{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T05:34:51Z","timestamp":1767591291958,"version":"3.48.0"},"reference-count":28,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T00:00:00Z","timestamp":1767571200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001826","name":"ZonMw","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001826","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The safety of cervical spinal manipulative therapy (cSMT) remains debated. Although generally considered safe, cSMT has been linked to rare vascular complications such as cervical arterial dissection and cerebrovascular events. One hypothesis is that pre-existing vascular conditions may increase susceptibility to mechanical forces induced by cSMT, but supporting evidence is limited. Considering ethical and practical constraints in human research, these potential adverse events can only be studied in animal models.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aim<\/jats:title>\n                    <jats:p>To evaluate the effects of cSMT on structure, function and inflammatory markers of cervical arteries and mortality in healthy animals and animals with vascular pathology.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      A systematic search of PubMed, Embase.com and EBSCO\/CINAHL was conducted on March 19, 2025 to identify controlled experimental studies on the effects of cSMT in animals with and without vascular pathology. Two independent reviewers conducted study selection, risk of bias assessment and data extraction. Random-effects meta-analyses were performed for stenosis rate, cross-sectional area, mechanical properties (load, stress, strain), blood flow parameters (velocity, volume), and inflammatory markers (high sensitivity C-Reactive Protein and macrophages). Hedges\n                      <jats:italic>g<\/jats:italic>\n                      was used to report effect sizes.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Six studies met the selection criteria. Most showed unclear risk of bias. In healthy animals, cSMT had no significant effect on stress, strain or blood flow volume (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20092). In animals with vascular pathology, cSMT significantly increased macrophage infiltration (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20092), but had no effect on stenosis rate (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20093), cross-sectional area (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20092), stress (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20092), strain (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20092) or peak systolic velocity (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20092). In animals with vascular pathology compared to healthy animals receiving cSMT, mechanical strain decreased significantly (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20092), while no difference was found for mechanical stress (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20092). No study reported mortality as an outcome.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In animals with vascular pathology, cSMT increases inflammatory responses and atherosclerosis reduces tensile strain of cervical arteries. These findings warrant cautious interpretation and may not translate to humans.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Systematic Review Registration<\/jats:title>\n                    <jats:p>\n                      <jats:ext-link>https:\/\/www.crd.york.ac.uk\/PROSPERO\/view\/CRD42023471983<\/jats:ext-link>\n                      , PROSPERO CRD42023471983.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fcvm.2025.1700494","type":"journal-article","created":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T05:30:02Z","timestamp":1767591002000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["The effects of mobilization and manipulation on mortality and structure, function and inflammatory markers in cervical blood vessels: a systematic review and meta-analysis of studies in healthy animals and animals with pre-existing vascular pathology"],"prefix":"10.3389","volume":"12","author":[{"given":"Rogier F.","family":"de Best","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michel W.","family":"Coppieters","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christos","family":"Bozis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kirsten A.","family":"van Gelderen-Ziesemer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlijn R.","family":"Hooijmans","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gwendolyne G. M.","family":"Scholten-Peeters","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2026,1,5]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"E55","DOI":"10.36076\/ppj\/2019.22.E55","article-title":"Manipulation and mobilization for treating chronic nonspecific neck pain: a systematic review and meta-analysis for an appropriateness panel","volume":"22","author":"Coulter","year":"2019","journal-title":"Pain Phys"},{"key":"B2","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1186\/s12998-022-00459-9","article-title":"The effectiveness of manual and exercise therapy on headache intensity and frequency among patients with cervicogenic headache: a systematic review and meta-analysis","volume":"30","author":"Bini","year":"2022","journal-title":"Chiropr Man Ther"},{"key":"B3","doi-asserted-by":"publisher","first-page":"5011","DOI":"10.3390\/jcm10215011","article-title":"Spinal manipulative therapy for acute neck pain: a systematic review and meta-analysis of randomised controlled trials","volume":"10","author":"Chaibi","year":"2021","journal-title":"J Clin Med"},{"key":"B4","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1080\/10669817.2023.2250164","article-title":"Development of a diagnostic support tool for predicting cervical arterial dissection in primary care","volume":"32","author":"Thomas","year":"2024","journal-title":"J Man Manip Ther"},{"key":"B5","doi-asserted-by":"publisher","first-page":"e498","DOI":"10.7759\/cureus.498","article-title":"Systematic review and meta-analysis of chiropractic care and cervical artery dissection: no evidence for causation","volume":"8","author":"Church","year":"2016","journal-title":"Cureus"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12998-016-0124-9","article-title":"Does case misclassification threaten the validity of studies investigating the relationship between neck manipulation and vertebral artery dissection stroke? No","volume":"24","author":"Murphy","year":"2016","journal-title":"Chiropr Man Therap"},{"key":"B7","doi-asserted-by":"publisher","first-page":"842","DOI":"10.1016\/j.jstrokecerebrovasdis.2016.10.031","article-title":"Risk of carotid stroke after chiropractic care: a population-based case-crossover study","volume":"26","author":"Cassidy","year":"2017","journal-title":"J