{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T18:11:46Z","timestamp":1785521506234,"version":"3.56.0"},"reference-count":85,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,2,13]],"date-time":"2024-02-13T00:00:00Z","timestamp":1707782400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:p>Toric intraocular lenses (IOLs) have been developed to enhance visual acuity impaired by cataracts and correct corneal astigmatism. However, residual astigmatism caused by postoperative rotation of the toric IOL is an important factor affecting visual quality after implantation. To decrease the rotation of the toric IOL, significant advancements have been made in understanding the characteristics of toric IOL rotation, the factors influencing its postoperative rotation, as well as the development of various measurement techniques and interventions to address this issue. It has been established that factors such as the patient\u2019s preoperative refractive status, biological parameters, surgical techniques, postoperative care, and long-term management significantly impact the rotational stability of the toric IOL. Clinicians should adopt a personalized approach that considers these factors to minimize the risk of toric IOL rotation and ensure optimal outcomes for each patient. This article reviews the influence of various factors on toric IOL rotational stability. It discusses new challenges that may be encountered to reduce and intervene with rotation after toric IOL implantation in the foreseeable future.<\/jats:p>","DOI":"10.3389\/fmed.2024.1349496","type":"journal-article","created":{"date-parts":[[2024,2,13]],"date-time":"2024-02-13T04:23:06Z","timestamp":1707798186000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":18,"title":["Insights into the rotational stability of toric intraocular lens implantation: diagnostic approaches, influencing factors and intervention strategies"],"prefix":"10.3389","volume":"11","author":[{"given":"Xuanqiao","family":"Lin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dongmei","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2024,2,13]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1016\/s0002-9394(14)74917-7","article-title":"Biometry of 7,500 cataractous eyes","volume":"90","author":"Hoffer","year":"1980","journal-title":"Am J Ophthalmol"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/s0886-3350(01)01035-5","article-title":"Toric intraocular lens implantation: 100 consecutive cases","volume":"28","author":"Till","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"1411","DOI":"10.1016\/j.jcrs.2011.02.028","article-title":"Results of higher power toric intraocular lens implantation","volume":"37","author":"Hoffmann","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"5960328","DOI":"10.1155\/2021\/5960328","article-title":"Toric intraocular lens implantation in the correction of moderate-to-high corneal astigmatism in cataract patients: clinical efficacy and safety","volume":"2021","author":"Qiu","year":"2021","journal-title":"J Ophthalmol"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"333","DOI":"10.2147\/opth.S28241","article-title":"Visual performance in cataract patients with low levels of postoperative astigmatism: full correction versus spherical equivalent correction","volume":"6","author":"Lehmann","year":"2012","journal-title":"Clin Ophthalmol"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"747","DOI":"10.2147\/opth.S164175","article-title":"Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking","volume":"12","author":"Titiyal","year":"2018","journal-title":"Clin Ophthalmol"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1097\/j.jcrs.0000000000000560","article-title":"Effect of residual astigmatism on uncorrected visual acuity and patient satisfaction in pseudophakic patients","volume":"47","author":"Schallhorn","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"1654","DOI":"10.1016\/j.jcrs.2014.01.044","article-title":"Long-term clinical outcomes of toric intraocular lens implantation in cataract cases with preexisting astigmatism","volume":"40","author":"Miyake","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"374","DOI":"10.3928\/1081597x-20230424-02","article-title":"Rotational stability of a new progressive toric hydrophobic intraocular lens with gradually decreasing cylinder power","volume":"39","author":"Savini","year":"2023","journal-title":"J Refract Surg"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1136\/bjophthalmol-2017-310386","article-title":"Clinical outcomes after implantation