{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T16:05:26Z","timestamp":1753891526744,"version":"3.41.2"},"reference-count":24,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,10,15]],"date-time":"2024-10-15T00:00:00Z","timestamp":1728950400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>To compare the accuracy of intraoperative wavefront aberrometry using the ORA VLynk system with different biometry-based formulas in short and long eyes after cataract surgery.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This prospective study considered 48 eyes with axial lengths of &amp;lt;22.1\u2009mm and 48 eyes with axial lengths of &amp;gt;25.0\u2009mm. All eyes were implanted with the monofocal AcrySof IQ IOL, the power being determined using the ORA VLynk. The postoperative spherical equivalent (SE) at 3\u2009months was compared to that predicted preoperatively using the SRK\/T, Hoffer Q, Haigis, Holladay 2, Barrett Universal II, and Barrett True K formulas and intraoperatively using the ORA VLynk. Mean numerical and absolute errors and the percentage of eyes within \u00b10.50 D\/1.00 D of their target were obtained.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>For long eyes, the mean absolute error values were 0.35, 0.52, 0.34, 0.30, 0.29, 0.27, and 0.24D for SRK\/T, Hoffer Q, Haigis, Holladay 2, Barrett Universal II, Barrett True K, and ORA VLynk, respectively (<jats:italic>p<\/jats:italic>\u2009&amp;lt;\u20090.001). These values were 0.55, 0.45, 0.49, 0.40, 0.44, 0.44 and 0.50 D for short eyes, respectively (<jats:italic>p<\/jats:italic>\u2009&amp;lt;\u20090.001). The proportions of long eyes within \u00b10.50 D of the target were 77.08, 50, 75, 85.42, 83.33, 79.17, and 87.50%, respectively; and 50, 66.67, 60.42, 66.67, 60.42, 60.42, and 58.33%, respectively, for short eyes.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The ORA VLynk performs better than all biometry-based formulas in long eyes and, in short eyes, it is as effective as SRK\/T, Haigis, Barrett Universal II, and Barrett true K, with the Hoffer Q and Holladay 2 being the most accurate; however, the differences between the calculation methods were small.<\/jats:p><\/jats:sec><jats:sec><jats:title>Clinical trial registration<\/jats:title><jats:p>Identifier DRKS000028106.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fmed.2024.1466885","type":"journal-article","created":{"date-parts":[[2024,10,15]],"date-time":"2024-10-15T04:37:07Z","timestamp":1728967027000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Accuracy of intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in short and long eyes"],"prefix":"10.3389","volume":"11","author":[{"given":"Pedro","family":"Ta\u00f1\u00e1-Rivero","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paz","family":"Orts-Vila","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pedro","family":"Ta\u00f1\u00e1-Sanz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Santiago","family":"Ta\u00f1\u00e1-Sanz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ram\u00f3n","family":"Ruiz-Mesa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"Mont\u00e9s-Mic\u00f3","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1965","published-online":{"date-parts":[[2024,10,15]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"484","DOI":"10.3928\/1081597X-20130617-07","article-title":"Comparison of IOL power calculation methods and intraoperative wavefront aberrometer in eyes after refractive surgery","volume":"29","author":"Canto","year":"2013","journal-title":"J Refract Surg"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.ophtha.2013.08.041","article-title":"Intraoperative refractive biometry for predicting intraocular lens power calculation after prior myopic refractive surgery","volume":"121","author":"Ianchulev","year":"2014","journal-title":"Ophthalmology"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"1096","DOI":"10.1016\/j.ophtha.2015.01.027","article-title":"Comparison of intraoperative Aberrometry, OCT-based IOL formula, Haigis-L, and Masket formulae for IOL power calculation after laser vision correction","volume":"122","author":"Fram","year":"2015","journal-title":"Ophthalmology"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"69","DOI":"10.3928\/1081597X-20151210-02","article-title":"Intraoperative Wavefront Aberrometry for Toric intraocular Lens placement in eyes with a history of refractive surgery","volume":"32","author":"Yesilirmak","year":"2016","journal-title":"J Refract Surg"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1111\/ceo.13153","article-title":"Clinical outcomes with distance-dominant multifocal and monofocal intraocular lenses in post-LASIK cataract surgery planned using an intraoperative aberrometer","volume":"46","author":"Fisher","year":"2018","journal-title":"Clin Experiment Ophthalmol"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.ajoc.2018.02.026","article-title":"Optiwave refractive analysis may not work well in patients with previous history of radial keratotomy","volume":"10","author":"Zhang","year":"2018","journal-title":"Am J Ophthalmol Case Rep"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"656","DOI":"10.3928\/1081597X-20190913-01","article-title":"Intraoperative Aberrometry versus preoperative biometry for IOL power selection after radial keratotomy: a prospective study","volume":"35","author":"Curado","year":"2019","journal-title":"J