{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T20:47:21Z","timestamp":1792615641589,"version":"4.5.0"},"reference-count":30,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2021,1,27]],"date-time":"2021-01-27T00:00:00Z","timestamp":1611705600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:p><jats:bold>Purpose:<\/jats:bold> To evaluate the characteristics of peripheral anterior chamber measurements by Pentacam after posterior implantable collamer lenses (ICL) and toric ICL (TICL) with central hole (V4c) implantation.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> Prospective, non-randomized consecutive case series. Forty-six patients undergoing ICL implantation in one eye (Group A) and identically sized TICL in the contralateral eye (Group B) in the Refractive Surgery Center of Eye and ENT Hospital of Fudan University were prospectively included. According to ICL\/TICL size, these eyes were further divided into four subgroups. Peripheral anterior chamber depth (PACD) and angle (ACA) in nasal and temporal sides were measured using Pentacam pre-operatively and 12-month post-operatively.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> The safety indices were 1.34 \u00b1 0.32 and 1.25 \u00b1 0.16 and the efficacy indices were 1.20 \u00b1 0.24 and 1.19 \u00b1 0.19 for ICL and TICL groups, respectively. There was no significant difference in pre-operative PACD or ACA between the two groups. Post-operative PACD and ACA were significantly lower than pre-operative values. Variations of PACD and ACA of TICL group were significantly larger than those of ICL group. The change of ACA for 13.2 mm lenses was significantly larger than that of 12.6 mm lenses. Pre-operative CACD and vault were significantly associated with post-operative PACD, while pre-operative ACA and vault were significantly associated with post-operative ACA.<\/jats:p><jats:p><jats:bold>Conclusions:<\/jats:bold> Variations of PACD and ACA were greater in eyes after TICL (V4c) implantation compared with identically sized ICL (V4c) implantation and with larger size than smaller size lens implantation. Pre-operative anterior chamber structure and vault affect post-operative PACD and ACA.<\/jats:p>","DOI":"10.3389\/fmed.2021.610590","type":"journal-article","created":{"date-parts":[[2021,1,27]],"date-time":"2021-01-27T08:02:55Z","timestamp":1611734575000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":14,"title":["Peripheral Anterior Chamber Depth and Angle Measurements Using Pentacam After Implantation of Toric and Non-toric Implantable Collamer Lenses"],"prefix":"10.3389","volume":"8","author":[{"given":"Jiao","family":"Zhao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wen","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huamao","family":"Miao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingling","family":"Niu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianmin","family":"Shang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoying","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingtao","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2021,1,27]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"150","DOI":"10.3928\/1081597X-20200210-02","article-title":"SMILE versus implantable collamer lens implantation for high myopia: a matched comparative study","volume":"36","author":"Siedlecki","year":"2020","journal-title":"J Refract Surg"},{"key":"B2","doi-asserted-by":"publisher","first-page":"1413","DOI":"10.1007\/s00417-012-2172-8","article-title":"Toric implantable collamer lens for moderate to high myopic astigmatism: 3-year follow-up","volume":"251","author":"Sari","year":"2013","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"B3","doi-asserted-by":"publisher","first-page":"1683","DOI":"10.1016\/j.ophtha.2004.03.026","article-title":"United States food and drug administration clinical trial of the implantable collamer lens (ICL) for moderate to high myopia: three-year follow-up","volume":"111","author":"Sanders","year":"2004","journal-title":"Ophthalmology"},{"key":"B4","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1007\/s40123-017-0109-3","article-title":"Anterior chamber changes after implantable collamer lens implantation in high myopia using Pentacam: a prospective study","volume":"6","author":"Elmohamady","year":"2017","journal-title":"Ophthalmol Ther"},{"key":"B5","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1016\/j.ophtha.2011.07.049","article-title":"Determinants of angle width in chinese singaporeans","volume":"119","author":"Foo","year":"2012","journal-title":"Ophthalmology"},{"key":"B6","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1136\/bjo.2003.020016","article-title":"Defining occludable angles in population surveys: drainage angle width, peripheral anterior synechiae, and glaucomatous optic neuropathy in east asian people","volume":"88","author":"Foster","year":"2004","journal-title":"Br J Ophthalmol"},{"key":"B7","first-page":"540","article-title":"A suggested anatomic classification to define the pupillary block glaucomas","volume":"12","author":"Shaffer","year":"1973","journal-title":"Invest Ophthalmol"},{"key":"B8","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1001\/archophthalmol.2009.41","article-title":"Comparison of slitlamp optical coherence tomography and scanning peripheral anterior chamber depth analyzer to evaluate angle closure in asian eyes","volume":"127","author":"Wong","year":"2009","journal-title":"Arch Ophthalmol"},{"key":"B9","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1016\/j.jcrs.2014.06.036","article-title":"Prevention and management of collagen copolymer phakic intraocular lens exchange: causes and surgical techniques","volume":"41","author":"Zeng","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"B10","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/S0161-6420(02)01771-2","article-title":"U.S. food and drug administration clinical trial of the implantable contact lens for moderate to high myopia","volume":"2","author":"Sanders","year":"2003","journal-title":"Ophthalmology"},{"key":"B11","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1001\/archopht.121.5.633","article-title":"Ultrasonographic biomicroscopy, scheimpflug photography, and novel provocative tests in contralateral eyes of chinese patients initially seen with acute angle closure","volume":"121","author":"Friedman","year":"2003","journal-title":"Arch