{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T04:46:51Z","timestamp":1785732411299,"version":"3.56.0"},"reference-count":24,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T00:00:00Z","timestamp":1785715200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Endocrinol."],"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To evaluate the diagnostic performance of a commercial AI-assisted ultrasound system and C-TIRADS-based assessment among sonographers with different levels of experience, and to explore how two AI-assisted adjustment strategies performed in a retrospective clinical workflow for thyroid nodule evaluation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This retrospective single-center study included adult patients with thyroid nodules who underwent conventional ultrasonography and commercial AI-assisted analysis at our hospital between December 2022 and December 2023 and had available reference-standard outcomes. Three senior and three junior sonographers independently reviewed stored ultrasound images and videos and reached group-consensus C-TIRADS classifications while blinded to AI results and final diagnoses. Two AI-assisted integration strategies were evaluated: Strategy 1 required a one-level adjustment of the initial C-TIRADS category according to AI output, whereas Strategy 2 allowed flexible reconsideration after review of the AI result. Surgical histopathology or cytological results with follow-up-supported benign classification were used as reference standards. Diagnostic performance, agreement with reference standards, and biopsy-related indicators were compared across approaches.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>A total of 389 thyroid nodules from 343 patients were included. Because the cohort required cytological or pathological confirmation and complete imaging data, the study population was enriched for malignancy (58.10%). The AI system showed higher sensitivity and accuracy than the junior sonographer group and comparable performance to the senior sonographer group. Among senior sonographers, the flexible strategy was associated with improvements in sensitivity, accuracy, negative predictive value, agreement, and AUC, whereas the mandatory strategy did not yield significant overall benefit. Among junior sonographers, the mandatory strategy was associated with improvements in sensitivity, accuracy, negative predictive value, agreement, and AUC, whereas the flexible strategy showed limited benefit. In this selected cohort, the more favorable strategy for each experience group was also associated with lower unnecessary biopsy rates and higher positive biopsy yields, without a significant increase in missed diagnoses.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In this retrospective single-center, pathology-enriched cohort, the effect of AI-assisted C-TIRADS adjustment appeared to vary by sonographer experience. Mandatory adjustment may be more helpful for junior sonographers, whereas flexible integration may be more useful for senior sonographers. These findings should be interpreted as preliminary workflow observations and require validation in larger prospective multicenter studies.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fendo.2026.1746242","type":"journal-article","created":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T04:27:55Z","timestamp":1785731275000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Experience-dependent integration of a commercial AI system with C-TIRADS for thyroid nodule assessment: a retrospective single-center study"],"prefix":"10.3389","volume":"17","author":[{"given":"Jian","family":"Ding","sequence":"first","affiliation":[{"name":"Department of Ultrasound, Zhalantun People\u2019s Hospital","place":["Hulunbuir, China"]},{"name":"Department of Ultrasound, Affiliated Hospital of Inner Mongolia Medical University","place":["Hohhot, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Minjie","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Ultrasound, Zhalantun People\u2019s Hospital","place":["Hulunbuir, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yingxia","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Ultrasound, Affiliated Hospital of Inner Mongolia Medical University","place":["Hohhot, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,8,3]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","DOI":"10.1038\/s41574-024-01025-4","article-title":"The diagnosis and management of thyroid nodules: a review","volume":"319","author":"Durante","year":"2018","journal-title":"Jama"},{"key":"B2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0179387","article-title":"Overdiagnosis and overtreatment of thyroid cancer: a population-based temporal trend study","volume":"12","author":"Jegerlehner","year":"2017","journal-title":"PLoS One"},{"key":"B3","doi-asserted-by":"publisher","DOI":"10.1007\/s12020-024-03731-5","article-title":"Interobserver variability in thyroid ultrasound","volume":"85","author":"de Carlos","year":"2024","journal-title":"Endocrine"},{"key":"B4","doi-asserted-by":"publisher","DOI":"10.1089\/thy.2008.0354","article-title":"Interobserver and intraobserver variations in ultrasound assessment of thyroid nodules","volume":"20","author":"Choi","year":"2010","journal-title":"Thyroid"},{"key":"B5","doi-asserted-by":"publisher","DOI":"10.3389\/fendo.2021.763897","article-title":"Explore the diagnostic efficiency of Chinese thyroid imaging reporting and data systems by comparing with the other four systems (ACR TI-RADS, Kwak-TIRADS, KSThR-TIRADS, and EU-TIRADS): a single-center study","volume":"12","author":"Qi","year":"2021","journal-title":"Front Endocrinol (Lausanne)"},{"key":"B6","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1007\/s12020-023-03304-y","article-title":"Explore the diagnostic performance of 2020 Chinese thyroid imaging reporting and data systems by comparing with the 2017 ACR-TIRADS guidelines: a single-center study","volume":"80","author":"Cai","year":"2023","journal-title":"Endocrine"},{"key":"B7","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2023.1060702","article-title":"Artificial intelligence in