{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T09:28:04Z","timestamp":1787304484288,"version":"build-2736575974"},"reference-count":36,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T00:00:00Z","timestamp":1787270400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>This study aimed to perform hemodynamic simulations using patient-specific models of abdominal aortic aneurysms (AAA) following endovascular aneurysm repair (EVAR) to investigate the association between energy loss (EL) and Type I endoleak.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Pre- and post-EVAR models were reconstructed from computed tomography angiography (CTA) for four patients with Type I endoleak and four without. Component quantification of EL, along with wall shear stress (WSS)-related hemodynamic parameters, were employed to evaluate the potential of endoleak.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Endoleaks following EVAR tended to occur at the junction of stent grafts, where high time-averaged wall shear stress (TAWSS), high turbulence EL, and high mean flow EL were observed. The turbulence EL values for the main stents, left iliac branch stents, and right iliac branch stents in the endoleak group were 516\u2009\u00b1\u2009183*10\n                      <jats:sup>\u22126<\/jats:sup>\n                      \u2005W, 828\u2009\u00b1\u2009195*10\n                      <jats:sup>\u22126<\/jats:sup>\n                      \u2005W, and 609\u2009\u00b1\u2009193*10\n                      <jats:sup>\u22126<\/jats:sup>\n                      \u2005W, respectively, and the mean flow EL for those regions were 363\u2009\u00b1\u2009125*10\n                      <jats:sup>\u22126<\/jats:sup>\n                      \u2005W, 631\u2009\u00b1\u2009138*10\n                      <jats:sup>\u22126<\/jats:sup>\n                      \u2005W, and 352\u2009\u00b1\u2009162*10\n                      <jats:sup>\u22126<\/jats:sup>\n                      \u2005W, respectively. Compared with the no endoleak group, the endoleak group exhibited significantly higher turbulence EL and mean flow EL at the iliac branch and main stent, whereas no significant difference in TAWSS was found.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Component quantification of EL demonstrated preliminary feasibility for evaluating Type I endoleak in patients with EVAR for AAA, demonstrating greater advantages over WSS-related hemodynamic parameters. This method may provide valuable support for clinicians in assessing surgical prognosis.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fcvm.2026.1849668","type":"journal-article","created":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T09:10:24Z","timestamp":1787303424000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Evaluation of Type I endoleak after endovascular aneurysm repair for abdominal aortic aneurysm using component quantification of energy loss: a preliminary feasibility study"],"prefix":"10.3389","volume":"13","author":[{"given":"Ran","family":"Tao","sequence":"first","affiliation":[{"name":"General Surgery Department, The First Affiliated Hospital of Anhui Medical University","place":["Hefei, China"]},{"name":"General Surgery Department, The Second Affiliated Hospital of Anhui Medical University","place":["Hefei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiming","family":"Liu","sequence":"additional","affiliation":[{"name":"General Surgery Department, The Second Affiliated Hospital of Anhui Medical University","place":["Hefei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weihao","family":"Guo","sequence":"additional","affiliation":[{"name":"General Surgery Department, The First Affiliated Hospital of Anhui Medical University","place":["Hefei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingshang","family":"Kong","sequence":"additional","affiliation":[{"name":"General Surgery Department, The Second Affiliated Hospital of Anhui Medical University","place":["Hefei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenbin","family":"Wang","sequence":"additional","affiliation":[{"name":"General Surgery Department, The Second Affiliated Hospital of Anhui Medical University","place":["Hefei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xudong","family":"Jiang","sequence":"additional","affiliation":[{"name":"General Surgery Department, The Second Affiliated Hospital of Anhui Medical University","place":["Hefei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peng","family":"Wu","sequence":"additional","affiliation":[{"name":"Precision and Intelligence Medical Imaging Lab, Beijing Friendship Hospital, Capital Medical University , .","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yeben","family":"Qian","sequence":"additional","affiliation":[{"name":"General Surgery Department, The First Affiliated Hospital of Anhui Medical University","place":["Hefei, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,8,21]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1016\/j.ejvs.2018.09.020","article-title":"Editor\u2019s choice\u2014European society for vascular surgery (ESVS) 2019 clinical practice guidelines on the management of abdominal aorto-iliac artery aneurysms","volume":"57","author":"Wanhainen","year":"2019","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"B2","doi-asserted-by":"publisher","first-page":"e334","DOI":"10.1161\/CIR.0000000000001106","article-title":"2022 ACC\/AHA guideline for the diagnosis and management of aortic disease: a report of the American Heart Association\/American