{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T18:13:02Z","timestamp":1787163182202,"version":"build-2736575974"},"reference-count":45,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,11,24]],"date-time":"2025-11-24T00:00:00Z","timestamp":1763942400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>This meta-analysis was designed to compare the safety and efficacy of percutaneous endovascular aortic repair (PEVAR) with endovascular aortic repair by cutdown access (CEVAR) in the treatment of TBAD.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>Four databases (PubMed, Embase, Web of Science, and Cochrane Library) were carefully queried for articles comparing PEVAR and CEVAR in patients with TBAD. The search was performed from the foundation of the databases until March 31, 2025.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Totally 24 studies were included in this meta-analysis. The meta-analysis included a group of 28,263 patients diagnosed with TBAD, with 14,534 patients undergoing PEVAR and 13,729 patients undergoing CEVAR. In comparison to CEVAR, PEVAR resulted in a reduced hospital length of stay (MD\u2009=\u2009\u22122.16 days, 95% CI: \u22123.05 to \u22121.27,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.00001), decreased operative time (MD\u2009=\u2009\u221240.87\u2005min, 95% CI: \u221249.72 to \u221232.02,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.00001), shorter postoperative duration (MD\u2009=\u2009\u22121.01 days, 95% CI: \u22121.56 to \u22120.45,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.0004), diminished incidence of groin infection (OR\u2009=\u20090.44, 95% CI: 0.30 to 0.65,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.0001), lower occurrence of heart-related complications (OR\u2009=\u20090.76, 95% CI: 0.59 to 1.00,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.05), and reduced incidence of lymphocele (OR\u2009=\u20090.49, 95% CI: 0.24 to 0.98,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.04), but a higher incidence of surgical suture failure (OR\u2009=\u20092.61, 95% CI: 1.52 to 4.50,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.0005) and pseudoaneurysm (OR\u2009=\u20092.64, 95% CI: 1.09 to 6.41,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.03). No statistically significant differences were observed between the two groups concerning estimated blood loss, ICU admissions, hematoma, acute kidney injury, lower extremity revascularization, ischemic colitis, and deep venous thrombosis.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Compared to CEVAR, PEVAR was associated with a shorter hospital stay, reduced operative time, quicker postoperative recovery, lower rates of groin infections, fewer cardiac complications, and a diminished occurrence of lymphocele; however, it exhibited a higher incidence of pseudoaneurysm and an increased rate of surgical suture failure. PEVAR was a safe and effective method for the treatment of TBAD.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Systematic Review Registration<\/jats:title>\n                    <jats:p>\n                      <jats:ext-link>https:\/\/www.crd.york.ac.uk\/prospero\/display_record.php?ID=CRD420251110307<\/jats:ext-link>\n                      , PROSPERO CRD420251110307.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fcvm.2025.1673817","type":"journal-article","created":{"date-parts":[[2025,11,24]],"date-time":"2025-11-24T06:29:53Z","timestamp":1763965793000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Comparison of percutaneous vs. cutdown access for endovascular aortic repair in the treatment of type B aortic dissection: a meta-analysis"],"prefix":"10.3389","volume":"12","author":[{"given":"Zhongyou","family":"Liang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ziping","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minyao","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lidai","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Binyao","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shan","family":"Yin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huaicheng","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jieru","family":"Quan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weiming","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaolong","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,11,24]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"16","DOI":"10.3390\/jcm13051231","article-title":"Acute aortic syndromes from diagnosis to treatment-a comprehensive review","volume":"13","author":"Banceu","year":"2024","journal-title":"J