{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,5]],"date-time":"2026-08-05T05:52:49Z","timestamp":1785909169666,"version":"3.56.0"},"reference-count":26,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,8,5]],"date-time":"2026-08-05T00:00:00Z","timestamp":1785888000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002855","name":"Ministry of Science and Technology of the People's Republic of China","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002855","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Cardiovasc. Med."],"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>The relationship between annular eccentricity and paravalvular leak (PVL) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) patients remains insufficiently defined, particularly for Chinese self-expanding valve platforms. This study evaluated the association between the CT-derived eccentricity index (EI) and initial post-deployment moderate-or-greater PVL after self-expanding TAVR in BAV patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We retrospectively analyzed 194 consecutive BAV patients who underwent TAVR with the first-generation self-expanding VenusA valve. The primary endpoint was moderate-or-greater PVL assessed immediately after valve release and before corrective maneuvers such as post-dilatation. EI was measured by two independent observers with excellent interobserver agreement (ICC\u2009=\u20090.943). Multivariable logistic regression, ROC analysis, sensitivity analyses, and bootstrap internal validation were performed. NRI and IDI were analyzed as secondary measures of incremental information.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Initial post-deployment moderate-or-greater PVL occurred in 62 patients (32.0%). Although EI was modestly higher in patients with moderate-or-greater PVL than in those with no\/mild PVL (median 0.23 [IQR 0.19\u20130.26] vs. 0.20 [0.17\u20130.25];\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.005), its stand-alone discrimination was poor (AUC\u2009=\u20090.625; 95% CI 0.539\u20130.711). After adjustment for clinical and anatomical covariates, EI \u22650.19 remained independently associated with moderate-or-greater PVL (OR\u2009=\u20092.99; 95% CI 1.44\u20136.23;\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.0034), whereas semi-quantitative leaflet calcification and raphe calcification were not. Adding EI increased the C-index only marginally (apparent 0.572 \u2192 0.666; optimism-corrected 0.609), indicating limited overall model discrimination. Predischarge transesophageal echocardiography was available for all 194 patients: moderate-or-greater PVL fell from 62 patients (32.0%) at deployment to only 6 (3.1%) at predischarge, and 57 of the 62 patients with initial moderate-or-greater PVL (91.9%) had regressed to mild or less (paired Wilcoxon signed-rank,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&amp;lt;\u20090.001), underscoring that initial post-deployment PVL does not equate to clinically relevant residual PVL.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In BAV patients undergoing TAVR with the first-generation self-expanding VenusA valve, EI \u22650.19 was independently associated with initial post-deployment moderate-or-greater PVL, but its stand-alone and model-level discriminative performance were limited. EI should be considered a supplementary dimension in integrated preprocedural risk assessment rather than an isolated decision-making criterion.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fcvm.2026.1909489","type":"journal-article","created":{"date-parts":[[2026,8,5]],"date-time":"2026-08-05T05:41:22Z","timestamp":1785908482000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Association between annular eccentricity and initial post-deployment paravalvular leak before corrective maneuvers in bicuspid aortic valve patients undergoing self-expanding transcatheter aortic valve replacement: a single-center retrospective study"],"prefix":"10.3389","volume":"13","author":[{"given":"Chen","family":"Cui","sequence":"first","affiliation":[{"name":"Department of Cardiovascular Surgery, Affiliated Hospital of Qingdao University","place":["Qingdao, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhanjun","family":"Qu","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Affiliated Hospital of Qingdao University","place":["Qingdao, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ze","family":"Zhao","sequence":"additional","affiliation":[{"name":"Department