{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T16:11:53Z","timestamp":1769184713231,"version":"3.49.0"},"reference-count":27,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2022,4,11]],"date-time":"2022-04-11T00:00:00Z","timestamp":1649635200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100014137","name":"Shanghai Shenkang Hospital Development Center","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100014137","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100018625","name":"Science and Technology Innovation Plan Of Shanghai Science and Technology Commission","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100018625","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:sec><jats:title>Purpose<\/jats:title><jats:p>This study aimed to investigate the influence of intraocular lens (IOL) weight on long-term IOL stability in highly myopic eyes.<\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and Methods<\/jats:title><jats:p>A total of 205 highly myopic cataract eyes of 205 patients implanted with the MC X11 ASP (Group A, 86 eyes) or 920H IOL (Group B, 119 eyes) were included in this retrospective study. Eyes were divided into 3 subgroups according to the IOL power: low (\u2265-5 to &amp;lt;5 D), medium (\u22655 to &amp;lt;14 D), and high (\u226514 D) IOL power. At 3 years after surgery, IOL decentration and tilt, high-order aberrations, and anterior capsular opening (ACO) area were measured. The influence of IOL weight on long-term IOL stability was evaluated.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Group B had a significantly greater IOL weight than Group A (Group B vs. Group A: 28.31 \u00b1 2.01 mg vs. 25.71 \u00b1 4.62 mg, <jats:italic>P<\/jats:italic> &amp;lt; 0.001). Correspondingly, Group B presented significantly greater overall and inferior decentration than Group A, especially for low and medium IOL power (all <jats:italic>P<\/jats:italic> &amp;lt; 0.05). In both groups, overall and vertical decentration was significantly correlated with IOL weight (all <jats:italic>P<\/jats:italic> &amp;lt; 0.05). Group B showed a significantly greater ACO area than Group A (<jats:italic>P<\/jats:italic> &amp;lt; 0.05). Multivariate analysis showed that decentration in Group A was affected by IOL weight, while decentration in Group B was affected by IOL weight and AL.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Higher IOL weight may lead to greater long-term IOL decentration in highly myopic eyes, while the haptic design may play a role in anterior capsular contraction.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fmed.2022.835475","type":"journal-article","created":{"date-parts":[[2022,4,11]],"date-time":"2022-04-11T05:39:05Z","timestamp":1649655545000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":5,"title":["Influence of IOL Weight on Long-Term IOL Stability in Highly Myopic Eyes"],"prefix":"10.3389","volume":"9","author":[{"given":"Yuxi","family":"Chen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiaqi","family":"Meng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kaiwen","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiang","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ling","family":"Wei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yi","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiangjia","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2022,4,11]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1016\/j.ophtha.2016.01.006","article-title":"Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050","volume":"123","author":"Holden","year":"2016","journal-title":"Ophthalmology."},{"key":"B2","doi-asserted-by":"publisher","first-page":"1655","DOI":"10.1016\/j.ophtha.2021.03.029","article-title":"Comparison of myopic progression before, during, and after COVID-19 lockdown","volume":"128","author":"Chang","year":"2021","journal-title":"Ophthalmology."},{"key":"B3","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1038\/s41433-018-0076-5","article-title":"Patient outcomes following implantation with a trifocal toric IOL: twelve-month prospective multicentre study","volume":"33","author":"Piovella","year":"2019","journal-title":"Eye."},{"key":"B4","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.ajo.2016.12.009","article-title":"A multicenter prospective cohort study on refractive surgery in 15 011 eyes","volume":"175","author":"Kamiya","year":"2017","journal-title":"Am J Ophthalmol."},{"key":"B5","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1111\/cge.12309","article-title":"Homozygous loss-of-function mutation of the LEPREL1 gene causes severe non-syndromic high myopia with early-onset cataract","volume":"86","author":"Guo","year":"2014","journal-title":"Clin Genet."},{"key":"B6","doi-asserted-by":"publisher","first-page":"1473","DOI":"10.1097\/j.jcrs.0000000000000664","article-title":"Efficacy and complications of cataract surgery in high myopia","volume":"47","author":"Yao","year":"2021","journal-title":"J Cataract Refract Surg."},{"key":"B7","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1159\/000504716","article-title":"Correlative comparison of three ocular axes to tilt and decentration of intraocular lens and their effects on visual acuity","volume":"63","author":"Zhang","year":"2020","journal-title":"Ophthalmic Res."},{"key":"B8","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1007\/s10384-020-00737-0","article-title":"Impact of vitrectomy and air tamponade on aspheric intraocular lens tilt and decentration and ocular higher-order aberrations: phacovitrectomy versus cataract surgery","volume":"64","author":"Iwama","year":"2020","journal-title":"Jpn J Ophthalmol."},{"key":"B9","doi-asserted-by":"publisher","first-page":"805706","DOI":"10.1155\/2015\/805706","article-title":"Epidemiology, Etiology, and Prevention of Late IOL-Capsular Bag Complex Dislocation: Review of the Literature","volume":"2015","author":"Ascaso","year":"2015","journal-title":"J Ophthalmol."