Clin Med"},{"key":"B2","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1016\/j.jvs.2014.12.038","article-title":"The natural history of medically managed acute type B aortic dissection","volume":"61","author":"Durham","year":"2015","journal-title":"J Vasc Surg"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1169","DOI":"10.5603\/kp.2014.0225","article-title":"2014 Esc guidelines on the diagnosis and treatment of aortic diseases","volume":"72","author":"Erbel","year":"2014","journal-title":"Kardiol Pol"},{"key":"B4","doi-asserted-by":"publisher","first-page":"1360","DOI":"10.1016\/j.athoracsur.2009.02.050","article-title":"Endovascular treatment of type B aortic dissection: the challenge of late success","volume":"87","author":"Alves","year":"2009","journal-title":"Ann Thorac Surg"},{"key":"B5","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1016\/j.ejvs.2011.12.025","article-title":"Unselected percutaneous access with large vessel closure for endovascular aortic surgery: experience and predictors of technical success","volume":"43","author":"Metcalfe","year":"2012","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"B6","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/s0741-5214(02)75454-2","article-title":"Endovascular suture versus cutdown for endovascular aneurysm repair: a prospective randomized pilot study","volume":"38","author":"Torsello","year":"2003","journal-title":"J Vasc Surg"},{"key":"B7","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1016\/j.avsg.2020.06.033","article-title":"Outcomes of open versus percutaneous access for patients enrolled in the great registry","volume":"70","author":"Baxter","year":"2021","journal-title":"Ann Vasc Surg"},{"key":"B8","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1177\/152660289900600209","article-title":"Closure of large percutaneous access sites using the prostar Xl percutaneous vascular surgery device","volume":"6","author":"Haas","year":"1999","journal-title":"J Endovasc Surg"},{"key":"B9","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1177\/152660280701400210","article-title":"Total percutaneous endovascular repair of abdominal aortic aneurysms using perclose proglide closure devices","volume":"14","author":"Dosluoglu","year":"2007","journal-title":"J Endovasc Ther"},{"key":"B10","doi-asserted-by":"publisher","first-page":"8823039","DOI":"10.1155\/2020\/8823039","article-title":"Comparing and correlating outcomes between open and percutaneous access in endovascular aneurysm repair in aortic aneurysms using a retrospective cohort study design","volume":"2020","author":"DeVito","year":"2020","journal-title":"Int J Vasc Med"},{"key":"B11","doi-asserted-by":"publisher","first-page":"1429","DOI":"10.1016\/j.jvs.2018.07.052","article-title":"Randomized multicenter trial on percutaneous versus open access in endovascular aneurysm repair (piero)","volume":"69","author":"Vierhout","year":"2019","journal-title":"J Vasc Surg"},{"key":"B12","doi-asserted-by":"publisher","first-page":"350","DOI":"10.1001\/jama.291.3.350","article-title":"Arterial puncture closing devices compared with standard manual compression after cardiac catheterization. Systematic review and meta-analysis","volume":"291","author":"Koreny","year":"2004","journal-title":"JAMA"},{"key":"B13","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1016\/j.ejvs.2017.03.015","article-title":"Editor\u2019s choice - arteriotomy closure devices in evar, tevar, and tavr: a systematic review and meta-analysis of randomised clinical trials and cohort studies","volume":"54","author":"Vierhout","year":"2017","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"B14","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1177\/17085381211032765","article-title":"Is percutaneous access superior to cutdown access for endovascular abdominal aortic aneurysm repair? A meta-analysis","volume":"30","author":"Bi","year":"2022","journal-title":"Vascular"},{"key":"B15","doi-asserted-by":"publisher","first-page":"848","DOI":"10.1177\/15385744231180663","article-title":"The safety and effectiveness of the prostar Xl closure device compared to open groin cutdown for endovascular aneurysm repair","volume":"57","author":"Hahl","year":"2023","journal-title":"Vasc Endovascular Surg"},{"key":"B16","doi-asserted-by":"publisher","first-page":"E455","DOI":"10.59958\/hsf.6665","article-title":"Percutaneous versus cutdown access for endovascular aortic repair","volume":"26","author":"Altoijry","year":"2023","journal-title":"Heart Surg Forum"},{"key":"B17","article-title":"The Newcastle-Ottawa