{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T05:03:16Z","timestamp":1784782996745,"version":"3.55.0"},"reference-count":44,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T00:00:00Z","timestamp":1784764800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec>\n                    <jats:title>Background and aims<\/jats:title>\n                    <jats:p>This article aims to develop and validate a methodology for realistic anatomical reconstruction of stented segments from optical coherence tomography (OCT) and angiographic images and the computation of local haemodynamic forces using computational fluid dynamics, towards a more realistic haemodynamic characterisation in coronary atherosclerotic lesions post-PCI.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      Three-dimensional anatomical models of stented vessels (6 silicone models\n                      <jats:italic>in vitro<\/jats:italic>\n                      and 16 patient models) were reconstructed from OCT and angiography, using a new methodology called REFINED, which relies on the separate reconstruction of the lumen and the stent; these two are then fused in a single model. Blood flow simulations were performed using the anatomical models to calculate the endothelial shear stress (ESS) and shear rate (SR). The models were geometrically and haemodynamically evaluated against those reconstructed using conventional models.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The reconstruction error distance was smaller with the REFINED approach than with the conventional approach, in both the silicone and patient models [8 (2\u201315) \u03bcm vs 23 (10\u201354) \u03bcm,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001, and 19 (9\u201332) \u03bcm vs 19 (7\u201336) \u03bcm,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001]. The REFINED method depicted higher ESS at the top of the struts in both the silicone (8.01 (4.21\u201314.92) Pa vs 5.54 (2.96\u20139.63) Pa;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001) and patient models [2.41 (1.41\u20133.65) Pa vs 1.44 (0.77\u20132.52) Pa;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001], and a more spatially heterogeneous SR compared to the conventional approach (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001 for all analyses).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The REFINED approach outperforms the conventional method in reconstructing stent geometry and has been shown to be effective in facilitating a high-fidelity computation of the highly disturbed local haemodynamic environment. This demonstrates its potential role in examining device failure.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fcvm.2026.1863952","type":"journal-article","created":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T04:31:33Z","timestamp":1784781093000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Realistic anatomical model reconstruction and high-fidelity flow computation in stented coronary arteries for the analysis of in-stent thrombosis"],"prefix":"10.3389","volume":"13","author":[{"given":"Ryo","family":"Torii","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, University College London","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amear","family":"Mohammed","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University College London","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mazen","family":"Abou Gamrah","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ibrahim Halil","family":"Tanboga","sequence":"additional","affiliation":[{"name":"Atlas University Medical School, Department of Cardiology and Biostatistics","place":["Istanbul, Turkey"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zaid A.","family":"Abdulelah","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anantharaman","family":"Ramasamy","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust","place":["London, United Kingdom"]},{"name":"William Harvey Research Institute, Queen Mary University London","place":["London, United Kingdom"]},{"name":"Homerton University Hospital, Homerton Healthcare NHS Foundation Trust","place":["United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thamil Kumaran","family":"S. M.","sequence":"additional","affiliation":[{"name":"William Harvey Research Institute, Queen Mary University London","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tingquan","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingwei","family":"He","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tom","family":"Crake","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Janna","family":"Leung","sequence":"additional","affiliation":[{"name":"Medical School, University of Birmingham","place":["Birmingham, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hui Ying","family":"Ang","sequence":"additional","affiliation":[{"name":"National Heart Centre Singapore","place":["Singapore, Singapore"]},{"name":"Duke-NUS Medical School","place":["Singapore, Singapore"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicolas","family":"Foin","sequence":"additional","affiliation":[{"name":"National Heart Centre Singapore","place":["Singapore, Singapore"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaryl","family":"Ng","sequence":"additional","affiliation":[{"name":"National