{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T05:05:08Z","timestamp":1784610308966,"version":"3.55.0"},"reference-count":54,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:00:00Z","timestamp":1784592000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Pulsed field ablation (PFA) and very high power short duration ablation (vHPSD) are new techniques for catheter ablation of atrial fibrillation that have been rapidly developed in recent years. However, there are still limited high-quality studies on the clinical efficacy and safety of the two methods in the treatment of atrial fibrillation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We searched PubMed, Embase, Wanfang, CNKI and other Chinese and English databases to collect relevant studies on the efficacy and safety of PFA vs. vHPSD in the treatment of AF published up to May 11, 2026. Two researchers independently completed literature screening and data extraction. We used the Newcastle-Ottawa Scale (NOS) and ROBINS-I tool to evaluate the study quality and risk of bias, respectively. Pooled effect sizes were calculated using random-effects models, and meta-regression and sensitivity analyses were conducted to explore heterogeneity and publication bias.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      A total of 11 observational studies involving 1,476 patients were included. Meta-analysis showed that there was no significant difference in the recurrence rate of atrial fibrillation between the PFA group and the vHPSD group during the follow-up period (\n                      <jats:italic>RR<\/jats:italic>\n                      \u2009=\u20090.99, 95%CI: 0.91 to 1.07,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.722). There was no significant difference in the rate of pulmonary vein isolation between the two groups (\n                      <jats:italic>RR<\/jats:italic>\n                      \u2009=\u20091.00, 95%CI: 1.00 to 1.00,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20091.000). In terms of safety outcomes, there was no significant difference in the total incidence of surgery-related complications between the two groups (\n                      <jats:italic>RR<\/jats:italic>\n                      \u2009=\u20090.89, 95%CI: 0.58 to 1.35,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.5353). In the continuous outcomes, there were significant differences in procedure time (\n                      <jats:italic>MD<\/jats:italic>\n                      \u2009=\u2009\u221231.64, 95%CI: \u221240.22 to \u221223.06,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.0001) and fluoroscopy time (\n                      <jats:italic>MD<\/jats:italic>\n                      \u2009=\u20096.93, 95%CI: 4.32\u20139.55,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.0001) between the PFA group and the vHPSD group.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Based on the existing research evidence, this study indicates that there is no significant difference in the efficacy and safety of catheter ablation for atrial fibrillation between pulsed field ablation (PFA) and very high power short duration ablation (vHPSD). The procedure time of the PFA group is shorter than that of the vHPSD group, and the fluoroscopy time is longer than that of the vHPSD group. In view of the small sample size and short follow-up time, more randomized controlled trials with large sample size and long-term follow-up are still needed to further verify the above conclusions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Systematic Review Registration<\/jats:title>\n                    <jats:p>\n                      <jats:ext-link>https:\/\/www.crd.york.ac.uk\/PROSPERO\/view\/CRD420261322321<\/jats:ext-link>\n                      , PROSPERO (Registration ID: CRD420261322321).\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fcvm.2026.1860269","type":"journal-article","created":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T04:20:41Z","timestamp":1784607641000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Efficacy and safety of pulsed field ablation and very high-power short-duration ablation for atrial fibrillation: a meta-analysis"],"prefix":"10.3389","volume":"13","author":[{"given":"Xiujuan","family":"Cao","sequence":"first","affiliation":[{"name":"Department of Cardiology, The Second Hospital of Hebei Medical University","place":["Shijiazhuang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jie","family":"Hao","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Second