{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T21:22:48Z","timestamp":1778707368510,"version":"3.51.4"},"reference-count":41,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T00:00:00Z","timestamp":1761609600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:p>Approximately one-third of patients with end-stage heart failure (ESHF) experience biventricular failure. Left ventricular assist devices (LVADs) are employed as a salvage therapy for individuals with advanced heart failure. The onset of right ventricular failure complicates the postoperative management of patients receiving LVAD support. Currently, no right ventricular assist device is specifically designed for isolated right heart failure support, necessitating cardiac surgeons worldwide to adopt various improvised methods using LVADs for right ventricular assistance. This report details the first case at Nanjing Drum Tower Hospital in which a Corheart 6 magnetically levitated LVAD was successfully employed for biventricular assistance in a patient with ESHF secondary to dilated cardiomyopathy.<\/jats:p>","DOI":"10.3389\/fcvm.2025.1677940","type":"journal-article","created":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T06:25:37Z","timestamp":1761632737000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":2,"title":["A case report: corheart 6 biventricular assist device therapy for end-stage heart failure in dilated cardiomyopathy"],"prefix":"10.3389","volume":"12","author":[{"given":"Qiuju","family":"Ding","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cheng","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhenjun","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ning","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun","family":"Pan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Min","family":"Ge","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2025,10,28]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"933","DOI":"10.1093\/eurheartj\/ehn309","article-title":"ESC guidelines for the diagnosis and treatment of acute and chronic heart failure 2008: the task force for the diagnosis and treatment of acute and chronic heart failure 2008 of the European Society of Cardiology. Developed in collaboration with the Heart Failure Association of the ESC (HFA) and endorsed by the European Society of Intensive Care Medicine (ESICM)","volume":"10","author":"Dickstein","year":"2008","journal-title":"Eur J Heart Fail"},{"key":"B2","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1016\/j.athoracsur.2022.11.023","article-title":"The society of thoracic surgeons intermacs 2022 annual report: focus on the 2018 heart transplant allocation system","volume":"115","author":"Yuzefpolskaya","year":"2023","journal-title":"Ann Thorac Surg"},{"key":"B3","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1007\/s10741-022-10282-2","article-title":"Right ventricular failure in left heart disease: from pathophysiology to clinical manifestations and prognosis","volume":"28","author":"Dini","year":"2023","journal-title":"Heart Fail Rev"},{"key":"B4","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1016\/j.healun.2015.10.003","article-title":"Seventh INTERMACS annual report: 15,000 patients and counting","volume":"34","author":"Kirklin","year":"2015","journal-title":"J Heart Lung Transplant"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1093\/ejcts\/ezz173","article-title":"Results of primary biventricular support: an analysis of data from the EUROMACS registry","volume":"56","author":"Vierecke","year":"2019","journal-title":"Eur J Cardiothorac Surg"},{"key":"B6","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1111\/aor.14498","article-title":"Preclinical evaluation of the fluid dynamics and hemocompatibility of the corheart 6 left ventricular assist device","volume":"47","author":"Fang","year":"2023","journal-title":"Artif Organs"},{"key":"B7","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1177\/03913988251351122","article-title":"Reoperation for the implantation of corheart 6 biventricular assist devices due to severe right ventricular failure and aortic regurgitation following left ventricular assist device implantation","volume":"48","author":"Liu","year":"2025","journal-title":"Int J Artif Organs"},{"key":"B8","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1016\/j.healun.2011.11.003","article-title":"Decision tree for adjuvant right ventricular support in patients receiving a left ventricular assist device","volume":"31","author":"Wang","year":"2012","journal-title":"J Heart Lung Transplant"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1040251","DOI":"10.3389\/fcvm.2022.1040251","article-title":"Prediction, prevention, and management of right ventricular failure after left ventricular assist device implantation: a comprehensive review","volume":"9","author":"Rodenas-Alesina","year":"2022","journal-title":"Front Cardiovasc Med"},{"key":"B10","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1016\/j.ccc.2018.03.001","article-title":"Prevention and treatment of right ventricular failure during left ventricular assist device therapy","volume":"34","author":"Raina","year":"2018","journal-title":"Crit Care