},{"key":"B10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ajo.2018.01.007","article-title":"Inferior decentration of multifocal intraocular lenses in myopic eyes","volume":"188","author":"Zhu","year":"2018","journal-title":"Am J Ophthalmol."},{"key":"B11","doi-asserted-by":"publisher","first-page":"8676451","DOI":"10.1155\/2018\/8676451","article-title":"The effect of anterior capsule polishing on capsular contraction and lens stability in cataract patients with high myopia","volume":"2018","author":"Wang","year":"2018","journal-title":"J Ophthalmol."},{"key":"B12","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/s40662-021-00245-3","article-title":"Lens thickness and associated ocular biometric factors among cataract patients in Shanghai","volume":"8","author":"Meng","year":"2021","journal-title":"Eye Vis."},{"key":"B13","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.ajo.2021.08.017","article-title":"Clinically significant intraocular lens decentration and tilt in highly myopic eyes: a swept-source optical coherence tomography study","volume":"235","author":"Wang","year":"2022","journal-title":"Am J Ophthalmol."},{"key":"B14","doi-asserted-by":"publisher","first-page":"1126","DOI":"10.1097\/j.jcrs.0000000000000219","article-title":"Characteristics and factors associated with intraocular lens tilt and decentration after cataract surgery","volume":"46","author":"Chen","year":"2020","journal-title":"J Cataract Refract Surg."},{"key":"B15","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1016\/j.ajo.2012.08.019","article-title":"Capsular adhesion to intraocular lens in highly myopic eyes evaluated in vivo using ultralong-scan-depth optical coherence tomography","volume":"155","author":"Zhao","year":"2013","journal-title":"Am J Ophthalmol."},{"key":"B16","doi-asserted-by":"publisher","first-page":"1379","DOI":"10.1038\/sj.eye.6702446","article-title":"Comparison of two acrylic intraocular lenses with different haptic designs in patients with combined phacoemulsification and pars plana vitrectomy","volume":"21","author":"Mingels","year":"2007","journal-title":"Eye."},{"key":"B17","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1186\/s40662-020-00186-3","article-title":"Decentration and tilt of plate-haptic multifocal intraocular lenses in myopic eyes","volume":"7","author":"Meng","year":"2020","journal-title":"Eye Vis."},{"key":"B18","doi-asserted-by":"publisher","first-page":"1510","DOI":"10.1136\/bjophthalmol-2020-317124","article-title":"Impact of intraocular lens characteristics on intraocular lens dislocation after cataract surgery","volume":"105","author":"Mayer-Xanthaki","year":"2020","journal-title":"Br J Ophthalmol."},{"key":"B19","doi-asserted-by":"publisher","first-page":"358","DOI":"10.3928\/1542-8877-19910601-16","article-title":"\u201cEquator ring\u201d for maintenance of the completely circular contour of the capsular bag equator after cataract removal","volume":"22","author":"Hara","year":"1991","journal-title":"Ophthalmic Surg."},{"key":"B20","doi-asserted-by":"publisher","first-page":"898","DOI":"10.1016\/S0886-3350(00)00446-6","article-title":"The capsular tension ring: designs, applications, and techniques","volume":"26","author":"Menapace","year":"2000","journal-title":"J Cataract Refract Surg."},{"key":"B21","doi-asserted-by":"publisher","first-page":"1775","DOI":"10.1016\/j.jcrs.2011.04.035","article-title":"Pre-operative and post-operative size and movements of the lens capsular bag: ultrasound biomicroscopy analysis","volume":"37","author":"Modesti","year":"2011","journal-title":"J Cataract Refract Surg."},{"key":"B22","doi-asserted-by":"publisher","first-page":"332","DOI":"10.3760\/cma.j.issn.04124081.2010.04.011","volume":"46","author":"Xing","year":"2010","journal-title":"Zhonghua Yan Ke Za Zhi."},{"key":"B23","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1016\/j.jcrs.2018.10.049","article-title":"Effects of decentration and tilt on the optical performance of 6 aspheric intraocular lens designs in a model eye","volume":"45","author":"Lawu","year":"2019","journal-title":"J Cataract Refract Surg."},{"key":"B24","doi-asserted-by":"publisher","first-page":"2183","DOI":"10.2147\/IJGM.S301887","article-title":"Stability of various types of aspheric intraocular lenses after implantation: a one-year retrospective study","volume":"14","author":"Ning","year":"2021","journal-title":"Int J Gen Med."},{"key":"B25","doi-asserted-by":"publisher","first-page":"2067","DOI":"10.2147\/OPTH.S64611","article-title":"Evaluating the different laser fragmentation patterns used in laser cataract surgeries in terms of effective phacoemulsification time and power","volume":"9","author":"Huseynova","year":"2015","journal-title":"Clin Ophthalmol."},{"key":"B26","doi-asserted-by":"publisher","first-page":"2158","DOI":"10.1016\/j.jcrs.2004.02.072","article-title":"Influence of intraocular lens tilt and decentration on wavefront aberrations","volume":"30","author":"Taketani","year":"2004","journal-title":"J Cataract Refract Surg."},{"key":"B27","doi-asserted-by":"publisher","first-page":"744","DOI":"10.1016\/j.ajo.2005.04.026","article-title":"Ocular higher-order wavefront aberration caused by major tilting of intraocular lens","volume":"140","author":"Oshika","year":"2005","journal-title":"Am J Ophthalmol."}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2022.835475\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,11]],"date-time":"2022-04-11T05:39:09Z","timestamp":1649655549000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2022.835475\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,11]]},"references-count":27,"alternative-id":["10.3389\/fmed.2022.835475"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2022.835475","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,11]]},"article-number":"835475"}}