of a toric intraocular lens with a transitional conic toric surface","volume":"102","author":"Thomas","year":"2018","journal-title":"Br J Ophthalmol"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1080\/08820538.2016.1247181","article-title":"Combined special capsular tension ring and toric iol implantation for management of astigmatism and high axial myopia with cataracts","volume":"33","author":"Zhao","year":"2018","journal-title":"Semin Ophthalmol"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1016\/j.jcrs.2009.12.027","article-title":"Objective analysis of toric intraocular lens rotation and centration","volume":"36","author":"Wolffsohn","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"796","DOI":"10.1055\/s-0043-100656","article-title":"Evaluation of postoperative astigmatism correction and postoperative rotational stability of two toric intraocular lenses","volume":"234","author":"Grohlich","year":"2017","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1016\/j.jcrs.2017.05.025","article-title":"Evaluation of postoperative toric intraocular lens alignment with anterior segment optical coherence tomography","volume":"43","author":"Lucisano","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"48","DOI":"10.3928\/1081597x-20181204-01","article-title":"Rotational stability and centration of a new toric lens design platform using objective image analysis over 6 months","volume":"35","author":"Bhogal-Bhamra","year":"2019","journal-title":"J Refract Surg"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"2190","DOI":"10.1016\/s0161-6420(99)90504-3","article-title":"Postoperative intraocular lens rotation: a randomized comparison of plate and loop haptic implants","volume":"106","author":"Patel","year":"1999","journal-title":"Ophthalmology"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"618","DOI":"10.1097\/j.jcrs.0000000000000489","article-title":"Anterior capsule coverage and rotational stability of an acrylic toric intraocular lens","volume":"47","author":"Sasaki","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1097\/j.jcrs.0000000000001107","article-title":"Rotational stability of plate-haptic toric intraocular lenses in asian eyes: risk period for intraocular lens rotation and its influencing factors","volume":"49","author":"Ma","year":"2023","journal-title":"J Cataract Refract Surg"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1111\/j.1442-9071.2008.01726.x","article-title":"The analysis of predicted capsular bag diameter using modified model of capsule measuring ring in asians","volume":"36","author":"Kim","year":"2008","journal-title":"Clin Experiment Ophthalmol"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"1423","DOI":"10.4103\/ijo.IJO_73_18","article-title":"Comparative evaluation of two toric intraocular lenses for correcting astigmatism in patients undergoing phacoemulsification","volume":"66","author":"Seth","year":"2018","journal-title":"Indian J Ophthalmol"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"1237","DOI":"10.1016\/s0886-3350(97)80322-7","article-title":"Compression forces of haptics of selected posterior chamber lenses","volume":"23","author":"P\u00e4rssinen","year":"1997","journal-title":"J Cataract Refract Surg"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.jcrs.2011.08.028","article-title":"Rotational stability of a toric intraocular lens: influence of axial length and alignment in the capsular bag","volume":"38","author":"Shah","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"680","DOI":"10.1177\/1120672119834469","article-title":"Comparison of incidence of repositioning surgery to correct misalignment with three toric intraocular lenses","volume":"30","author":"Oshika","year":"2020","journal-title":"Eur J Ophthalmol"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.mjafi.2020.03.014","article-title":"Rotational stability of toric intraocular lenses","volume":"78","author":"Singh","year":"2022","journal-title":"Med J Armed Forces India"},{"key":"ref25","doi-asserted-by":"publisher","first-page":"1353","DOI":"10.1097\/j.jcrs.0000000000000259","article-title":"Comparison of the rotational stability between plate-haptic toric and c-loop haptic toric iols in myopic eyes","volume":"46","author":"Zhu","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-023-06232-9","article-title":"Comparison of clinical outcome after implantation of two toric intraocular lenses with different haptic type: a prospective randomized controlled