Hospital of Hebei Medical University","place":["Shijiazhuang, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,7,21]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1093\/eurheartj\/ehaa612","article-title":"2020 ESC guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European association for cardio-thoracic surgery (EACTS)","volume":"42","author":"Hindricks","year":"2021","journal-title":"Eur Heart J"},{"key":"B2","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1161\/CIR.0000000000001193","article-title":"2023 ACC\/AHA\/ACCP\/HRS guideline for the diagnosis and management of atrial fibrillation: a report of the American College of Cardiology\/American Heart Association joint committee on clinical practice guidelines","volume":"149","author":"Joglar","year":"2024","journal-title":"Circulation"},{"key":"B3","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1016\/j.jacc.2014.03.022","article-title":"2014 AHA\/ACC\/HRS guideline for the management of patients with atrial fibrillation","volume":"64","author":"January","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"B4","doi-asserted-by":"publisher","first-page":"e275","DOI":"10.1016\/j.hrthm.2017.05.012","article-title":"2017 HRS\/EHRA\/ECAS\/APHRS\/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation","volume":"14","author":"Calkins","year":"2017","journal-title":"Heart Rhythm"},{"key":"B5","doi-asserted-by":"publisher","first-page":"5","DOI":"10.33963\/v.phj.104486","article-title":"Very high-power short-duration radiofrequency ablation: identifying its place in an electrophysiologist\u2019s armamentarium","volume":"83","author":"Gupta","year":"2025","journal-title":"Pol Heart J"},{"key":"B6","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1016\/j.jacep.2022.10.019","article-title":"Very high-power short-duration, temperature-controlled radiofrequency ablation in paroxysmal atrial fibrillation","volume":"9","author":"Osorio","year":"2023","journal-title":"JACC Clin Electrophysiol"},{"key":"B7","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1016\/j.jacep.2019.04.009","article-title":"Pulmonary vein isolation with very high power, short duration, temperature-controlled lesions","volume":"5","author":"Reddy","year":"2019","journal-title":"JACC Clin Electrophysiol"},{"key":"B8","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1038\/s41569-024-01053-7","article-title":"Pulsed-Field ablation: a revolution in atrial fibrillation therapy","volume":"21","author":"Maizels","year":"2024","journal-title":"Nat Rev Cardiol"},{"key":"B9","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1161\/CIRCULATIONAHA.123.064959","article-title":"Safety and effectiveness of pulsed field ablation to treat atrial fibrillation: one-year outcomes from the MANIFEST-PF registry","volume":"148","author":"Turagam","year":"2023","journal-title":"Circulation"},{"key":"B10","doi-asserted-by":"publisher","first-page":"337","DOI":"10.31083\/j.rcm2411337","article-title":"Pulsed field ablation of atrial fibrillation: a comprehensive review","volume":"24","author":"Matos","year":"2023","journal-title":"Rev Cardiovasc Med"},{"key":"B11","doi-asserted-by":"publisher","first-page":"euae102.729","DOI":"10.1093\/europace\/euae102.729","article-title":"Pulsed field ablation versus very high power short duration radiofrequency ablation in atrial fibrillation: what is better?","volume":"26","author":"Campanelli","year":"2024","journal-title":"Europace"},{"key":"B12","doi-asserted-by":"publisher","first-page":"euae102.165","DOI":"10.1093\/europace\/euae102.165","article-title":"Pulsed field ablation versus very high-power short-duration radiofrequency ablation in persistent atrial fibrillation: a single-centre experience","volume":"26","author":"Cardinali","year":"2024","journal-title":"Europace"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1526","DOI":"10.1016\/j.hrthm.2024.05.042","article-title":"Pulsed field vs very high-power short-duration radiofrequency ablation for atrial fibrillation: results of a multicenter, real-world experience","volume":"21","author":"Dello Russo","year":"2024","journal-title":"Heart Rhythm"},{"key":"B14","doi-asserted-by":"publisher","first-page":"1546","DOI":"10.1016\/j.hroo.2025.07.008","article-title":"Comparison of room times between pulsed-field ablation and very high-power short-duration ablation","volume":"6","author":"Orb\u00e1n","year":"2025","journal-title":"Heart Rhythm