{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T06:53:35Z","timestamp":1775026415721,"version":"3.50.1"},"reference-count":75,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T00:00:00Z","timestamp":1775001600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:p>Acute type A aortic dissection (ATAAD) is a life-threatening cardiovascular emergency where delays in diagnosis worsen outcomes. While computed tomography angiography remains the diagnostic gold standard, its requirement for patient transport, contrast administration, and radiation exposure limits its utility in urgent scenarios. Multimodal point-of-care ultrasound (PoCUS) presents a viable bedside alternative by combining transthoracic echocardiography, vascular ultrasound, and, when available, transesophageal echocardiography. This integrated approach facilitates a rapid, comprehensive assessment, allowing for the detection of key findings\u2014such as pericardial effusion, aortic root dilation, and an intimal flap\u2014within minutes. PoCUS can shorten the time from clinical suspicion to treatment decision, avoid the risks associated with transporting unstable patients, and assist in differentiating other causes of acute chest pain. This perspective article scrutinizes the role of multimodal PoCUS in screening for ATAAD, addresses its technical and training limitations, and explores future directions, including integration with artificial intelligence, standardized training protocols, and optimized clinical workflows. The goal is to inform the development of more efficient, timely diagnostic strategies for this critical condition.<\/jats:p>","DOI":"10.3389\/fcvm.2026.1780067","type":"journal-article","created":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T05:00:03Z","timestamp":1775019603000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Rapid bedside multimodal ultrasound screening for acute type A aortic dissection: a perspective"],"prefix":"10.3389","volume":"13","author":[{"given":"Hua","family":"Xu","sequence":"first","affiliation":[{"name":"Department of Ultrasound, Shaanxi Provincial Hospital of Chinese Medicine","place":["Xi\u2019an, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jin-Yan","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Ultrasound, Shaanxi Provincial Hospital of Chinese Medicine","place":["Xi\u2019an, China"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2026,4,1]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1009","DOI":"10.1001\/jamacardio.2022.2718","article-title":"Early mortality in type A acute aortic dissection: insights from the international registry of acute aortic dissection","volume":"7","author":"Harris","year":"2022","journal-title":"JAMA Cardiol"},{"key":"B2","doi-asserted-by":"publisher","first-page":"ezae039","DOI":"10.1093\/ejcts\/ezae039","article-title":"Mortality after non-surgically treated acute type A aortic dissection is higher than previously reported","volume":"65","author":"Teurneau-Hermansson","year":"2024","journal-title":"Eur J Cardiothorac Surg"},{"key":"B3","doi-asserted-by":"publisher","first-page":"3519","DOI":"10.1038\/s41598-021-83180-6","article-title":"Impact of time between diagnosis to treatment in acute type A aortic dissection","volume":"11","author":"Matthews","year":"2021","journal-title":"Sci Rep"},{"key":"B4","doi-asserted-by":"publisher","first-page":"24","DOI":"10.21037\/jovs-20-54","article-title":"Acute type A aortic dissection: timeline between onset and treatment","volume":"7","author":"De Vos","year":"2021","journal-title":"J Vis Surg"},{"key":"B5","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1001\/jama.283.7.897","article-title":"The international registry of acute aortic dissection (IRAD): new insights into an old disease","volume":"283","author":"Hagan","year":"2000","journal-title":"JAMA"},{"key":"B6","doi-asserted-by":"publisher","first-page":"2873","DOI":"10.1093\/eurheartj\/ehu281","article-title":"2014 ESC guidelines on the diagnosis and treatment of aortic diseases: document covering acute and chronic aortic diseases of the thoracic and abdominal aorta of the adult. The Task Force for the Diagnosis and Treatment of Aortic Diseases of the European Society of Cardiology (ESC)","volume":"35","author":"Erbel","year":"2014","journal-title":"Eur Heart J"},{"key":"B7","doi-asserted-by":"publisher","first-page":"1911","DOI":"10.1161\/CIRCULATIONAHA.110.006320","article-title":"Correlates of delayed recognition and treatment of acute type A aortic dissection: the International Registry of Acute Aortic Dissection (IRAD)","volume":"124","author":"Harris","year":"2011","journal-title":"Circulation"},{"key":"B8","doi-asserted-by":"publisher","first-page":"e0141929","DOI":"10.1371\/journal.pone.0141929","article-title":"Clinical predictors for delayed or inappropriate initial diagnosis of type A acute aortic dissection in the emergency room","volume":"10","author":"Hirata","year":"2015","journal-title":"PLoS One"},{"key":"B9","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1161\/CIRCIMAGING.109.850206","article-title":"Noninvasive imaging approaches to evaluate the patient with known or suspected aortic disease","volume":"2","author":"Nienaber","year":"2009","journal-title":"Circ Cardiovasc Imaging"},{"key":"B10","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1007\/s10554-025-03336-7","article-title":"CT Angiography of acute aortic syndrome in patients with chronic kidney disease","volume":"41","author":"Papachristodoulou","year":"2025","journal-title":"Int J Cardiovasc Imaging"},{"key":"B11","doi-asserted-by":"publisher","first-page":"253","DOI":"10.2147\/IJNRD.S371700","article-title":"Contrast-induced acute kidney injury: evidence in support of its existence and a review of its pathogenesis and management","volume":"15","author":"Chaudhari","year":"2022","journal-title":"Int J Nephrol Renovasc Dis"},{"key":"B12","doi-asserted-by":"publisher","first-page":"118","DOI":"10.55729\/2000-9666.1178","article-title":"Type A aortic dissection and non-contrast computed tomography","volume":"13","author":"Spangenberg","year":"2023","journal-title":"J Community Hosp Intern Med Perspect"},{"key":"B13","doi-asserted-by":"publisher","first-page":"101696","DOI":"10.1016\/j.rmcr.2022.101696","article-title":"Diagnosing aortic dissection using point of care ultrasound","volume":"39","author":"Gunjan","year":"2022","journal-title":"Respir Med Case Rep"},{"key":"B14","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1007\/s10396-021-01151-w","article-title":"Use of aortic point-of-care ultrasound in conventional and emergent echocardiography","volume":"49","author":"Nishigami","year":"2022","journal-title":"J Med Ultrason"},{"key":"B15","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1016\/j.jemermed.2020.09.015","article-title":"Diagnosis of a large type-A aortic dissection using point-of-care ultrasound","volume":"60","author":"Wisbeck","year":"2021","journal-title":"J Emerg Med"},{"key":"B16","doi-asserted-by":"publisher","first-page":"S143","DOI":"10.1016\/j.annemergmed.2017.07.334","article-title":"Point-of-care ultrasound for the detection of aortic dissections in the emergency department","volume":"70","author":"Gibbons","year":"2017","journal-title":"Ann Emerg Med"},{"key":"B17","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.jemermed.2025.10.012","article-title":"What echocardiographic findings suggest acute type A aortic dissection?","volume":"80","author":"Alerhand","year":"2025","journal-title":"J Emerg Med"},{"key":"B18","doi-asserted-by":"publisher","first-page":"1309","DOI":"10.1002\/jum.15223","article-title":"Early screening for aortic dissection with point-of-care ultrasound by emergency physicians: a prospective pilot study","volume":"39","author":"Wang","year":"2020","journal-title":"J Ultrasound Med"},{"key":"B19","doi-asserted-by":"publisher","first-page":"720","DOI":"10.1111\/1742-6723.14262","article-title":"Review article: accuracy of emergency physician performed point-of-care ultrasound of the thoracic aorta: a systematic review and narrative synthesis of the literature","volume":"35","author":"Thomas","year":"","journal-title":"Emerg Med Australas"},{"key":"B20","doi-asserted-by":"publisher","first-page":"114","DOI":"10.4103\/HEARTVIEWS.HEARTVIEWS_33_17","article-title":"Real-time imaging of aortic root rupture and cardiac tamponade in acute aortic dissection","volume":"19","author":"Cianciulli","year":"2018","journal-title":"Heart