trial","author":"Sun","year":"2023","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"ref27","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1136\/bjophthalmol-2015-306656","article-title":"Factors influencing 1-year rotational stability of acrysof toric intraocular lenses","volume":"100","author":"Zhu","year":"2016","journal-title":"Br J Ophthalmol"},{"key":"ref28","doi-asserted-by":"publisher","first-page":"1376","DOI":"10.1016\/s0886-3350(99)00204-7","article-title":"Prediction of pseudophakic capsular bag diameter based on biometric variables","volume":"25","author":"Vass","year":"1999","journal-title":"J Cataract Refract Surg"},{"key":"ref29","doi-asserted-by":"publisher","first-page":"935","DOI":"10.1016\/s0886-3350(02)01843-6","article-title":"Early rotational stability of the longer staar toric intraocular lens: fifty consecutive cases","volume":"29","author":"Chang","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"ref30","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1186\/s12886-020-01465-2","article-title":"Early-stage clinical outcomes and rotational stability of tecnis toric intraocular lens implantation in cataract cases with long axial length","volume":"20","author":"He","year":"2020","journal-title":"BMC Ophthalmol"},{"key":"ref31","doi-asserted-by":"publisher","first-page":"1219","DOI":"10.1016\/j.jcrs.2019.05.045","article-title":"Enhancing rotational stability of toric intraocular lenses using a type 2l cionni capsular tension ring in patients with high myopia","volume":"45","author":"Tataru","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"ref32","doi-asserted-by":"publisher","first-page":"1231","DOI":"10.18240\/ijo.2023.08.07","article-title":"Rotational stability of plate haptic toric intraocular lenses after combined 25-gauge vitrectomy and cataract surgery","volume":"16","author":"Buhl","year":"2023","journal-title":"Int J Ophthalmol"},{"key":"ref33","doi-asserted-by":"publisher","first-page":"8053941","DOI":"10.1155\/2020\/8053941","article-title":"Clinical characteristics of intraocular lens dislocation in chinese han populations","volume":"2020","author":"Fan","year":"2020","journal-title":"J Ophthalmol"},{"key":"ref34","doi-asserted-by":"publisher","first-page":"6431438","DOI":"10.1155\/2016\/6431438","article-title":"Axial length of the eyeball is important in secondary dislocation of the intraocular lens, capsular bag, and capsular tension ring complex","volume":"2016","author":"Klysik","year":"2016","journal-title":"J Ophthalmol"},{"key":"ref35","doi-asserted-by":"publisher","first-page":"1022","DOI":"10.1016\/s0886-3350(00)00317-5","article-title":"Astigmatism correction with a foldable toric intraocular lens in cataract patients","volume":"26","author":"Ruhswurm","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"ref36","doi-asserted-by":"publisher","first-page":"1436","DOI":"10.1097\/j.jcrs.0000000000000653","article-title":"Associations between anterior segment parameters and rotational stability of a plate-haptic toric intraocular lens","volume":"47","author":"Yao","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"ref37","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1097\/00055735-200002000-00007","article-title":"Astigmatism and toric intraocular lenses","volume":"11","author":"Novis","year":"2000","journal-title":"Curr Opin Ophthalmol"},{"key":"ref38","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/s40662-021-00245-3","article-title":"Lens thickness and associated ocular biometric factors among cataract patients in shanghai","volume":"8","author":"Meng","year":"2021","journal-title":"Eye Vis (Lond)"},{"key":"ref39","doi-asserted-by":"publisher","first-page":"5309","DOI":"10.1167\/iovs.15-16796","article-title":"Lens position and age: the Central India eye and medical study","volume":"56","author":"Jonas","year":"2015","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref40","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1038\/s41433-019-0521-0","article-title":"Early postoperative rotational stability and its related factors of a single-piece acrylic toric intraocular lens","volume":"34","author":"Li","year":"2020","journal-title":"Eye (Lond)"},{"key":"ref41","doi-asserted-by":"publisher","first-page":"22","DOI":"10.3341\/kjo.2001.15.1.22","article-title":"Predictability for proper capsular tension ring size and intraocular lens size","volume":"15","author":"Dong","year":"2001","journal-title":"Korean J Ophthalmol"},{"key":"ref42","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1097\/icu.0000000000000119","article-title":"Corneal astigmatism analysis for toric intraocular lens