Heart Centre Singapore","place":["Singapore, Singapore"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shawn Lian","family":"Shaoliang","sequence":"additional","affiliation":[{"name":"National Heart Centre Singapore","place":["Singapore, Singapore"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pieter","family":"Kitslaar","sequence":"additional","affiliation":[{"name":"Medis Medical Imaging Systems","place":["Leiden, Netherlands"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jouke","family":"Dijkstra","sequence":"additional","affiliation":[{"name":"Division of Image Processing, Department of Radiology, Leiden University Medical Centre","place":["Leiden, Netherlands"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Moon","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust","place":["London, United Kingdom"]},{"name":"Institute of Cardiovascular Sciences, University College London","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"Baumbach","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust","place":["London, United Kingdom"]},{"name":"William Harvey Research Institute, Queen Mary University London","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christos V.","family":"Bourantas","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Barts Heart Centre, Barts Health NHS Trust","place":["London, United Kingdom"]},{"name":"William Harvey Research Institute, Queen Mary University London","place":["London, United Kingdom"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,7,23]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.ijcard.2022.02.003","article-title":"Stent malapposition generates stent thrombosis: insights from a thrombosis model","volume":"353","author":"Ng","year":"2022","journal-title":"Int J Cardiol"},{"key":"B2","doi-asserted-by":"publisher","first-page":"e0149178","DOI":"10.1371\/journal.pone.0149178","article-title":"Constraining oct with knowledge of device design enables high accuracy hemodynamic assessment of endovascular implants","volume":"11","author":"O'Brien","year":"2016","journal-title":"PLoS One"},{"key":"B3","doi-asserted-by":"publisher","first-page":"407","DOI":"10.4244\/EIJY14M06_11","article-title":"Anatomically correct three-dimensional coronary artery reconstruction using frequency domain optical coherence tomographic and angiographic data: head-to-head comparison with intravascular ultrasound for endothelial shear stress assessment in humans","volume":"11","author":"Papafaklis","year":"2015","journal-title":"EuroIntervention"},{"key":"B4","doi-asserted-by":"publisher","first-page":"3421","DOI":"10.1093\/eurheartj\/ehz551","article-title":"Expert recommendations on the assessment of wall shear stress in human coronary arteries: existing methodologies, technical considerations, and clinical applications","volume":"40","author":"Gijsen","year":"2019","journal-title":"Eur Heart J"},{"key":"B5","doi-asserted-by":"publisher","first-page":"1768","DOI":"10.1161\/CIRCULATIONAHA.105.603050","article-title":"Evidence of a dominant backward-propagating \u201csuction\u201d wave responsible for diastolic coronary filling in humans, attenuated in left ventricular hypertrophy","volume":"113","author":"Davies","year":"2006","journal-title":"Circulation"},{"key":"B6","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1016\/j.jcin.2013.05.034","article-title":"Effect of the endothelial shear stress patterns on neointimal proliferation following drug-eluting bioresorbable vascular scaffold implantation: an optical coherence tomography study","volume":"7","author":"Bourantas","year":"2014","journal-title":"JACC Cardiovasc Interv"},{"key":"B7","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1007\/BF00435088","article-title":"An analytical solution for steady flow of a quemada fluid in a circular tube","volume":"32","author":"Popel","year":"1993","journal-title":"Rheol Acta"},{"key":"B8","volume-title":"Essentials of Veterinary Hematology","author":"Jain","year":"1993"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1417","DOI":"10.1016\/j.neurobiolaging.2014.12.019","article-title":"Hemoglobin, hematocrit, and changes in cerebral blood flow: the second manifestations of arterial disease-magnetic resonance study","volume":"36","author":"van der Veen","year":"2015","journal-title":"Neurobiol Aging"},{"key":"B10","doi-asserted-by":"publisher","first-page":"1089","DOI":"10.1016\/j.jbiomech.2011.01.036","article-title":"The influence of boundary conditions on wall shear stress distribution in patients specific coronary trees","volume":"44","author":"van der Giessen","year":"2011","journal-title":"J Biomech"},{"key":"B11","doi-asserted-by":"publisher","first-page":"H1304","DOI":"10.1152\/ajpheart.00896.2015","article-title":"The impact of scaled boundary conditions on wall shear stress computations in atherosclerotic human coronary bifurcations","volume":"310","author":"Schrauwen","year":"2016","journal-title":"American Journal of Physiology Heart and Circulatory Physiology"},{"key":"B12","doi-asserted-by":"publisher","first-page":"692","DOI":"10.4244\/EIJ-D-18-00529","article-title":"The influence of multidirectional shear stress on plaque progression and composition changes in human coronary