O2"},{"key":"B15","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1111\/jce.16157","article-title":"Myocardial injury and inflammation following pulsed-field ablation and very high-power short-duration ablation for atrial fibrillation","volume":"35","author":"Popa","year":"2024","journal-title":"J Cardiovasc Electrophysiol"},{"key":"B16","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-025-02086-9","article-title":"Head-to-Head comparison of pulsed-field ablation, high-power short-duration ablation, cryoballoon and conventional radiofrequency ablation by MRI-based ablation lesion assessment","author":"Regany-Closa","year":"2025","journal-title":"J Interv Card Electrophysiol"},{"key":"B17","doi-asserted-by":"publisher","first-page":"e20240542","DOI":"10.36660\/abc.20240542","article-title":"Abla\u00e7\u00e3o de fibrila\u00e7\u00e3o atrial: eletropora\u00e7\u00e3o versus abla\u00e7\u00e3o por radiofrequ\u00eancia de Alta pot\u00eancia e Curta dura\u00e7\u00e3o","volume":"122","author":"Santos","year":"2025","journal-title":"Arq Bras Cardiol"},{"key":"B18","doi-asserted-by":"publisher","first-page":"2067","DOI":"10.1007\/s10840-024-01853-4","article-title":"Next-Generation atrial fibrillation ablation: clinical performance of pulsed-field ablation and very high-power short-duration radiofrequency","volume":"67","author":"Soubh","year":"2024","journal-title":"J Interv Card Electrophysiol"},{"key":"B19","doi-asserted-by":"publisher","first-page":"540","DOI":"10.1111\/pace.70171","article-title":"Reduced early recurrence after pulmonary vein isolation with pulsed field ablation compared to thermal ablation","volume":"49","author":"Weyand","year":"2026","journal-title":"Pacing Clin Electrophysiol"},{"key":"B20","doi-asserted-by":"publisher","first-page":"2417","DOI":"10.1111\/jce.16101","article-title":"Comparison of pulsed-field ablation versus very high power short duration-ablation for pulmonary vein isolation","volume":"34","author":"W\u00f6rmann","year":"2023","journal-title":"J Cardiovasc Electrophysiol"},{"key":"B21","doi-asserted-by":"crossref","first-page":"A129","DOI":"10.1136\/heartjnl-2024-BCS.123","article-title":"125 Outcomes of patients undergoing elective DC cardioversion for atrial fibrillation: a district general hospital experience","volume-title":"Cardiac Rhythm Management","author":"Abdullah","year":"2024"},{"key":"B22","doi-asserted-by":"publisher","first-page":"1762","DOI":"10.1111\/jce.16728","article-title":"Efficacy and safety of pulsed-field versus high-power short-duration ablation for atrial fibrillation: a systematic review and meta-analysis with reconstructed time-to-event data","volume":"36","author":"Amin","year":"2025","journal-title":"J Cardiovasc Electrophysiol"},{"key":"B23","doi-asserted-by":"publisher","first-page":"e20240845","DOI":"10.36660\/abc.20240845","article-title":"Abla\u00e7\u00e3o por campo pulsado versus abla\u00e7\u00e3o por radiofrequ\u00eancia de Curta dura\u00e7\u00e3o e pot\u00eancia muito Alta na fibrila\u00e7\u00e3o atrial: uma revis\u00e3o sistem\u00e1tica e metan\u00e1lise","volume":"122","author":"Iqbal","year":"2025","journal-title":"Arq Bras Cardiol"},{"key":"B24","doi-asserted-by":"publisher","first-page":"2165","DOI":"10.1111\/jce.16776","article-title":"Pentaspline pulsed field ablation versus high-power short-duration\/very high-power short-duration radiofrequency ablation in atrial fibrillation: a meta-analysis","volume":"36","author":"Mariani","year":"2025","journal-title":"J Cardiovasc Electrophysiol"},{"key":"B25","doi-asserted-by":"publisher","first-page":"e004549","DOI":"10.1161\/JAHA.112.004549","article-title":"Long-term outcomes of catheter ablation of atrial fibrillation: a systematic review and meta-analysis","volume":"2","author":"Ganesan","year":"2013","journal-title":"J Am Heart Assoc"},{"key":"B26","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1016\/j.jacep.2021.01.011","article-title":"The blinding period following ablation therapy for atrial fibrillation","volume":"7","author":"Gottlieb","year":"2021","journal-title":"JACC Clin Electrophysiol"},{"key":"B27","doi-asserted-by":"publisher","first-page":"e006659","DOI":"10.1161\/CIRCEP.118.006659","article-title":"Delayed gadolinium enhancement magnetic resonance imaging detected anatomic gap length in wide circumferential pulmonary vein ablation lesions is associated with recurrence of atrial