of Radiology, Qingdao Eighth People\u2019s Hospital","place":["Qingdao, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weili","family":"Liu","sequence":"additional","affiliation":[{"name":"Interventional Operation Room, Affiliated Hospital of Qingdao University","place":["Qingdao, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lei","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Surgery, Affiliated Hospital of Qingdao University","place":["Qingdao, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,8,5]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1136\/heart.83.1.81","article-title":"Clinical significance of the bicuspid aortic valve","volume":"83","author":"Ward","year":"2000","journal-title":"Heart"},{"key":"B2","doi-asserted-by":"publisher","first-page":"E88","DOI":"10.1002\/ccd.25948","article-title":"Aortic annulus and root characteristics in severe aortic stenosis due to bicuspid aortic valve and tricuspid aortic valves: implications for transcatheter aortic valve therapies","volume":"86","author":"Philip","year":"2015","journal-title":"Catheter Cardiovasc Interv"},{"key":"B3","doi-asserted-by":"publisher","first-page":"2579","DOI":"10.1016\/j.jacc.2017.03.017","article-title":"Outcomes in transcatheter aortic valve replacement for bicuspid versus tricuspid aortic valve stenosis","volume":"69","author":"Yoon","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"B4","doi-asserted-by":"publisher","first-page":"1585","DOI":"10.1016\/j.jacc.2013.01.047","article-title":"Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature","volume":"61","author":"Athappan","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"B5","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1093\/eurheartj\/ehu384","article-title":"Paravalvular regurgitation after transcatheter aortic valve replacement with the edwards SAPIEN valve in the PARTNER trial: characterizing patients and impact on outcomes","volume":"36","author":"Kodali","year":"2015","journal-title":"Eur Heart J"},{"key":"B6","doi-asserted-by":"publisher","first-page":"2193","DOI":"10.1001\/jama.2019.7108","article-title":"Association between transcatheter aortic valve replacement for bicuspid vs tricuspid aortic stenosis and mortality or stroke","volume":"321","author":"Makkar","year":"2019","journal-title":"JAMA"},{"key":"B7","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1016\/j.jcin.2019.08.035","article-title":"Three generations of self-expanding transcatheter aortic valves: a report from the STS\/ACC TVT registry","volume":"13","author":"Forrest","year":"2020","journal-title":"JACC Cardiovasc Interv"},{"key":"B8","doi-asserted-by":"publisher","first-page":"1652","DOI":"10.1016\/j.jcin.2024.05.002","article-title":"Incidence, predictors, and outcomes of paravalvular regurgitation after TAVR in sievers type 1 bicuspid aortic valves","volume":"17","author":"Zito","year":"2024","journal-title":"JACC Cardiovasc Interv"},{"key":"B9","doi-asserted-by":"publisher","first-page":"1268","DOI":"10.3390\/jcm15031268","article-title":"Cardiovascular CT in bicuspid aortic valve disease: a state-of-the-art narrative review of advances, clinical integration, and future directions","volume":"15","author":"Jawed","year":"2026","journal-title":"J Clin Med"},{"key":"B10","first-page":"190","article-title":"Relationship of aortic annular eccentricity and paravalvular regurgitation post transcatheter aortic valve implantation with CoreValve","volume":"25","author":"Wong","year":"2013","journal-title":"J Invasive Cardiol"},{"key":"B11","doi-asserted-by":"publisher","first-page":"908","DOI":"10.1016\/j.jacc.2012.11.055","article-title":"Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography","volume":"61","author":"Jilaihawi","year":"2013","journal-title":"J Am Coll Cardiol"},{"key":"B12","doi-asserted-by":"publisher","first-page":"977","DOI":"10.1002\/ccd.25005","article-title":"Three-dimensional multidetector computed tomography versus conventional 2-dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: influence on postprocedural paravalvular aortic regurgitation","volume":"82","author":"Hansson","year":"2013","journal-title":"Catheter Cardiovasc Interv"},{"key":"B13","doi-asserted-by":"publisher","first-page":"1623","DOI":"10.1016\/j.jacc.2010.06.035","article-title":"Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the medtronic CoreValve bioprosthesis","volume":"56","author":"Sherif","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"B14","doi-asserted-by":"publisher","first-page":"1170979","DOI":"10.3389\/fcvm.2023.1170979","article-title":"Quantity