{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T08:23:16Z","timestamp":1787559796770,"version":"build-2736575974"},"reference-count":32,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T00:00:00Z","timestamp":1787529600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:p>Artificial intelligence (AI) applied to the standard 12-lead electrocardiogram (AI-ECG) is being developed as a scalable approach to screen for left ventricular systolic dysfunction (LVSD) and support triage for confirmatory testing. Supervised models trained on paired ECG\u2013echocardiography data show high discrimination for reduced ejection fraction across thresholds and can identify individuals at higher risk of subsequent LV dysfunction despite a normal baseline echocardiogram. External validation of an FDA-cleared ECG-AI device across four geographically diverse U.S. health systems confirmed strong diagnostic accuracy, though signal-format compatibility and quality gating meaningfully affect real-world yield. Two pragmatic randomized trials demonstrate practice-level impact. In primary care, AI-ECG increased the number of new low-ejection-fraction diagnoses and directed echocardiography preferentially to screen-positive patients. In non-cardiology inpatient wards, AI alerts improved diagnostic yield through increased cardiology consultation rather than increased imaging volume. In emergency-department patients with dyspnea, AI-ECG supports a prioritization role with high negative predictive value, outperforming NT-proBNP, but requires confirmatory imaging given prevalence-dependent positive predictive value. In population cohorts, adding AI-ECG signals to PREVENT-HF improves near-term heart-failure risk discrimination and reclassification, though without demonstrated benefit on clinical outcomes such as heart-failure hospitalization or mortality. Foundation models pretrained on large ECG datasets reduce labeled-data requirements and improve transportability, but prospective echocardiography-anchored validation is required before broader deployment. FDA-cleared software is available for left ventricular ejection fraction \u226440% screening from 12-lead ECGs as clinician decision support. This review summarizes performance across thresholds and care settings, outlines threshold selection and calibration, and defines priorities for outcome-oriented trials, equitable deployment, and implementation governance.<\/jats:p>","DOI":"10.3389\/fcvm.2026.1899224","type":"journal-article","created":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T08:14:45Z","timestamp":1787559285000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Artificial intelligence\u2013enabled electrocardiography for assessment of left ventricular systolic dysfunction in the era of foundation models"],"prefix":"10.3389","volume":"13","author":[{"given":"Andreas","family":"Bollmann","sequence":"first","affiliation":[{"name":"Helios Health Institute","place":["Leipzig, Germany"]},{"name":"Fresenius","place":["Bad Homburg, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victoria","family":"Pradler","sequence":"additional","affiliation":[{"name":"Helios Health Institute","place":["Leipzig, Germany"]},{"name":"Medical Faculty, University of Muenster","place":["Muenster, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniela","family":"Husser","sequence":"additional","affiliation":[{"name":"Department of Electrophysiology, Heart Center Leipzig at University of Leipzig","place":["Leipzig, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Igor","family":"Kim","sequence":"additional","affiliation":[{"name":"Helios Health Institute","place":["Leipzig, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sven","family":"Hohenstein","sequence":"additional","affiliation":[{"name":"Helios Health Institute","place":["Leipzig, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne","family":"Nitsche","sequence":"additional","affiliation":[{"name":"Helios Health Institute","place":["Leipzig, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Kwast","sequence":"additional","affiliation":[{"name":"Helios Health Institute","place":["Leipzig, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Olaf","family":"Kannt","sequence":"additional","affiliation":[{"name":"Helios Hospitals","place":["Berlin, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Pawlu","sequence":"additional","affiliation":[{"name":"Helios Hospitals","place":["Berlin, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Moscho","sequence":"additional","affiliation":[{"name":"Fresenius","place":["Bad Homburg, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ralf","family":"Kuhlen","sequence":"additional","affiliation":[{"name":"Helios Health