Clin"},{"key":"B11","doi-asserted-by":"publisher","first-page":"1316","DOI":"10.1016\/j.jtcvs.2009.11.020","article-title":"Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes","volume":"139","author":"Kormos","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"B12","doi-asserted-by":"publisher","first-page":"S431","DOI":"10.1016\/j.healun.2020.01.226","article-title":"Increased right ventricular assist device (RVAD) utilization in patients with HeartMate 3 left ventricular assist device (LVAD) in the post-approval era","volume":"39","author":"Marshall","year":"2020","journal-title":"J Heart Lung Transplant"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1562","DOI":"10.1016\/j.ajem.2019.04.050","article-title":"Left ventricular assist devices and their complications: a review for emergency clinicians","volume":"37","author":"Long","year":"2019","journal-title":"Am J Emerg Med"},{"key":"B14","doi-asserted-by":"publisher","first-page":"e003745","DOI":"10.1161\/CIRCHEARTFAILURE.116.003745","article-title":"Accuracy of seattle heart failure model and HeartMate II risk score in non-inotrope-dependent advanced heart failure patients. insights from the ROADMAP study (Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device and Medical Management in Ambulatory Heart Failure Patients)","volume":"10","author":"Lanfear","year":"2017","journal-title":"Circ: Heart Fail"},{"key":"B15","doi-asserted-by":"publisher","first-page":"1080","DOI":"10.1016\/j.healun.2017.07.005","article-title":"Eighth annual INTERMACS report: special focus on framing the impact of adverse events","volume":"36","author":"Kirklin","year":"2017","journal-title":"J Heart Lung Transplant"},{"key":"B16","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1016\/j.athoracsur.2019.12.005","article-title":"The society of thoracic surgeons intermacs 2019 annual report: the changing landscape of devices and indications","volume":"109","author":"Teuteberg","year":"2020","journal-title":"Ann Thorac Surg"},{"key":"B17","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1097\/01.MAT.0000084109.47034.8A","article-title":"Biventricular support with the Jarvik 2000 axial flow pump: a feasibility study","volume":"49","author":"Radovancevic","year":"2003","journal-title":"ASAIO J"},{"key":"B18","doi-asserted-by":"publisher","first-page":"S179","DOI":"10.1161\/CIRCULATIONAHA.110.011502","article-title":"Biventricular circulatory support with two miniaturized implantable assist devices","volume":"124","author":"Krabatsch","year":"2011","journal-title":"Circulation"},{"key":"B19","doi-asserted-by":"publisher","first-page":"936","DOI":"10.1016\/j.jtcvs.2010.04.007","article-title":"Successful use of the HeartWare HVAD rotary blood pump for biventricular support","volume":"140","author":"Strueber","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"B20","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1016\/j.healun.2011.04.004","article-title":"Survival after biventricular assist device implantation: an analysis of the interagency registry for mechanically assisted circulatory support database","volume":"30","author":"Cleveland","year":"2011","journal-title":"J Heart Lung Transplant"},{"key":"B21","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1016\/j.healun.2018.05.001","article-title":"Multicenter experience with durable biventricular assist devices","volume":"37","author":"Shah","year":"2018","journal-title":"J Heart Lung Transplant"},{"key":"B22","doi-asserted-by":"publisher","first-page":"1399","DOI":"10.1016\/j.healun.2018.08.008","article-title":"An international multicenter experience of biventricular support with HeartMate 3 ventricular assist systems","volume":"37","author":"Lavee","year":"2018","journal-title":"J Heart Lung Transplant"},{"key":"B23","doi-asserted-by":"publisher","first-page":"2304","DOI":"10.1002\/ejhf.3323","article-title":"Right heart failure with left ventricular assist devices: preoperative, perioperative and postoperative management strategies. A clinical consensus statement of the Heart Failure Association (HFA) of the ESC","volume":"26","author":"Adamopoulos","year":"2024","journal-title":"Eur J Heart Fail"},{"key":"B24","doi-asserted-by":"publisher","first-page":"e003863","DOI":"10.1161\/CIRCHEARTFAILURE.117.003863","article-title":"Early right ventricular assist device use in patients undergoing continuous-flow left ventricular assist device implantation: incidence and risk factors from the interagency registry for mechanically assisted circulatory support","volume":"10","author":"Kiernan","year":"2017","journal-title":"Circ Heart Fail"},{"key":"B25","doi-asserted-by":"publisher","first-page":"S14","DOI":"10.1161\/CIRCULATIONAHA.112.000335","article-title":"Load dependency of right ventricular performance is a major factor to be considered in decision making before ventricular assist device implantation","volume":"128","author":"Dandel","year":"2013","journal-title":"Circulation"},{"key":"B26","doi-asserted-by":"publisher","first-page":"I198","DOI":"10.1161\/01.cir.0000032906.33237.1c","article-title":"Predictors of severe right ventricular failure after implantable left ventricular assist device insertion: analysis of 245 