{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T04:51:55Z","timestamp":1791348715580,"version":"4.3.1"},"reference-count":28,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:00:00Z","timestamp":1791331200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>\n                      Arteriovenous fistulas (AVFs) are the preferred vascular access for hemodialysis, but venous stenosis remains a major limitation to long-term patency. Drug-coated balloons (DCBs) have emerged as a promising therapy to inhibit neointimal hyperplasia and reduce restenosis. However, inconsistent clinical outcomes have limited their adoption for AVF stenosis. The unique AVF environment\u2014characterized by high flow, turbulent shear stress, and alternating arterial and venous segments\u2014may influence drug transfer and retention within the vessel wall. Despite its importance, the impact of tissue type under AVF-specific hemodynamics on DCB performance remains poorly understood. This study investigates paclitaxel retention in venous and arterial tissue under simulated AVF conditions using an\n                      <jats:italic>ex vivo<\/jats:italic>\n                      bioreactor system.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>\n                      The IN.PACT\u2122 AV paclitaxel-coated balloon was deployed for 2\u2005min in porcine veins and arteries within an\n                      <jats:italic>ex vivo<\/jats:italic>\n                      AVF-simulating bioreactor. Treated vessel segments were collected at 1- and 24\u2005h to quantify tissue paclitaxel concentration. Scanning electron microscopy (SEM) was performed at 1\u2005h to assess coating deposition on the luminal surface.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Hemodynamic conditions were comparable between venous and arterial groups, confirming physiologically relevant AVF flow and pressure. On log-transformed tissue paclitaxel concentrations, no statistically significant difference was detected between tissue types at either time point (two-way ANOVA,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.163; adjusted geometric mean ratio [vein\/artery]\u2009=\u20092.69, 95% CI: 0.65\u201311.18), and drug levels decreased from 1- to 24\u2005h in both groups. Venous samples exhibited greater variability, particularly at 1\u2005h. SEM analysis revealed heterogeneous coating transfer in both tissues, with clustered deposits in veins and more distributed coverage in arteries.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>\n                      This study establishes an\n                      <jats:italic>ex vivo<\/jats:italic>\n                      platform for mechanistic evaluation of catheter-based drug delivery in vascular access. Under AVF hemodynamics, no statistically significant difference in acute paclitaxel retention was observed between venous and arterial tissues despite structural differences (log-scale two-way ANOVA, adjusted geometric mean ratio [vein\/artery]\u2009=\u20092.69, 95% CI: 0.65\u201311.18). This absence of detectable differences suggests that tissue type alone does not drive DCB performance in AVFs.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fcvm.2026.1888798","type":"journal-article","created":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T04:47:56Z","timestamp":1791348476000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Paclitaxel retention of drug-coated balloons in veins and arteries under arteriovenous fistula hemodynamics"],"prefix":"10.3389","volume":"13","author":[{"given":"Linda B.","family":"Liu","sequence":"first","affiliation":[{"name":"Department of Biomedical Engineering, Wake Forest University School of Medicine","place":["Winston-Salem, NC, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kayla","family":"Lowry","sequence":"additional","affiliation":[{"name":"Department of Engineering, Wake Forest University","place":["Winston-Salem, NC, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brystol","family":"Habermacher","sequence":"additional","affiliation":[{"name":"Department of Engineering, Wake Forest University","place":["Winston-Salem, NC, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saami K.","family":"Yazdani","sequence":"additional","affiliation":[{"name":"Department of Engineering, Wake Forest University","place":["Winston-Salem, NC, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,10,7]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1307","DOI":"10.1001\/jama.2024.0535","article-title":"Arteriovenous