{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T04:59:26Z","timestamp":1780981166520,"version":"3.54.1"},"reference-count":14,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T00:00:00Z","timestamp":1780963200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Transcatheter left atrial appendage closure (T-LAAC) represents an effective alternative to long-term anticoagulation in patients with atrial fibrillation (AF) and contraindications to oral anticoagulants. Transoesophageal echocardiography (TEE) is the standard imaging modality for procedural guidance, while micro-TEE may allow adequate imaging under conscious sedation, potentially simplifying procedural workflow. This study aimed to evaluate the efficacy and safety of micro-TEE compared with standard TEE guidance during T-LAAC.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Single-center, retrospective study, all consecutive patients undergoing T-LAAC between June 2021 and August 2024. Patients were stratified according to intraprocedural imaging guidance (micro-TEE vs. standard TEE). Baseline characteristics, procedural data, and short-term outcomes were analyzed. A subgroup analysis excluding patients who underwent simultaneous combined atrial fibrillation ablation procedures was performed to reduce confounding.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 47 patients were considered; one was excluded due to poor view in both imaging modalities, for a total of 46 patients. 38 procedures were performed under standard TEE and 8 under micro-TEE guidance. No differences in baseline clinical and echocardiographic characteristics were found. Procedural success was similar, with one failure in the standard TEE group due to the unavailability of the right size of the closure device. No significant differences were observed in periprocedural complications, including mild pericardial effusion, cardiac tamponade, device-related thrombosis, or significant peridevice leak. Micro-TEE guidance was associated with a significantly shorter procedural time (153 vs. 175\u2005min,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.040) and a lower rate of orotracheal intubation, without increases in fluoroscopy time, radiation exposure, or contrast use. This data was confirmed even after considering only isolated T-LAAC procedures, excluding simultaneous combined AF ablation-T-LAAC procedures (143 vs. 160\u2005min,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.042). At 1-month follow-up, the micro-TEE group did not show an increased complication rate.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The use of micro-TEE during T-LAAC procedures did not show a significant difference in procedural success rate and was not associated with an increased complication rate compared with standard TEE guidance. The use of micro-TEE showed a reduction in total procedural time, partly due to the reduced need for OTI, without an increase in radiation exposure, fluoroscopy time, and contrast use.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fcvm.2026.1855910","type":"journal-article","created":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T04:28:14Z","timestamp":1780979294000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Efficacy and safety of transcatheter left atrial appendage closure guided by transoesophageal echocardiography using standard and micro TEE probes: a single-center retrospective study"],"prefix":"10.3389","volume":"13","author":[{"given":"Alessandro","family":"Barbarossa","sequence":"first","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, Cardiovascular Department, Azienda Ospedaliero Universitaria (AOU) Delle Marche","place":["Ancona, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesca","family":"Coraducci","sequence":"additional","affiliation":[{"name":"Cardiology Division-Intensive Cardiac Care Unit, Cardiovascular Department, Azienda Ospedaliero Universitaria (AOU) Delle Marche","place":["Ancona, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elisa","family":"Nicolini","sequence":"additional","affiliation":[{"name":"Interventional Cardiology Unit, Division of Cardiology, Azienda Ospedaliero Universitaria (AOU) Delle Marche , , .","place":["Ancona, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Cipolletta","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, Cardiovascular Department, Azienda Ospedaliero Universitaria (AOU) Delle Marche","place":["Ancona, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandro","family":"Maolo","sequence":"additional","affiliation":[{"name":"Interventional Cardiology Unit, Division of Cardiology, Azienda Ospedaliero Universitaria (AOU) Delle Marche , , .","place":["Ancona, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michela","family":"Casella","sequence":"additional","affiliation":[{"name":"Department of Clinical Sciences, Marche Polytechnic University","place":["Ancona, Italy"]},{"name":"Maria Cecilia Hospital, GVM Care & Research","place":["Cotignola, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabio","family":"Vagnarelli","sequence":"additional","affiliation":[{"name":"Cardiology Division-Intensive Cardiac Care Unit, Cardiovascular Department, Azienda Ospedaliero Universitaria (AOU) Delle Marche","place":["Ancona, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Federico","family":"Guerra","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, Cardiovascular Department, Azienda Ospedaliero Universitaria (AOU) Delle Marche","place":["Ancona, Italy"]},{"name":"Department of Biomedical Sciences and Public Health, Marche Polytechnic University","place":["Ancona, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Marini","sequence":"additional","affiliation":[{"name":"Cardiology