patients","volume":"106","author":"Ochiai","year":"2002","journal-title":"Circulation"},{"key":"B27","doi-asserted-by":"publisher","first-page":"2181","DOI":"10.1016\/S0003-4975(99)00753-5","article-title":"Preoperative risk factors for right ventricular failure after implantable left ventricular assist device insertion","volume":"68","author":"Fukamachi","year":"1999","journal-title":"Ann Thorac Surg"},{"key":"B28","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1536\/ihj.17-487","article-title":"A useful scoring system for predicting right ventricular assist device requirement among patients with a paracorporeal left ventricular assist device","volume":"59","author":"Nitta","year":"2018","journal-title":"Int Heart J"},{"key":"B29","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1016\/j.cardfail.2015.10.019","article-title":"Pulmonary artery pulsatility index is associated with right ventricular failure after left ventricular assist device surgery","volume":"22","author":"Morine","year":"2016","journal-title":"J Card Fail"},{"key":"B30","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1002\/ejhf.1679","article-title":"Pulmonary artery pulsatility index: physiological basis and clinical application","volume":"22","author":"Lim","year":"2020","journal-title":"Eur J Heart Fail"},{"key":"B31","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.cardfail.2012.11.001","article-title":"Postoperative right ventricular failure after left ventricular assist device placement is predicted by preoperative echocardiographic structural, hemodynamic, and functional parameters","volume":"19","author":"Raina","year":"2013","journal-title":"J Card Fail"},{"key":"B32","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1016\/j.jchf.2013.02.005","article-title":"Serial echocardiography using tissue Doppler and speckle tracking imaging to monitor right ventricular failure before and after left ventricular assist device surgery","volume":"1","author":"Kato","year":"2013","journal-title":"JACC Heart Fail"},{"key":"B33","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.healun.2020.12.006","article-title":"The results of a single-center experience with HeartMate 3 in a biventricular configuration","volume":"40","author":"McGiffin","year":"2021","journal-title":"J Heart Lung Transplant"},{"key":"B34","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1053\/j.jvca.2015.07.012","article-title":"Pulmonary bleeding during right ventricular support after left ventricular assist device implantation","volume":"30","author":"Welp","year":"2016","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"B35","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1016\/j.healun.2022.12.004","article-title":"The 2023 international society for heart and lung transplantation guidelines for mechanical circulatory support: a 10- year update","volume":"42","author":"Saeed","year":"2023","journal-title":"J Heart Lung Transplant"},{"key":"B36","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.healun.2016.10.001","article-title":"Prevention of HeartMate II pump thrombosis through clinical management: the prevent multi-center study","volume":"36","author":"Maltais","year":"2017","journal-title":"J Heart Lung Transplant"},{"key":"B37","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.bpa.2015.04.001","article-title":"Hepatic and renal effects of cardiopulmonary bypass","volume":"29","author":"Di Tomasso","year":"2015","journal-title":"Best Pract Res Clin Anaesthesiol"},{"key":"B38","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1038\/nrneph.2013.232","article-title":"Fluid management for the prevention and attenuation of acute kidney injury","volume":"10","author":"Prowle","year":"2014","journal-title":"Nat Rev Nephrol"},{"key":"B39","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1177\/1089253213506788","article-title":"Management of patients with implanted ventricular assist devices for noncardiac surgery: a clinical review","volume":"18","author":"Hessel","year":"2014","journal-title":"Semin Cardiothorac Vasc Anesth"},{"key":"B40","doi-asserted-by":"publisher","first-page":"311","DOI":"10.21037\/acs-2021-cfmcs-34","article-title":"Contemporary outcomes of continuous-flow biventricular assist devices","volume":"10","author":"Farag","year":"2021","journal-title":"Ann Cardiothorac Surg"},{"key":"B41","doi-asserted-by":"publisher","first-page":"2003","DOI":"10.1161\/CIRCULATIONAHA.117.028303","article-title":"Hemocompatibility-Related outcomes in the MOMENTUM 3 trial at 6 months: a randomized controlled study of a fully magnetically levitated pump in advanced heart failure","volume":"135","author":"Uriel","year":"2017","journal-title":"Circulation"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2025.1677940\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T06:25:44Z","timestamp":1761632744000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2025.1677940\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,28]]},"references-count":41,"alternative-id":["10.3389\/fcvm.2025.1677940"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2025.1677940","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,28]]},"article-number":"1677940"}}