Views"},{"key":"B21","doi-asserted-by":"publisher","first-page":"103","DOI":"10.31083\/j.rcm.2018.03.3182","article-title":"Usefulness of ultrasound in the management of aortic dissection","volume":"19","author":"Liu","year":"2018","journal-title":"Rev Cardiovasc Med"},{"key":"B22","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1016\/j.echo.2014.11.015","article-title":"Multimodality imaging of diseases of the thoracic aorta in adults: from the American Society of Echocardiography and the European Association of Cardiovascular Imaging: endorsed by the Society of Cardiovascular Computed Tomography and Society for Cardiovascular Magnetic Resonance","volume":"28","author":"Goldstein","year":"2015","journal-title":"J Am Soc Echocardiogr"},{"key":"B23","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1002\/clc.20807","article-title":"Accuracy of transthoracic echocardiography for the measurement of the ascending aorta: comparison with transesophageal echocardiography","volume":"33","author":"Kabirdas","year":"2010","journal-title":"Clin Cardiol"},{"key":"B24","doi-asserted-by":"publisher","first-page":"1022","DOI":"10.1148\/rg.2021200142","article-title":"Transthoracic echocardiography: Beginner\u2019s guide with emphasis on blind spots as identified with CT and MRI","volume":"41","author":"Grant","year":"2021","journal-title":"Radiographics"},{"key":"B25","doi-asserted-by":"publisher","first-page":"2084.e1","DOI":"10.1016\/j.ajem.2011.11.012","article-title":"ED ultrasound diagnosis of a type B aortic dissection using the suprasternal view","volume":"30","author":"Rosenberg","year":"2012","journal-title":"Am J Emerg Med"},{"key":"B26","doi-asserted-by":"publisher","first-page":"e041804","DOI":"10.1161\/JAHA.125.041804","article-title":"Optimal management of isolated left vertebral artery in total arch replacement with frozen elephant trunk for aortic dissection","volume":"14","author":"Zhou","year":"2025","journal-title":"J Am Heart Assoc"},{"key":"B27","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.jtcvs.2022.09.034","article-title":"Survival after operative repair of acute type A aortic dissection varies according to the presence and type of preoperative malperfusion","volume":"168","author":"Wolfe","year":"2024","journal-title":"J Thorac Cardiovasc Surg"},{"key":"B28","first-page":"409","article-title":"Role of echocardiography in the diagnosis of acute aortic syndrome","volume":"58","author":"J\u00e1nosi","year":"2010","journal-title":"Minerva Cardioangiol"},{"key":"B29","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1056\/NEJM199301073280101","article-title":"The diagnosis of thoracic aortic dissection by noninvasive imaging procedures","volume":"328","author":"Nienaber","year":"1993","journal-title":"N Engl J Med"},{"key":"B30","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1016\/j.echo.2025.03.017","article-title":"Intraoperative transesophageal echocardiography in acute type A aortic dissection: contemporary approach","volume":"38","author":"Kelava","year":"2025","journal-title":"J Am Soc Echocardiogr"},{"key":"B31","doi-asserted-by":"publisher","first-page":"1669","DOI":"10.3390\/diagnostics14151669","article-title":"Artificial intelligence (AI) applications for point of care ultrasound (POCUS) in low-resource settings: a scoping review","volume":"14","author":"Kim","year":"2024","journal-title":"Diagnostics (Basel)"},{"key":"B32","doi-asserted-by":"publisher","first-page":"65","DOI":"10.24908\/pocus.v8i1.16209","article-title":"A longitudinal evaluation of a multimodal POCUS CuBirriculum in pediatric residents","volume":"8","author":"Sabnani","year":"2023","journal-title":"POCUS J"},{"key":"B33","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1007\/s11739-022-03126-2","article-title":"Point-of-care ultrasound improves clinical outcomes in patients with acute onset dyspnea: a systematic review and meta-analysis","volume":"18","author":"Szab\u00f3","year":"2023","journal-title":"Intern Emerg Med"},{"key":"B34","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.ajem.2021.11.021","article-title":"Adverse events during intrahospital transport of critically ill patients: a systematic review and meta-analysis","volume":"52","author":"Murata","year":"2022","journal-title":"Am J Emerg