Institute","place":["Leipzig, Germany"]},{"name":"Fresenius","place":["Bad Homburg, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,8,24]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"3272","DOI":"10.1093\/cvr\/cvac013","article-title":"Global burden of heart failure: a comprehensive and updated review of epidemiology","volume":"118","author":"Savarese","year":"2023","journal-title":"Cardiovasc Res"},{"key":"B2","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1038\/s41591-018-0240-2","article-title":"Screening for cardiac contractile dysfunction using an artificial intelligence\u2013enabled electrocardiogram","volume":"25","author":"Attia","year":"2019","journal-title":"Nat Med"},{"key":"B3","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1038\/s41569-020-00503-2","article-title":"Artificial intelligence-enhanced electrocardiography in cardiovascular disease management","volume":"18","author":"Siontis","year":"2021","journal-title":"Nat Rev Cardiol"},{"key":"B4","doi-asserted-by":"publisher","first-page":"990","DOI":"10.1016\/j.jacc.2025.10.065","article-title":"Predicting heart failure from 12-lead ECGs using AI: a HeartShare\/AMP-HF pooled cohort analysis","volume":"87","author":"Desai","year":"2026","journal-title":"JACC"},{"key":"B5","doi-asserted-by":"publisher","first-page":"430","DOI":"10.1161\/CIRCULATIONAHA.123.067626","article-title":"Development and validation of the American Heart Association\u2019s PREVENT equations","volume":"149","author":"Khan","year":"2024","journal-title":"Circulation"},{"key":"B6","doi-asserted-by":"publisher","first-page":"e1006","DOI":"10.1161\/CIR.0000000000001307","article-title":"Risk-based primary prevention of heart failure: a scientific statement from the American Heart Association","volume":"151","author":"Khan","year":"2025","journal-title":"Circulation"},{"key":"B7","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1056\/AIoa2401033","article-title":"An electrocardiogram foundation model built on over 10 million recordings","volume":"2","author":"Li","year":"2025","journal-title":"NEJM AI"},{"key":"B8","doi-asserted-by":"publisher","first-page":"ooaf122","DOI":"10.1093\/jamiaopen\/ooaf122","article-title":"ECG-FM: an open electrocardiogram foundation model","volume":"8","author":"McKeen","year":"2025","journal-title":"JAMIA Open"},{"key":"B9","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1056\/AIoa2500164","article-title":"A foundation transformer model with self-supervised learning for ECG-based assessment of cardiac and coronary function","volume":"2","author":"Moody","year":"2025","journal-title":"NEJM AI"},{"key":"B10","doi-asserted-by":"publisher","first-page":"ehaf1119","DOI":"10.1093\/eurheartj\/ehaf1119","article-title":"Foundation models for electrocardiogram interpretation: clinical implications","volume":"47","author":"Nolin-Lapalme","year":"2026","journal-title":"Eur Heart J"},{"key":"B11","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1007\/s10741-022-10283-1","article-title":"Artificial intelligence enabled ECG screening for left ventricular systolic dysfunction: a systematic review","volume":"28","author":"Bjerk\u00e9n","year":"2022","journal-title":"Heart Fail Rev"},{"key":"B12","doi-asserted-by":"publisher","first-page":"102537","DOI":"10.1016\/j.jacadv.2025.102537","article-title":"Multisite, external validation of an AI-enabled ECG algorithm for detection of low ejection fraction","volume":"5","author":"Carter","year":"2026","journal-title":"JACC Adv"},{"key":"B13","doi-asserted-by":"publisher","first-page":"102572","DOI":"10.1016\/j.jacadv.2025.102572","article-title":"Artificial intelligence\u2013enhanced electrocardiogram models for detection of left ventricular dysfunction","volume":"5","author":"Croon","year":"2026","journal-title":"JACC Adv"},{"key":"B14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41597-022-01899-x","article-title":"MIMIC-IV, a freely accessible electronic health record dataset","volume":"10","author":"Johnson","year":"2023","journal-title":"Sci Data"},{"key":"B15","volume-title":"PhysioNet","author":"Gow","year":"2023"},{"key":"B16","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1038\/s41586-025-09227-0","article-title":"Detecting structural heart disease from electrocardiograms using AI","volume":"644","author":"Poterucha","year":"2025","journal-title":"Nature"},{"key":"B17","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1038\/s41746-023-00840-9","article-title":"A foundational vision transformer improves diagnostic performance for electrocardiograms","volume":"6","author":"Vaid","year":"2023","journal-title":"NPJ Digit Med"},{"key":"B18","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1038\/s41591-021-01335-4","article-title":"Artificial intelligence\u2013enabled