fibrillation","volume":"11","author":"Linhart","year":"2018","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"B28","doi-asserted-by":"publisher","first-page":"1268","DOI":"10.1016\/j.hroo.2025.06.011","article-title":"Pulsed field ablation vs high-power short duration\/very high-power short duration pulmonary vein isolation\u2014systematic review and meta-analysis with kaplan\u2013meier reconstructed individual patient data","volume":"6","author":"Pranata","year":"2025","journal-title":"Heart Rhythm O2"},{"key":"B29","doi-asserted-by":"publisher","first-page":"1053","DOI":"10.1007\/s10840-025-02033-8","article-title":"Comparing efficacy and safety between pulsed field ablation, cryoballoon ablation and high-power short duration radiofrequency ablation in atrial fibrillation: a systematic review and network meta-analysis","volume":"68","author":"Deepan","year":"2025","journal-title":"J Interv Card Electrophysiol"},{"key":"B30","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1161\/CIRCEP.109.859116","article-title":"Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation","volume":"3","author":"Cappato","year":"2010","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"B31","doi-asserted-by":"publisher","first-page":"958","DOI":"10.1016\/j.jacep.2018.02.019","article-title":"Effect of charge delivery on thromboembolism during radiofrequency ablation in canines","volume":"4","author":"Igel","year":"2018","journal-title":"JACC. Clinical Electrophysiology"},{"key":"B32","doi-asserted-by":"publisher","first-page":"e012854","DOI":"10.1161\/CIRCEP.124.012854","article-title":"Ablating myocardium using nanosecond pulsed electric fields: preclinical assessment of feasibility, safety, and durability","volume":"17","author":"Nies","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"B33","doi-asserted-by":"publisher","first-page":"44442","DOI":"10.31083\/RCM44442","article-title":"Pulse field ablation: an update on energy-specific adverse events","volume":"26","author":"Zhou","year":"2025","journal-title":"Rev Cardiovasc Med"},{"key":"B34","doi-asserted-by":"publisher","first-page":"2089","DOI":"10.1016\/j.jacc.2023.03.418","article-title":"Procedure-Related complications of catheter ablation for atrial fibrillation","volume":"81","author":"Benali","year":"2023","journal-title":"J Am Coll Cardiol"},{"key":"B35","doi-asserted-by":"publisher","first-page":"e13","DOI":"10.15420\/aer.2025.54","article-title":"A review of potential complications of pulsed field ablation for AF: beneath the surface","volume":"15","author":"Ha","year":"2026","journal-title":"Arrhythm Electrophysiol Rev"},{"key":"B36","doi-asserted-by":"publisher","first-page":"3491","DOI":"10.2147\/JIR.S422002","article-title":"Effects of inflammatory cell death caused by catheter ablation on atrial fibrillation","volume":"16","author":"Liu","year":"2023","journal-title":"J Inflamm Res"},{"key":"B37","doi-asserted-by":"publisher","DOI":"10.1097\/CRD.0000000000001117","article-title":"Pulsed field ablation versus high-power short-duration ablation in atrial fibrillation: a systematic and meta-analysis","author":"Malik","year":"2025","journal-title":"Cardiol Rev"},{"key":"B38","doi-asserted-by":"publisher","first-page":"euae251","DOI":"10.1093\/europace\/euae251","article-title":"Intravascular haemolysis and acute kidney injury following atrial fibrillation ablation: a report using two different systems for pulsed field ablation","volume":"26","author":"De Smet","year":"2024","journal-title":"Europace"},{"key":"B39","doi-asserted-by":"publisher","first-page":"46485","DOI":"10.31083\/RCM46485","article-title":"Hemolysis in pulsed field ablation for atrial fibrillation: a narrative review","volume":"27","author":"Cersosimo","year":"2026","journal-title":"Rev Cardiovasc Med"},{"key":"B40","doi-asserted-by":"publisher","first-page":"1911","DOI":"10.1016\/j.hroo.2025.08.042","article-title":"Differential subclinical hemolysis after pulsed field ablation using the FARAPULSE pentaspline catheter vs the PulseSelect circular multi-electrode array catheter","volume":"6","author":"Kuraoka","year":"2025","journal-title":"Heart Rhythm O2"},{"key":"B41","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1007\/s10840-025-02206-5","article-title":"Pulsed field ablation and the risk of hemolysis-driven acute kidney injury: a systematic review and meta-analysis","volume":"69","author":"Barbosa","year":"2025","journal-title":"J Interv Card Electrophysiol"},{"key":"B42","doi-asserted-by":"publisher","first-page":"e012765","DOI":"10.1161\/CIRCEP.124.012765","article-title":"Hemolysis