{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T05:05:19Z","timestamp":1784264719884,"version":"3.55.0"},"reference-count":25,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T00:00:00Z","timestamp":1784246400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Endocrinol."],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Ultrasound-guided fine-needle aspiration biopsy (FNAB) is widely used for thyroid nodule evaluation, but nondiagnostic cytology can lead to repeat procedures and delayed management. Because needle approach is influenced by nodule size, anatomical risk, access route, and needle-tip visibility, simple in-plane versus out-of-plane comparisons may not fully reflect clinical decision-making. This study evaluated the association between needle approach and diagnostic adequacy and explored whether the findings could inform a preliminary, risk-adapted trajectory-selection concept.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This multicenter retrospective cohort study included 506 thyroid nodules that underwent clinically indicated ultrasound-guided FNAB between September 2024 and December 2025 at three tertiary hospitals. One center formed the primary cohort, and two independent centers formed the external validation cohort. Diagnostic adequacy was defined as Bethesda category II-VI cytology, and Bethesda category I cytology was retained in the analysis as a nondiagnostic outcome rather than excluded. Multivariable logistic regression was used to evaluate the association between needle approach and diagnostic adequacy, with adjustment for nodule size category, complex anatomical location, operator experience, and center source in pooled analyses. Stabilized inverse probability of treatment weighting was performed as a sensitivity analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Among 506 nodules, 289 were sampled using the in-plane approach and 217 using the out-of-plane approach. Diagnostic adequacy was higher with the in-plane approach than with the out-of-plane approach (98.3% vs. 85.7%;\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0&amp;lt;\u00a00.001). The adjusted association remained significant in the primary cohort (adjusted odds ratio [OR], 9.39; 95% confidence interval [CI], 2.37\u201337.18), external validation cohort (adjusted OR, 14.51; 95% CI, 2.82\u201374.74), and pooled center-adjusted model (adjusted OR, 12.10; 95% CI, 4.28\u201334.20). Weighted sensitivity analysis yielded similar results. Satisfactory needle-tip visualization was more frequent with the in-plane approach (97.2% vs. 63.6%;\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0&amp;lt;\u00a00.001), whereas immediate hematoma did not differ significantly between approaches (6.2% vs. 9.2%;\n                      <jats:italic>P<\/jats:italic>\n                      \u00a0=\u00a00.234).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The in-plane approach was associated with higher diagnostic adequacy without a statistically significant increase in immediate hematoma. These findings provide preliminary, hypothesis-generating multicenter evidence that may inform risk-adapted trajectory selection for ultrasound-guided thyroid FNAB.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fendo.2026.1908297","type":"journal-article","created":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T04:22:47Z","timestamp":1784262167000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Risk-adapted trajectory selection for ultrasound-guided thyroid fine-needle aspiration biopsy: a multicenter study of in-plane and out-of-plane approaches"],"prefix":"10.3389","volume":"17","author":[{"given":"Xiubin","family":"Tang","sequence":"first","affiliation":[{"name":"Department of Ultrasound, Zhangzhou Affiliated Hospital of Fujian Medical University","place":["Zhangzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenjin","family":"Lin","sequence":"additional","affiliation":[{"name":"Department of Ultrasound, The Union Hospital Affiliated to Fujian Medical University","place":["Fuzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Youhai","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University","place":["Quanzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Ultrasound, Zhangzhou