implantation: precise measurements for perfect correction","volume":"26","author":"Lee","year":"2015","journal-title":"Curr Opin Ophthalmol"},{"key":"ref43","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1097\/j.jcrs.0000000000000415","article-title":"Comparison of surgical repositioning rates and outcomes for hydrophilic vs hydrophobic single-piece acrylic toric iols","volume":"47","author":"Haripriya","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"ref44","doi-asserted-by":"publisher","first-page":"1325","DOI":"10.1016\/j.ophtha.2018.02.012","article-title":"Comparison of the rotational stability of two toric intraocular lenses in 1273 consecutive eyes","volume":"125","author":"Lee","year":"2018","journal-title":"Ophthalmology"},{"key":"ref45","doi-asserted-by":"publisher","first-page":"573","DOI":"10.18240\/ijo.2017.04.12","article-title":"Long-term rotational stability and visual outcomes of a single-piece hydrophilic acrylic toric iol: a 1.5-year follow-up","volume":"10","author":"Gy\u00f6ngy\u00f6ssy","year":"2017","journal-title":"Int J Ophthalmol"},{"key":"ref46","doi-asserted-by":"publisher","first-page":"4379","DOI":"10.2147\/opth.S285818","article-title":"Rotation characteristics of three toric monofocal intraocular lenses","volume":"14","author":"Kramer","year":"2020","journal-title":"Clin Ophthalmol"},{"key":"ref47","doi-asserted-by":"publisher","first-page":"6699596","DOI":"10.1155\/2022\/6699596","article-title":"Impact of material and lens design on repositioning surgery of toric intraocular lenses: a single-arm meta-analysis","volume":"2022","author":"Wu","year":"2022","journal-title":"J Ophthalmol"},{"key":"ref48","doi-asserted-by":"publisher","first-page":"1275","DOI":"10.1016\/j.jcrs.2019.05.015","article-title":"Rotational stability and refractive outcomes of a single-piece aspheric toric intraocular lens with 4 fenestrated haptics","volume":"45","author":"Savini","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"ref49","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1097\/j.jcrs.0000000000001158","article-title":"Rotational stability of a new toric intraocular lens with an advanced optical profile","volume":"49","author":"Zeilinger","year":"2023","journal-title":"J Cataract Refract Surg"},{"key":"ref50","doi-asserted-by":"publisher","first-page":"15099","DOI":"10.1038\/s41598-021-94293-3","article-title":"Influence of frosted haptics on rotational stability of toric intraocular lenses","volume":"11","author":"Takaku","year":"2021","journal-title":"Sci Rep"},{"key":"ref51","doi-asserted-by":"publisher","first-page":"84","DOI":"10.3928\/1081597x-20171211-01","article-title":"Rotational stability of monofocal and trifocal intraocular toric lenses with identical design and material but different surface treatment","volume":"34","author":"Vandekerckhove","year":"2018","journal-title":"J Refract Surg"},{"key":"ref52","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1016\/j.jcrs.2013.11.039","article-title":"Rotational performance and corneal astigmatism correction during cataract surgery: aspheric toric intraocular lens versus aspheric nontoric intraocular lens with opposite clear corneal incision","volume":"40","author":"Maedel","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"ref53","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1016\/j.jcrs.2017.07.030","article-title":"Comparison of visual outcomes, alignment accuracy, and surgical time between 2 methods of corneal marking for toric intraocular lens implantation","volume":"43","author":"Mayer","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"ref54","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1016\/j.jfo.2017.11.002","article-title":"Toric lens implantation in cataract surgery: automated versus manual horizontal axis marking, analysis of 50 cases","volume":"41","author":"Raucau","year":"2018","journal-title":"J Fr Ophtalmol"},{"key":"ref55","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1016\/j.jcrs.2009.09.021","article-title":"Iris fingerprinting: new method for improving accuracy in toric lens orientation","volume":"36","author":"Osher","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"ref56","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1016\/j.jcrs.2009.11.029","article-title":"Effect of intraoperative aberrometry on the rate of postoperative enhancement: retrospective study","volume":"36","author":"Packer","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"ref57","doi-asserted-by":"publisher","first-page":"e1618","DOI":"10.1097\/md.0000000000001618","article-title":"Comparison