{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T17:23:27Z","timestamp":1793294607392,"version":"4.5.0"},"reference-count":57,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,2,7]],"date-time":"2024-02-07T00:00:00Z","timestamp":1707264000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:p>With the widespread application of Implantable Collamer Lens (ICL) implantation surgery in the field of myopia correction, a comprehensive understanding of its potential complications, especially those related to intraocular pressure (IOP), becomes crucial. This article systematically reviews various complications that may lead to IOP elevation after ICL surgery. Firstly, common complications after ICL surgery, including residual viscoelastic, steroid response, and excessive vault of the ICL, are detailed, emphasizing their potential impact on intraocular pressure. Regarding residual viscoelastic, we delve into its direct relationship with postoperative elevated IOP and possible preventive measures. For steroid response, we stress the importance of timely adjustment of steroid therapy and monitoring intraocular pressure. Additionally, excessive vault of the ICL is considered a significant potential issue, and we elaborate on its mechanism and possible management methods. In further discussion, we focus on relatively rare complications such as Toxic Anterior Segment Syndrome (TASS), Urrets-Zavalia Syndrome (UZS), Pigment Dispersion Syndrome (PDS), and malignant glaucoma. For these relatively rare complications, this review thoroughly explores their potential mechanisms, emphasizes the importance of prevention, and provides guidance for early diagnosis and treatment. This is a comprehensible review that aims to offer eye care professionals a comprehensive understanding and effective management guidance for complications of elevated IOP after ICL surgery, ultimately providing optimal care for patients\u2019 visual health.<\/jats:p>","DOI":"10.3389\/fmed.2024.1351272","type":"journal-article","created":{"date-parts":[[2024,2,7]],"date-time":"2024-02-07T00:29:38Z","timestamp":1707265778000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":28,"title":["Causes and management strategies for elevated intraocular pressure after implantable collamer lens implantation"],"prefix":"10.3389","volume":"11","author":[{"given":"Di","family":"Gong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simin","family":"Deng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuanrong","family":"Dang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zonghui","family":"Yan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiantao","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2024,2,7]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.survophthal.2023.09.005","article-title":"Refractive surgical correction and treatment of keratoconus","volume":"69","author":"D\u2019Oria","year":"2024","journal-title":"Surv Ophthalmol"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"e288","DOI":"10.1111\/aos.14599","article-title":"Posterior-chamber phakic implantable collamer lenses with a central port: a review","volume":"99","author":"Mont\u00e9s-Mic\u00f3","year":"2021","journal-title":"Acta Ophthalmol"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1016\/j.ajo.2013.05.018","article-title":"Intraocular pressure after implantation of the Visian implantable Collamer Lens with CentraFLOW without iridotomy","volume":"156","author":"Higueras-Esteban","year":"2013","journal-title":"Am J Ophthalmol"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1007\/s00417-007-0759-2","article-title":"Crystalline lens changes in porcine eyes with implanted phakic IOL (ICL) with a central hole","volume":"246","author":"Shiratani","year":"2008","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"4625","DOI":"10.1167\/iovs.16-19900","article-title":"Computational study of aqueous humor dynamics assessing the vault and the pupil diameter in two posterior-chamber Phakic lenses","volume":"57","author":"Fern\u00e1ndez-Vigo","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"540","DOI":"10.1080\/02713683.2021.2012202","article-title":"Long-term comparison of vault and complications of implantable Collamer Lens with and without a central hole for high myopia correction: 5 years","volume":"47","author":"Chen","year":"2022","journal-title":"Curr Eye Res"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"969","DOI":"10.2147\/OPTH.S379856","article-title":"Intraocular implantable Collamer Lens with a central hole implantation: safety, efficacy, and patient outcomes","volume":"17","author":"Wannapanich","year":"2023","journal-title":"Clin Ophthalmol"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"3625","DOI":"10.1007\/s10792-022-02355-w","article-title":"Analysis of perioperative