Affiliated Hospital of Fujian Medical University","place":["Zhangzhou, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Ultrasound, Zhangzhou Affiliated Hospital of Fujian Medical University","place":["Zhangzhou, China"]},{"name":"Department of Ultrasound, Chinese Academy of Medical Sciences and Peking Union Medical College","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,7,17]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","DOI":"10.1089\/thy.2023.0141","article-title":"The 2023 bethesda system for reporting thyroid cytopathology","volume":"33","author":"Ali","year":"2023","journal-title":"Thyroid"},{"key":"B2","doi-asserted-by":"publisher","DOI":"10.1530\/ETJ-23-0067","article-title":"2023 European Thyroid Association Clinical Practice Guidelines for thyroid nodule management","volume":"12","author":"Durante","year":"2023","journal-title":"Eur Thyroid J"},{"key":"B3","doi-asserted-by":"publisher","first-page":"391","DOI":"10.3348\/kjr.2015.16.2.391","article-title":"Ultrasound-guided fine needle aspiration of thyroid nodules: a consensus statement by the Korean Society of Thyroid Radiology","volume":"16","author":"Lee","year":"2015","journal-title":"Korean J Radiol"},{"key":"B4","doi-asserted-by":"publisher","DOI":"10.1055\/s-0044-1792123","article-title":"Ultrasound-guided thyroid biopsy","volume":"41","author":"Chintapalli","year":"2024","journal-title":"Semin Intervent Radiol"},{"key":"B5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jss.2024.01.018","article-title":"Assessing adequacy: a meta-analysis of rapid onsite evaluation of thyroid nodules","volume":"296","author":"Issa","year":"2024","journal-title":"J Surg Res"},{"key":"B6","doi-asserted-by":"publisher","DOI":"10.3390\/medicina58111639","article-title":"Factors influencing the sample adequacy of ultrasound-guided fine-needle aspiration from solid thyroid nodules for liquid-based cytology: a demographic, sonographic, and technical perspective","volume":"58","author":"Fu","year":"2022","journal-title":"Med (Kaunas)"},{"key":"B7","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjoto.2022.103593","article-title":"US-guided FNA techniques for thyroid nodules: is the short axis better than the long axis","volume":"43","author":"Farhat","year":"2022","journal-title":"Am J Otolaryngol"},{"key":"B8","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjoto.2023.104091","article-title":"Thyroid US-guided FNA techniques: a prospective, randomized controlled study","volume":"45","author":"Cohn","year":"2024","journal-title":"Am J Otolaryngol"},{"key":"B9","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1186\/s40463-022-00587-5","article-title":"Battle of the axes: simulation-based assessment of fine needle aspiration biopsies for thyroid nodules","volume":"51","author":"Samargandy","year":"2022","journal-title":"J Otolaryngol Head Neck Surg"},{"key":"B10","doi-asserted-by":"publisher","DOI":"10.3389\/fendo.2024.1374888","article-title":"Influence of maximum diameter on fine-needle aspiration biopsy outcomes in ACR TI-RADS 5 thyroid nodules","volume":"15","author":"Cao","year":"2024","journal-title":"Front Endocrinol (Lausanne)"},{"key":"B11","doi-asserted-by":"publisher","DOI":"10.3803\/EnM.2023.1669","article-title":"A comprehensive assessment of the harms of fine-needle aspiration biopsy for thyroid nodules: a systematic review","volume":"38","author":"Park","year":"2023","journal-title":"Endocrinol Metab (Seoul)"},{"key":"B12","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.eprac.2024.09.015","article-title":"Nondiagnostic fine needle aspiration of thyroid nodules: review of predisposing factors","volume":"31","author":"Idrees","year":"2025","journal-title":"Endocr Pract"},{"key":"B13","doi-asserted-by":"publisher","DOI":"10.1002\/dc.25386","article-title":"Fate of nondiagnostic thyroid fine needle aspirations","volume":"52","author":"Storozuk","year":"2024","journal-title":"Diagn Cytopathol"},{"key":"B14","doi-asserted-by":"publisher","DOI":"10.1007\/s12020-024-03953-7","article-title":"Timing of the repeat thyroid fine-needle aspiration biopsy: does early repeat biopsy change the rate of nondiagnostic or atypia of undetermined significance cytology