between digital and manual marking for toric intraocular lenses: a randomized trial","volume":"94","author":"Elhofi","year":"2015","journal-title":"Medicine (Baltimore)"},{"key":"ref58","doi-asserted-by":"publisher","first-page":"311","DOI":"10.2147\/opth.S178277","article-title":"Consensus on the management of astigmatism in cataract surgery","volume":"13","author":"N\u00fa\u00f1ez","year":"2019","journal-title":"Clin Ophthalmol"},{"key":"ref59","doi-asserted-by":"publisher","first-page":"3020","DOI":"10.4103\/ijo.IJO_465_20","article-title":"Randomized trial comparing visual outcomes of toric intraocular lens implantation using manual and digital marker","volume":"68","author":"Kodavoor","year":"2020","journal-title":"Indian J Ophthalmol"},{"key":"ref60","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.jcrs.2009.10.042","article-title":"Hydroimplantation: foldable intraocular lens implantation without an ophthalmic viscosurgical device","volume":"36","author":"Tak","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"ref61","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1186\/s12886-018-0758-6","article-title":"Comparison of two techniques for toric intraocular lens implantation: Hydroimplantation versus ophthalmic viscosurgical devices","volume":"18","author":"Chen","year":"2018","journal-title":"BMC Ophthalmol"},{"key":"ref62","doi-asserted-by":"publisher","first-page":"1253","DOI":"10.1007\/s00417-005-1181-2","article-title":"Differential responses of human lens epithelial cells to intraocular lenses in vitro: hydrophobic acrylic versus pmma or silicone discs","volume":"243","author":"Yan","year":"2005","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"ref63","doi-asserted-by":"publisher","first-page":"1751","DOI":"10.1016\/j.jcrs.2009.05.024","article-title":"Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens","volume":"35","author":"Saldanha","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"ref64","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1097\/ico.0000000000001124","article-title":"Astigmatism correction with toric intraocular lenses in descemet membrane endothelial keratoplasty triple procedures","volume":"36","author":"Yokogawa","year":"2017","journal-title":"Cornea"},{"key":"ref65","doi-asserted-by":"publisher","first-page":"2687385","DOI":"10.1155\/2018\/2687385","article-title":"Biomaterial influence on intraocular lens performance: an overview","volume":"2018","author":"P\u00e9rez-Vives","year":"2018","journal-title":"J Ophthalmol"},{"key":"ref66","doi-asserted-by":"publisher","first-page":"3001","DOI":"10.2147\/opth.S309214","article-title":"Evaluation of intraocular lens rotational stability in a multicenter clinical trial","volume":"15","author":"Vukich","year":"2021","journal-title":"Clin Ophthalmol"},{"key":"ref67","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1016\/j.ajo.2008.05.040","article-title":"Long-term staar toric intraocular lens rotational stability","volume":"146","author":"Jampaulo","year":"2008","journal-title":"Am J Ophthalmol"},{"key":"ref68","doi-asserted-by":"publisher","first-page":"120","DOI":"10.3928\/1081597x-20221221-02","article-title":"Optimal timing of repositioning surgery for a plate-haptic toric intraocular lens: a multicenter retrospective study","volume":"39","author":"Ma","year":"2023","journal-title":"J Refract Surg"},{"key":"ref69","doi-asserted-by":"publisher","first-page":"411","DOI":"10.4103\/ijo.IJO_875_17","article-title":"Comparative evaluation of rotational stability and visual outcome of toric intraocular lenses with and without a capsular tension ring","volume":"66","author":"Rastogi","year":"2018","journal-title":"Indian J Ophthalmol"},{"key":"ref70","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1080\/08820538.2021.1933545","article-title":"Can toric iol rotation be minimized? Toric iol-capsular tension ring suturing technique and its clinical outcomes","volume":"37","author":"Ucar","year":"2022","journal-title":"Semin Ophthalmol"},{"key":"ref71","doi-asserted-by":"publisher","first-page":"e0228999","DOI":"10.1371\/journal.pone.0228999","article-title":"Effects of capsular tension ring on surgical outcomes of premium intraocular lens in patients with suspected zonular weakness","volume":"15","author":"Miyoshi","year":"2020","journal-title":"PLoS One"},{"key":"ref72","doi-asserted-by":"publisher","first-page":"989","DOI":"10.1007\/s00417-022-05851-y","article-title":"Propensity-matched comparison of postoperative stability and visual outcomes of toric intraocular