{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T02:44:08Z","timestamp":1791945848405,"version":"4.3.4"},"reference-count":139,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,5,22]],"date-time":"2023-05-22T00:00:00Z","timestamp":1684713600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Endocrinol."],"abstract":"<jats:p>The accurate detection of parathyroid glands (PGs) during surgery is of great significance in thyroidectomy and parathyroidectomy, which protects the function of normal PGs to prevent postoperative hypoparathyroidism and the thorough removal of parathyroid lesions. Existing conventional imaging techniques have certain limitations in the real-time exploration of PGs. In recent years, a new, real-time, and non-invasive imaging system known as the near-infrared autofluorescence (NIRAF) imaging system has been developed to detect PGs. Several studies have confirmed that this system has a high parathyroid recognition rate and can reduce the occurrence of transient hypoparathyroidism after surgery. The NIRAF imaging system, like a magic mirror, can monitor the PGs during surgery in real time, thus providing great support for surgeries. In addition, the NIRAF imaging system can evaluate the blood supply of PGs by utilizing indocyanine green (ICG) to guide surgical strategies. The NIRAF imaging system and ICG complement each other to protect normal parathyroid function and reduce postoperative complications. This article reviews the effectiveness of the NIRAF imaging system in thyroidectomies and parathyroidectomies and briefly discusses some existing problems and prospects for the future.<\/jats:p>","DOI":"10.3389\/fendo.2023.1160902","type":"journal-article","created":{"date-parts":[[2023,5,22]],"date-time":"2023-05-22T00:53:17Z","timestamp":1684716797000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":5,"title":["The magic mirror: a novel intraoperative monitoring method for parathyroid glands"],"prefix":"10.3389","volume":"14","author":[{"given":"Yue","family":"Yuan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Bao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mingmei","family":"Huangfu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2023,5,22]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","DOI":"10.1016\/j.oraloncology.2018.11.011","article-title":"Parathyroid gland management using optical technologies during thyroidectomy or parathyroidectomy: a systematic review","volume":"87","author":"Abbaci","year":"2018","journal-title":"Oral Oncol"},{"key":"B2","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1007\/s00423-018-1665-2","article-title":"Enhanced visualization of parathyroid glands during video-assisted neck surgery","volume":"403","author":"Alesina","year":"2018","journal-title":"Langenbecks Arch Surg"},{"key":"B3","doi-asserted-by":"publisher","DOI":"10.1089\/thy.2017.0309","article-title":"American Thyroid association statement on postoperative hypoparathyroidism: diagnosis, prevention, and management in adults","volume":"28","author":"Orloff","year":"2018","journal-title":"Thyroid"},{"key":"B4","doi-asserted-by":"publisher","DOI":"10.1001\/jamasurg.2019.4613","article-title":"Association of autofluorescence-based detection of the parathyroid glands during total thyroidectomy with postoperative hypocalcemia risk","volume":"155","author":"Fares Benmiloud","year":"2022","journal-title":"Cancer Commun"},{"key":"B5","doi-asserted-by":"publisher","DOI":"10.1590\/2175-8239-jbn-3924","article-title":"Initial surgical results of 500 parathyroidectomies for hyperparathyroidism related to chronic kidney disease - mineral and bone disorder","volume":"40","author":"Neves","year":"2018","journal-title":"J Bras Nefrol"},{"key":"B6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jamcollsurg.2016.04.049","article-title":"Cutting edge in thyroid surgery: autofluorescence of parathyroid glands","volume":"223","author":"Falco","year":"2016","journal-title":"J Am Coll Surgeons"},{"key":"B7","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2020.09.014","article-title":"Current state of intraoperative use of near infrared fluorescence for parathyroid identification and preservation","volume":"169","author":"Solorzano","year":"2021","journal-title":"Surgery"},{"key":"B8","doi-asserted-by":"publisher","first-page":"23","DOI":"10.21873\/invivo.11741","article-title":"Intraoperative indocyanine green (ICG) angiography for the identification of the parathyroid glands: current evidence and future perspectives","volume":"34","author":"Spartalis","year":"2020","journal-title":"Vivo"},{"key":"B9","doi-asserted-by":"publisher","DOI":"10.1136\/jcp.2002.002550","article-title":"Best practice no 183. examination of parathyroid gland specimens","volume":"58","author":"Johnson","year":"2005","journal-title":"J Clin Pathol"},{"key":"B10","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2265.2002.01583.x","article-title":"Ultrasonography for preoperative localization of enlarged parathyroid glands in primary hyperparathyroidism: comparison with (99m)technetium sestamibi scintigraphy","volume":"57","author":"Haber","year":"2002","journal-title":"Clin Endocrinol (Oxf)"},{"key":"B11","doi-asserted-by":"publisher","DOI":"10.1067\/msy.2000.109963","article-title":"Ultrasound and sestamibi scan as the only preoperative imaging tests in reoperation for parathyroid adenomas","volume":"128","author":"Feingold","year":"2000","journal-title":"Surgery"},{"key":"B12","doi-asserted-by":"publisher","DOI":"10.1002\/jso.24240","article-title":"The utility of indocyanine green near infrared fluorescent imaging in the identification of parathyroid glands during surgery for primary hyperparathyroidism","volume":"113","author":"Zaidi","year":"2016","journal-title":"J Surg Oncol"},{"key":"B13","doi-asserted-by":"publisher","DOI":"10.1007\/s11547-018-0970-8","article-title":"MRI Findings and utility of DWI in the evaluation of solid parathyroid lesions","volume":"124","author":"Yildiz","year":"2019","journal-title":"Radiol Med"},{"key":"B14","doi-asserted-by":"publisher","DOI":"10.1245\/s10434-018-6367-z","article-title":"4D-CT is superior to ultrasound and sestamibi for localizing recurrent parathyroid disease","volume":"25","author":"Hamidi","year":"2018","journal-title":"Ann Surg Oncol"},{"key":"B15","doi-asserted-by":"publisher","DOI":"10.1148\/rg.2020190190","article-title":"Parathyroid 4D CT: what the surgeon wants to know","volume":"40","author":"Bunch","year":"","journal-title":"Radiographics"},{"key":"B16","doi-asserted-by":"publisher","DOI":"10.1002\/hed.20416","article-title":"Adverse neurologic effect of methylene blue used during parathyroidectomy","volume":"28","author":"Patel","year":"2006","journal-title":"Head Neck"},{"key":"B17","doi-asserted-by":"publisher","first-page":"3538","DOI":"10.3390\/jcm9113538","article-title":"Methylene blue-current knowledge, fluorescent properties, and its future use","volume":"9","author":"Cwalinski","year":"2020","journal-title":"J Clin Med"},{"key":"B18","doi-asserted-by":"publisher","DOI":"10.1002\/lary.21857","article-title":"Intraoperative photodynamic detection of normal parathyroid glands using 5-aminolevulinic acid","volume":"121","author":"Suzuki","year":"2011","journal-title":"Laryngoscope"},{"key":"B19","doi-asserted-by":"publisher","DOI":"10.1272\/jnms.81.84","article-title":"Identification of pathological and normal parathyroid tissue by fluorescent labeling with 5-aminolevulinic acid during endocrine neck surgery","volume":"81","author":"Takeuchi","year":"2014","journal-title":"J Nippon Med Sch"},{"key":"B20","doi-asserted-by":"publisher","DOI":"10.5858\/2003-127-64-IPAPTI","article-title":"Interpretative problems and preparative technique influence reliability of intraoperative parathyroid touch imprints","volume":"127","author":"Yao","year":"2003","journal-title":"Arch Pathol Lab Med"},{"key":"B21","doi-asserted-by":"publisher","DOI":"10.21037\/gs.2016.10.06","article-title":"Indocyanine green-enhanced fluorescence for assessing parathyroid perfusion during thyroidectomy","volume":"5","author":"Lavazza","year":"2016","journal-title":"Gland Surg"},{"key":"B22","doi-asserted-by":"publisher","DOI":"10.1111\/1754-9485.13330","article-title":"Diagnosis and localization of parathyroid adenomas using 16-slice SPECT\/CT: a clinicopathological correlation","volume":"66","author":"Sankaran","year":"2022","journal-title":"J Med Imaging Radiat Oncol"},{"key":"B23","article-title":"[Modern diagnostic orientations on parathyroid adenomas]","volume":"56","author":"Lacroix","year":"1965","journal-title":"Minerva Med"},{"key":"B24","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-197701000-00005","article-title":"Computed tomography for parathyroid localization","volume":"1","author":"Doppman Jl Fau - Brennan","year":"1977","journal-title":"J Comput Assist Tomogr"},{"key":"B25","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.150.2.6691101","article-title":"Magnetic resonance imaging of the neck. part II: pathologic findings","volume":"150","author":"Stark Dd Fau - Moss","year":"1984","journal-title":"Radiology"},{"key":"B26","doi-asserted-by":"publisher","DOI":"10.1097\/00006231-198911000-00003","article-title":"99Tcm sestamibi\u2013a new agent for parathyroid imaging","volume":"10","author":"Coakley","year":"1989","journal-title":"Nucl Med Commun"},{"key":"B27","doi-asserted-by":"publisher","first-page":"067012","DOI":"10.1117\/1.3583571","article-title":"Near-infrared autofluorescence for the detection of parathyroid glands","volume":"16","author":"Paras","year":"2011","journal-title":"J BioMed Opt"},{"key":"B28","doi-asserted-by":"publisher","DOI":"10.1016\/j.path.2019.08.006","article-title":"Parathyroid pathology","volume":"12","author":"Guilmette","year":"2019","journal-title":"Surg Pathol Clin"},{"key":"B29","doi-asserted-by":"publisher","first-page":"230","DOI":"10.3978\/j.issn.2305-5839.2015.08.20","article-title":"Expert consensus statement on parathyroid protection in thyroidectomy","volume":"3","author":"Zhu","year":"2015","journal-title":"Ann Transl Med"},{"key":"B30","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-197603000-00010","article-title":"The anatomic basis of parathyroid surgery","volume":"183","author":"Wang","year":"1976","journal-title":"Ann Surg"},{"key":"B31","doi-asserted-by":"publisher","DOI":"10.1016\/j.rcl.2011.02.009","article-title":"Parathyroid