access for hemodialysis: a review","volume":"331","author":"Lok","year":"2024","journal-title":"JAMA"},{"key":"B2","doi-asserted-by":"publisher","first-page":"F794","DOI":"10.1152\/ajprenal.00440.2018","article-title":"Arteriovenous conduits for hemodialysis: how to better modulate the pathophysiological vascular response to optimize vascular access durability","volume":"316","author":"Shiu","year":"2019","journal-title":"Am J Physiol Renal Physiol"},{"key":"B3","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1053\/j.ajkd.2019.12.001","article-title":"KDOQI clinical practice guideline for vascular access: 2019 update","volume":"75","author":"Lok","year":"2020","journal-title":"Am J Kidney Dis"},{"key":"B4","doi-asserted-by":"publisher","first-page":"233","DOI":"10.21037\/cdt-22-497","article-title":"Choosing the right treatment for the right lesion, part II: a narrative review of drug-coated balloon angioplasty and its evolving role in dialysis access maintenance","volume":"13","author":"DePietro","year":"2023","journal-title":"Cardiovasc Diagn Ther"},{"key":"B5","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1002\/ccd.24995","article-title":"Vascular, downstream, and pharmacokinetic responses to treatment with a low dose drug-coated balloon in a swine femoral artery model: new DCB assessed in a pig femoral model","volume":"83","author":"Yazdani","year":"2014","journal-title":"Catheter Cardiovasc Interv"},{"key":"B6","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1016\/j.jcin.2015.03.020","article-title":"Impact of paclitaxel dose on tissue pharmacokinetics and vascular healing: a comparative drug-coated balloon study in the familial hypercholesterolemic swine model of superficial femoral in-stent restenosis","volume":"8","author":"Gongora","year":"2015","journal-title":"JACC: Cardiovasc Interv"},{"key":"B7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2019\/9560592","article-title":"Rate of drug coating dissolution determines in-tissue drug retention and durability of biological efficacy","volume":"2019","author":"Granada","year":"2019","journal-title":"J Drug Deliv"},{"key":"B8","volume-title":"IN.PACT","year":"2024"},{"key":"B9","doi-asserted-by":"publisher","first-page":"675188","DOI":"10.3389\/fmedt.2021.675188","article-title":"The development of an ex vivo flow system to assess acute arterial drug retention of cardiovascular intravascular devices","volume":"3","author":"Cooper","year":"2021","journal-title":"Front Med Technol"},{"key":"B10","doi-asserted-by":"publisher","DOI":"10.1111\/1755-5922.12269","article-title":"The use of an occlusion perfusion catheter to deliver paclitaxel to the arterial wall","volume":"35","author":"Atigh","year":"2017","journal-title":"Cardiovasc Ther"},{"key":"B11","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1016\/j.jpba.2017.03.011","article-title":"HPLC\u2013MS\/MS method for quantification of paclitaxel from keratin containing samples","volume":"139","author":"Turner","year":"2017","journal-title":"J Pharm Biomed Anal"},{"key":"B12","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1583\/11-3690.1","article-title":"Paclitaxel-coated balloon angioplasty vs. Plain balloon dilation for the treatment of failing dialysis access:6-month interim results from a prospective randomized controlled trial","volume":"19","author":"Katsanos","year":"2012","journal-title":"J Endovasc Ther"},{"key":"B13","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1007\/s00270-025-04279-1","article-title":"Comparison of drug-coated balloon versus plain balloon angioplasty for the treatment of arteriovenous fistula stenosis: a systematic review and meta-analysis of randomized controlled trials","volume":"49","author":"Xu","year":"2026","journal-title":"Cardiovasc Intervent Radiol"},{"key":"B14","doi-asserted-by":"publisher","first-page":"1470","DOI":"10.3390\/medicina61081470","article-title":"Coronary angioplasty with drug-coated balloons: pharmacological foundations, clinical efficacy, and future directions","volume":"61","author":"Chioncel","year":"2025","journal-title":"Medicina"},{"key":"B15","doi-asserted-by":"publisher","first-page":"1410","DOI":"10.1016\/j.jvs.2013.04.055","article-title":"In vitro hemodynamic model of the arm arteriovenous circulation to study hemodynamics of native arteriovenous fistula and the