College of Cardiology joint committee on clinical practice guidelines","volume":"146","author":"Isselbacher","year":"2022","journal-title":"Circulation"},{"key":"B3","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1016\/j.jvs.2013.01.051","article-title":"Ten-year results of endovascular abdominal aortic aneurysm repair from a large multicenter registry","volume":"58","author":"Chang","year":"2013","journal-title":"J Vasc Surg"},{"key":"B4","doi-asserted-by":"publisher","first-page":"2179","DOI":"10.1016\/S0140-6736(05)66627-5","article-title":"Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): randomised controlled trial","volume":"365","year":"2005","journal-title":"Lancet"},{"key":"B5","doi-asserted-by":"publisher","first-page":"7017","DOI":"10.1097\/MS9.0000000000003847","article-title":"Clinical predictors of mortality and endoleak following EVAR and TEVAR","volume":"87","author":"Arin","year":"2025","journal-title":"Ann Med Surg (Lond)"},{"key":"B6","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1016\/j.ejvs.2016.07.086","article-title":"Treatment of a type ia endoleak after EVAR and Iliac branch device with partial proximal stentgraft explantation and dacron graft interposition","volume":"52","author":"Tsilimparis","year":"2016","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"B7","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1016\/j.ejvs.2017.05.008","article-title":"EVAR With flared iliac limbs has a high risk of late type 1b endoleak","volume":"54","author":"Gray","year":"2017","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"B8","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1186\/s41747-024-00489-3","article-title":"Abdominal aneurysm sac thrombus CT density and volume after EVAR: which association with underlying endoleak?","volume":"8","author":"Lembrechts","year":"2024","journal-title":"Eur Radiol Exp"},{"key":"B9","doi-asserted-by":"publisher","first-page":"746","DOI":"10.1016\/j.asjsur.2018.12.006","article-title":"Efficacy of volumetric analysis of aorta as surveillance tool after EVAR","volume":"42","author":"Quan","year":"2019","journal-title":"Asian J Surg"},{"key":"B10","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.ejvs.2016.10.004","article-title":"The long-term durability of intra-operatively placed palmaz stents for the treatment of type ia endoleaks after EVAR of abdominal aortic aneurysm","volume":"53","author":"Abdulrasak","year":"2017","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"B11","doi-asserted-by":"crossref","first-page":"37S","DOI":"10.1016\/j.jvs.2017.03.074","article-title":"IF12. Standard EVAR for aneurysms with large neck diameter results in higher risk of type IA endoleak and rupture","volume":"65","author":"Oliveira","year":"2017","journal-title":"J Vasc Surg"},{"key":"B12","doi-asserted-by":"publisher","first-page":"53","DOI":"10.2147\/VHRM.S81275","article-title":"Type II endoleaks: challenges and solutions","volume":"12","author":"Brown","year":"2016","journal-title":"Vasc Health Risk Manag"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jvs.2024.01.194","article-title":"Rediction of sac enlargement due to type 2 endoleaks after EVAR using CT images and hemodynamic 4D flow MRI analyses","volume":"79","author":"Sano","year":"2024","journal-title":"J Vasc Surg"},{"key":"B14","doi-asserted-by":"publisher","first-page":"7500","DOI":"10.3390\/jcm12237500","article-title":"Oversizing consideration of proximal stent graft in hemodynamically stable and unstable patients undergoing emergent endovascular aortic repair","volume":"12","author":"Qi","year":"2023","journal-title":"J Clin Med"},{"key":"B15","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1016\/j.ejvs.2007.05.022","article-title":"Aneurysm sac pressure after EVAR: the role of endoleak","volume":"34","author":"Hinnen","year":"2007","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"B16","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/j.avsg.2015.08.011","article-title":"Aneurysm sac enlargement after endovascular abdominal aortic aneurysm repair","volume":"31","author":"Dingemans","year":"2016","journal-title":"Ann Vasc Surg"},{"key":"B17","doi-asserted-by":"publisher","first-page":"e0323358","DOI":"10.1371\/journal.pone.0323358","article-title":"Numerical study on the biomechanics mechanism of type II endoleak after EVAR for abdominal aortic aneurysm","volume":"20","author":"Mo","year":"2025","journal-title":"PLoS One"},{"key":"B18","doi-asserted-by":"publisher","first-page":"5712","DOI":"10.3390\/app13095712","article-title":"Computational fluid dynamics (CFD) and finite element analysis (FEM) of a customized stent-graft for endovascular (EVAR) treatment of abdominal aortic aneurism (AAA)","volume":"13","author":"Bologna","year":"2023","journal-title":"Appl Sci"},{"key":"B19","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1186\/s12938-016-0249-z","article-title":"Influence of endoleak positions on the pressure shielding ability of stent-graft after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA)","volume":"15","author":"Li","year":"2016","journal-title":"Biomed Eng Online"},{"key":"B20","doi-asserted-by":"publisher","first-page":"9567294","DOI":"10.1155\/2016\/9567294","article-title":"Endoleak assessment using computational fluid dynamics and image processing methods in stented abdominal aortic aneurysm models","volume":"2016","author":"Lu","year":"2016","journal-title":"Comput Math Methods Med"},{"key":"B21","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1016\/j.avsg.2020.07.014","article-title":"Image-based