{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,18]],"date-time":"2026-04-18T21:20:47Z","timestamp":1776547247040,"version":"3.51.2"},"reference-count":56,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,3,20]],"date-time":"2023-03-20T00:00:00Z","timestamp":1679270400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002865","name":"Chongqing Science and Technology Commission","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002865","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:p>With increasing population aging, osteoporosis vertebral compression fractures (OVCFs), resulting in severe back pain and functional impairment, have become progressively common. Percutaneous vertebroplasty (PVP) and percutaneous kyphoplasty (PKP) as minimally invasive procedures have revolutionized OVCFs treatment. However, PVP- and PKP-related complications, such as symptomatic cement leakage and adjacent vertebral fractures, continue to plague physicians. Consequently, progressively more implants for OVCFs have been developed recently to overcome the shortcomings of traditional procedures. Therefore, we conducted a literature review on several new implants for OVCFs, including StaXx FX, Vertebral Body Stenting, Vesselplasty, Sky Bone Expander, Kiva, Spine Jack, Osseofix, Optimesh, Jack, and V-strut. Additionally, this review highlights the individualized applications of these implants for OVCFs. Nevertheless, current clinical studies on these innovative implants remain limited. Future prospective, randomized, and controlled studies are needed to elucidate the effectiveness and indications of these new implants for OVCFs.<\/jats:p>","DOI":"10.3389\/fmed.2023.1161174","type":"journal-article","created":{"date-parts":[[2023,3,20]],"date-time":"2023-03-20T05:10:22Z","timestamp":1679289022000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":17,"title":["Innovative minimally invasive implants for osteoporosis vertebral compression fractures"],"prefix":"10.3389","volume":"10","author":[{"given":"Yi","family":"Luo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Da-Mei","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hong-Mei","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Di","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Feng-Ying","family":"Xie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2023,3,20]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1007\/s11914-022-00730-1","article-title":"Osteoporosis diagnosis, management, and referral practice after fragility fractures.","volume":"20","author":"Snodgrass","year":"2022","journal-title":"Curr Osteoporosis Rep."},{"key":"B2","doi-asserted-by":"publisher","first-page":"2373","DOI":"10.2147\/jpr.s375119","article-title":"Aworldwide bibliometric analysis of published literature on osteoporosis vertebral compression fracture.","volume":"15","author":"Li","year":"2022","journal-title":"J Pain Res."},{"key":"B3","doi-asserted-by":"publisher","first-page":"1320","DOI":"10.1080\/07853890.2022.2063373","article-title":"Effects of percutaneous vertebroplasty on respiratory parameters in patients with osteoporotic vertebral compression fractures.","volume":"54","author":"Ma","year":"2022","journal-title":"Ann Med."},{"key":"B4","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1016\/s0002-9343(02)01190-7","article-title":"Diagnosis and management of vertebral fractures in elderly adults.","volume":"113","author":"Papaioannou","year":"2002","journal-title":"Am J Med."},{"key":"B5","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-017-0649-1","article-title":"Reduction of vertebral height with fragility vertebral fractures can induce variety of neurological deterioration.","volume":"12","author":"Fujimoto","year":"2017","journal-title":"J Orthopaedic Surg Res."},{"key":"B6","doi-asserted-by":"publisher","DOI":"10.3390\/geriatrics7060123","article-title":"Clinical characteristics of elderly people with osteoporotic vertebral compression fracture based on a 12-year single-center experience in Korea.","volume":"7","author":"Lee","year":"2022","journal-title":"Geriatrics."