{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T06:31:46Z","timestamp":1793169106331,"version":"4.5.0"},"reference-count":27,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T00:00:00Z","timestamp":1696896000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:sec><jats:title>Purpose<\/jats:title><jats:p>To compare the measurement accuracy of new\/updated intraocular lens (IOL) power calculation methods, namely, Kane, Emmetropia Verifying Optical (EVO), with existing methods (Barrett Universal II, Olsen, Haigis, Hoffer Q, Holladay 1, SRK\/T) in Chinese eyes with axial lengths \u2264 22.5 mm.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The study included data from patients who underwent uneventful cataract surgery with the insertion of ZCB00 IOL. Refractive prediction errors were determined by calculating the difference between postoperative refraction and the predicted refraction using each formula. Various parameters were evaluated, including mean prediction error (ME), mean absolute error (MAE), median absolute error (MedAE), and the percentage of eyes with prediction errors (PE) within different ranges.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The study enrolled 38 eyes of 38 patients, and the Barrett Universal II formula demonstrated the lowest MAE and MedAE among the tested formulas. <jats:italic>Post hoc<\/jats:italic> analysis using Wilcoxon signed-rank pairwise comparisons for non-parametric samples with Bonferroni correction revealed no significant difference in postoperative refractive prediction among all the formulas (<jats:italic>P<\/jats:italic> &amp;gt; 0.05). The percentage of eyes with PE within \u00b1 0.5 D was as follows: Barrett Universal II, 81.58%; Haigis, 78.95%; EVO, 76.32%; Olsen, 76.32%; Holladay I, 73.68%; SRK\/T, 71.05%; Kane, 68.42%; and Hoffer Q, 65.79%.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The Barrett Universal II formula was more accurate than the other formulas for Chinese eyes with AL \u2264 22.5 mm.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fmed.2023.1257873","type":"journal-article","created":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T07:15:15Z","timestamp":1696922115000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":9,"title":["Accuracy of new intraocular lens calculation formulas in Chinese eyes with short axial lengths"],"prefix":"10.3389","volume":"10","author":[{"given":"Yueting","family":"Ma","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongdong","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuancun","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhuoyi","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kunliang","family":"Qiu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2023,10,10]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1016\/s0002-9394(98)00113-5","article-title":"Partial coherence interferometry: a novel approach to biometry in cataract surgery.","volume":"126","author":"Drexler","year":"1998","journal-title":"Am J Ophthalmol."},{"key":"B2","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1016\/j.jcrs.2018.01.031","article-title":"Risk factors for refractive error after cataract surgery: analysis of 282 811 cataract extractions reported to the European registry of quality outcomes for cataract and refractive surgery.","volume":"44","author":"Lundstrom","year":"2018","journal-title":"J Cataract Refract Surg."},{"key":"B3","doi-asserted-by":"publisher","first-page":"e94","DOI":"10.1016\/j.ophtha.2020.08.010","article-title":"Intraocular lens power formulas, biometry, and intraoperative aberrometry: a review.","volume":"128","author":"Kane","year":"2021","journal-title":"Ophthalmology."},{"key":"B4","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1016\/j.ophtha.2020.10.031","article-title":"Intraocular lens power calculation in eyes with previous excimer laser surgery for myopia: a report by the American academy of ophthalmology.","volume":"128","author":"Pantanelli","year":"2021","journal-title":"Ophthalmology."},{"key":"B5","doi-asserted-by":"publisher","first-page":"892","DOI":"10.1016\/j.jcrs.2017.07.004","article-title":"Intraocular lens power calculations in short eyes using 7 formulas.","volume":"43","author":"G\u00f6kce","year":"2017","journal-title":"J Cataract Refract Surg."},{"key":"B6","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1136\/bjophthalmol-2020-318272","article-title":"Project hyperopic power prediction: accuracy of 13 different concepts for intraocular lens calculation in short eyes.","volume":"106","author":"Wendelstein","year":"2022","journal-title":"Br J Ophthalmol."},{"key":"B7","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1016\/s0886-3350(13)80338-0","article-title":"The hoffer q formula: a comparison of theoretic and regression formulas.","volume":"19","author":"Hoffer","year":"1993","journal-title":"J Cataract Refract Surg."},{"key":"B8","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/s0886-3350(13)80705-5","article-title":"Development of the Srk\/T intraocular lens implant power calculation formula.","volume":"16","author":"Retzlaff","year":"1990","journal-title":"J Cataract Refract Surg."},{"key":"B9","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/s0886-3350(88)80059-2","article-title":"A three-part system for refining intraocular lens power calculations.","volume":"14","author":"Holladay","year":"1988","journal-title":"J Cataract Refract Surg."},{"key":"B10","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1007\/s004170000188","article-title":"Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to haigis.","volume":"238","author":"Haigis","year":"2000","journal-title":"Graefes Arch Clin Exp Ophthalmol."