imaging","volume":"49","author":"Johnson","year":"2011","journal-title":"Radiol Clin North Am"},{"key":"B32","doi-asserted-by":"publisher","DOI":"10.1016\/j.rcl.2020.07.006","article-title":"Parathyroid imaging","volume":"58","author":"Itani","year":"2020","journal-title":"Radiol Clin North Am"},{"key":"B33","doi-asserted-by":"publisher","DOI":"10.1007\/s12565-012-0142-1","article-title":"Location, number and morphology of parathyroid glands: results from a large anatomical series","volume":"87","author":"Lappas","year":"2012","journal-title":"Anat Sci Int"},{"key":"B34","doi-asserted-by":"publisher","DOI":"10.3389\/fendo.2021.760419","article-title":"Parathyroid imaging: past, present, and future","volume":"12","author":"Morris","year":"2021","journal-title":"Front Endocrinol (Lausanne)"},{"key":"B35","doi-asserted-by":"publisher","DOI":"10.1007\/s00292-018-0467-1","article-title":"[Ectopic tissue of the thyroid gland and the parathyroid glands]","volume":"39","author":"Theurer","year":"2018","journal-title":"Pathologe"},{"key":"B36","doi-asserted-by":"publisher","DOI":"10.1055\/s-0032-1327628","article-title":"Ectopic parathyroid glands and their anatomical, clinical and surgical implications","volume":"120","author":"Noussios","year":"2012","journal-title":"Exp Clin Endocrinol Diabetes"},{"key":"B37","doi-asserted-by":"publisher","DOI":"10.4158\/EP-2018-0003","article-title":"Imaging localization and surgical approach in the management of ectopic parathyroid adenomas","volume":"24","author":"Parikh Am Fau - Suliburk","year":"2018","journal-title":"Endocr Pract"},{"key":"B38","doi-asserted-by":"publisher","DOI":"10.1007\/BF02439553","article-title":"Localization of ectopic parathyroid glands using technetium-99m sestamibi imaging: comparison with magnetic resonance and computed tomographic imaging","volume":"24","author":"Ishibashi","year":"1997","journal-title":"Eur J Nucl Med"},{"key":"B39","doi-asserted-by":"publisher","first-page":"1179551419869917","DOI":"10.1177\/1179551419869917","article-title":"Prevalence of thymic parathyroids in primary hyperparathyroidism during radioguided parathyroidectomy","volume":"12","author":"Dream","year":"2019","journal-title":"Clin Med Insights Endocrinol Diabetes"},{"key":"B40","doi-asserted-by":"publisher","DOI":"10.1053\/j.semnuclmed.2005.06.001","article-title":"Radionuclide imaging of the parathyroid glands","volume":"35","author":"Palestro","year":"2005","journal-title":"Semin Nucl Med"},{"key":"B41","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjsurg.2005.10.049","article-title":"Incidence and location of ectopic abnormal parathyroid glands","volume":"191","author":"Phitayakorn","year":"2006","journal-title":"Am J Surg"},{"key":"B42","article-title":"Ectopic parathyroid tissue within the vagus nerve. incidence and possible clinical significance","volume":"112","author":"Lack","year":"1988","journal-title":"Arch Pathol Lab Med"},{"key":"B43","article-title":"An ectopic parathyroid gland in the left axillary region: case report","volume":"89","author":"Sahin","year":"2004","journal-title":"Int Surg"},{"key":"B44","doi-asserted-by":"publisher","first-page":"103161","DOI":"10.1016\/j.amjoto.2021.103161","article-title":"The anatomical basis for preserving the blood supply to the parathyroids during thyroid surgery, and a review of current technologic advances","volume":"43","author":"Shaari","year":"2022","journal-title":"Am J Otolaryngol"},{"key":"B45","doi-asserted-by":"publisher","DOI":"10.21037\/gs.2017.07.10","article-title":"A reappraisal of vascular anatomy of the parathyroid gland based on fluorescence techniques","volume":"6","author":"Sadowski","year":"2017","journal-title":"Gland Surg"},{"key":"B46","doi-asserted-by":"publisher","DOI":"10.1002\/lary.26681","article-title":"Inferior thyroid artery ligation increases hypocalcemia after thyroidectomy: a meta-analysis","volume":"128","author":"Sanabria","year":"2018","journal-title":"Laryngoscope"},{"key":"B47","doi-asserted-by":"publisher","DOI":"10.1210\/er.2018-00220","article-title":"Clinical guidelines and PTH measurement: does assay generation matter","volume":"40","author":"Smit","year":"2019","journal-title":"Endocr Rev"},{"key":"B48","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1016\/j.ecl.2018.07.006","article-title":"Medical hypoparathyroidism","volume":"47","author":"Siraj","year":"2018","journal-title":"Endocrinol Metab Clinics North America"},{"key":"B49","doi-asserted-by":"publisher","DOI":"10.1210\/clinem\/dgaa113","article-title":"Hypoparathyroidism","volume":"105","author":"Bilezikian","year":"2020","journal-title":"J Clin Endocrinol Metab"},{"key":"B50","doi-asserted-by":"publisher","DOI":"10.1001\/jamasurg.2016.2310","article-title":"The American association of endocrine surgeons guidelines for definitive management of primary hyperparathyroidism","volume":"151","author":"Wilhelm","year":"2016","journal-title":"JAMA Surg"},{"key":"B51","doi-asserted-by":"publisher","DOI":"10.1097\/SLA.0000000000003700","article-title":"Detecting the near infrared autofluorescence of the human parathyroid: hype or opportunity","volume":"272","author":"Solorzano","year":"2020","journal-title":"Ann