Scale (Nos) for Assessing the Quality of Nonrandomised Studies in Meta-Analyses","author":"Wells","year":"2000"},{"key":"B18","doi-asserted-by":"publisher","first-page":"d5928","DOI":"10.1136\/bmj.d5928","article-title":"The cochrane collaboration\u2019s tool for assessing risk of bias in randomised trials","volume":"343","author":"Higgins","year":"2011","journal-title":"BMJ (Clin Res Ed)"},{"key":"B19","doi-asserted-by":"publisher","first-page":"616","DOI":"10.1177\/1708538120965310","article-title":"Comparison between percutaneous and surgical femoral access for endovascular aortic repair in patients with type iii aortic dissection (preclose trial)","volume":"29","author":"Sahin","year":"2021","journal-title":"Vascular"},{"key":"B20","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.avsg.2017.02.004","article-title":"Safety and effectiveness of a \u201cpercutaneous-first\u201d approach to endovascular aortic aneurysm repair","volume":"43","author":"Agrusa","year":"2017","journal-title":"Ann Vasc Surg"},{"key":"B21","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1177\/1538574417702774","article-title":"A real-world experience comparison of percutaneous and open femoral exposure for endovascular abdominal aortic aneurysm repair in a tertiary medical center","volume":"51","author":"Mukherjee","year":"2017","journal-title":"Vasc Endovascular Surg"},{"key":"B22","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.jvs.2015.01.058","article-title":"Percutaneous versus femoral cutdown access for endovascular aneurysm repair","volume":"62","author":"Buck","year":"2015","journal-title":"J Vasc Surg"},{"key":"B23","doi-asserted-by":"publisher","first-page":"92","DOI":"10.12659\/msm.905350","article-title":"Femoral artery closure versus surgical cutdown for endovascular aortic repair: a single-center experience","volume":"24","author":"Yang","year":"2018","journal-title":"Med Sci Monit"},{"key":"B24","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1016\/j.jvs.2017.12.052","article-title":"Successful percutaneous access for endovascular aneurysm repair is significantly cheaper than femoral cutdown in a prospective randomized trial","volume":"68","author":"Uhlmann","year":"2018","journal-title":"J Vasc Surg"},{"key":"B25","doi-asserted-by":"publisher","first-page":"1364","DOI":"10.1016\/j.jvs.2017.03.431","article-title":"Comparison of percutaneous versus open femoral cutdown access for endovascular repair of ruptured abdominal aortic aneurysms","volume":"66","author":"Chen","year":"2017","journal-title":"J Vasc Surg"},{"key":"B26","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1016\/j.jvs.2015.08.111","article-title":"Safety and utility of total percutaneous endovascular aortic repair with a single perclose proglide closure device","volume":"63","author":"Ichihashi","year":"2016","journal-title":"J Vasc Surg"},{"key":"B27","doi-asserted-by":"publisher","first-page":"11","DOI":"10.5606\/tgkdc.dergisi.2022.21898","article-title":"Comparison of percutaneous access and open femoral cutdown in elective endovascular aortic repair of abdominal aortic aneurysms","volume":"30","author":"Akbulut","year":"2022","journal-title":"Turk Gogus Kalp Damar Cerrahisi Dergisi"},{"key":"B28","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1016\/j.avsg.2011.11.026","article-title":"Selective use of percutaneous endovascular aneurysm repair in women leads to fewer groin complications","volume":"26","author":"Al-Khatib","year":"2012","journal-title":"Ann Vasc Surg"},{"key":"B29","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/j.avsg.2020.07.004","article-title":"Access type for endovascular repair in ruptured abdominal aortic aneurysms does not affect Major morbidity or mortality","volume":"70","author":"Cheng","year":"2021","journal-title":"Ann Vasc Surg"},{"key":"B30","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1016\/j.jvir.2010.10.008","article-title":"Percutaneous suture-mediated closure versus surgical arteriotomy in endovascular aortic aneurysm repair","volume":"22","author":"Etezadi","year":"2011","journal-title":"J Vasc Interv Radiol"},{"key":"B31","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1002\/ccd.10072","article-title":"Percutaneous repair of abdominal aortic aneurysms using the aneurx stent graft and the percutaneous vascular surgery device","volume":"55","author":"Howell","year":"2002","journal-title":"Catheter Cardiovasc Interv"},{"key":"B32","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.avsg.2015.10.009","article-title":"Thirty-day outcomes after elective percutaneous or open endovascular repair