},{"key":"B7","doi-asserted-by":"publisher","DOI":"10.3389\/fsurg.2022.942195","article-title":"Treatment of elderly patients with acute symptomatic OVCF: a study of comparison of conservative treatment and percutaneous kyphoplasty.","volume":"9","author":"Yu","year":"2022","journal-title":"Front Surg."},{"key":"B8","article-title":"Preliminary note on treatment of vertebral angiomas using percutaneous acrylic vertebroplasty.","volume":"32","author":"Galibert","year":"1986","journal-title":"Neurochirurgie."},{"key":"B9","doi-asserted-by":"publisher","first-page":"564","DOI":"10.5312\/wjo.v13.i6.564","article-title":"Managements of osteoporotic vertebral compression fractures: a narrative review.","volume":"13","author":"Patel","year":"2022","journal-title":"World J Orthopedics."},{"key":"B10","doi-asserted-by":"publisher","first-page":"1511","DOI":"10.1097\/00007632-200107150-00002","article-title":"New technologies in spine - kyphoplasty and vertebrosplasty for the treatment of painful osteoporotic compression fractures.","volume":"26","author":"Garfin","year":"2001","journal-title":"Spine."},{"key":"B11","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1016\/j.pmr.2022.01.008","article-title":"Vertebroplasty and kyphoplasty.","volume":"33","author":"Boss","year":"2022","journal-title":"Phys Med Rehabil Clin N Am."},{"key":"B12","doi-asserted-by":"publisher","first-page":"1295","DOI":"10.3174\/ajnr.A2484","article-title":"Restoration of spinal alignment and disk mechanics following polyetheretherketone wafer kyphoplasty with StaXx FX.","volume":"32","author":"Renner","year":"2011","journal-title":"Am J Neuroradiol."},{"key":"B13","doi-asserted-by":"publisher","first-page":"S445","DOI":"10.1007\/s00586-011-2053-6","article-title":"Treatment of an osteoporotic vertebral compression fracture with the StaXx FX system resulting in intrathoracic wafers: a serious complication.","volume":"21","author":"van der Plaat","year":"2012","journal-title":"Eur Spine J Off Publ Eur Spine Soc Eur Spinal Deformity Soc Eur Sec Cervical Spine Res Soc."},{"key":"B14","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1007\/s00132-001-0275-8","article-title":"Vertebral body stenting. A method for repositioning and augmenting vertebral body compression fractures.","volume":"31","author":"Furderer","year":"2002","journal-title":"Orthopade."},{"key":"B15","doi-asserted-by":"publisher","first-page":"916","DOI":"10.1007\/s00586-010-1341-x","article-title":"Vertebral body stenting: a new method for vertebral augmentation versus kyphoplasty.","volume":"19","author":"Rotter","year":"2010","journal-title":"Eur Spine J."},{"key":"B16","doi-asserted-by":"publisher","first-page":"1038","DOI":"10.1016\/j.injury.2011.04.006","article-title":"Early results after vertebral body stenting for fractures of the anterior column of the thoracolumbar spine.","volume":"42","author":"Klezl","year":"2011","journal-title":"Injury Int J Care Injured."},{"key":"B17","doi-asserted-by":"publisher","first-page":"161","DOI":"10.3109\/13645706.2014.962546","article-title":"Two-year results of vertebral body stenting for the treatment of traumatic incomplete burst fractures.","volume":"24","author":"Hartmann","year":"2015","journal-title":"Minim Invasive Ther Allied Technol."},{"key":"B18","doi-asserted-by":"publisher","first-page":"1608","DOI":"10.1007\/s00586-012-2603-6","article-title":"Surgical procedure and initial radiographic results of a new augmentation technique for vertebral compression fractures.","volume":"22","author":"Thaler","year":"2013","journal-title":"Eur Spine J."},{"key":"B19","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/j.neuchi.2014.05.004","article-title":"Should we fear cement leakage during kyphoplasty in percutaneous traumatic spine surgery? A single experience with 76 consecutive cases.","volume":"60","author":"Capel","year":"2014","journal-title":"Neurochirurgie."},{"key":"B20","doi-asserted-by":"publisher","first-page":"577","DOI":"10.2106\/jbjs.l.00024","article-title":"Vertebral body stenting versus kyphoplasty for the treatment of osteoporotic vertebral compression fractures a randomized trial.","author":"Werner","year":"2013","journal-title":"J Bone Joint Surg Am Vol."