distal revascularization and interval ligation procedure","volume":"59","author":"Varble","year":"2014","journal-title":"J Vasc Surg"},{"key":"B16","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1007\/s00348-020-03085-4","article-title":"Tomographic PIV analysis of physiological flow conditions in a patient-specific arteriovenous fistula","volume":"61","author":"Gunasekera","year":"2020","journal-title":"Exp Fluids"},{"key":"B17","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1258\/vasc.2011.201204","article-title":"Hemodynamic study of arteriovenous fistulas for hemodialysis access","volume":"21","author":"Chandra","year":"2013","journal-title":"Vascular"},{"key":"B18","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1007\/s13239-017-0311-4","article-title":"Review of experimental modelling in vascular access for hemodialysis","volume":"8","author":"Drost","year":"2017","journal-title":"Cardiovasc Eng Tech"},{"key":"B19","doi-asserted-by":"publisher","first-page":"e10618","DOI":"10.1002\/btm2.10618","article-title":"Design and use of an ex vivo peripheral simulating bioreactor system for pharmacokinetic analysis of a drug coated stent","volume":"9","author":"Chen","year":"2024","journal-title":"Bioeng Transl Med"},{"key":"B20","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.1093\/ndt\/17.6.1057","article-title":"Low-pressure environment and remodelling of the forearm vein in brescia\u2013cimino haemodialysis access","volume":"17","author":"Corpataux","year":"2002","journal-title":"Nephrol Dial Transplant"},{"key":"B21","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1083\/jcb.68.3.705","article-title":"Segmental differentiations of cell junctions in the vascular endothelium. Arteries and veins","volume":"68","author":"Simionescu","year":"1976","journal-title":"J Cell Biol"},{"key":"B22","doi-asserted-by":"publisher","first-page":"826","DOI":"10.1161\/01.RES.0000016672.26000.9E","article-title":"Arterial ultrastructure influences transport of locally delivered drugs","volume":"90","author":"Hwang","year":"2002","journal-title":"Circ Res"},{"key":"B23","doi-asserted-by":"publisher","first-page":"2792","DOI":"10.1021\/bm800571s","article-title":"Effect of extracellular matrix elements on the transport of paclitaxel through an arterial wall tissue mimic","volume":"9","author":"Sirianni","year":"2008","journal-title":"Biomacromolecules"},{"key":"B24","doi-asserted-by":"publisher","first-page":"45","DOI":"10.3390\/bioengineering6020045","article-title":"Tissue level mechanical properties and extracellular matrix investigation of the bovine jugular venous valve tissue","volume":"6","author":"Benson","year":"2019","journal-title":"Bioengineering"},{"key":"B25","doi-asserted-by":"publisher","first-page":"2908","DOI":"10.1007\/s10439-023-03359-y","article-title":"Investigating balloon-vessel contact pressure patterns in angioplasty: in silico insights for drug-coated balloons","volume":"51","author":"Stratakos","year":"2023","journal-title":"Ann Biomed Eng"},{"key":"B26","doi-asserted-by":"publisher","first-page":"H801","DOI":"10.1152\/ajpheart.00294.2025","article-title":"The blueprint: contemporary venous physiology and measurement","volume":"329","author":"Cohen","year":"2025","journal-title":"Am J Physiol Heart Circ Physiol"},{"key":"B27","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1177\/11297298251362928","article-title":"The use of experimental preclinical models in evaluating endovascular interventions for vascular access stenosis: a review","volume":"27","author":"Liu","year":"2025","journal-title":"J Vasc Access"},{"key":"B28","doi-asserted-by":"publisher","first-page":"846","DOI":"10.3389\/fbioe.2020.00846","article-title":"The anastomotic angle of hemodialysis arteriovenous fistula is associated with flow disturbance at the venous stenosis location on angiography","volume":"8","author":"Yang","year":"2020","journal-title":"Front Bioeng Biotechnol"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1888798\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T04:48:05Z","timestamp":1791348485000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1888798\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,7]]},"references-count":28,"alternative-id":["10.3389\/fcvm.2026.1888798"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2026.1888798","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,7]]},"article-number":"1888798"}}