Med"},{"key":"B35","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1177\/08850666231224391","article-title":"POCUS in the PICU: a narrative review of evidence-based bedside ultrasound techniques ready for prime-time in pediatric critical care","volume":"40","author":"Naber","year":"2025","journal-title":"J Intensive Care Med"},{"key":"B36","doi-asserted-by":"publisher","first-page":"e432","DOI":"10.3928\/19382359-20210912-01","article-title":"Use of point-of-care ultrasound in the pediatric and neonatal emergency transport realm","volume":"50","author":"Foster","year":"2021","journal-title":"Pediatr Ann"},{"key":"B37","doi-asserted-by":"publisher","first-page":"e51032","DOI":"10.7759\/cureus.51032","article-title":"Point-of-care ultrasound for the diagnosis of frequent cardiovascular diseases: a review","volume":"15","author":"Calderon Martinez","year":"2023","journal-title":"Cureus"},{"key":"B38","doi-asserted-by":"publisher","first-page":"108500","DOI":"10.1016\/j.rmed.2025.108500","article-title":"Point of care ultrasound as a bedside diagnostic tool in acute dyspnea patients in emergency department for timely management","volume":"250","author":"Hamza Yousef","year":"2025","journal-title":"Respir Med"},{"key":"B39","doi-asserted-by":"publisher","first-page":"118","DOI":"10.24908\/pocus.v8i2.16533","article-title":"Acute type A aortic dissection diagnosed by POCUS in a 29-year-old man","volume":"8","author":"C\u00e1rdenas L\u00f3pez","year":"2023","journal-title":"POCUS J"},{"key":"B40","doi-asserted-by":"publisher","first-page":"e43527","DOI":"10.7759\/cureus.43527","article-title":"Ultrasound assessment of postprocedural arterial pseudoaneurysms: techniques, clinical implications, and emergency department integration","volume":"15","author":"Azzo","year":"2023","journal-title":"Cureus"},{"key":"B41","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1159\/000503000","article-title":"Point-of-care ultrasonography for objective volume management in end-stage renal disease","volume":"49","author":"Koratala","year":"2020","journal-title":"Blood Purif"},{"key":"B42","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1186\/s13049-020-00740-x","article-title":"Point-of-care ultrasound induced changes in management of unselected patients in the emergency department\u2014a prospective single-blinded observational trial","volume":"28","author":"Weile","year":"2020","journal-title":"Scand J Trauma Resusc Emerg Med"},{"key":"B43","doi-asserted-by":"publisher","first-page":"508","DOI":"10.1111\/obr.12274","article-title":"Intraoperative mechanical ventilation strategies for obese patients: a systematic review and network meta-analysis","volume":"16","author":"Wang","year":"2015","journal-title":"Obes Rev"},{"key":"B44","doi-asserted-by":"publisher","first-page":"230127","DOI":"10.1183\/20734735.0127-2023","article-title":"Lung imaging methods: indications, strengths and limitations","volume":"20","author":"T\u00e1rnoki","year":"2024","journal-title":"Breathe (Sheff)"},{"key":"B45","doi-asserted-by":"publisher","first-page":"A378","DOI":"10.1136\/archdischild-2021-rcpch.658","article-title":"The unfulfilled potential of point-of-care ultrasound (POCUS) in paediatric emergency medicine (PEM) training","volume":"106","author":"Sajjad","year":"2021","journal-title":"Arch Dis Child"},{"key":"B46","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1002\/jum.16095","article-title":"Development and validation of a point-of-care-ultrasound image quality assessment tool: the POCUS IQ scale","volume":"42","author":"Dessie","year":"2023","journal-title":"J Ultrasound Med"},{"key":"B47","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1080\/17843286.2021.1927581","article-title":"Overview of current implementation and limitations of point-of-care ultrasound in the emergency department: a nationwide survey in Belgium","volume":"77","author":"Rimbaut","year":"2022","journal-title":"Acta Clin Belg"},{"key":"B48","doi-asserted-by":"publisher","first-page":"205","DOI":"10.5811\/westjem.18449","article-title":"Simulation improves emergency medicine Residents\u2019 clinical performance of aorta point-of-care ultrasound","volume":"25","author":"Wubben","year":"2024","journal-title":"West J Emerg