Refract Surg"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"481","DOI":"10.3928\/1081597X-20200519-04","article-title":"Network meta-analysis of no-history methods to calculate intraocular lens power in eyes with previous myopic laser refractive surgery","volume":"36","author":"Wen","year":"2020","journal-title":"J Refract Surg"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1097\/ICU.0000000000000915","article-title":"Intraoperative aberrometry: an update on applications and outcomes","volume":"34","author":"Kaufman","year":"2023","journal-title":"Curr Opin Ophthalmol"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"1485","DOI":"10.2147\/OPTH.S191887","article-title":"Retrospective analysis of an intraoperative aberrometry database: a study investigating absolute prediction in eyes implanted with low cylinder power toric intraocular lenses","volume":"13","author":"Cionni","year":"2019","journal-title":"Clin Ophthalmol"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"229","DOI":"10.3928\/1081597X-20230127-01","article-title":"Visual and refractive outcomes of a trifocal toric intraocular lens implanted in eyes with high corneal astigmatism","volume":"39","author":"Ruiz-Mesa","year":"2023","journal-title":"J Refract Surg"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1016\/j.jcrs.2017.01.014","article-title":"Intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in axial myopia","volume":"43","author":"Hill","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1016\/j.jcrs.2018.12.016","article-title":"Intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in short eyes","volume":"45","author":"Sudhakar","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"609","DOI":"10.3928\/1081597X-20210609-03","article-title":"Refractive outcomes using intraoperative aberrometry for highly myopic, highly hyperopic, and post-refractive eyes","volume":"37","author":"Soifer","year":"2021","journal-title":"J Refract Surg"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"1165","DOI":"10.2147\/OPTH.S363228","article-title":"Comparison of the accuracy of intraoperative aberrometry in intraocular lens implantation between myopic eyes with emmetropia and myopia targets","volume":"16","author":"Sakai","year":"2022","journal-title":"Clin Ophthalmol"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"4295","DOI":"10.4103\/ijo.IJO_1307_22","article-title":"Intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in patients with axial hyperopia","volume":"70","author":"Bansal","year":"2022","journal-title":"Indian J Ophthalmol"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1007\/s10792-012-9690-6","article-title":"Evaluation of refractive error after cataract surgery in highly myopic eyes","volume":"33","author":"Yokoi","year":"2013","journal-title":"Int Ophthalmol"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.jcrs.2010.07.032","article-title":"Formula choice: Hoffer Q, Holladay 1, or SRK\/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry","volume":"37","author":"Aristodemou","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"151","DOI":"10.3341\/kjo.2011.25.3.151","article-title":"Intraocular lens power calculation using IOLMaster and various formulas in short eyes","volume":"25","author":"Roh","year":"2011","journal-title":"Korean J Ophthalmol"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1016\/j.ajo.2014.11.036","article-title":"Accuracy of the refractive prediction determined by multiple currently available intraocular lens power calculation formulas in small eyes","volume":"159","author":"Carifi","year":"2015","journal-title":"Am J Ophthalmol"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"1490","DOI":"10.1016\/j.jcrs.2016.07.021","article-title":"Intraocular lens power formula accuracy: comparison of 7 formulas","volume":"42","author":"Kane","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"892","DOI":"10.1016\/j.jcrs.2017.07.004","article-title":"Intraocular lens power calculations in short eyes using 7 formulas","volume":"43","author":"G\u00f6kce","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1111\/ceo.13034","article-title":"Contributors to the vision eye institute IOL outcomes registry. Comparison of Hill-radial basis function, Barrett universal and current third generation formulas for the calculation of intraocular lens power during cataract surgery","volume":"46","author":"Roberts","year":"2018","journal-title":"Clin Experiment Ophthalmol"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1097\/j.jcrs.0000000000000173","article-title":"Intraoperative aberrometry vs modern preoperative formulas in predicting intraocular lens power","volume":"46","author":"Raufi","year":"2020","journal-title":"J Cataract Refract Surg"}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2024.1466885\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,15]],"date-time":"2024-10-15T04:37:09Z","timestamp":1728967029000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2024.1466885\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,15]]},"references-count":24,"alternative-id":["10.3389\/fmed.2024.1466885"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2024.1466885","relation":{},"ISSN":["2296-858X"],"issn-type":[{"type":"electronic","value":"2296-858X"}],"subject":[],"published":{"date-parts":[[2024,10,15]]},"article-number":"1466885"}}