{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T00:45:51Z","timestamp":1793407551727,"version":"4.5.0"},"reference-count":32,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,7,11]],"date-time":"2024-07-11T00:00:00Z","timestamp":1720656000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Endocrinol."],"abstract":"<jats:sec><jats:title>Purpose<\/jats:title><jats:p>To explore the consistency of FRACTURE (Fast-field-echo Resembling A CT Using Restricted Echo-spacing) MRI and X-Ray\/computerized tomography (CT) in the evaluation of bone injuries in knee and ankle joints.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>From Nov. 2020 to Jul. 2023, 42 patients with knee joint or ankle joint injuries who underwent FRACTURE MRI examinations were retrospectively collected. 11 patients were examined by both X-Ray and FRACTURE examinations. 31 patients were examined by both CT and FRACTURE examinations. The fracture, osteophyte, and bone destruction of the joints were evaluated by two radiologists using X-Ray\/CT and FRACTURE images, respectively. Kappa test was used for consistency analysis.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The evaluation consistency of fracture, osteophyte and bone destruction via X-Ray and FRACTURE images by radiologist 1 were 0.879, 0.867 and 0.847 respectively, and for radiologist 2 were 0.899, 0.930, and 0.879, respectively. The evaluation consistency of fracture, osteophyte and bone destruction via CT and FRACTURE images by radiologist 1 were 0.938, 0.937 and 0.868 respectively, and for radiologist 2 were 0.961, 0.930, and 0.818, respectively.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>For fracture, osteophyte, and bone destruction of knee and ankle joints. FRACTURE MRI showed a high consistency with X-Ray\/CT examinations.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fendo.2024.1421876","type":"journal-article","created":{"date-parts":[[2024,7,11]],"date-time":"2024-07-11T04:48:30Z","timestamp":1720673310000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":13,"title":["Bone injury imaging in knee and ankle joints using fast-field-echo resembling a CT using restricted echo-spacing MRI: a feasibility study"],"prefix":"10.3389","volume":"15","author":[{"given":"Nan","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhengshi","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Funing","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lihua","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liangjie","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ailian","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qingwei","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2024,7,11]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","DOI":"10.1007\/s11604-021-01224-3","article-title":"Subchondral insufficiency fracture of the knee: review of current concepts and radiological differential diagnoses","volume":"40","author":"Ochi","year":"2022","journal-title":"Jpn J Radiol"},{"key":"B2","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics13152586","article-title":"MR-imaging in osteoarthritis: current standard of practice and future outlook","volume":"13","author":"Ehmig","year":"2023","journal-title":"Diagnostics (Basel)"},{"key":"B3","doi-asserted-by":"publisher","first-page":"16238","DOI":"10.1038\/s41598-020-73301-y","article-title":"A novel MRI compatible mouse fracture model to characterize and monitor bone regeneration and tissue composition","volume":"10","author":"Schmitz","year":"2020","journal-title":"Sci Rep"},{"key":"B4","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-021-05125-5","article-title":"Zero echo time pediatric musculoskeletal magnetic resonance imaging: initial experience","volume":"51","author":"Sandberg","year":"2021","journal-title":"Pediatr Radiol"},{"key":"B5","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-022-09061-2","article-title":"Diagnostic value of water-fat-separated images and CT-like susceptibility-weighted images extracted from a single ultrashort echo time sequence for the evaluation of vertebral fractures and degenerative changes of the spine","volume":"33","author":"Feuerriegel","year":"2023","journal-title":"Eur Radiol"},{"key":"B6","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2021.109915","article-title":"3D