},{"key":"B11","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.ophtha.2017.08.027","article-title":"Accuracy of intraocular lens calculation formulas.","volume":"125","author":"Melles","year":"2018","journal-title":"Ophthalmology."},{"key":"B12","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1016\/j.jcrs.2005.12.139","article-title":"Prediction of the effective postoperative (intraocular lens) anterior chamber depth.","volume":"32","author":"Olsen","year":"2006","journal-title":"J Cataract Refract Surg."},{"key":"B13","doi-asserted-by":"publisher","first-page":"1334","DOI":"10.1016\/j.ophtha.2019.04.011","article-title":"Update on Intraocular Lens Calculation Formulas.","volume":"126","author":"Melles","year":"2019","journal-title":"Ophthalmology."},{"key":"B14","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.jcrs.2019.08.044","article-title":"Comparison of formula accuracy for intraocular lens power calculation based on measurements by a swept-source optical coherence tomography optical biometer.","volume":"46","author":"Savini","year":"2020","journal-title":"J Cataract Refract Surg."},{"key":"B15","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.jcrs.2019.08.014","article-title":"Assessment of the accuracy of new and updated intraocular lens power calculation formulas in 10 930 eyes from the UK National Health Service.","volume":"46","author":"Darcy","year":"2020","journal-title":"J Cataract Refract Surg."},{"key":"B16","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1038\/s41433-021-01890-7","article-title":"Comparison of the Barrett Universal Ii, Kane and Vrf-G formulas with existing intraocular lens calculation formulas in eyes with short axial lengths.","volume":"37","author":"Voytsekhivskyy","year":"2023","journal-title":"Eye."},{"key":"B17","doi-asserted-by":"publisher","first-page":"1203","DOI":"10.4103\/ijo.IJO_2014_21","article-title":"Comparison of newer kane formula with sanders Retzlaff Kraff\/theoretical and Barrett Universal ii for calculation of intraocular lens power in Indian eyes.","volume":"70","author":"Paritekar","year":"2022","journal-title":"Indian J Ophthalmol."},{"key":"B18","doi-asserted-by":"publisher","first-page":"2981","DOI":"10.1177\/1120672120980690","article-title":"Intraocular lens power calculation formula accuracy: comparison of 12 formulas for a trifocal hydrophilic intraocular lens.","volume":"31","author":"Rocha-de-Lossada","year":"2021","journal-title":"Eur J Ophthalmol."},{"key":"B19","doi-asserted-by":"publisher","first-page":"4137","DOI":"10.1007\/s10792-021-01966-z","article-title":"A Comparative analysis of 12 intraocular lens power formulas.","volume":"41","author":"Pereira","year":"2021","journal-title":"Int Ophthalmol."},{"key":"B20","doi-asserted-by":"publisher","first-page":"1113","DOI":"10.1097\/j.jcrs.0000000000000958","article-title":"Accuracy of newer intraocular lens power formulas in short and long eyes using sum-of-segments biometry.","volume":"48","author":"Shammas","year":"2022","journal-title":"J Cataract Refract Surg."},{"key":"B21","doi-asserted-by":"publisher","first-page":"e115","DOI":"10.1016\/j.ophtha.2020.07.005","article-title":"Update on intraocular lens power calculation study protocols: the better way to design and report clinical trials.","volume":"128","author":"Hoffer","year":"2021","journal-title":"Ophthalmology."},{"key":"B22","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1016\/j.jcrs.2017.08.003","article-title":"Pursuing perfection in intraocular lens calculations: Iii. Criteria for analyzing outcomes.","volume":"43","author":"Wang","year":"2017","journal-title":"J Cataract Refract Surg."},{"key":"B23","doi-asserted-by":"publisher","first-page":"1157","DOI":"10.1016\/j.jcrs.2016.06.029","article-title":"Comparison of 9 intraocular lens power calculation formulas.","volume":"42","author":"Cooke","year":"2016","journal-title":"J Cataract Refract Surg."},{"key":"B24","doi-asserted-by":"publisher","first-page":"2050","DOI":"10.1016\/j.jcrs.2006.09.009","article-title":"Accuracy of intraocular lens power prediction using the Hoffer Q, Holladay 1, Holladay 2, and Srk\/T formulas.","volume":"32","author":"Narvaez","year":"2006","journal-title":"J Cataract Refract Surg."},{"key":"B25","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1111\/ceo.13058","article-title":"Meta-analysis of accuracy of intraocular lens power calculation formulas in short eyes.","volume":"46","author":"Wang","year":"2018","journal-title":"Clin Exp Ophthalmol."},{"key":"B26","doi-asserted-by":"publisher","DOI":"10.1136\/bmjophth-2018-000251","article-title":"Comparison of the kane formula with existing formulas for intraocular lens power selection.","volume":"4","author":"Connell","year":"2019","journal-title":"BMJ Open Ophthalmol."},{"key":"B27","doi-asserted-by":"publisher","first-page":"1358","DOI":"10.1016\/s0886-3350(02)01976-4","article-title":"Intraocular lens power calculation formulas in Chinese eyes with high axial Myopia.","volume":"29","author":"Tsang","year":"2003","journal-title":"J Cataract Refract Surg."}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2023.1257873\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T07:15:17Z","timestamp":1696922117000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2023.1257873\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,10]]},"references-count":27,"alternative-id":["10.3389\/fmed.2023.1257873"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2023.1257873","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,10,10]]},"article-number":"1257873"}}