arteries","volume":"15","author":"Kok","year":"2019","journal-title":"EuroIntervention"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1016\/j.jcin.2010.08.018","article-title":"The effect of shear stress on neointimal response following sirolimus- and paclitaxel-eluting stent implantation compared with bare-metal stents in humans","volume":"3","author":"Papafaklis","year":"2010","journal-title":"JACC Cardiovasc Interv"},{"key":"B14","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.ijcard.2018.06.065","article-title":"Implications of the local hemodynamic forces on the formation and destabilization of neoatherosclerotic lesions","volume":"272","author":"Torii","year":"2018","journal-title":"Int J Cardiol"},{"key":"B15","doi-asserted-by":"publisher","first-page":"1740","DOI":"10.1161\/01.CIR.103.13.1740","article-title":"Relationship between neointimal thickness and shear stress after wallstent implantation in human coronary arteries","volume":"103","author":"Wentzel","year":"2001","journal-title":"Circulation"},{"key":"B16","doi-asserted-by":"publisher","first-page":"1400","DOI":"10.1161\/CIRCULATIONAHA.110.003210","article-title":"Stent thrombogenicity early in high-risk interventional settings is driven by stent design and deployment and protected by polymer-drug coatings","volume":"123","author":"Kolandaivelu","year":"2011","journal-title":"Circulation"},{"key":"B17","doi-asserted-by":"publisher","first-page":"2231","DOI":"10.1161\/ATVBAHA.117.309728","article-title":"Local hemodynamic forces after stenting: implications on restenosis and thrombosis","volume":"37","author":"Ng","year":"2017","journal-title":"Arterioscler Thromb Vasc Biol"},{"key":"B18","doi-asserted-by":"publisher","first-page":"1525","DOI":"10.1182\/blood.V88.5.1525.1525","article-title":"Platelets and shear stress","volume":"88","author":"Kroll","year":"1996","journal-title":"Blood"},{"key":"B19","doi-asserted-by":"publisher","first-page":"989","DOI":"10.1007\/s00109-006-0101-1","article-title":"The impact of blood rheology on the molecular and cellular events underlying arterial thrombosis","volume":"84","author":"Nesbitt","year":"2006","journal-title":"J Mol Med (Berl)"},{"key":"B20","doi-asserted-by":"publisher","first-page":"1337","DOI":"10.1016\/j.jacc.2011.10.903","article-title":"Role of endothelial shear stress in stent restenosis and thrombosis: pathophysiologic mechanisms and implications for clinical translation","volume":"59","author":"Koskinas","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"B21","doi-asserted-by":"publisher","first-page":"1483","DOI":"10.1007\/s10439-009-9719-9","article-title":"Hemodynamically driven stent strut design","volume":"37","author":"Jimenez","year":"2009","journal-title":"Ann Biomed Eng"},{"key":"B22","doi-asserted-by":"publisher","first-page":"1053","DOI":"10.1016\/j.jbiomech.2007.12.005","article-title":"Effects of different stent designs on local hemodynamics in stented arteries","volume":"41","author":"Balossino","year":"2008","journal-title":"J Biomech"},{"key":"B23","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/1475-925X-8-8","article-title":"Evaluation of the effect of stent strut profile on shear stress distribution using statistical moments","volume":"8","author":"Mejia","year":"2009","journal-title":"Biomed Eng Online"},{"key":"B24","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1093\/ehjci\/jez155","article-title":"The impact of plaque type on strut embedment\/protrusion and shear stress distribution in bioresorbable scaffold","volume":"21","author":"Torii","year":"2020","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"B25","doi-asserted-by":"publisher","first-page":"2570","DOI":"10.1093\/eurheartj\/ehx358","article-title":"Non-Newtonian pulsatile shear stress assessment: a method to differentiate bioresorbable scaffold platforms","volume":"38","author":"Tenekecioglu","year":"2017","journal-title":"Eur Heart J"},{"key":"B26","doi-asserted-by":"publisher","first-page":"1084","DOI":"10.1002\/ccd.27253","article-title":"Hemodynamic analysis of a novel bioresorbable scaffold in porcine coronary artery model","volume":"91","author":"Tenekecioglu","year":"2018","journal-title":"Catheter Cardiovasc Interv"},{"key":"B27","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/j.carrev.2023.11.014","article-title":"Comparison of endothelial shear stress between ultrathin strut bioresorbable polymer drug eluting stent vs durable polymer drug eluting stent post-stent implantation: an optical coherence tomography substudy from bioflow ii","volume":"61","author":"Beyene","year":"2023","journal-title":"Cardiovasc Revasc Med"},{"key":"B28","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1080\/24699322.2017.1389390","article-title":"Fusion of optical coherence tomography and angiography for numerical simulation of hemodynamics in bioresorbable stented coronary artery based on patient-specific model","volume":"22","author":"Huang","year":"2017","journal-title":"Comput Assist Surg (Abingdon)"},{"key":"B29","doi-asserted-by":"publisher","first-page":"1575","DOI":"10.1253\/circj.CJ-17-1332","article-title":"Local flow patterns after implantation of bioresorbable vascular scaffold in coronary bifurcations- novel findings by computational fluid dynamics","volume":"82","author":"Li","year":"2018","journal-title":"Circ J"},{"key":"B30","doi-asserted-by":"publisher","first-page":"e0177495","DOI":"10.1371\/journal.pone.0177495","article-title":"Reconstruction