Surg"},{"key":"B52","doi-asserted-by":"publisher","first-page":"e2001066","DOI":"10.1002\/smtd.202001066","article-title":"Surgical navigation for malignancies guided by near-Infrared-II fluorescence imaging","volume":"5","author":"Yang","year":"2021","journal-title":"Small Methods"},{"key":"B53","doi-asserted-by":"publisher","first-page":"5040814","DOI":"10.1155\/2016\/5040814","article-title":"Near-infrared fluorescence-enhanced optical tomography","author":"Zhu","year":"2016","journal-title":"BioMed Res Int 2016"},{"key":"B54","doi-asserted-by":"crossref","DOI":"10.1016\/S1387-2656(05)11007-2","article-title":"Cell and tissue autofluorescence research and diagnostic applications","volume-title":"Biotechnol Annu Rev","author":"Monici","year":"2005"},{"key":"B55","doi-asserted-by":"publisher","DOI":"10.1016\/j.cbpa.2003.08.007","article-title":"In vivo near-infrared fluorescence imaging","volume":"7","author":"Frangioni","year":"2003","journal-title":"Curr Opin Chem Biol"},{"key":"B56","doi-asserted-by":"publisher","DOI":"10.1016\/S1470-2045(11)70130-9","article-title":"Intraoperative MRI-guided resection of glioblastoma multiforme: a systematic review","volume":"12","author":"Kubben","year":"2011","journal-title":"Lancet Oncol"},{"key":"B57","doi-asserted-by":"publisher","DOI":"10.1038\/nrclinonc.2013.123","article-title":"Image-guided cancer surgery using near-infrared fluorescence","volume":"10","author":"Vahrmeijer","year":"2013","journal-title":"Nat Rev Clin Oncol"},{"key":"B58","doi-asserted-by":"crossref","DOI":"10.2310\/7290.2010.00034","article-title":"Image-guided surgery using invisible near-infrared light: fundamentals of clinical translation","volume":"9","author":"Gioux","year":"2010","journal-title":"Mol Imaging"},{"key":"B59","doi-asserted-by":"publisher","DOI":"10.1245\/s10434-011-1566-x","article-title":"Toward optimization of imaging system and lymphatic tracer for near-infrared fluorescent sentinel lymph node mapping in breast cancer","volume":"18","author":"Mieog","year":"2011","journal-title":"Ann Surg Oncol"},{"key":"B60","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1007\/s00464-011-1854-3","article-title":"Near-infrared (NIR) laparoscopy for intraoperative lymphatic road-mapping and sentinel node identification during definitive surgical resection of early-stage colorectal neoplasia","volume":"26","author":"Cahill","year":"2012","journal-title":"Surg Endosc"},{"key":"B61","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2010.01.028","article-title":"Video-assisted thoracoscopic indocyanine green fluorescence imaging system shows sentinel lymph nodes in non-small-cell lung cancer","volume":"141","author":"Yamashita","year":"2011","journal-title":"J Thorac Cardiovasc Surg"},{"key":"B62","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-012-2733-2","article-title":"Real-time near-infrared (NIR) fluorescent cholangiography in single-site robotic cholecystectomy (SSRC): a single-institutional prospective study","volume":"27","author":"Spinoglio","year":"2013","journal-title":"Surg Endosc"},{"key":"B63","doi-asserted-by":"publisher","first-page":"433","DOI":"10.3390\/life11050433","article-title":"Perfusion parameters in near-infrared fluorescence imaging with indocyanine green: a systematic review of the literature","volume":"11","author":"Goncalves","year":"2021","journal-title":"Life (Basel)"},{"key":"B64","doi-asserted-by":"publisher","DOI":"10.2147\/IJN.S207486","article-title":"NIR fluorescence-guided tumor surgery: new strategies for the use of indocyanine green","volume":"14","author":"Egloff-Juras","year":"2019","journal-title":"Int J Nanomed"},{"key":"B65","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0000000000000335","article-title":"Autofluorescence and axial length as prognostic factors for outcomes of macular hole retinal detachment surgery in high myopia","volume":"35","author":"Arias","year":"2015","journal-title":"Retina"},{"key":"B66","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2019.04.072","article-title":"Autofluorescence imaging of parathyroid glands: an assessment of potential indications","volume":"167","author":"Kose","year":"2020","journal-title":"Surgery"},{"key":"B67","doi-asserted-by":"publisher","DOI":"10.1378\/chest.14-1351","article-title":"A pilot study of autofluorescence in the diagnosis of pleural disease","volume":"147","author":"Wang","year":"2015","journal-title":"Chest"},{"key":"B68","doi-asserted-by":"publisher","DOI":"10.1002\/adma.201900321","article-title":"Near-Infrared-II molecular dyes for cancer imaging and surgery","volume":"31","author":"Zhu","year":"2019","journal-title":"Adv Mater"},{"key":"B69","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2013.06.046","article-title":"A novel optical approach to intraoperative detection of parathyroid glands","volume":"154","author":"McWade","year":"2013","journal-title":"Surgery"},{"key":"B70","doi-asserted-by":"publisher","DOI":"10.1002\/lary.30633","article-title":"Identifying parathyroids in pediatric Thyroid\/Parathyroid surgery by near infrared