Division-Intensive Cardiac Care Unit, Cardiovascular Department, Azienda Ospedaliero Universitaria (AOU) Delle Marche","place":["Ancona, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonio","family":"Dello Russo","sequence":"additional","affiliation":[{"name":"Cardiology and Arrhythmology Clinic, Cardiovascular Department, Azienda Ospedaliero Universitaria (AOU) Delle Marche","place":["Ancona, Italy"]},{"name":"Department of Biomedical Sciences and Public Health, Marche Polytechnic University","place":["Ancona, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tommaso","family":"Piva","sequence":"additional","affiliation":[{"name":"Interventional Cardiology Unit, Division of Cardiology, Azienda Ospedaliero Universitaria (AOU) Delle Marche , , .","place":["Ancona, Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,6,9]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/europace\/euae043","article-title":"2024 European heart rhythm association\/heart rhythm society\/Asia Pacific heart rhythm society\/Latin American heart rhythm society expert consensus statement on catheter and surgical ablation of atrial fibrillation","volume":"26","author":"Tzeis","year":"2024","journal-title":"Europace"},{"key":"B2","doi-asserted-by":"publisher","first-page":"857","DOI":"10.7326\/0003-4819-146-12-200706190-00007","article-title":"Meta-analysis: antithrombotic therapy to prevent stroke in patients who have nonvalvular atrial fibrillation","volume":"146","author":"Hart","year":"2007","journal-title":"Ann. Intern. Med"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0140-6736(13)62343-0","article-title":"Comparison of the efficacy and safety of new oral anticoagulants with warfarin in patients with atrial fibrillation: a meta-analysis of randomized trials","volume":"6736","author":"Ruff","year":"2014","journal-title":"Lancet"},{"key":"B4","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1016\/0003-4975(95)00887-X","article-title":"Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillation","volume":"61","author":"Blackshear","year":"1996","journal-title":"Ann. Thorac. Surg"},{"key":"B5","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1016\/S0140-6736(09)61343-X","article-title":"Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomized non-inferiority trial","volume":"374","author":"Holmes","year":"2009","journal-title":"Lancet"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jacc.2014.04.029","article-title":"Prospective randomized evaluation of the watchman left atrial appendage closure device in patients with atrial fibrillation versus long-term warfarin therapy","volume":"64","author":"Holmes","year":"2014","journal-title":"J. Am. Coll. Cardiol"},{"key":"B7","doi-asserted-by":"publisher","first-page":"2964","DOI":"10.1016\/j.jacc.2017.10.021","article-title":"5-Year outcomes after left atrial appendage closure: from the PREVAIL and PROTECT AF trials","volume":"70","author":"Reddy","year":"2017","journal-title":"J. Am. Coll. Cardiol"},{"key":"B8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jacc.2021.10.023","article-title":"4-year outcomes after left atrial appendage closure versus nonwarfarin oral anticoagulation for atrial fibrillation","volume":"79","author":"Osmancik","year":"2022","journal-title":"JACC"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1056\/NEJMoa2517213","article-title":"Left atrial appendage closure or anticoagulation for atrial fibrillation","volume":"394","author":"Doshi","year":"2026","journal-title":"N. Engl. J. Med"},{"key":"B10","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1016\/j.jacep.2019.11.014","article-title":"Outcomes of routine intracardiac echocardiography to guide left atrial appendage occlusion","volume":"6","author":"Alkhouli","year":"2020","journal-title":"JACC Clin. Electrophysiol"},{"key":"B11","doi-asserted-by":"publisher","first-page":"93","DOI":"10.4244\/EIJ-D-19-00943","article-title":"Transoesophageal echocardiography guidance with paediatric probes in adults undergoing left atrial appendage occlusion","volume":"17","author":"Maarse","year":"2021","journal-title":"EuroIntervention"},{"key":"B12","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1007\/s12471-017-1036-6","article-title":"Feasibility of multiplane microtransoesophageal echocardiographic guidance in structural heart disease transcatheter interventions in adults","volume":"25","author":"Nijenhuis","year":"2017","journal-title":"Netherlands Hear. J"},{"key":"B13","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1016\/j.rec.2018.05.016","article-title":"Minimally-invasive transesophageal echocardiography for left atrial appendage occlusion with a latest-generation microprobe","volume":"72","author":"Jim\u00e9nez Br\u00edtez","year":"2019","journal-title":"Initial Experience. Rev. Espa\u00f1ola Cardiol. (English Ed)"},{"key":"B14","doi-asserted-by":"publisher","first-page":"1091","DOI":"10.1016\/j.jcin.2019.02.027","article-title":"Feasibility, safety, and utility of microtransesophageal echocardiography guidance for percutaneous LAAO under conscious sedation","volume":"12","author":"Barreiro-Perez","year":"2019","journal-title":"JACC Cardiovasc. Interv"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1855910\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T04:28:23Z","timestamp":1780979303000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1855910\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,9]]},"references-count":14,"alternative-id":["10.3389\/fcvm.2026.1855910"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2026.1855910","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,9]]},"article-number":"1855910"}}