},{"key":"B21","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1111\/1754-9485.13067","article-title":"Cone-beam computed tomography guided unipedicular central stentoplasty of the thoracolumbar spine: early technical experience and results.","volume":"64","author":"Huang","year":"2020","journal-title":"J Med Imag Radiat Oncol."},{"key":"B22","doi-asserted-by":"publisher","first-page":"2602","DOI":"10.1007\/s00586-018-5717-7","article-title":"Is vertebral body stenting in combination with cap cement superior to kyphoplasty?","volume":"27","author":"Schutzenberger","year":"2018","journal-title":"Eur Spine J."},{"key":"B23","doi-asserted-by":"publisher","first-page":"218","DOI":"10.2214\/ajr.08.1503","article-title":"Vesselplasty: a new technical approach to treat symptomatic vertebral compression fractures.","volume":"193","author":"Flors","year":"2009","journal-title":"Am J Roentgenol."},{"key":"B24","doi-asserted-by":"publisher","DOI":"10.1080\/02688697.2020.1862054","article-title":"Vesselplasty for the treatment of osteoporotic vertebral compression fractures with peripheral wall damage: a retrospective study.","author":"Chen","year":"2020","journal-title":"Br J Neurosurg."},{"key":"B25","doi-asserted-by":"publisher","DOI":"10.1177\/03000605211066303","article-title":"Vesselplasty versus vertebroplasty in the treatment of osteoporotic vertebral compression fractures with posterior wall rupture.","volume":"49","author":"Xu","year":"2021","journal-title":"J Int Med Res."},{"key":"B26","doi-asserted-by":"publisher","first-page":"9509","DOI":"10.1299841\/wjcc\/v.i31.9509","article-title":"Outcomes of different minimally invasive surgical treatments for vertebral compression fractures: an observational study.","volume":"9","author":"Yeh","year":"2021","journal-title":"World J Clin Cases."},{"key":"B27","doi-asserted-by":"publisher","first-page":"1092","DOI":"10.1016\/j.spinee.2013.06.094","article-title":"Height restoration of osteoporotic vertebral compression fractures using different intravertebral reduction devices: a cadaveric study.","volume":"15","author":"Krueger","year":"2015","journal-title":"Spine J."},{"key":"B28","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/173872","article-title":"Clinical performance and safety of 108 SpineJack implantations: 1-year results of a prospective multicentre single-arm registry study.","volume":"2015","author":"Noriega","year":"2015","journal-title":"Biomed Res Int."},{"key":"B29","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1016\/j.otsr.2015.08.009","article-title":"Treatment of vertebral compression fractures with the cranio-caudal expandable implant SpineJack\u00ae : technical note and outcomes in 77 consecutive patients.","volume":"101","author":"Renaud","year":"2015","journal-title":"Orthopaedics Traumatol Surg Res."},{"key":"B30","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.13839","article-title":"Re-expansion and stabilization of vertebra plana fractures using bilateral Spine Jack\u00ae implants.","volume":"13","author":"Joyce","year":"2021","journal-title":"Cureus."},{"key":"B31","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1136\/neurintsurg-2021-017682","article-title":"Use of the SpineJack direct reduction for treating type A2, A3 and A4 fractures of the thoracolumbar spine: a retrospective case series.","volume":"14","author":"Lofrese","year":"2021","journal-title":"J Neurointervent Surg."},{"key":"B32","doi-asserted-by":"publisher","first-page":"474","DOI":"10.2478\/folmed-2018-0011","article-title":"Adjacent single-level combined fixation using kyphoplasty and percutaneous pedicle screws in type A3 unstable vertebral fractures in elderly patients.","volume":"60","author":"Ortin-Barcelo","year":"2018","journal-title":"Folia Med."},{"key":"B33","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/j.jvir.2021.10.002","article-title":"Expandable intravertebral implant in cancer-related vertebral compression fractures: a retrospective review of 36 implantations.","volume":"33","author":"Cornelis","year":"2022","journal-title":"J Vasc Intervent Radiol."