Stroke Cerebrovasc Dis"},{"key":"B8","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.jbmt.2024.10.018","article-title":"Serious adverse events associated with conservative physical procedures directed towards the cervical spine: a systematic review","volume":"41","author":"Leung","year":"2025","journal-title":"J Bodyw Mov Ther"},{"key":"B9","doi-asserted-by":"publisher","first-page":"3155","DOI":"10.1161\/STR.0000000000000016","article-title":"Cervical arterial dissections and association with cervical manipulative therapy: a statement for healthcare professionals from the American Heart Association\/American stroke association","volume":"45","author":"Biller","year":"2014","journal-title":"Stroke"},{"key":"B10","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1186\/s12998-022-00438-0","article-title":"Kinematics of the head and associated vertebral artery length changes during high-velocity, low-amplitude cervical spine manipulation","volume":"30","author":"Gorrell","year":"2022","journal-title":"Chiropr Man Therap"},{"key":"B11","doi-asserted-by":"publisher","first-page":"880","DOI":"10.3174\/ajnr.a7921","article-title":"MR imaging of carotid artery atherosclerosis: updated evidence on high-risk plaque features and emerging trends","volume":"44","author":"Benson","year":"2023","journal-title":"Am J Neuroradiol"},{"key":"B12","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1016\/j.rcl.2019.07.007","article-title":"Causes of acute stroke","volume":"57","author":"Knight-Greenfield","year":"2019","journal-title":"Radiol Clin North Am"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.2519\/jospt.2022.11147","article-title":"Position statement: international framework for examination of the cervical region for potential of vascular pathologies of the neck prior to musculoskeletal intervention: international IFOMPT cervical framework","volume":"13","author":"Rushton","year":"2023","journal-title":"J Orthop Sports Phys Ther"},{"key":"B14","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1159\/000149578","article-title":"Effect of cervical spine manipulation on a pre-existing vascular lesion within the canine vertebral artery","volume":"26","author":"Wynd","year":"2008","journal-title":"Cerebrovasc Dis"},{"key":"B15","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1016\/S0161-4754(99)70030-8","article-title":"Vertebral artery flow and cervical manipulation: an experimental study","volume":"22","author":"Licht","year":"1999","journal-title":"J Manipulative Physiol Ther"},{"key":"B16","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1186\/s13643-021-01626-4","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"10","author":"Page","year":"2021","journal-title":"Syst Rev"},{"key":"B17","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1177\/00236772211045485","article-title":"Laboratory animals search filter for different literature databases: PubMed, Embase, Web of Science and PsycINFO","volume":"56","author":"van der Mierden","year":"2022","journal-title":"Lab Anim"},{"key":"B18","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1186\/s13643-016-0384-4","article-title":"Rayyan-a web and mobile app for systematic reviews","volume":"5","author":"Ouzzani","year":"2016","journal-title":"Syst Rev"},{"key":"B19","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1016\/j.jmpt.2017.12.002","article-title":"Uniaxial tensile properties of atherosclerotic carotid artery after mobilization of pushing on qiao-gong: a safety study using an animal model of carotid atherosclerosis","volume":"41","author":"Qi","year":"2018","journal-title":"J Manipulative Physiol Ther"},{"key":"B20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2019\/3793840","article-title":"Effects of cervical rotatory manipulation (CRM) on carotid atherosclerosis plaque in vulnerability: a histological and immunohistochemical study using animal model","volume":"2019","author":"Qi","year":"2019","journal-title":"Biomed Res Int"},{"key":"B21","doi-asserted-by":"publisher","first-page":"5189356","DOI":"10.1155\/2017\/5189356","article-title":"Cervical rotatory manipulation decreases uniaxial tensile properties of rabbit atherosclerotic internal carotid artery","volume":"2017","author":"Zhang","year":"2017","journal-title":"Evid Based Complement Alternat Med"},{"key":"B22","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1016\/j.jmpt.2022.03.022","article-title":"Effects of cervical rotatory manipulation on hemodynamics and plaque stability of atherosclerotic internal carotid artery in rabbits","volume":"45","author":"Zhang","year":"2022","journal-title":"J Manipulative Physiol Ther"},{"key":"B23","doi-asserted-by":"publisher","first-page":"2344","DOI":"10.12659\/MSM.913351","article-title":"Effects of cervical rotatory manipulation on internal carotid artery in hemodynamics using an animal model of carotid atherosclerosis: a safety study","volume":"25","author":"Guan","year":"2019","journal-title":"Med Sci Monit"},{"key":"B24","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.ejphar.2017.05.010","article-title":"Animal models of atherosclerosis","volume":"816","author":"Emini Veseli","year":"2017","journal-title":"Eur J Pharmacol"},{"key":"B25","doi-asserted-by":"publisher","first-page":"e0187271","DOI":"10.1371\/journal.pone.0187271","article-title":"Facilitating healthcare decisions by assessing the certainty in the evidence from preclinical animal studies","volume":"13","author":"Hooijmans","year":"2018","journal-title":"PLoS One"},{"key":"B26","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1515\/jom-2024-0203","article-title":"Signs and symptoms of vertebrobasilar insufficiency secondary to atherosclerosis: a systematic review","volume":"125","author":"Moors","year":"2025","journal-title":"J Osteopath Med"},{"key":"B27","doi-asserted-by":"publisher","first-page":"e3000410","DOI":"10.1371\/journal.pbio.3000410","article-title":"The arrive guidelines 2.0: updated guidelines for reporting animal research","volume":"18","author":"Percie du Sert","year":"2020","journal-title":"PLoS Biol"},{"key":"B28","doi-asserted-by":"publisher","first-page":"1334","DOI":"10.1038\/s41592-022-01615-y","article-title":"The EQIPD framework for rigor in the design, conduct, analysis and documentation of animal experiments","volume":"19","author":"Vollert","year":"2022","journal-title":"Nat Methods"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2025.1700494\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T05:30:03Z","timestamp":1767591003000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2025.1700494\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,5]]},"references-count":28,"alternative-id":["10.3389\/fcvm.2025.1700494"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2025.1700494","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,5]]},"article-number":"1700494"}}