Med"},{"key":"B49","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1186\/s13089-022-00301-6","article-title":"Measuring the accuracy of cardiac output using POCUS: the introduction of artificial intelligence into routine care","volume":"14","author":"Shaikh","year":"2022","journal-title":"Ultrasound J"},{"key":"B50","doi-asserted-by":"publisher","first-page":"e69205","DOI":"10.7759\/cureus.69205","article-title":"Assessment of point-of-care ultrasound (POCUS) knowledge among Lebanese medical residents","volume":"16","author":"Mouawad","year":"2024","journal-title":"Cureus"},{"key":"B51","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1093\/milmed\/usad127","article-title":"Confidence and utilization are poorly associated with point-of-care ultrasound competency among internal medicine trainees","volume":"188","author":"Elliott","year":"2023","journal-title":"Mil Med"},{"key":"B52","doi-asserted-by":"publisher","first-page":"e239328","DOI":"10.1136\/bcr-2020-239328","article-title":"Acute aortic dissection with highly compressed true lumen: unanticipated pitfall of point-of-care ultrasonography","volume":"14","author":"Dote","year":"2021","journal-title":"BMJ Case Rep"},{"key":"B53","doi-asserted-by":"publisher","first-page":"V5","DOI":"10.21980\/J8964Z","article-title":"Aortic dissection case report","volume":"8","author":"Bunce","year":"2023","journal-title":"J Educ Teach Emerg Med"},{"key":"B54","doi-asserted-by":"publisher","first-page":"e27236","DOI":"10.7759\/cureus.27236","article-title":"Atypical presentation of aortic dissection in a young female and the utility of point-of-care ultrasound in identifying aortic dissection in the emergency department","volume":"14","author":"Kaeley","year":"2022","journal-title":"Cureus"},{"key":"B55","doi-asserted-by":"publisher","first-page":"e78868","DOI":"10.7759\/cureus.78868","article-title":"Emergency medicine faculty utilization of point-of-care ultrasound in the clinical setting","volume":"17","author":"Russell","year":"2025","journal-title":"Cureus"},{"key":"B56","doi-asserted-by":"publisher","first-page":"e36329","DOI":"10.7759\/cureus.36329","article-title":"An interdisciplinary approach to the Introduction of point-of-care ultrasound in an urban academic primary care center","volume":"15","author":"Frasure","year":"2023","journal-title":"Cureus"},{"key":"B57","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s13089-023-00346-1","article-title":"The role of point-of-care ultrasound (POCUS) imaging in clinical outcomes during cardiac arrest: a systematic review","volume":"16","author":"Zaki","year":"2024","journal-title":"Ultrasound J"},{"key":"B58","doi-asserted-by":"publisher","first-page":"64","DOI":"10.52964\/AMJA.0803","article-title":"Gaps in point of care ultrasound provision and the cost of ultrasound equipment provision: results of a nationwide audit of acute medical units","volume":"19","author":"Knight","year":"2020","journal-title":"Acute Med"},{"key":"B59","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1071\/AH23214","article-title":"An economic evaluation of point-of-care ultrasound for children presenting to the emergency department with suspected septic arthritis of the hip","volume":"48","author":"Bailey","year":"2024","journal-title":"Aust Health Rev"},{"key":"B60","doi-asserted-by":"publisher","first-page":"19","DOI":"10.24908\/pocusj.v10i01.18429","article-title":"Evaluation of an international point of care ultrasound (POCUS) training program for internal medicine physicians","volume":"10","author":"Chebly","year":"2025","journal-title":"POCUS J"},{"key":"B61","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1186\/s13089-025-00436-2","article-title":"Clinical obstacles to machine-learning POCUS adoption and system-wide AI implementation (The COMPASS-AI survey)","volume":"17","author":"Wong","year":"2025","journal-title":"Ultrasound J"},{"key":"B62","doi-asserted-by":"publisher","first-page":"53","DOI":"10.37015\/AUDT.2019.190811","article-title":"Artificial intelligence in ultrasound imaging: current research and applications","volume":"3","author":"Wang","year":"2019","journal-title":"Adv Ultrasound Diagn Ther"},{"key":"B63","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1001\/jamacardio.2021.0185","article-title":"Utility