electrocardiograms for identification of patients with low ejection fraction: a pragmatic, randomized clinical trial","volume":"27","author":"Yao","year":"2021","journal-title":"Nat Med"},{"key":"B19","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1186\/s12916-025-04190-z","article-title":"Artificial intelligence-assisted diagnosis and prognostication in low ejection fraction using electrocardiograms in inpatient department: a pragmatic randomized controlled trial","volume":"23","author":"Tsai","year":"2025","journal-title":"BMC Med"},{"key":"B20","doi-asserted-by":"publisher","first-page":"e008437","DOI":"10.1161\/CIRCEP.120.008437","article-title":"Artificial intelligence-enabled ECG algorithm to identify patients with left ventricular systolic dysfunction presenting to the emergency department with dyspnea","volume":"13","author":"Adedinsewo","year":"2020","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"B21","doi-asserted-by":"publisher","first-page":"e895","DOI":"10.1161\/CIR.0000000000001063","article-title":"2022 AHA\/ACC\/HFSA guideline for the management of heart failure: a report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines","volume":"145","author":"Heidenreich","year":"2022","journal-title":"Circulation"},{"key":"B22","volume-title":"510(k) Summary: Low Ejection Fraction AI-ECG Algorithm (K232699)","year":"2023"},{"key":"B23","volume-title":"510(k) Summary: Tempus ECG-Low EF (K250119)","year":"2025"},{"key":"B24","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1093\/ehjdh\/ztad081","article-title":"Artificial intelligence-based identification of left ventricular systolic dysfunction from 12-lead electrocardiograms: external validation and advanced application of an existing model","volume":"5","author":"K\u00f6nig","year":"2024","journal-title":"Eur Heart J Digit Health"},{"key":"B25","doi-asserted-by":"publisher","first-page":"100347","DOI":"10.1016\/j.mcpdig.2026.100347","article-title":"Prediction of heart failure with reduced ejection fraction with artificial intelligence electrocardiography in patients with atrial fibrillation","volume":"4","author":"Shropshire","year":"2026","journal-title":"Mayo Clin Proc Digit Health"},{"key":"B26","doi-asserted-by":"publisher","first-page":"4642","DOI":"10.1038\/s41598-025-34911-6","article-title":"Prediction of left ventricular systolic dysfunction in left bundle branch block using a fine-tuned ECG foundation model","volume":"16","author":"Kim","year":"2026","journal-title":"Sci Rep"},{"key":"B27","doi-asserted-by":"publisher","first-page":"118","DOI":"10.3904\/kjim.2025.104","article-title":"Enhanced prediction of left ventricular ejection fraction using electrocardiography with the addition of clinical metadata","volume":"41","author":"Park","year":"2026","journal-title":"Korean J Intern Med"},{"key":"B28","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1093\/ehjdh\/ztad027","article-title":"An explainable artificial intelligence-enabled electrocardiogram analysis model for the classification of reduced left ventricular function","volume":"4","author":"Katsushika","year":"2023","journal-title":"Eur Heart J Digit Health"},{"key":"B29","doi-asserted-by":"publisher","first-page":"e745","DOI":"10.1016\/S2589-7500(21)00208-9","article-title":"The false hope of current approaches to explainable artificial intelligence in health care","volume":"3","author":"Ghassemi","year":"2021","journal-title":"Lancet Digit Health"},{"key":"B30","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.jacc.2024.05.003","article-title":"Transforming cardiovascular care with artificial intelligence: from discovery to practice","volume":"84","author":"Khera","year":"2024","journal-title":"J Am Coll Cardiol"},{"key":"B31","doi-asserted-by":"publisher","first-page":"13502","DOI":"10.1038\/s41598-025-97113-0","article-title":"AI Analysis for ejection fraction estimation from 12-lead ECG","volume":"15","author":"Devkota","year":"2025","journal-title":"Sci Rep"},{"key":"B32","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1001\/jamacardio.2025.0492","article-title":"Artificial intelligence\u2013enabled prediction of heart failure risk from single-lead electrocardiograms","volume":"10","author":"Dhingra","year":"2025","journal-title":"JAMA Cardiol"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1899224\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T08:14:50Z","timestamp":1787559290000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1899224\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,24]]},"references-count":32,"alternative-id":["10.3389\/fcvm.2026.1899224"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2026.1899224","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,24]]},"article-number":"1899224"}}