Ophthalmol"},{"key":"B12","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1016\/S0161-6420(02)01748-7","article-title":"Age, gender, biometry, refractive error, and the anterior chamber angle among alaskan eskimos","volume":"110","author":"Wojciechowski","year":"2003","journal-title":"Ophthalmology"},{"key":"B13","doi-asserted-by":"publisher","first-page":"506","DOI":"10.1097\/IJG.0b013e318193c141","article-title":"Potential of the pentacam in screening for primary angle closure and primary angle closure suspect","volume":"18","author":"Kurita","year":"2009","journal-title":"J Glaucoma"},{"key":"B14","doi-asserted-by":"publisher","first-page":"1985","DOI":"10.1016\/j.ophtha.2013.05.034","article-title":"Evaluation of the anterior chamber angle in glaucoma: a report by the american academy of ophthalmology","volume":"120","author":"Smith","year":"2013","journal-title":"Ophthalmology"},{"key":"B15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2016\/7012826","article-title":"Anterior chamber angle evaluation following phakic posterior chamber collamer lens with CentraFLOW and its correlation with ICL vault and intraocular pressure","volume":"2016","author":"Eissa","year":"2016","journal-title":"J Ophthalmol"},{"key":"B16","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1177\/1120672118766445","article-title":"Implanting a posterior chamber phakic intraocular lens in highly myopic eyes with peripheral primary iris and ciliary body cysts","volume":"29","author":"Zhao","year":"2019","journal-title":"Eur J Ophthalmol"},{"key":"B17","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/S0161-6420(00)00403-6","article-title":"Safety of posterior chamber phakic intraocular lenses for the correction of high myopia","volume":"108","author":"Jim\u00e9nez-Alfaro","year":"2001","journal-title":"Ophthalmology"},{"key":"B18","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1016\/j.ajo.2013.05.018","article-title":"Intraocular pressure after implantation of the visian implantable collamer lens with centra flow without iridotomy","volume":"156","author":"Higueras-Esteban","year":"2013","journal-title":"Am J Ophthalmol"},{"key":"B19","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.2147\/OPTH.S111620","article-title":"Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens","volume":"10","author":"Packer","year":"2016","journal-title":"Clin Ophthalmol"},{"key":"B20","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1136\/bjophthalmol-2017-310518","article-title":"Anterior segment optical coherence tomography angle and vault analysis after toric and non-toric implantable collamer lens V4c implantation in patients with high myopia","volume":"102","author":"Garcia-De la Rosa","year":"2018","journal-title":"Br J Ophthalmol"},{"key":"B21","doi-asserted-by":"publisher","first-page":"e471","DOI":"10.1111\/aos.13846","article-title":"Contralateral eye comparison of the long-term visual quality and stability between implantable collamer lens and laser refractive surgery for myopia","volume":"97","author":"Chen","year":"2019","journal-title":"Acta Ophthalmol"},{"key":"B22","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1167\/iovs.03-0693","article-title":"Safety of iris claw phakic intraocular lenses: an endothelial microscopy long term study","volume":"45","author":"Javaloy","year":"2004","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"B23","doi-asserted-by":"publisher","first-page":"526","DOI":"10.3928\/1081597X-20140711-05","article-title":"Correction of moderate to high hyperopia with an implantable collamer lens: medium-term results","volume":"30","author":"Benda","year":"2014","journal-title":"J Refract Surg"},{"key":"B24","doi-asserted-by":"publisher","first-page":"251","DOI":"10.3928\/1081597X-20090301-03","article-title":"Changes in iridocorneal angle structure and trabecular pigmentation with STAAR implantable collamer lens during 2 years","volume":"25","author":"Chung","year":"2009","journal-title":"J Refract Surg"},{"key":"B25","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.ajo.2015.11.010","article-title":"Effects of implantable collamer lens v4c placement on iridocorneal angle measurements by fourier-domain optical coherence tomography","volume":"162","author":"Fern\u00e1ndez-Vigo","year":"2016","journal-title":"Am J Ophthalmol"},{"key":"B26","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.ajo.2017.06.018","article-title":"Impacts of implantable collamer lens v4c placement on angle measurements made by optical coherence tomography: two-year follow up","volume":"181","author":"Fern\u00e1ndez-Vigo","year":"2017","journal-title":"Am J Ophthalmol"},{"key":"B27","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.ophtha.2011.07.047","article-title":"Correlation between preoperative biometry and posterior chamber phakic visian implantable collamer lens vaulting","volume":"119","author":"Lee","year":"2012","journal-title":"Ophthalmology"},{"key":"B28","doi-asserted-by":"publisher","first-page":"1245","DOI":"10.1016\/j.ophtha.2009.10.033","article-title":"Vaulting of myopic and toric implantable collamer lenses during accommodation measured with visante optical coherence tomography","volume":"117","author":"Lindland","year":"2010","journal-title":"Ophthalmology"},{"key":"B29","doi-asserted-by":"publisher","DOI":"10.1111\/aos.14720","article-title":"Consecutive contralateral comparison of toric and non-toric implantable collamer lenses V4c in vault after implantation for myopia and astigmatism","author":"Zhao","year":"2020","journal-title":"Acta Ophthalmologica"},{"key":"B30","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1186\/s12886-018-0935-7","article-title":"Implantable collamer lens surgery in patients with primary iris and\/or ciliary body cysts","volume":"18","author":"Li","year":"2018","journal-title":"BMC Ophthalmol"}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2021.610590\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,27]],"date-time":"2021-01-27T08:02:57Z","timestamp":1611734577000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2021.610590\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,27]]},"references-count":30,"alternative-id":["10.3389\/fmed.2021.610590"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2021.610590","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,27]]},"article-number":"610590"}}