MRI with CT-like bone contrast - An overview of current approaches and practical clinical implementation","volume":"143","author":"Chong","year":"2021","journal-title":"Eur J Radiol"},{"key":"B7","doi-asserted-by":"publisher","DOI":"10.1016\/j.diii.2020.02.010","article-title":"FRACTURE MRI: Optimized 3D multi-echo in-phase sequence for bone damage assessment in craniocerebral gunshot injuries","volume":"101","author":"Gascho","year":"2020","journal-title":"Diagn Interv Imaging"},{"key":"B8","doi-asserted-by":"publisher","DOI":"10.1007\/s00256-020-03659-7","article-title":"Fast field echo resembling a CT using restricted echo-spacing (FRACTURE): a novel MRI technique with superior bone contrast","volume":"50","author":"Johnson","year":"2021","journal-title":"Skeletal Radiol"},{"key":"B9","doi-asserted-by":"publisher","DOI":"10.1016\/j.neurad.2021.11.001","article-title":"Evaluation of ultrashort echo-time (UTE) and fast-field-echo (FRACTURE) sequences for skull bone visualization and fracture detection - A postmortem study","volume":"49","author":"Deininger-Czermak","year":"2022","journal-title":"J Neuroradiol"},{"key":"B10","doi-asserted-by":"publisher","DOI":"10.1007\/s11604-023-01449-4","article-title":"Magnetic resonance bone imaging: applications to vertebral lesions","volume":"41","author":"Tsuchiya","year":"2023","journal-title":"Jpn J Radiol"},{"key":"B11","doi-asserted-by":"publisher","first-page":"041303","DOI":"10.1063\/5.0086459","article-title":"Making the invisible visible-ultrashort echo time magnetic resonance imaging: Technical developments and applications","volume":"9","author":"Ma","year":"2022","journal-title":"Appl Phys Rev"},{"key":"B12","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.24713","article-title":"UTE imaging in the musculoskeletal system","volume":"41","author":"Chang","year":"2015","journal-title":"J Magn Reson Imaging"},{"key":"B13","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1002\/jmri.28843","article-title":"Zero echo time magnetic resonance imaging; techniques and clinical utility in musculoskeletal system","volume":"59","author":"Fujisaki","year":"2024","journal-title":"J Magn Reson Imaging"},{"key":"B14","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr.20190272","article-title":"CT-like MRI using the zero-TE technique for osseous changes of the TMJ","volume":"49","author":"Lee","year":"2020","journal-title":"Dentomaxillofac Radiol"},{"key":"B15","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1007\/s00586-021-07099-2","article-title":"Evaluation of the degenerative lumbar osseous morphology using zero echo time magnetic resonance imaging (ZTE-MRI)","volume":"31","author":"Hou","year":"2022","journal-title":"Eur Spine J"},{"key":"B16","doi-asserted-by":"publisher","DOI":"10.3389\/fendo.2020.555756","article-title":"An update in qualitative imaging of bone using ultrashort echo time magnetic resonance","volume":"11","author":"Jerban","year":"2020","journal-title":"Front Endocrinol (Lausanne)"},{"key":"B17","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-020-07597-9","article-title":"CT-like images based on T1 spoiled gradient-echo and ultra-short echo time MRI sequences for the assessment of vertebral fractures and degenerative bone changes of the spine","volume":"31","author":"Schwaiger","year":"2021","journal-title":"Eur Radiol"},{"key":"B18","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-023-09602-3","article-title":"Zero echo time MRI in shoulder MRI protocols for the diagnosis of rotator cuff calcific tendinopathy improves identification of calcific deposits compared to conventional MR sequences but remains sub-optimal compared to radiographs","volume":"33","author":"Puel","year":"2023","journal-title":"Eur Radiol"},{"key":"B19","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-023-09939-9","article-title":"Assessment of glenoid bone loss and other osseous shoulder pathologies comparing MR-based CT-like images with conventional CT","volume":"33","author":"Feuerriegel","year":"2023","journal-title":"Eur Radiol"},{"key":"B20","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.28583","article-title":"Zero echo time vs. T1-weighted MRI for assessment of cortical and medullary