and location of aortic valve calcification predicts paravalvular leakage after transcatheter aortic valve replacement: a systematic review and meta-analysis","volume":"10","author":"Shi","year":"2023","journal-title":"Front Cardiovasc Med"},{"key":"B15","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1080\/24748706.2017.1398437","article-title":"Severe symptomatic bicuspid and tricuspid aortic stenosis in China: characteristics and outcomes of transcatheter aortic valve replacement with the Venus-A valve","volume":"2","author":"Song","year":"2018","journal-title":"Struct Heart"},{"key":"B16","doi-asserted-by":"publisher","first-page":"1725106","DOI":"10.3389\/fcvm.2026.1725106","article-title":"Efficacy and safety of a Venus A valve among Chinese patients undergoing transcatheter aortic valve replacement: a systematic review and single-arm meta-analysis","volume":"13","author":"Sun","year":"2026","journal-title":"Front Cardiovasc Med"},{"key":"B17","doi-asserted-by":"publisher","first-page":"1169590","DOI":"10.3389\/fcvm.2023.1169590","article-title":"Transcatheter aortic valve replacement with the VenusA-pro and VenusA-plus systems: preliminary experience in China","volume":"10","author":"Li","year":"2023","journal-title":"Front Cardiovasc Med"},{"key":"B18","doi-asserted-by":"publisher","first-page":"1012","DOI":"10.1097\/CM9.0000000000003082","article-title":"Transcatheter aortic valve replacement: a journey of two decades and beyond","volume":"137","author":"Xiong","year":"2024","journal-title":"Chin Med J (Engl)"},{"key":"B19","doi-asserted-by":"publisher","first-page":"4635","DOI":"10.1093\/eurheartj\/ehaf194","article-title":"2025 ESC\/EACTS guidelines for the management of valvular heart disease","volume":"46","author":"Praz","year":"2025","journal-title":"Eur Heart J"},{"key":"B20","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J Chiropr Med"},{"key":"B21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jcct.2018.11.008","article-title":"Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI)\/transcatheter aortic valve replacement (TAVR): an expert consensus document of the society of cardiovascular computed tomography","volume":"13","author":"Blanke","year":"2019","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"B22","doi-asserted-by":"publisher","first-page":"130","DOI":"10.3390\/jcdd12040130","article-title":"Paravalvular leak in transcatheter aortic valve implantation: a review of current challenges and future directions","volume":"12","author":"Synetos","year":"2025","journal-title":"J Cardiovasc Dev Dis"},{"key":"B23","doi-asserted-by":"publisher","first-page":"e005987","DOI":"10.1161\/CIRCIMAGING.117.005987","article-title":"Bicuspid aortic valve: what to image in patients considered for transcatheter aortic valve replacement?","volume":"10","author":"Kong","year":"2017","journal-title":"Circ Cardiovasc Imaging"},{"key":"B24","doi-asserted-by":"publisher","first-page":"1470","DOI":"10.1016\/j.amjcard.2011.07.007","article-title":"Location and severity of aortic valve calcium and implications for aortic regurgitation after transcatheter aortic valve implantation","volume":"108","author":"Ewe","year":"2011","journal-title":"Am J Cardiol"},{"key":"B25","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1016\/j.jcin.2012.02.010","article-title":"Predictive factors, efficacy, and safety of balloon post-dilation after transcatheter aortic valve implantation with a balloon-expandable valve","volume":"5","author":"Nombela-Franco","year":"2012","journal-title":"JACC Cardiovasc Interv"},{"key":"B26","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1161\/CIRCULATIONAHA.113.002947","article-title":"Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement","volume":"128","author":"Barbanti","year":"2013","journal-title":"Circulation"}],"container-title":["Frontiers in Cardiovascular Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1909489\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,5]],"date-time":"2026-08-05T05:41:23Z","timestamp":1785908483000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fcvm.2026.1909489\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,5]]},"references-count":26,"alternative-id":["10.3389\/fcvm.2026.1909489"],"URL":"https:\/\/doi.org\/10.3389\/fcvm.2026.1909489","relation":{},"ISSN":["2297-055X"],"issn-type":[{"value":"2297-055X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,5]]},"article-number":"1909489"}}