autofluorescence","author":"Belcher","year":"2023","journal-title":"Laryngoscope"},{"key":"B71","doi-asserted-by":"publisher","DOI":"10.1007\/s00268-019-04929-9","article-title":"Autofluorescence in parathyroidectomy: signal intensity correlates with serum calcium and parathyroid hormone but routine clinical use is not justified","volume":"43","author":"DiMarco","year":"2019","journal-title":"World J Surg"},{"key":"B72","doi-asserted-by":"publisher","DOI":"10.1210\/jc.2014-2503","article-title":"Label-free intraoperative parathyroid localization with near-infrared autofluorescence imaging","volume":"99","author":"McWade","year":"2014","journal-title":"J Clin Endocrinol Metab"},{"key":"B73","doi-asserted-by":"publisher","DOI":"10.1245\/s10434-022-11732-9","article-title":"Autofluorescence and artificial intelligence: the future of parathyroid surgery","author":"Duh","year":"2022","journal-title":"Ann Surg Oncol"},{"key":"B74","doi-asserted-by":"publisher","DOI":"10.1007\/s40618-022-01774-x","article-title":"Autofluorescence of parathyroid glands during endocrine surgery with minimally invasive technique","volume":"45","author":"Pastoricchio","year":"2022","journal-title":"J Endocrinol Invest"},{"key":"B75","doi-asserted-by":"publisher","DOI":"10.1002\/jso.26469","article-title":"Fluorescence-guided cancer surgery-a new paradigm","volume":"123","author":"Thammineedi","year":"2021","journal-title":"J Surg Oncol"},{"key":"B76","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1167\/iovs.62.3.36","article-title":"Association of near-infrared and short-wavelength autofluorescence with the retinal sensitivity in eyes with resolved central serous chorioretinopathy","volume":"62","author":"Soga","year":"2021","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"B77","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.ajo.2019.06.001","article-title":"Improved diagnosis of retinal laser injuries using near-infrared autofluorescence","volume":"208","author":"De Silva","year":"2019","journal-title":"Am J Ophthalmol"},{"key":"B78","doi-asserted-by":"publisher","first-page":"024017","DOI":"10.1117\/1.3103310","article-title":"Near-infrared autofluorescence imaging of cutaneous melanins and human skin in vivo","volume":"14","author":"Han","year":"2009","journal-title":"J BioMed Opt"},{"key":"B79","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1016\/j.ajo.2018.10.021","article-title":"Near-infrared autofluorescence in choroideremia: anatomic and functional correlations","volume":"199","author":"Birtel","year":"2019","journal-title":"Am J Ophthalmol"},{"key":"B80","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2007.116665","article-title":"Fundus autofluorescence of choroidal nevus and melanoma","volume":"91","author":"Lavinsky","year":"2007","journal-title":"Br J Ophthalmol"},{"key":"B81","doi-asserted-by":"publisher","DOI":"10.1016\/j.atherosclerosis.2022.01.012","article-title":"Histopathological correlation of near infrared autofluorescence in human cadaver coronary arteries","volume":"344","author":"Kunio","year":"2022","journal-title":"Atherosclerosis"},{"key":"B82","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1038\/s41467-017-00138-x","article-title":"Near-infrared autofluorescence induced by intraplaque hemorrhage and heme degradation as marker for high-risk atherosclerotic plaques","volume":"8","author":"Htun","year":"2017","journal-title":"Nat Commun"},{"key":"B83","doi-asserted-by":"publisher","first-page":"bvac126","DOI":"10.1210\/jendso\/bvac126","article-title":"Adrenal near-infrared autofluorescence","volume":"6","author":"Rajan","year":"2022","journal-title":"J Endocr Soc"},{"key":"B84","doi-asserted-by":"publisher","first-page":"126002","DOI":"10.1117\/1.JBO.25.12.126002","article-title":"Development of a drug-device combination for fluorescence-guided surgery in neuroendocrine tumors","volume":"25","author":"Hernandez Vargas","year":"2020","journal-title":"J BioMed Opt"},{"key":"B85","doi-asserted-by":"publisher","DOI":"10.1245\/s10434-018-6364-2","article-title":"Detection of parathyroid autofluorescence using near-infrared imaging: a multicenter analysis of concordance between different surgeons","volume":"25","author":"Kahramangil","year":"2018","journal-title":"Ann Surg Oncol"},{"key":"B86","doi-asserted-by":"publisher","DOI":"10.1007\/s00268-016-3571-5","article-title":"Intraoperative near-infrared imaging for parathyroid gland identification by auto-fluorescence: a feasibility study","volume":"40","author":"De Leeuw","year":"2016","journal-title":"World J Surg"},{"key":"B87","doi-asserted-by":"publisher","DOI":"10.1002\/jso.26603","article-title":"Can near-infrared autofluorescence imaging be used for intraoperative confirmation of parathyroid tissue","volume":"124","author":"Berber","year":"2021","journal-title":"J Surg Oncol"},{"key":"B88","doi-asserted-by":"publisher","DOI":"10.1002\/lary.29310","article-title":"Comparison of autofluorescence with near-infrared fluorescence imaging between primary and secondary hyperparathyroidism","volume":"131","author":"Takeuchi","year":"2021","journal-title":"Laryngoscope"},{"key":"B89","doi-asserted-by":"publisher","DOI":"10.7150\/ijms.72886","article-title":"Influence of single experience with intraoperative near-infrared