bone morphology abnormalities using CT as the reference standard","volume":"58","author":"Xu","year":"2023","journal-title":"J Magn Reson Imaging"},{"key":"B21","doi-asserted-by":"publisher","DOI":"10.1002\/jor.25557","article-title":"MRI-based synthetic CT in the detection of knee osteoarthritis: Comparison with CT","volume":"41","author":"Arbabi","year":"2023","journal-title":"J Orthop Res"},{"key":"B22","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2017170906","article-title":"Technical developments: zero echo time imaging of the shoulder: enhanced osseous detail by using MR imaging","volume":"286","author":"Breighner","year":"2018","journal-title":"Radiology"},{"key":"B23","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2010.11.003","article-title":"Short T2 contrast with three-dimensional ultrashort echo time imaging","volume":"29","author":"Du","year":"2011","journal-title":"Magn Reson Imaging"},{"key":"B24","doi-asserted-by":"publisher","DOI":"10.1007\/s00256-018-2898-4","article-title":"Feasibility of using an inversion-recovery ultrashort echo time (UTE) sequence for quantification of glenoid bone loss","volume":"47","author":"Ma","year":"2018","journal-title":"Skeletal Radiol"},{"key":"B25","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.27478","article-title":"Comparison of MR ultrashort echo time and optimized 3D-multiecho in-phase sequence to computed tomography for assessment of the osseous craniocervical junction","volume":"53","author":"Deininger-Czermak","year":"2021","journal-title":"J Magn Reson Imaging"},{"key":"B26","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2021.109999","article-title":"MRI-based synthetic CT of the lumbar spine: Geometric measurements for surgery planning in comparison with CT","volume":"144","author":"Morb\u00e9e","year":"2021","journal-title":"Eur J Radiol"},{"key":"B27","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2020201537","article-title":"MRI-based synthetic CT in the detection of structural lesions in patients with suspected sacroiliitis: comparison with MRI","volume":"298","author":"Jans","year":"2021","journal-title":"Radiology"},{"key":"B28","doi-asserted-by":"publisher","DOI":"10.1002\/mp.12173","article-title":"Spectral characterization of tissues in high spectral and spatial resolution MR images: Implications for a classification-based synthetic CT algorithm","volume":"44","author":"Wood","year":"2017","journal-title":"Med Phys"},{"key":"B29","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A7588","article-title":"Deep learning for synthetic CT from bone MRI in the head and neck","volume":"43","author":"Bambach","year":"2022","journal-title":"AJNR Am J Neuroradiol"},{"key":"B30","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2021.01.001","article-title":"Effect of hybrid of compressed sensing and parallel imaging on the quantitative values measured by 3D quantitative synthetic MRI: A phantom study","volume":"78","author":"Murata","year":"2021","journal-title":"Magn Reson Imaging"},{"key":"B31","doi-asserted-by":"publisher","DOI":"10.1007\/s00117-020-00788-x","article-title":"Diagnostic value of a 3D-SPACE-sequence with compressed sensing technology for the knee joint","volume":"61","author":"Pfeifer","year":"2021","journal-title":"Radiologe"},{"key":"B32","doi-asserted-by":"publisher","DOI":"10.1007\/s11547-023-01589-7","article-title":"Added value of ultra-short echo time and fast field echo using restricted echo-spacing MR imaging in the assessment of the osseous cervical spine","volume":"128","author":"Deininger-Czermak","year":"2023","journal-title":"Radiol Med"}],"container-title":["Frontiers in Endocrinology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fendo.2024.1421876\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,11]],"date-time":"2024-07-11T04:48:33Z","timestamp":1720673313000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fendo.2024.1421876\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,11]]},"references-count":32,"alternative-id":["10.3389\/fendo.2024.1421876"],"URL":"https:\/\/doi.org\/10.3389\/fendo.2024.1421876","relation":{},"ISSN":["1664-2392"],"issn-type":[{"value":"1664-2392","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,11]]},"article-number":"1421876"}}