of abdominal aortic aneurysms","volume":"31","author":"Kauvar","year":"2016","journal-title":"Ann Vasc Surg"},{"key":"B33","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1016\/j.jvs.2013.10.101","article-title":"A multicenter, randomized, controlled trial of totally percutaneous access versus open femoral exposure for endovascular aortic aneurysm repair (the pevar trial)","volume":"59","author":"Nelson","year":"2014","journal-title":"J Vasc Surg"},{"key":"B34","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/j.jvs.2017.10.075","article-title":"Comparison of access type on perioperative outcomes after endovascular aortic aneurysm repair","volume":"68","author":"Siracuse","year":"2018","journal-title":"J Vasc Surg"},{"key":"B35","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1016\/j.avsg.2008.09.002","article-title":"Percutaneous access for endovascular abdominal aortic aneurysm repair: can selection criteria be expanded?","volume":"23","author":"Smith","year":"2009","journal-title":"Ann Vasc Surg"},{"key":"B36","doi-asserted-by":"publisher","first-page":"1040929","DOI":"10.3389\/fsurg.2022.1040929","article-title":"Totally percutaneous endovascular repair for ruptured abdominal aortic aneurysms","volume":"9","author":"Tay","year":"2022","journal-title":"Front Surg"},{"key":"B37","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/j.jss.2019.02.011","article-title":"Outcomes and cost comparison of percutaneous endovascular aortic repair versus endovascular aortic repair with open femoral exposure","volume":"240","author":"Thurston","year":"2019","journal-title":"J Surg Res"},{"key":"B38","doi-asserted-by":"publisher","first-page":"6550759","DOI":"10.1155\/2022\/6550759","article-title":"Comparison of early efficacy of the percutaneous presuture technique with the femoral artery incision technique in endovascular aortic repair under local anesthesia for uncomplicated type B aortic dissection","volume":"2022","author":"Wu","year":"2022","journal-title":"J Interv Cardiol"},{"key":"B39","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/0197-2456(95)00134-4","article-title":"Assessing the quality of reports of randomized clinical trials: is blinding necessary?","volume":"17","author":"Jadad","year":"1996","journal-title":"Control Clin Trials"},{"key":"B40","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1007\/s00270-018-2072-3","article-title":"Long-Term evaluation of percutaneous groin access for evar","volume":"42","author":"Dwivedi","year":"2019","journal-title":"Cardiovasc Intervent Radiol"},{"key":"B41","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1056\/NEJMoa0808939","article-title":"Preventing surgical-site infections in nasal carriers of Staphylococcus Aureus","volume":"362","author":"Bode","year":"2010","journal-title":"N Engl J Med"},{"key":"B42","doi-asserted-by":"publisher","first-page":"1292","DOI":"10.1016\/j.jvir.2009.06.030","article-title":"Total percutaneous endovascular aneurysm repair with the dual 6-F perclose-at preclosing technique: a case-control study","volume":"20","author":"Jahnke","year":"2009","journal-title":"J Vasc Interv Radiol"},{"key":"B43","doi-asserted-by":"publisher","first-page":"919","DOI":"10.1016\/j.jvs.2007.12.029","article-title":"Midterm outcomes of femoral arteries after percutaneous endovascular aortic repair using the preclose technique","volume":"47","author":"Lee","year":"2008","journal-title":"J Vasc Surg"},{"key":"B44","doi-asserted-by":"publisher","first-page":"1213","DOI":"10.1016\/j.jvs.2013.04.065","article-title":"Predictors of percutaneous access failure requiring open femoral surgical conversion during endovascular aortic aneurysm repair","volume":"58","author":"Mousa","year":"2013","journal-title":"J Vasc Surg"},{"key":"B45","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1016\/j.jvs.2013.05.028","article-title":"Femoral artery calcification as a determinant of success for percutaneous access for endovascular abdominal aortic aneurysm repair","volume":"58","author":"Manunga","year":"2013","journal-title":"J Vasc Surg"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2025.1673817\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,24]],"date-time":"2025-11-24T06:29:54Z","timestamp":1763965794000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2025.1673817\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,24]]},"references-count":45,"alternative-id":["10.3389\/fcvm.2025.1673817"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2025.1673817","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,24]]},"article-number":"1673817"}}