problems related to intraocular implantable Collamer Lens (ICL) implantation","volume":"42","author":"Zhang","year":"2022","journal-title":"Int Ophthalmol"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1007\/s10792-015-0112-4","article-title":"Causes of elevated intraocular pressure following implantation of phakic intraocular lenses for myopia","volume":"36","author":"Almalki","year":"2016","journal-title":"Int Ophthalmol"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"2020","DOI":"10.1093\/ajhp\/zxab228","article-title":"A primer on ocular viscosurgical devices","volume":"78","author":"Gerberich","year":"2021","journal-title":"Am J Health Syst Pharm"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"207","DOI":"10.2147\/OPTH.S89487","article-title":"Comparison of surgical time and IOP spikes with two ophthalmic viscosurgical devices following Visian STAAR (ICL, V4c model) insertion in the immediate postoperative period","volume":"10","author":"Ganesh","year":"2016","journal-title":"Clin Ophthalmol"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1186\/s12886-020-1320-x","article-title":"One-year natural course of corneal densitometry in high myopic patients after implantation of an implantable collamer lens (model V4c)","volume":"20","author":"Chen","year":"2020","journal-title":"BMC Ophthalmol"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"1359","DOI":"10.18240\/ijo.2021.09.10","article-title":"One-step viscoelastic agent technique for ICL V4c implantation for myopia","volume":"14","author":"Miao","year":"2021","journal-title":"Int J Ophthalmol"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"42","DOI":"10.3928\/1081597X-20191119-02","article-title":"Safety of the minimum ophthalmic Viscosurgical device technique in Phakic implantable Collamer Lens implantation","volume":"36","author":"Chen","year":"2020","journal-title":"J Refract Surg"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1186\/s40662-020-00185-4","article-title":"A novel ophthalmic viscosurgical device-free phakic intraocular lens implantation makes myopic surgery safer","volume":"7","author":"Pan","year":"2020","journal-title":"Eye Vis"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1097\/j.jcrs.0000000000000417","article-title":"Comparison of clinical outcomes of implantable collamer lens implantation with and without use of an ophthalmic viscosurgical device","volume":"47","author":"Kim","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"764653","DOI":"10.3389\/fmed.2021.764653","article-title":"Safety of EVO ICL implantation with an ophthalmic Viscosurgical device-free technique in the early 24 h after surgery","volume":"8","author":"Zhang","year":"2021","journal-title":"Front Med"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1159\/000328630","article-title":"Steroid-induced iatrogenic glaucoma","volume":"47","author":"Razeghinejad","year":"2012","journal-title":"Ophthalmic Res"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1016\/j.survophthal.2020.01.002","article-title":"Steroid-induced glaucoma: epidemiology, pathophysiology, and clinical management","volume":"65","author":"Roberti","year":"2020","journal-title":"Surv Ophthalmol"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.preteyeres.2016.09.003","article-title":"Steroid-induced ocular hypertension\/glaucoma: focus on pharmacogenomics and implications for precision medicine","volume":"56","author":"Fini","year":"2017","journal-title":"Prog Retin Eye Res"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"643","DOI":"10.53738\/REVMED.2023.19.820.643","article-title":"Corticosteroids and glaucoma","volume":"19","author":"Abouzeid","year":"2023","journal-title":"Rev Med Suisse"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.jcrs.2011.07.035","article-title":"Central vault after phakic intraocular lens implantation: correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient age","volume":"38","author":"Alfonso","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1016\/j.jcjo.2017.11.018","article-title":"Incidence of implantable Collamer lens-induced cataract","volume":"53","author":"Gimbel","year":"2018","journal-title":"Can J Ophthalmol"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"1555","DOI":"10.1016\/j.jcrs.2019.06.015","article-title":"Ten-year clinical outcomes after implantation of a posterior chamber phakic intraocular lens for myopia","volume":"45","author":"Choi","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"ref25","doi-asserted-by":"publisher","first-page":"765","DOI":"10.3928\/1081597X-20110617-01","article-title":"Implantable collamer posterior chamber intraocular lenses: a review of potential complications","volume":"27","author":"Fernandes","year":"2011","journal-title":"J Refract