autofluorescence on postoperative parathyroid insufficiency after thyroidectomy - a preliminary clinical study","volume":"19","author":"Domoslawski","year":"2022","journal-title":"Int J Med Sci"},{"key":"B90","doi-asserted-by":"publisher","DOI":"10.1089\/thy.2017.0716","article-title":"Developing a clinical prototype to guide surgeons for intraoperative label-free identification of parathyroid glands in real time","volume":"28","author":"Thomas","year":"2018","journal-title":"Thyroid"},{"key":"B91","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1515\/iss-2021-0001","article-title":"Near-infrared fluorescent imaging techniques for the detection and preservation of parathyroid glands during endocrine surgery","volume":"7","author":"Demarchi","year":"2022","journal-title":"Innov Surg Sci"},{"key":"B92","doi-asserted-by":"publisher","DOI":"10.1089\/ve.2021.0008","article-title":"Parathyroid function saving total thyroidectomy using autofluorescence and quantified indocyanine green angiography","volume":"8","author":"Noltes","year":"2021","journal-title":"VideoEndocrinology"},{"key":"B93","doi-asserted-by":"publisher","DOI":"10.1210\/jc.2016-2558","article-title":"Intraoperative real-time localization of normal parathyroid glands with autofluorescence imaging","volume":"101","author":"Kim","year":"2016","journal-title":"J Clin Endocrinol Metab"},{"key":"B94","doi-asserted-by":"publisher","DOI":"10.1016\/j.jamcollsurg.2017.10.015","article-title":"Near-infrared autofluorescence image-guided parathyroid gland mapping in thyroidectomy","volume":"226","author":"Kim","year":"2018","journal-title":"J Am Coll Surg"},{"key":"B95","doi-asserted-by":"publisher","DOI":"10.5582\/bst.2022.01256","article-title":"Real-time intraoperative near-infrared autofluorescence imaging to locate the parathyroid glands: a preliminary report","volume":"16","author":"Qian","year":"2022","journal-title":"Biosci Trends"},{"key":"B96","doi-asserted-by":"publisher","DOI":"10.1089\/thy.2021.0056","article-title":"Near-infrared autofluorescence imaging may reduce temporary hypoparathyroidism in patients undergoing total thyroidectomy and central neck dissection","volume":"31","author":"Kim","year":"2021","journal-title":"Thyroid"},{"key":"B97","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.surg.2015.06.047","article-title":"Establishing the clinical utility of autofluorescence spectroscopy for parathyroid detection","volume":"159","author":"McWade","year":"2016","journal-title":"Surgery"},{"key":"B98","doi-asserted-by":"publisher","DOI":"10.5582\/bst.2022.01256","article-title":"Real-time intraoperative near-infrared autofluorescence imaging to locate the parathyroid glands: a preliminary report","volume":"16","author":"Qian","year":"2022","journal-title":"Biosci Trends"},{"key":"B99","doi-asserted-by":"publisher","DOI":"10.1001\/jamasurg.2019.4613","article-title":"Association of autofluorescence-based detection of the parathyroid glands during total thyroidectomy with postoperative hypocalcemia risk: results of the PARAFLUO multicenter randomized clinical trial","volume":"155","author":"Benmiloud","year":"2020","journal-title":"JAMA Surg"},{"key":"B100","doi-asserted-by":"publisher","DOI":"10.1007\/s12020-020-02599-5","article-title":"The effect of intraoperative autofluorescence monitoring on unintentional parathyroid gland excision rates and postoperative PTH concentrations-a single-blind randomized-controlled trial","volume":"72","author":"Papavramidis","year":"2021","journal-title":"Endocrine"},{"key":"B101","doi-asserted-by":"publisher","DOI":"10.1007\/s00423-022-02624-3","article-title":"Near-infrared autofluorescence of the parathyroid glands during thyroidectomy for the prevention of hypoparathyroidism: a prospective randomized clinical trial","volume":"407","author":"Wolf","year":"2022","journal-title":"Langenbecks Arch Surg"},{"key":"B102","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2017.06.022","article-title":"Impact of autofluorescence-based identification of parathyroids during total thyroidectomy on postoperative hypocalcemia: a before and after controlled study","volume":"163","author":"Benmiloud","year":"2018","journal-title":"Surgery"},{"key":"B103","doi-asserted-by":"publisher","DOI":"10.1002\/hed.26733","article-title":"Intraoperative near-infrared autofluorescence imaging for hypocalcemia risk reduction after total thyroidectomy: evidence from a meta-analysis","volume":"43","author":"Weng","year":"2021","journal-title":"Head Neck"},{"key":"B104","doi-asserted-by":"publisher","first-page":"zraa047","DOI":"10.1093\/bjsopen\/zraa047","article-title":"Autofluorescence pattern of parathyroid adenomas","volume":"5","author":"Demarchi","year":"2021","journal-title":"BJS Open"},{"key":"B105","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2018.08.006","article-title":"Heterogeneous and low-intensity parathyroid autofluorescence: patterns suggesting hyperfunction at parathyroid exploration","volume":"165","author":"Kose","year":"2019","journal-title":"Surgery"},{"key":"B106","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-016-5338-3","article-title":"Intraoperative near-infrared autofluorescence imaging of