: a comparison to the investigational study and a transvenous historical control","volume":"15","author":"El-Chami","year":"2018","journal-title":"Heart Rhythm"},{"key":"B25","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1111\/jce.14807","article-title":"Atrio-ventricular synchronous pacing with a single chamber leadless pacemaker: programming and trouble shooting for common clinical scenarios","volume":"32","author":"El-Chami","year":"2021","journal-title":"J Cardiovasc Electrophysiol"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2025.1587204\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T06:23:29Z","timestamp":1761805409000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2025.1587204\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,30]]},"references-count":25,"alternative-id":["10.3389\/fcvm.2025.1587204"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2025.1587204","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,30]]},"article-number":"1587204"}}