},{"key":"B34","doi-asserted-by":"publisher","first-page":"101","DOI":"10.4103\/fjs.fjs_5_20","article-title":"Comparison of an intravertebral reduction device and percutaneous vertebroplasty for anatomical reduction with single-level vertebral compression fractures.","volume":"53","author":"Huang","year":"2020","journal-title":"Formosan J Surg."},{"key":"B35","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1007\/s00198-018-4773-5","article-title":"Long-term safety and clinical performance of kyphoplasty and SpineJack\u00ae procedures in the treatment of osteoporotic vertebral compression fractures: a pilot, monocentric, investigator-initiated study.","volume":"30","author":"Noriega","year":"2019","journal-title":"Osteoporosis Int."},{"key":"B36","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2474-12-206","article-title":"Initial clinical experience with a novel vertebral augmentation system for treatment of symptomatic vertebral compression fractures: a case series of 26 consecutive patients.","volume":"12","author":"Korovessis","year":"2011","journal-title":"BMC Musculoskelet Disord."},{"key":"B37","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1016\/j.esas.2011.06.001","article-title":"Vertebral augmentation treatment of painful osteoporotic compression fractures with the Kiva VCF treatment system.","volume":"5","author":"Olivarez","year":"2011","journal-title":"SAS J."},{"key":"B38","doi-asserted-by":"publisher","first-page":"865","DOI":"10.1097\/brs.0000000000000906","article-title":"Kast study: the Kiva system as a vertebral augmentation treatment-a safety and effectiveness trial a randomized, noninferiority trial comparing the Kiva system with balloon kyphoplasty in treatment of osteoporotic vertebral compression fractures.","volume":"40","author":"Tutton","year":"2015","journal-title":"Spine."},{"key":"B39","doi-asserted-by":"crossref","first-page":"E505","DOI":"10.36076\/ppj.2013\/16\/E505","article-title":"Comparison of balloon kyphoplasty with the new Kiva\u00ae VCF system for the treatment of vertebral compression fractures.","volume":"16","author":"Otten","year":"2013","journal-title":"Pain Physician."},{"key":"B40","first-page":"E299","article-title":"Economic analysis of Kiva VCF treatment system compared to balloon kyphoplasty using randomized kiva safety and effectiveness trial (Kast) data.","volume":"18","author":"Beall","year":"2015","journal-title":"Pain Physician."},{"key":"B41","doi-asserted-by":"publisher","first-page":"1783","DOI":"10.1097\/BRS.0b013e3181b7cc5d","article-title":"Biomechanical comparison of kyphoplasty versus a titanium mesh implant with cement for stabilization of vertebral compression fractures.","volume":"35","author":"Upasani","year":"2010","journal-title":"Spine."},{"key":"B42","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1055\/s-0033-1355504","article-title":"Osseofix\u00ae system for percutaneous stabilization of osteoporotic and tumorous vertebral compression fractures - clinical and radiological results after 12 months.","volume":"186","author":"Ender","year":"2014","journal-title":"Rofo."},{"key":"B43","doi-asserted-by":"publisher","DOI":"10.1051\/sicotj\/2021026","article-title":"The outcome of expandable titanium mesh implants for the treatment of multi-level vertebral compression fractures caused by multiple myeloma.","volume":"7","author":"Gandham","year":"2021","journal-title":"SICOT J."},{"key":"B44","doi-asserted-by":"publisher","first-page":"E768","DOI":"10.1097\/BRS.0b013e3181d260bf","article-title":"An evaluation of fracture stabilization comparing kyphoplasty and titanium mesh repair techniques for vertebral compression fractures is bone cement necessary?","volume":"35","author":"Ghofrani","year":"2010","journal-title":"Spine."},{"key":"B45","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/853897","article-title":"Cementless fixation of osteoporotic VCFS using titanium mesh implants (Osseofix): preliminary results.","volume":"2014","author":"Eschler","year":"2014","journal-title":"Biomed Res Int."