parathyroid glands","volume":"31","author":"Ladurner","year":"2017","journal-title":"Surg Endosc"},{"key":"B107","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1186\/s12893-019-0590-9","article-title":"Parathyroid identification by autofluorescence - preliminary report on five cases of surgery for primary hyperparathyroidism","volume":"19","author":"Serra","year":"2019","journal-title":"BMC Surg"},{"key":"B108","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2022.06.027","article-title":"Smaller parathyroids have higher near-infrared autofluorescence intensity in hyperparathyroidism","volume":"172","author":"Lee","year":"2022","journal-title":"Surgery"},{"key":"B109","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-017-5424-1","article-title":"Increased identification of parathyroid glands using near infrared light during thyroid and parathyroid surgery","volume":"31","author":"Falco","year":"2017","journal-title":"Surg Endosc"},{"key":"B110","doi-asserted-by":"publisher","DOI":"10.1007\/s10895-021-02783-4","article-title":"Spectroscopic analysis of parathyroid and thyroid tissues by ground-state diffuse reflectance and laser induced luminescence: a preliminary report","volume":"31","author":"Serra","year":"2021","journal-title":"J Fluoresc"},{"key":"B111","doi-asserted-by":"publisher","DOI":"10.4103\/tcmj.tcmj_216_20","article-title":"Indocyanine green: an old drug with novel applications","volume":"33","author":"Lu","year":"2021","journal-title":"Tzu Chi Med J"},{"key":"B112","doi-asserted-by":"publisher","DOI":"10.1007\/s00104-022-01659-y","article-title":"[ICG lymph node mapping in cancer surgery of the upper gastrointestinal tract]","volume":"93","author":"M\u00fcller","year":"2022","journal-title":"Chirurgie (Heidelb)"},{"key":"B113","doi-asserted-by":"publisher","DOI":"10.1016\/s1529-1839(04)70234-1","article-title":"Intravenous and indocyanine green angiography","volume":"75","author":"Dzurinko","year":"2004","journal-title":"Optometry"},{"key":"B114","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.3390\/children8111015","article-title":"Fluorescence image-guided navigation surgery using indocyanine green for hepatoblastoma","volume":"8","author":"Hiyama","year":"2021","journal-title":"Children (Basel)"},{"key":"B115","doi-asserted-by":"publisher","DOI":"10.1016\/s0161-6420(94)31303-0","article-title":"Adverse reactions due to indocyanine green","volume":"101","author":"Hope-Ross","year":"1994","journal-title":"Ophthalmology"},{"key":"B116","doi-asserted-by":"publisher","first-page":"102028","DOI":"10.1016\/j.pdpdt.2020.102028","article-title":"Indocyanine green fluorescence angiography-guided transoral endoscopic thyroidectomy and parathyroidectomy: first clinical report","volume":"32","author":"Turan","year":"2020","journal-title":"Photodiagnosis Photodyn Ther"},{"key":"B117","doi-asserted-by":"publisher","DOI":"10.1016\/j.urology.2019.05.008","article-title":"Indocyanine green (ICG) in urologic surgery","volume":"132","author":"Kaplan-Marans","year":"2019","journal-title":"Urology"},{"key":"B118","doi-asserted-by":"publisher","DOI":"10.1016\/j.pdpdt.2016.12.005","article-title":"Indocyanine green fluorescence imaging in hepatobiliary surgery","volume":"17","author":"Majlesara","year":"2017","journal-title":"Photodiagnosis Photodyn Ther"},{"key":"B119","doi-asserted-by":"publisher","DOI":"10.3748\/wjg.v24.i27.2921","article-title":"Indocyanine green-based fluorescence imaging in visceral and hepatobiliary and pancreatic surgery: state of the art and future directions","volume":"24","author":"Baiocchi","year":"2018","journal-title":"World J Gastroenterol"},{"key":"B120","doi-asserted-by":"publisher","DOI":"10.1093\/bjs\/znaa139","article-title":"Indocyanine green fluorescence angiography versus standard intraoperative methods for prevention of anastomotic leak in colorectal surgery: meta-analysis","volume":"108","author":"Trastulli","year":"2021","journal-title":"Br J Surg"},{"key":"B121","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjps.2017.01.020","article-title":"Indocyanine green applications in plastic surgery: a review of the literature","volume":"70","author":"Burnier","year":"2017","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"B122","doi-asserted-by":"publisher","first-page":"E4","DOI":"10.3171\/2020.10.FOCUS20782","article-title":"Applications of indocyanine green in brain tumor surgery: review of clinical evidence and emerging technologies","volume":"50","author":"Teng","year":"2021","journal-title":"Neurosurg Focus"},{"key":"B123","doi-asserted-by":"publisher","DOI":"10.1016\/j.ciresp.2021.11.018","article-title":"Indocyanine green (ICG) fluorescence guide for the use and indications in general surgery: recommendations based on the descriptive review of the literature and the analysis of experience","volume":"100","author":"Morales-Conde","year":"2022","journal-title":"Cir Esp (Engl Ed)"},{"key":"B124","doi-asserted-by":"publisher","DOI":"10.1002\/bjs5.50157","article-title":"Network meta-analysis of novel and conventional sentinel lymph node biopsy techniques in breast cancer","volume":"3","author":"Mok","year":"2019","journal-title":"BJS