after pulsed field ablation: impact of lesion number and catheter-tissue contact","volume":"17","author":"Nies","year":"2024","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"B43","doi-asserted-by":"publisher","first-page":"e013977","DOI":"10.1161\/CIRCEP.125.013977","article-title":"2025 International expert practical guide on the use of the pentaspline pulsed field ablation system in atrial fibrillation ablation procedures","volume":"18","author":"Chen","year":"2025","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"B44","doi-asserted-by":"publisher","first-page":"e70011","DOI":"10.1002\/joa3.70011","article-title":"Catheter ablation using pulsed-field energy: advantages and limitations compared with conventional energy","volume":"41","author":"Kuroki","year":"2025","journal-title":"J Arrhythm"},{"key":"B45","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1016\/j.hrthm.2025.12.022","article-title":"Pulsed field ablation: disrupting technology in cardiac electrophysiology","volume":"23","author":"Miklav\u010di\u010d","year":"2026","journal-title":"Heart Rhythm"},{"key":"B46","doi-asserted-by":"publisher","first-page":"1569","DOI":"10.1016\/j.hrthm.2025.08.045","article-title":"Beyond the learning curve: how operator experience affects pulsed-field ablation outcomes","volume":"23","author":"Kueffer","year":"2025","journal-title":"Heart Rhythm"},{"key":"B47","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1007\/s10840-025-01981-5","article-title":"Near-Zero fluoroscopy workflow for pulmonary vein isolation in atrial fibrillation using a Variable loop, 3D-integrated circular PFA catheter (VaripulseTM): initial single-center experience with the first 35 patients","volume":"68","author":"Borlich","year":"2025","journal-title":"J Interv Card Electrophysiol"},{"key":"B48","doi-asserted-by":"publisher","first-page":"412","DOI":"10.3390\/jcdd12100412","article-title":"A fluoroscopy-free ablation workflow for persistent atrial fibrillation using a pentaspline pulse field ablation catheter guided by left-sided intracardiac Echo imaging and electroanatomic mapping: a case series","volume":"12","author":"Mohmand-Borkowski","year":"2025","journal-title":"J Cardiovasc Dev Dis"},{"key":"B49","doi-asserted-by":"publisher","first-page":"euaf197","DOI":"10.1093\/europace\/euaf197","article-title":"Outcomes of pulsed-field ablation with low to zero fluoroscopy utilization for atrial fibrillation treatment","volume":"27","author":"Zei","year":"2025","journal-title":"Europace"},{"key":"B50","doi-asserted-by":"publisher","first-page":"900","DOI":"10.1016\/j.jacep.2024.01.017","article-title":"Impact of left atrial posterior wall ablation during pulsed-field ablation for persistent atrial fibrillation","volume":"10","author":"Turagam","year":"2024","journal-title":"JACC Clin Electrophysiol"},{"key":"B51","doi-asserted-by":"publisher","first-page":"euaf012","DOI":"10.1093\/europace\/euaf012","article-title":"Repeat procedures after pulsed field ablation for atrial fibrillation: mANIFEST-REDO study","volume":"27","author":"Scherr","year":"2025","journal-title":"Europace"},{"key":"B52","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1016\/j.hroo.2024.04.011","article-title":"Posterior wall ablation for persistent atrial fibrillation: very-high-power short-duration versus standard-power radiofrequency ablation","volume":"5","author":"Compagnucci","year":"2024","journal-title":"Heart Rhythm O2"},{"key":"B53","doi-asserted-by":"publisher","first-page":"1664","DOI":"10.1016\/j.jacc.2025.03.515","article-title":"Pulsed field ablation for persistent atrial fibrillation","volume":"85","author":"Reddy","year":"2025","journal-title":"J Am Coll Cardiol"},{"key":"B54","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1186\/1471-2288-14-135","article-title":"Estimating the sample mean and standard deviation from the sample size, median, range and\/or interquartile range","volume":"14","author":"Wan","year":"2014","journal-title":"BMC Med Res Methodol"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1860269\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T04:20:43Z","timestamp":1784607643000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1860269\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,21]]},"references-count":54,"alternative-id":["10.3389\/fcvm.2026.1860269"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2026.1860269","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,21]]},"article-number":"1860269"}}