displacements analysis and computational blood dynamics after endovascular aneurysm repair","volume":"69","author":"Domanin","year":"2020","journal-title":"Ann Vasc Surg"},{"key":"B22","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/j.jmbbm.2018.07.020","article-title":"Fluid-structure interaction (FSI) analysis of stent-graft for aortic endovascular aneurysm repair (EVAR): material and structural considerations","volume":"87","author":"Jayendiran","year":"2018","journal-title":"J Mech Behav Biomed Mater"},{"key":"B23","doi-asserted-by":"publisher","first-page":"795085","DOI":"10.3389\/fphys.2021.795085","article-title":"A comparative study on the hemodynamic performance within cross and non-cross stent-grafts for abdominal aortic aneurysms with an angulated neck","volume":"12","author":"Qing","year":"2021","journal-title":"Front Physiol"},{"key":"B24","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.ejvs.2022.05.027","article-title":"Association between blood flow pattern and rupture risk of abdominal aortic aneurysm based on computational fluid dynamics","volume":"64","author":"Qiu","year":"2022","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"B25","doi-asserted-by":"publisher","first-page":"447","DOI":"10.3390\/bioengineering9090447","article-title":"Fast and accurate computation of the displacement force of stent grafts after endovascular aneurysm repair","volume":"9","author":"Qing","year":"2022","journal-title":"Bioengineering (Basel)"},{"key":"B26","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1161\/01.CIR.101.7.765","article-title":"Assessment of aortic valve stenosis severity: a new index based on the energy loss concept","volume":"101","author":"Garcia","year":"2000","journal-title":"Circulation"},{"key":"B27","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1093\/ehjci\/jeaa010","article-title":"Clinical significance of energy loss index in patients with low-gradient severe aortic stenosis and preserved ejection fraction","volume":"21","author":"Altes","year":"2020","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"B28","doi-asserted-by":"publisher","first-page":"e0151540","DOI":"10.1371\/journal.pone.0151540","article-title":"Turbulent kinetic energy measurement using phase contrast MRI for estimating the post-stenotic pressure drop: in vitro validation and clinical application","volume":"11","author":"Ha","year":"2016","journal-title":"PLoS One"},{"key":"B29","doi-asserted-by":"publisher","first-page":"106826","DOI":"10.1016\/j.cmpb.2022.106826","article-title":"Component quantification of aortic blood flow energy loss using computational fluid-structure interaction hemodynamics","volume":"221","author":"Qiao","year":"2022","journal-title":"Comput Methods Programs Biomed"},{"key":"B30","doi-asserted-by":"publisher","first-page":"1330848","DOI":"10.3389\/fphys.2024.1330848","article-title":"A hemodynamic analysis of energy loss in abdominal aortic aneurysm using three-dimension idealized model","volume":"15","author":"Wang","year":"2024","journal-title":"Front Physiol"},{"key":"B31","doi-asserted-by":"publisher","first-page":"35S","DOI":"10.1016\/j.jvs.2012.07.061","article-title":"Initial findings and potential applicability of computational simulation of the aorta in acute type B dissection","volume":"57","author":"Cheng","year":"2013","journal-title":"J Vasc Surg"},{"key":"B32","doi-asserted-by":"publisher","first-page":"906502","DOI":"10.3389\/fphys.2022.906502","article-title":"A hemodynamic analysis of the thrombosis within occluded coronary arterial fistulas with terminal aneurysms using a blood stasis model","volume":"13","author":"Jiang","year":"2022","journal-title":"Front Physiol"},{"key":"B33","doi-asserted-by":"publisher","first-page":"107785","DOI":"10.1016\/j.cmpb.2023.107785","article-title":"A hemodynamic analysis of fenestrated physician-modified endograft repair for complicated aortic dissections involving the visceral arteries","volume":"242","author":"Jiang","year":"2023","journal-title":"Comput Methods Programs Biomed"},{"key":"B34","doi-asserted-by":"publisher","first-page":"639690","DOI":"10.3389\/fneur.2021.639690","article-title":"A dissipation function-based method for calculating the energy loss of intracranial aneurysms","volume":"12","author":"Mo","year":"2021","journal-title":"Front Neurol"},{"key":"B35","doi-asserted-by":"publisher","first-page":"1082","DOI":"10.1016\/j.jtcvs.2014.06.021","article-title":"Energy loss, a novel biomechanical parameter, correlates with aortic aneurysm size and histopathologic findings","volume":"148","author":"Chung","year":"2014","journal-title":"J Thorac Cardiovasc Surg"},{"key":"B36","doi-asserted-by":"publisher","first-page":"1047","DOI":"10.1016\/j.jmbbm.2021.104736","article-title":"Dependency of energy loss on strain rate, strain magnitude and preload: towards development of a novel biomarker for aortic aneurysm dissection risk","volume":"124","author":"Tang","year":"2021","journal-title":"J Mech Behav Biomed Mater"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1849668\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T09:10:25Z","timestamp":1787303425000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1849668\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,21]]},"references-count":36,"alternative-id":["10.3389\/fcvm.2026.1849668"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2026.1849668","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,21]]},"article-number":"1849668"}}