},{"key":"B46","doi-asserted-by":"publisher","first-page":"1025","DOI":"10.1097\/01.rvi.0000222660.02990.27","article-title":"\u201cSkyphoplasty\u201d: a single institution\u2019s initial experience.","volume":"17","author":"Tong","year":"2006","journal-title":"J Vasc Intervent Radiol."},{"key":"B47","doi-asserted-by":"publisher","first-page":"1944","DOI":"10.1007\/s00586-007-0438-3","article-title":"Results, experience and technical points learnt with use of the sky bone expander kyphoplasty system for osteoporotic vertebral compression fractures: a prospective study of 40 patients with a minimum of 12 months of follow-up.","volume":"16","author":"Foo","year":"2007","journal-title":"Eur Spine J."},{"key":"B48","first-page":"287","article-title":"Percutaneous vertebral augmentation and reconstruction with an intravertebral mesh and morcelized bone graft.","volume":"14","author":"Chiu","year":"2005","journal-title":"Surg Technol Int."},{"key":"B49","doi-asserted-by":"publisher","DOI":"10.3171\/foc.2005.18.3.11","article-title":"Novel percutaneous system for bone graft delivery and containment for elevation and stabilization of vertebral compression fractures. Technical note.","volume":"18","author":"Lam","year":"2005","journal-title":"Neurosurg Focus."},{"key":"B50","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1016\/j.jocn.2006.08.016","article-title":"Flexion-distraction injury of the L1 vertebra treated with short-segment posterior fixation and optimesh.","volume":"15","author":"Inamasu","year":"2008","journal-title":"J Clin Neurosci."},{"key":"B51","doi-asserted-by":"publisher","first-page":"E640","DOI":"10.1097\/BRS.0b013e3181b1fed8","article-title":"Biomechanical evaluation of the vertebral Jack tool and the inflatable bone tamp for reduction of osteoporotic spine fractures.","volume":"34","author":"Sietsma","year":"2009","journal-title":"Spine."},{"key":"B52","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-016-0371-4","article-title":"Evaluation of Surgical outcome of Jack vertebral dilator kyphoplasty for osteoporotic vertebral compression fracture-clinical experience of 218 cases.","volume":"11","author":"Fan","year":"2016","journal-title":"J Orthopaedic Surg Res."},{"key":"B53","doi-asserted-by":"publisher","first-page":"1282","DOI":"10.1302\/0301-620x.92b9.23739","article-title":"Prospective comparative study of kyphoplasty using the Jack vertebral dilator and balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures.","author":"Shen","year":"2010","journal-title":"J Bone Joint Surg Br Vol."},{"key":"B54","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.clinbiomech.2018.05.001","article-title":"Comparative biomechanical study of a new transpedicular vertebral device and vertebroplasty for the treatment or prevention of vertebral compression fractures.","volume":"56","author":"Aebi","year":"2018","journal-title":"Clin Biomech."},{"key":"B55","doi-asserted-by":"publisher","first-page":"642","DOI":"10.1007\/s00270-020-02719-8","article-title":"Percutaneous transpedicular fixation by peek polymer implants combined with cementoplasty for vertebral compression fractures: a pilot study.","volume":"44","author":"Cornelis","year":"2021","journal-title":"Cardiovas Intervent Radiol."},{"key":"B56","doi-asserted-by":"publisher","DOI":"10.3390\/medicina57090907","article-title":"Percutaneous image-guided vertebral fixation in cancer-related vertebral compression fractures: a case series study.","volume":"57","author":"Cornelis","year":"2021","journal-title":"Medicina Lithuania."}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2023.1161174\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,20]],"date-time":"2023-03-20T05:10:28Z","timestamp":1679289028000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2023.1161174\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,20]]},"references-count":56,"alternative-id":["10.3389\/fmed.2023.1161174"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2023.1161174","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,20]]},"article-number":"1161174"}}