lens with or without a capsular tension ring and updated meta-analysis","volume":"261","author":"Ma","year":"2023","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"ref73","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.jcro.2015.02.001","article-title":"Use of a capsular tension ring to prevent early postoperative rotation of a toric intraocular lens in high axial myopia","volume":"3","author":"Safran","year":"2015","journal-title":"JCRS Online Case Rep"},{"key":"ref74","doi-asserted-by":"publisher","first-page":"1098","DOI":"10.1016\/j.jcrs.2015.04.004","article-title":"Rotation stability of a toric intraocular lens with a second capsular tension ring","volume":"41","author":"Sagiv","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"ref75","doi-asserted-by":"publisher","first-page":"378","DOI":"10.18240\/ijo.2021.03.07","article-title":"Comparative evaluation of rotational stability of toric iols with four-eyelet vs two-eyelet capsular tension rings in eyes with high myopia","volume":"14","author":"Jiang","year":"2021","journal-title":"Int J Ophthalmol"},{"key":"ref76","doi-asserted-by":"publisher","first-page":"1895","DOI":"10.1016\/j.jcrs.2011.04.036","article-title":"Residual astigmatism produced by toric intraocular lens rotation","volume":"37","author":"Felipe","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"ref77","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/j.ophtha.2017.07.004","article-title":"Incidence and outcomes of repositioning surgery to correct misalignment of toric intraocular lenses","volume":"125","author":"Oshika","year":"2018","journal-title":"Ophthalmology"},{"key":"ref78","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/j.ajo.2020.11.024","article-title":"Refractive and visual outcome of misaligned toric intraocular lens after operative realignment","volume":"224","author":"M\u00fcller-Kassner","year":"2021","journal-title":"Am J Ophthalmol"},{"key":"ref79","doi-asserted-by":"publisher","first-page":"912","DOI":"10.1016\/j.jcrs.2015.04.008","article-title":"Transscleral suture fixation following recurrent toric intraocular lens rotation","volume":"41","author":"Arjmand","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"ref80","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1016\/j.ajo.2008.03.022","article-title":"Femtosecond laser for residual refractive error correction after refractive lens exchange with multifocal intraocular lens implantation","volume":"146","author":"Alfonso","year":"2008","journal-title":"Am J Ophthalmol"},{"key":"ref81","doi-asserted-by":"publisher","first-page":"979","DOI":"10.1016\/j.jcrs.2004.08.054","article-title":"Laser in situ keratomileusis for refractive error after cataract surgery","volume":"31","author":"Kim","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"ref82","doi-asserted-by":"publisher","first-page":"149","DOI":"10.4103\/tjo.tjo_51_18","article-title":"Photorefractive keratectomy for correcting residual refractive error following cataract surgery with premium intraocular lens implantation","volume":"8","author":"Fan","year":"2018","journal-title":"Taiwan J Ophthalmol"},{"key":"ref83","doi-asserted-by":"publisher","first-page":"676","DOI":"10.3928\/1081597x-20130826-01","article-title":"Resolving refractive error after cataract surgery: Iol exchange, piggyback lens, or lasik","volume":"29","author":"Fern\u00e1ndez-Buenaga","year":"2013","journal-title":"J Refract Surg"},{"key":"ref84","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1586\/17469899.2014.966817","article-title":"Corrective techniques and future directions for treatment of residual refractive error following cataract surgery","volume":"9","author":"Moshirfar","year":"2014","journal-title":"Expert Rev Ophthalmol"},{"key":"ref85","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.joco.2017.02.008","article-title":"A review and meta-analysis of corneal cross-linking for post-laser vision correction ectasia","volume":"29","author":"Wan","year":"2017","journal-title":"J Curr Ophthalmol"}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2024.1349496\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,13]],"date-time":"2024-02-13T04:23:09Z","timestamp":1707798189000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2024.1349496\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,13]]},"references-count":85,"alternative-id":["10.3389\/fmed.2024.1349496"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2024.1349496","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,13]]},"article-number":"1349496"}}