Surg"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"2427","DOI":"10.2147\/OPTH.S188785","article-title":"The implantable Collamer Lens with a central port: review of the literature","volume":"12","author":"Packer","year":"2018","journal-title":"Clin Ophthalmol"},{"key":"ref27","doi-asserted-by":"publisher","first-page":"900","DOI":"10.1097\/j.jcrs.0000000000000886","article-title":"Safety of intraocular pressure measurement using air-puff tonometer after implantable collamer lens implantation","volume":"48","author":"Shen","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"ref28","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1097\/j.jcrs.0000000000000146","article-title":"Determining vault size in implantable collamer lenses: preoperative anatomy and lens parameters","volume":"46","author":"Tranc\u00f3n","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"ref29","doi-asserted-by":"publisher","first-page":"1099","DOI":"10.1016\/j.jcrs.2019.02.020","article-title":"Predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography","volume":"45","author":"Igarashi","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"ref30","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1186\/s12886-016-0336-8","article-title":"Comparison of early changes in and factors affecting vault following posterior chamber phakic implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)","volume":"16","author":"Chen","year":"2016","journal-title":"BMC Ophthalmol"},{"key":"ref31","doi-asserted-by":"publisher","first-page":"354","DOI":"10.3928\/1081597X-20230207-02","article-title":"The non-uniform distribution of horizontal and vertical crystalline Lens rise using optical coherence tomography","volume":"39","author":"Fan","year":"2023","journal-title":"J Refract Surg"},{"key":"ref32","first-page":"466","article-title":"Transient reduction in the retinal microvascular network following implantation surgery of implantable collamer lens: an OCT angiography study","volume":"27","author":"Hu","year":"2021","journal-title":"Mol Vis"},{"key":"ref33","doi-asserted-by":"publisher","first-page":"4861","DOI":"10.1007\/s10792-023-02888-8","article-title":"Assessing the efficacy of four methods established by four parameters in ICL size selection and relevant influencing factors: a prospective cohort study","volume":"43","author":"Tang","year":"2023","journal-title":"Int Ophthalmol"},{"key":"ref34","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1097\/j.jcrs.0000000000000915","article-title":"Intraoperative adjustment of implantable collamer lens vault by lens rotation aided by intraoperative OCT","volume":"48","author":"Zaldivar","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"ref35","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1186\/s12886-023-02942-0","article-title":"Evaluation of biometric indicators of anterior segment parameters after ICL implantation by swept-source optical coherence tomography","volume":"23","author":"Tang","year":"2023","journal-title":"BMC Ophthalmol"},{"key":"ref36","doi-asserted-by":"publisher","first-page":"2689","DOI":"10.1007\/s10792-017-0757-2","article-title":"Vertical implantable collamer lens (ICL) rotation for the management of high vault due to lens oversizing","volume":"38","author":"Matarazzo","year":"2018","journal-title":"Int Ophthalmol"},{"key":"ref37","doi-asserted-by":"publisher","first-page":"1104047","DOI":"10.3389\/fmed.2023.1104047","article-title":"The long-term observation of the rotation of implantable collamer lens as the management of high postoperative vault","volume":"10","author":"Jiang","year":"2023","journal-title":"Front Med"},{"key":"ref38","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.jfo.2010.08.006","article-title":"Toxic anterior segment syndrome","volume":"34","author":"Cornut","year":"2011","journal-title":"J Fr Ophtalmol"},{"key":"ref39","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.jfo.2021.12.009","article-title":"Toxic anterior segment syndrome following EyePCL implantation in a hyperopic patient","volume":"45","author":"Pintiliuc","year":"2022","journal-title":"J Fr Ophtalmol"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.1136\/bcr-2018-225806","article-title":"Toxic anterior segment syndrome following phakic posterior chamber IOL: a rarity","volume":"11","author":"Singh","year":"2018","journal-title":"BMJ Case Rep"},{"key":"ref41","doi-asserted-by":"publisher","first-page":"856","DOI":"10.3928\/1081597X-20201015-01","article-title":"Occlusion of AquaPORT flow in a case of toxic anterior segment syndrome following implantable Collamer Lens surgery causing severe pupillary block","volume":"36","author":"Mimouni","year":"2020","journal-title":"J Refract Surg"},{"key":"ref42","doi-asserted-by":"publisher","first-page":"202","DOI":"10.5935\/0004-2749.20160059","article-title":"Update