{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T15:31:42Z","timestamp":1787239902264,"version":"build-2736575974"},"reference-count":26,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,4,1]],"date-time":"2022-04-01T00:00:00Z","timestamp":1648771200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This study aimed to compare the efficacy and safety of corneal refractive therapy (CRT) lenses and vision shaping treatment (VST) lenses for myopia control in children.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Medical records of 1,001 children (2,002 eyes) who had been fitted with orthokeratology lenses for over 1.5 years were retrospectively reviewed. We collected the clinical data of four types of orthokeratology (OK) lenses available: one CRT lens (brand: CRT) and three VST lenses (brands: Euclid, Alpha, and Hiline) over 1.5 years. Results were compared and analyzed using a one-way ANOVA and Pearson's chi-square test.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Axial length elongation in the CRT lens group was 0.13 \u00b1 0.02 mm faster than that in the Euclid lens, 0.1 \u00b1 0.02 mm faster in the Alpha lens, and 0.08 \u00b1 0.02 mm faster in the Hiline lens over the 1.5-year period (all\n                      <jats:italic>P<\/jats:italic>\n                      &amp;lt; 0.05). Among the subjects, 37.3% of them using the CRT lens experienced more than 1 D of refractive growth, compared with 20.2\u201330.8% of subjects wearing the three groups of VST lenses (all\n                      <jats:italic>P<\/jats:italic>\n                      &amp;lt; 0.05). A lower incidence of total adverse events was found with the CRT lenses compared with the VST lenses (\n                      <jats:italic>P<\/jats:italic>\n                      &amp;lt; 0.05), especially corneal staining. No difference was found in axial length elongation, refraction growth, and incidence of adverse events among the three types of VST lenses (all\n                      <jats:italic>P<\/jats:italic>\n                      &amp;gt; 0.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Compared with the VST lenses, CRT lenses demonstrated a weaker effect on myopia control but with a better safety profile. Different types of VST lenses had similar efficacy and safety in the context of controlling myopia progression.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fmed.2022.798314","type":"journal-article","created":{"date-parts":[[2022,4,1]],"date-time":"2022-04-01T01:45:01Z","timestamp":1648777501000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":30,"title":["Comparison of Two Main Orthokeratology Lens Designs in Efficacy and Safety for Myopia Control"],"prefix":"10.3389","volume":"9","author":[{"given":"Weiwei","family":"Lu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rui","family":"Ning","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kai","family":"Diao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Ding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruru","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lei","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Lian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Colm","family":"McAlinden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francis W. B.","family":"Sanders","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fangfang","family":"Xia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinhai","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wanqing","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2022,4,1]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1016\/j.ophtha.2016.01.006","article-title":"Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050","volume":"123","author":"Holden","year":"2016","journal-title":"Ophthalmology."},{"key":"B2","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1136\/bjo.2006.090233","article-title":"Uncorrected refractive error","volume":"90","author":"McCarty","year":"2006","journal-title":"Br J Ophthalmol."},{"key":"B3","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1111\/j.1444-0938.2006.00044.x","article-title":"Orthokeratology review and update","volume":"89","author":"Swarbrick","year":"2006","journal-title":"Clin Exp Optom."},{"key":"B4","doi-asserted-by":"publisher","first-page":"210","DOI":"10.18502\/jovr.v15i2.6739","article-title":"Orthokeratology in moderate myopia: a study of predictability and safety","volume":"15","author":"Singh","year":"2020","journal-title":"J Ophthalmic Vis Res."},{"key":"B5","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1186\/s12886-017-0639-4","article-title":"Effect of orthokeratology on myopia progression: twelve-year results of a retrospective cohort study","volume":"17","author":"Lee","year":"2017","journal-title":"BMC Ophthalmol."},{"key":"B6","doi-asserted-by":"publisher","first-page":"360806","DOI":"10.1155\/2015\/360806","article-title":"Efficacy and acceptability of orthokeratology for slowing myopic progression in children: a systematic review and meta-analysis","volume":"2015","author":"Wen","year":"2015","journal-title":"J Ophthalmol."},{"key":"B7","doi-asserted-by":"publisher","first-page":"3965","DOI":"10.1167\/iovs.05-0445","article-title":"Peripheral vision can influence eye growth and refractive development in infant monkeys","volume":"46","author":"Smith EL","year":"2005","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"B8","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1097\/ICL.0000000000000520","article-title":"The role of orthokeratology in myopia control: a review","volume":"44","author":"Lipson","year":"2018","journal-title":"Eye Contact Lens."