thyroid ultrasound","volume":"13","author":"Cao","year":"2023","journal-title":"Front Oncol"},{"key":"B8","doi-asserted-by":"publisher","DOI":"10.21037\/qims-23-908","article-title":"A narrative review of deep learning in thyroid imaging: current progress and future prospects","volume":"14","author":"Yang","year":"2024","journal-title":"Quant Imaging Med Surg"},{"key":"B9","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-022-07436-1","article-title":"A comparison of artificial intelligence versus radiologists in the diagnosis of thyroid nodules using ultrasonography: a systematic review and meta-analysis","volume":"279","author":"Potipimpanon","year":"2022","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"B10","doi-asserted-by":"publisher","DOI":"10.1155\/2022\/9492056","article-title":"Accuracy of ultrasound diagnosis of thyroid nodules based on artificial intelligence-assisted diagnostic technology: a systematic review and meta-analysis","volume":"2022","author":"Xue","year":"2022","journal-title":"Int J Endocrinol"},{"key":"B11","doi-asserted-by":"publisher","DOI":"10.3389\/fendo.2022.1018321","article-title":"Identification of benign and Malignant thyroid nodules based on dynamic AI ultrasound intelligent auxiliary diagnosis system","volume":"13","author":"Wang","year":"2022","journal-title":"Front Endocrinol (Lausanne)"},{"key":"B12","doi-asserted-by":"publisher","DOI":"10.21037\/qims-22-889","article-title":"Diagnostic value of a dynamic artificial intelligence ultrasonic intelligent auxiliary diagnosis system for benign and Malignant thyroid nodules in patients with Hashimoto thyroiditis","volume":"13","author":"Wang","year":"2023","journal-title":"Quant Imaging Med Surg"},{"key":"B13","doi-asserted-by":"publisher","DOI":"10.2174\/1573405618666220422132251","article-title":"A comparison of the performances of artificial intelligence system and radiologists in the ultrasound diagnosis of thyroid nodules","volume":"18","author":"He","year":"2022","journal-title":"Curr Med Imaging"},{"key":"B14","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1159\/000347144","article-title":"Standardized ultrasound report for thyroid nodules: the endocrinologist\u2019s viewpoint","volume":"2","author":"Andrioli","year":"2013","journal-title":"Eur Thyroid J"},{"key":"B15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacr.2015.07.011","article-title":"Thyroid ultrasound reporting lexicon: white paper of the ACR thyroid imaging, reporting and data system (TIRADS) committee","volume":"12","author":"Grant","year":"2015","journal-title":"J Am Coll Radiol"},{"key":"B16","doi-asserted-by":"publisher","first-page":"197","DOI":"10.7863\/jum.2012.31.2.197","article-title":"Differentiating benign from Malignant thyroid nodules: comparison of 2- and 3- dimensional sonography","volume":"31","author":"Jang","year":"2012","journal-title":"J Ultrasound Med"},{"key":"B17","doi-asserted-by":"publisher","DOI":"10.1097\/md.0000000000031106","article-title":"Interobserver variability in ultrasound assessment of thyroid nodules","volume":"101","author":"Alyami","year":"2022","journal-title":"Med (Baltimore)"},{"key":"B18","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.17.19192","article-title":"Interobserver variability of sonographic features used in the American College of Radiology thyroid imaging reporting and data system","volume":"211","author":"Hoang","year":"2018","journal-title":"AJR Am J Roentgenol"},{"key":"B19","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-022-09378-y","article-title":"Clinical value of artificial intelligence in thyroid ultrasound: a prospective study from the real world","volume":"33","author":"Li","year":"2023","journal-title":"Eur Radiol"},{"key":"B20","doi-asserted-by":"publisher","first-page":"20448","DOI":"10.21203\/rs.3.rs-568240\/v1","article-title":"A beneficial role of computer-aided diagnosis system for less experienced physicians in the diagnosis of thyroid nodule on ultrasound","volume":"11","author":"Kang","year":"2021","journal-title":"Sci Rep"},{"key":"B21","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-018-5772-9","article-title":"Computer-aided diagnosis system for thyroid nodules on ultrasonography: diagnostic performance and reproducibility based on the experience level of operators","volume":"29","author":"Jeong","year":"2019","journal-title":"Eur Radiol"},{"key":"B22","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.17.18822","article-title":"Comparison of performance characteristics of American College of Radiology TI-RADS, Korean Society of Thyroid Radiology TIRADS, and American Thyroid Association guidelines","volume":"210","author":"Middleton","year":"2018","journal-title":"AJR Am J Roentgenol"},{"key":"B23","doi-asserted-by":"publisher","DOI":"10.1089\/thy.2018.0094","article-title":"Diagnostic performance of ultrasound-based risk-stratification systems for thyroid nodules: comparison of the 2015 American Thyroid Association guidelines with the 2016 Korean Thyroid Association\/Korean Society of Thyroid Radiology and 2017 American College of Radiology guidelines","volume":"28","author":"Ha","year":"2018","journal-title":"Thyroid"},{"key":"B24","doi-asserted-by":"publisher","first-page":"398","DOI":"10.1634\/theoncologist.2019-0362","article-title":"A multidisciplinary head-to-head comparison of American College of Radiology thyroid imaging and reporting data system and American Thyroid Association ultrasound risk stratification systems","volume":"25","author":"Huang","year":"2020","journal-title":"Oncologist"}],"container-title":["Frontiers in Endocrinology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fendo.2026.1746242\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T04:27:57Z","timestamp":1785731277000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fendo.2026.1746242\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,3]]},"references-count":24,"alternative-id":["10.3389\/fendo.2026.1746242"],"URL":"https:\/\/doi.org\/10.3389\/fendo.2026.1746242","relation":{},"ISSN":["1664-2392"],"issn-type":[{"value":"1664-2392","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,3]]},"article-number":"1746242"}}