and review of Urrets-Zavalia syndrome","volume":"79","author":"Magalh\u00e3es","year":"2016","journal-title":"Arq Bras Oftalmol"},{"key":"ref43","doi-asserted-by":"publisher","first-page":"3166","DOI":"10.4103\/ijo.IJO_896_22","article-title":"Innovation Urrets-Zavalia syndrome","volume":"70","author":"Narang","year":"2022","journal-title":"Indian J Ophthalmol"},{"key":"ref44","doi-asserted-by":"publisher","first-page":"1","DOI":"10.5693\/djo.02.2014.09.002","article-title":"Urrets-Zavalia syndrome after implantable Collamer lens placement","volume":"21","author":"Al Habash","year":"2015","journal-title":"Digit J Ophthalmol"},{"key":"ref45","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1186\/s13256-021-03063-2","article-title":"Unilateral Urrets-Zavalia syndrome after implantable Collamer Lens implantation: a case report and review of the literature","volume":"15","author":"Niruthisard","year":"2021","journal-title":"J Med Case Rep"},{"key":"ref46","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1055\/a-1610-9239","article-title":"Urrets-Zavalia syndrome after implantation of a Phakic intraocular Lens","volume":"240","author":"Fraenkel","year":"2023","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"ref47","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.ajoc.2018.01.046","article-title":"Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant","volume":"10","author":"Ye","year":"2018","journal-title":"Am J Ophthalmol Case Rep"},{"key":"ref48","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1016\/S0002-9394(00)00606-1","article-title":"Pigmentary dispersion syndrome induced by a posterior chamber phakic refractive lens","volume":"131","author":"Brandt","year":"2001","journal-title":"Am J Ophthalmol"},{"key":"ref49","doi-asserted-by":"publisher","first-page":"743","DOI":"10.1016\/j.survophthal.2021.01.002","article-title":"Pigment dispersion syndrome and its implications for glaucoma","volume":"66","author":"Bustamante-Arias","year":"2021","journal-title":"Surv Ophthalmol"},{"key":"ref50","doi-asserted-by":"publisher","first-page":"1452","DOI":"10.1016\/j.jcrs.2006.04.023","article-title":"Iris and trabecular meshwork pigment changes after posterior chamber phakic intraocular lens implantation","volume":"32","author":"Chun","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"ref51","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1186\/s40662-023-00335-4","article-title":"Primary observations of EVO ICL implantation for high myopia with concave iris","volume":"10","author":"Zhang","year":"2023","journal-title":"Eye Vis"},{"key":"ref52","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1097\/ICU.0000000000000352","article-title":"Update on pigment dispersion syndrome and pigmentary glaucoma","volume":"28","author":"Okafor","year":"2017","journal-title":"Curr Opin Ophthalmol"},{"key":"ref53","doi-asserted-by":"publisher","first-page":"2217","DOI":"10.1016\/S0886-3350(02)01213-0","article-title":"Malignant glaucoma induced by a phakic posterior chamber intraocular lens for myopia","volume":"28","author":"Kodjikian","year":"2002","journal-title":"J Cataract Refract Surg"},{"key":"ref54","doi-asserted-by":"publisher","first-page":"e0165469","DOI":"10.1371\/journal.pone.0165469","article-title":"Etiology and Management of Raised Intraocular Pressure following posterior chamber Phakic intraocular Lens implantation in myopic eyes","volume":"11","author":"Senthil","year":"2016","journal-title":"PLoS One"},{"key":"ref55","doi-asserted-by":"publisher","first-page":"181","DOI":"10.4103\/meajo.MEAJO_197_18","article-title":"Unilateral malignant Glaucoma Postbilateral implantable Collamer Lens: effect of Miotics","volume":"26","author":"Chanbour","year":"2019","journal-title":"Middle East Afr J Ophthalmol"},{"key":"ref56","doi-asserted-by":"publisher","first-page":"1206","DOI":"10.4103\/ijo.IJO_134_19","article-title":"Commentary: malignant Glaucoma - have we finally found an answer?","volume":"67","author":"Kaushik","year":"2019","journal-title":"Indian J Ophthalmol"},{"key":"ref57","doi-asserted-by":"publisher","first-page":"1155","DOI":"10.1007\/s00347-022-01718-z","article-title":"Therapy of malignant glaucoma","volume":"119","author":"Unterlauft","year":"2022","journal-title":"Fortschr Ophthalmol"}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2024.1351272\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,7]],"date-time":"2024-02-07T00:29:40Z","timestamp":1707265780000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2024.1351272\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,7]]},"references-count":57,"alternative-id":["10.3389\/fmed.2024.1351272"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2024.1351272","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,7]]},"article-number":"1351272"}}