Open"},{"key":"B125","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejogrb.2016.09.027","article-title":"Indocyanine green and infrared fluorescence in detection of sentinel lymph nodes in endometrial and cervical cancer staging - a systematic review","volume":"206","author":"Rocha","year":"2016","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"key":"B126","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-016-5330-y","article-title":"Intraoperative localization of the parathyroid glands with indocyanine green and Firefly(R) technology during BABA robotic thyroidectomy","volume":"31","author":"Yu","year":"2017","journal-title":"Surg Endosc"},{"key":"B127","doi-asserted-by":"publisher","DOI":"10.12998\/wjcc.v8.i21.5480","article-title":"Potential protection of indocyanine green on parathyroid gland function during near-infrared laparoscopic-assisted thyroidectomy: a case report and literature review","volume":"8","author":"Peng","year":"2020","journal-title":"World J Clin cases"},{"key":"B128","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1186\/s13256-021-03009-8","article-title":"Intraoperative detection of parathyroid glands by autofluorescence identification using image-based system: report of 15 cases","volume":"15","author":"Gorobeiko","year":"2021","journal-title":"J Med Case Rep"},{"key":"B129","doi-asserted-by":"publisher","DOI":"10.21037\/gs.2019.12.15","article-title":"Near-infrared fluorescence in robotic thyroidectomy","volume":"9","author":"Muraveika","year":"2020","journal-title":"Gland Surg"},{"key":"B130","doi-asserted-by":"publisher","first-page":"940585","DOI":"10.1155\/2012\/940585","article-title":"A review of indocyanine green fluorescent imaging in surgery","volume":"2012","author":"Alander","year":"2012","journal-title":"Int J BioMed Imaging"},{"key":"B131","doi-asserted-by":"publisher","DOI":"10.1007\/s00423-021-02228-3","article-title":"Total thyroidectomy with intraoperative neural monitoring and near-infrared fluorescence imaging","volume":"406","author":"Barbieri","year":"2021","journal-title":"Langenbecks Arch Surg"},{"key":"B132","article-title":"Parathyroid autotransplantation","volume":"113","author":"Baumann","year":"1993","journal-title":"Surgery"},{"key":"B133","doi-asserted-by":"publisher","first-page":"2560","DOI":"10.3390\/molecules24142560","article-title":"Parathyroid autofluorescence-how does it affect parathyroid and thyroid surgery? a 5 year experience","volume":"24","author":"Ladurner","year":"2019","journal-title":"Molecules"},{"key":"B134","doi-asserted-by":"publisher","first-page":"4687951","DOI":"10.1155\/2019\/4687951","article-title":"Intraoperative near-infrared autofluorescence and indocyanine green imaging to identify parathyroid glands: a comparison","volume":"2019","author":"Lerchenberger","year":"2019","journal-title":"Int J Endocrinol"},{"key":"B135","doi-asserted-by":"publisher","DOI":"10.21037\/gs.2017.09.04","article-title":"Comparison of indocyanine green fluorescence and parathyroid autofluorescence imaging in the identification of parathyroid glands during thyroidectomy","volume":"6","author":"Kahramangil","year":"2017","journal-title":"Gland Surg"},{"key":"B136","doi-asserted-by":"publisher","DOI":"10.1002\/lio2.868","article-title":"Intraoperative quantitative assessment of parathyroid blood flow during total thyroidectomy using indocyanine green fluorescence imaging - surgical strategies for preserving the function of parathyroid glands","volume":"7","author":"Iritani","year":"2022","journal-title":"Laryngoscope Investig Otolaryngol"},{"key":"B137","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1007\/s13304-021-01202-4","article-title":"The utility of indocyanine green (ICG) for the identification and assessment of viability of the parathyroid glands during thyroidectomy","volume":"74","author":"Priyanka","year":"2022","journal-title":"Updates Surg"},{"key":"B138","doi-asserted-by":"publisher","DOI":"10.1007\/s00268-021-06353-4","article-title":"Intraoperative mapping angiograms of the parathyroid glands using indocyanine green during thyroid surgery: results of the fluogreen study","volume":"46","author":"Benmiloud","year":"2022","journal-title":"World J Surg"},{"key":"B139","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjsurg.2021.05.001","article-title":"Comparing intraoperative parathyroid identification based on surgeon experience versus near infrared autofluorescence detection - a surgeon-blinded multi-centric study","volume":"222","author":"Thomas","year":"2021","journal-title":"Am J Surg"}],"container-title":["Frontiers in Endocrinology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fendo.2023.1160902\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,22]],"date-time":"2023-05-22T00:53:24Z","timestamp":1684716804000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fendo.2023.1160902\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,22]]},"references-count":139,"alternative-id":["10.3389\/fendo.2023.1160902"],"URL":"https:\/\/doi.org\/10.3389\/fendo.2023.1160902","relation":{},"ISSN":["1664-2392"],"issn-type":[{"value":"1664-2392","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,22]]},"article-number":"1160902"}}