},{"key":"B9","doi-asserted-by":"publisher","first-page":"1112","DOI":"10.1097\/OPX.0000000000000889","article-title":"The influence of different OK Lens designs on peripheral refraction","volume":"93","author":"Kang","year":"2016","journal-title":"Optom Vis Sci."},{"key":"B10","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/j.clae.2019.11.012","article-title":"Comparison of four different orthokeratology lenses in controlling myopia progression","volume":"43","author":"Chen","year":"2020","journal-title":"Cont Lens Anterior Eye."},{"key":"B11","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1080\/02713683.2020.1820528","article-title":"The effect of relative corneal refractive power shift distribution on AL growth in myopic children undergoing orthokeratology treatment","volume":"46","author":"Yang","year":"2021","journal-title":"Curr Eye Res."},{"key":"B12","doi-asserted-by":"publisher","first-page":"336","DOI":"10.3390\/jcm10020336","article-title":"The role of back optic zone diameter in myopia control with orthokeratology lenses","volume":"10","author":"Paun\u00e9","year":"2021","journal-title":"J Clin Med."},{"key":"B13","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1097\/ICL.0000000000000219","article-title":"The safety of orthokeratology\u2014a systematic review","volume":"42","author":"Liu","year":"2016","journal-title":"Eye Contact Lens"},{"key":"B14","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1186\/s12886-019-1112-3","article-title":"Efficacy and safety of interventions to control myopia progression in children: an overview of systematic reviews and meta-analyses","volume":"19","author":"Prousali","year":"2019","journal-title":"BMC Ophthalmol."},{"key":"B15","doi-asserted-by":"publisher","first-page":"1133","DOI":"10.1097\/OPX.0b013e318263c5af","article-title":"Orthokeratology vs. spectacles: adverse events and discontinuations","volume":"89","author":"Santodomingo-Rubido","year":"2012","journal-title":"Optom Vis Sci."},{"key":"B16","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/j.clae.2020.08.011","article-title":"The safety of orthokeratology in myopic children and analysis of related factors","volume":"44","author":"Hu","year":"2021","journal-title":"Cont Lens Anterior Eye."},{"key":"B17","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1111\/opo.12460","article-title":"Safety and efficacy following 10-years of overnight orthokeratology for myopia control","volume":"38","author":"Hiraoka","year":"2018","journal-title":"Ophthalmic Physiol Opt."},{"key":"B18","doi-asserted-by":"publisher","first-page":"e0241759","DOI":"10.1371\/journal.pone.0241759","article-title":"Myopia progression varies with age and severity of myopia","volume":"15","author":"Verkicharla","year":"2020","journal-title":"PLoS ONE."},{"key":"B19","unstructured":"2017"},{"key":"B20","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1097\/00006324-199303000-00011","article-title":"CCLRU standards for success of daily and extended wear contact lenses","volume":"70","author":"Terry","year":"1993","journal-title":"Optometry Vis Sci."},{"key":"B21","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1111\/j.1475-1313.2011.00851.x","article-title":"Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology","volume":"31","author":"McAlinden","year":"2011","journal-title":"Ophthalmic Physiol Opt."},{"key":"B22","doi-asserted-by":"publisher","first-page":"7077","DOI":"10.1167\/iovs.12-10565","article-title":"Retardation of myopia in orthokeratology (ROMIO) study: a 2-year randomized clinical trial","volume":"53","author":"Cho","year":"2012","journal-title":"Invest Ophthalmol Vis Sci."},{"key":"B23","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1097\/ICL.0000000000000495","article-title":"Analysis of two orthokeratology lens designs and comparison of their optical effects on the cornea","volume":"44","author":"Marcotte-Collard","year":"2018","journal-title":"Eye Contact Lens."},{"key":"B24","doi-asserted-by":"publisher","first-page":"e000345","DOI":"10.1136\/bmjophth-2019-000345","article-title":"Orthokeratology with increased compression factor (OKIC): study design and preliminary results","volume":"5","author":"Wan","year":"2020","journal-title":"BMJ Open Ophthalmol."},{"key":"B25","doi-asserted-by":"publisher","first-page":"600","DOI":"10.3109\/02713683.2015.1050743","article-title":"Efficacy, safety and acceptability of orthokeratology on slowing axial elongation in myopic children by meta-analysis","volume":"41","author":"Li","year":"2016","journal-title":"Curr Eye Res."},{"key":"B26","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1097\/01.opx.0000168562.64251.66","article-title":"The effects of high-Dk rigid contact lens center thickness, material permeability, and blinking on the oxygen uptake of the human cornea","volume":"82","author":"Gardner","year":"2005","journal-title":"Optom Vis Sci."}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2022.798314\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,1]],"date-time":"2022-04-01T01:45:09Z","timestamp":1648777509000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2022.798314\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,1]]},"references-count":26,"alternative-id":["10.3389\/fmed.2022.798314"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2022.798314","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,1]]},"article-number":"798314"}}