of stented coronary arteries from optical coherence tomography images: feasibility, validation, and repeatability of a segmentation method","volume":"12","author":"Chiastra","year":"2017","journal-title":"PLoS One"},{"key":"B31","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1109\/TMI.2018.2870714","article-title":"Establishment of an automated algorithm utilizing optical coherence tomography and micro-computed tomography imaging to reconstruct the 3-D deformed stent geometry","volume":"38","author":"Elliott","year":"2019","journal-title":"IEEE Trans Med Imaging"},{"key":"B32","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/j.medengphy.2017.06.027","article-title":"A framework for computational fluid dynamic analyses of patient-specific stented coronary arteries from optical coherence tomography images","volume":"47","author":"Migliori","year":"2017","journal-title":"Med Eng Phys"},{"key":"B33","doi-asserted-by":"publisher","first-page":"12252","DOI":"10.1038\/s41598-021-91458-y","article-title":"Three dimensional reconstruction of coronary artery stents from optical coherence tomography: experimental validation and clinical feasibility","volume":"11","author":"Wu","year":"2021","journal-title":"Sci Rep"},{"key":"B34","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1007\/s13239-021-00570-7","article-title":"Semi-Automatic reconstruction of patient-specific stented coronaries based on data assimilation and computer aided design","volume":"13","author":"Lefieux","year":"2022","journal-title":"Cardiovasc Eng Technol"},{"key":"B35","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1016\/j.jcin.2016.01.008","article-title":"Novel 3-dimensional vessel and scaffold reconstruction methodology for the assessment of strut-level wall shear stress after deployment of bioresorbable vascular scaffolds from the absorb iii imaging substudy","volume":"9","author":"Gogas","year":"2016","journal-title":"JACC Cardiovasc Interv"},{"key":"B36","doi-asserted-by":"publisher","first-page":"e0300098","DOI":"10.1371\/journal.pone.0300098","article-title":"Experimental validation and clinical feasibility of 3d reconstruction of coronary artery bifurcation stents using intravascular ultrasound","volume":"19","author":"Wu","year":"2024","journal-title":"PLoS One"},{"key":"B37","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1093\/eurheartj\/ehr409","article-title":"Three-Dimensional optical frequency domain imaging in conventional percutaneous coronary intervention: the potential for clinical application","volume":"34","author":"Farooq","year":"2013","journal-title":"Eur Heart J"},{"key":"B38","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1161\/CIRCINTERVENTIONS.111.965301","article-title":"Vascular tissue reaction to acute malapposition in human coronary arteries: sequential assessment with optical coherence tomography","volume":"5","author":"Gutierrez-Chico","year":"2012","journal-title":"Circ Cardiovasc Interv"},{"key":"B39","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.jcmg.2021.03.008","article-title":"Clinical implications of poststent optical coherence tomographic findings: severe malapposition and cardiac events","volume":"15","author":"Kim","year":"2022","journal-title":"JACC Cardiovasc Imaging"},{"key":"B40","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1016\/s0092-8674(00)80983-6","article-title":"Initiation of platelet adhesion by arrest onto fibrinogen or translocation on Von willebrand factor","volume":"84","author":"Savage","year":"1996","journal-title":"Cell"},{"key":"B41","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1038\/nm.1955","article-title":"A shear gradient-dependent platelet aggregation mechanism drives thrombus formation","volume":"15","author":"Nesbitt","year":"2009","journal-title":"Nat Med"},{"key":"B42","doi-asserted-by":"publisher","first-page":"865","DOI":"10.1016\/s0002-8703(99)70011-6","article-title":"Axial movement of the intravascular ultrasound probe during the cardiac cycle: implications for three-dimensional reconstruction and measurements of coronary dimensions","volume":"138","author":"Arbab-Zadeh","year":"1999","journal-title":"Am Heart J"},{"key":"B43","doi-asserted-by":"publisher","first-page":"962687","DOI":"10.3389\/fbioe.2022.962687","article-title":"Influence of right coronary artery motion, flow pulsatility and non-newtonian rheology on wall shear stress metrics","volume":"10","author":"Kandangwa","year":"2022","journal-title":"Front Bioeng Biotechnol"},{"key":"B44","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1136\/hrt.71.6.572","article-title":"Intravascular ultrasound imaging of angiographically normal coronary arteries: a prospective study in vivo","volume":"71","author":"Ge","year":"1994","journal-title":"Br Heart J"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1863952\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T04:31:43Z","timestamp":1784781103000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1863952\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,23]]},"references-count":44,"alternative-id":["10.3389\/fcvm.2026.1863952"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2026.1863952","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,23]]},"article-number":"1863952"}}