result","volume":"86","author":"Dellal Kahramanca","year":"2024","journal-title":"Endocrine"},{"key":"B15","doi-asserted-by":"publisher","DOI":"10.1016\/j.ando.2022.03.002","article-title":"Fine-needle aspiration cytology repetition in thyroid nodules with non-diagnostic findings or atypia of undetermined significance\/follicular lesions of undetermined significance: does time matter","volume":"83","author":"Benido Silva","year":"2022","journal-title":"Ann Endocrinol (Paris)"},{"key":"B16","doi-asserted-by":"publisher","DOI":"10.3348\/kjr.2021.0619","article-title":"Comparison of core needle biopsy and repeat fine-needle aspiration in avoiding diagnostic surgery for thyroid nodules initially diagnosed as atypia\/follicular lesion of undetermined significance","volume":"23","author":"Joo","year":"2022","journal-title":"Korean J Radiol"},{"key":"B17","doi-asserted-by":"publisher","DOI":"10.3389\/fendo.2024.1309005","article-title":"A comparative analysis of core needle biopsy and repeat fine needle aspiration in patients with inconclusive initial cytology of thyroid nodules","volume":"15","author":"Su","year":"2024","journal-title":"Front Endocrinol (Lausanne)"},{"key":"B18","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-020-06473-y","article-title":"Comparison of core-needle biopsy and repeat fine-needle aspiration for thyroid nodules with inconclusive initial cytology","volume":"278","author":"Jung","year":"2021","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"B19","doi-asserted-by":"publisher","DOI":"10.3803\/EnM.2021.1299","article-title":"Diagnostic performance of thyroid core needle biopsy using the revised reporting system: comparison with fine needle aspiration cytology","volume":"37","author":"Kim","year":"2022","journal-title":"Endocrinol Metab (Seoul)"},{"key":"B20","doi-asserted-by":"publisher","first-page":"52","DOI":"10.5334\/jbsr.3577","article-title":"Ultrasonographic characteristics of thyroid nodules with nondiagnostic and atypia of undetermined significance in fine-needle aspiration cytology","volume":"108","author":"Bozer","year":"2024","journal-title":"J Belg Soc Radiol"},{"key":"B21","doi-asserted-by":"publisher","DOI":"10.14366\/usg.24216","article-title":"Inconclusive cytology results of fine-needle aspiration for thyroid nodules: the importance of strict guideline implementation","volume":"44","author":"Cho","year":"2025","journal-title":"Ultrasonography"},{"key":"B22","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.31956","article-title":"Ultrasound-guided conventional versus trans-isthmic fine needle aspiration: comparison of post-biopsy hematoma rates and patients' pain","volume":"14","author":"Yakupo\u011flu","year":"2022","journal-title":"Cureus"},{"key":"B23","doi-asserted-by":"publisher","DOI":"10.3390\/medicina59040690","article-title":"A case of diffuse thyroid hematoma after ultrasound-guided fine needle aspiration","volume":"59","author":"Lee","year":"2023","journal-title":"Med (Kaunas)"},{"key":"B24","doi-asserted-by":"publisher","DOI":"10.3803\/EnM.2018.33.1.114","article-title":"A comparison of ultrasound-guided fine needle aspiration versus core needle biopsy for thyroid nodules: pain, tolerability, and complications","volume":"33","author":"Jeong","year":"2018","journal-title":"Endocrinol Metab (Seoul)"},{"key":"B25","doi-asserted-by":"publisher","DOI":"10.1007\/s40618-024-02378-3","article-title":"The use of telecytology for the evaluation of thyroid nodules fine-needle aspiration biopsy specimens: a systematic review","volume":"47","author":"Oteri","year":"2024","journal-title":"J Endocrinol Invest"}],"container-title":["Frontiers in Endocrinology"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fendo.2026.1908297\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T04:22:49Z","timestamp":1784262169000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fendo.2026.1908297\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,17]]},"references-count":25,"alternative-id":["10.3389\/fendo.2026.1908297"],"URL":"https:\/\/doi.org\/10.3389\/fendo.2026.1908297","relation":{},"ISSN":["1664-2392"],"issn-type":[{"value":"1664-2392","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,17]]},"article-number":"1908297"}}