of a deep-learning algorithm to guide novices to acquire echocardiograms for limited diagnostic use","volume":"6","author":"Narang","year":"2021","journal-title":"JAMA Cardiol"},{"key":"B64","doi-asserted-by":"publisher","first-page":"7365","DOI":"10.21037\/qims-24-533","article-title":"A deep learning algorithm for the detection of aortic dissection on non-contrast-enhanced computed tomography via the identification and segmentation of the true and false lumens of the aorta","volume":"14","author":"Cheng","year":"2024","journal-title":"Quant Imaging Med Surg"},{"key":"B65","doi-asserted-by":"publisher","first-page":"116","DOI":"10.21037\/atm-24-171","article-title":"Artificial intelligence-powered solutions for automated aortic diameter measurement in computed tomography: a narrative review","volume":"12","author":"Lo","year":"2024","journal-title":"Ann Transl Med"},{"key":"B66","doi-asserted-by":"publisher","first-page":"1146","DOI":"10.1177\/08850666221076041","article-title":"Handheld point-of-care ultrasound: safety considerations for creating guidelines","volume":"37","author":"Hsieh","year":"2022","journal-title":"J Intensive Care Med"},{"key":"B67","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1017\/cem.2015.8","article-title":"International federation for emergency medicine point of care ultrasound curriculum","volume":"17","author":"Atkinson","year":"2015","journal-title":"CJEM"},{"key":"B68","doi-asserted-by":"publisher","first-page":"1516","DOI":"10.1186\/s12909-024-06560-2","article-title":"Competency-based ultrasound curriculum for standardized training resident: a pre- and post-training evaluation","volume":"24","author":"Jiang","year":"2024","journal-title":"BMC Med Educ"},{"key":"B69","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1111\/acem.14839","article-title":"The sonographic protocol for the emergent evaluation of aortic dissections (SPEED protocol): a multicenter, prospective, observational study","volume":"31","author":"Gibbons","year":"2024","journal-title":"Acad Emerg Med"},{"key":"B70","doi-asserted-by":"publisher","first-page":"45","DOI":"10.24908\/pocusj.v10i01.17776","article-title":"Demonstrating feasibility of point of care ultrasound (POCUS)-guided inpatient transthoracic echo triage decision pathway","volume":"10","author":"Conner","year":"2025","journal-title":"POCUS J"},{"key":"B71","doi-asserted-by":"publisher","first-page":"e0304401","DOI":"10.1371\/journal.pone.0304401","article-title":"Diagnostic accuracy of the aortic dissection detection risk score alone or with D-dimer for acute aortic syndromes: systematic review and meta-analysis","volume":"19","author":"Ren","year":"2024","journal-title":"PLoS One"},{"key":"B72","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1016\/S0140-6736(14)61005-9","article-title":"Management of acute aortic dissection","volume":"385","author":"Nienaber","year":"2015","journal-title":"Lancet"},{"key":"B73","doi-asserted-by":"publisher","first-page":"1287","DOI":"10.1002\/jum.15525","article-title":"Telerobotic sonography for remote diagnostic imaging: narrative review of current developments and clinical applications","volume":"40","author":"Adams","year":"2021","journal-title":"J Ultrasound Med"},{"key":"B74","doi-asserted-by":"publisher","first-page":"244","DOI":"10.3389\/fpubh.2019.00244","article-title":"Tele-ultrasound in resource-limited settings: a systematic review","volume":"7","author":"Britton","year":"2019","journal-title":"Front Public Health"},{"key":"B75","doi-asserted-by":"publisher","first-page":"32","DOI":"10.7748\/en.2019.e1916","article-title":"Nursing patients with acute aortic dissection in emergency departments","volume":"27","author":"Wilcox","year":"2019","journal-title":"Emerg Nurse"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1780067\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T05:00:07Z","timestamp":1775019607000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1780067\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,1]]},"references-count":75,"alternative-id":["10.3389\/fcvm.2026.1780067"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2026.1780067","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,1]]},"article-number":"1780067"}}