{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T05:32:52Z","timestamp":1782970372920,"version":"3.54.5"},"reference-count":21,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2024,11,5]],"date-time":"2024-11-05T00:00:00Z","timestamp":1730764800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>This study aimed to compare the consistency of pupil offset measurements obtained using the Pentacam, Keratron Scout, and Sirius devices.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This retrospective cross-sectional study included 146 young myopic individuals (292 eyes) scheduled for refractive surgery at Dalian Third People\u2019s Hospital between January 2023 and December 2023. Three devices were utilized to measure the chord mu of the pupil deviation along with the Cartesian distances of the X and Y coordinates (Px, Py) associated with the pupil offset. Repeated-measures analysis of variance was used to compare differences in pupil offset acquisition across various devices. Additionally, the intraclass correlation coefficient (ICC) and Bland\u2013Altman plot were utilized to assess the consistency among the three devices.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Chord mu, measured using the Pentacam, Keratron Scout, and Sirius devices, were 0.18 \u00b1 0.10, 0.21 \u00b1 0.11, and 0.18 \u00b1 0.11, respectively. The Px values were 0.00 \u00b1 0.14, -0.02 \u00b1 0.16, and -0.01 \u00b1 0.13, respectively, while the Py values were 0.09 \u00b1 0.13, 0.10 \u00b1 0.15, and 0.10 \u00b1 0.13. The ICCs for the three device measurements, chord mu, Px, and Py, were 0.817, 0.900, and 0.855, respectively. When comparing the three devices, the 95% limits of agreement (LoA) for mu and Px measured using the Sirius and Keratron Scout were the narrowest, ranging from \u22120.15 to 0.08 and \u22120.11 to 0.13, respectively. Additionally, the 95% LoA for Py measured using the Sirius and Pentacam was the narrowest, ranging from \u22120.13 to 0.15. The pupil centers in both eyes were predominantly located above the apex of the cornea.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Sirius, Keratron Scout, and Pentacam have good consistency in pupil shift measurement in young myopic patients, and the three devices can be used as references in clinical practice.<\/jats:p><\/jats:sec>","DOI":"10.3389\/fmed.2024.1490674","type":"journal-article","created":{"date-parts":[[2024,11,5]],"date-time":"2024-11-05T04:46:01Z","timestamp":1730781961000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":3,"title":["Comparison of Scheimpflug tomography, Placido disc, and combined Placido Scheimpflug in the measurement of pupil offset in myopic population"],"prefix":"10.3389","volume":"11","author":[{"given":"Jiliang","family":"Ning","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lijun","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2024,11,5]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1016\/j.jcrs.2019.03.019","article-title":"Decentration measurements using Placido corneal tangential curvature topography and Scheimpflug tomography pachymetry difference maps after small-incision lenticule extraction","volume":"45","author":"Chung","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s40662-015-0014-6","article-title":"Centration axis in refractive surgery","volume":"2","author":"Mosquera","year":"2015","journal-title":"Eye Vis"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"2316","DOI":"10.1167\/iovs.17-23451","article-title":"Relationship between decentration and induced corneal higher-order aberrations following small-incision lenticule extraction procedure","volume":"59","author":"Lee","year":"2018","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"731","DOI":"10.3928\/1081597X-20091209-01","article-title":"Effects of decentration of photorefractive keratectomy on the induction of higher order wavefront aberrations","volume":"26","author":"Lee","year":"2010","journal-title":"J Refract Surg"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1186\/s12886-023-02960-y","article-title":"Effect of preoperative pupil offset on corneal higher-order aberrations after femtosecond laser-assisted in situ keratomileusis","volume":"23","author":"Liu","year":"2023","journal-title":"BMC Ophthalmol"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"3555","DOI":"10.1007\/s10792-020-01506-1","article-title":"Clinical outcomes of corneal refractive surgery comparing centration on the corneal vertex with the pupil center: a meta-analysis","volume":"40","author":"Zhang","year":"2020","journal-title":"Int Ophthalmol"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"1809","DOI":"10.1016\/j.jcrs.2011.04.033","article-title":"Repeatability of automatic measurements by a new Scheimpflug camera combined with Placido topography","volume":"37","author":"Savini","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1016\/j.jcrs.2015.11.046","article-title":"Keratometry versus total corneal refractive power: analysis of measurement repeatability with 5 different devices in normal eyes with low astigmatism","volume":"42","author":"Fityo","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J Chiropr Med"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1097\/ICU.0b013e3283543c41","article-title":"Measurement of angle kappa and centration in refractive surgery","volume":"23","author":"Park","year":"2012","journal-title":"Curr Opin Ophthalmol"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1097\/ICO.0000000000000383","article-title":"Decentration of optical zone center and its impact on visual outcomes following SMILE","volume":"34","author":"Liu","year":"2015","journal-title":"Cornea"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"518","DOI":"10.3928\/1081597X-20130719-08","article-title":"Coaxially sighted corneal light reflex versus entrance pupil center centration of moderate to high hyperopic corneal ablations in eyes with small and large angle kappa","volume":"29","author":"Reinstein","year":"2013","journal-title":"J Refract Surg"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1080\/08164622.2023.2203316","article-title":"A comparative study of pupil offset measurement using Pentacam and Keratron scout in myopic young adults","volume":"107","author":"Sun","year":"2024","journal-title":"Clin Exp Optom"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1167\/tvst.11.6.13","article-title":"Characteristics of pupil offset in young asian adults with mild-moderate and high myopia","volume":"11","author":"Sun","year":"2022","journal-title":"Transl Vis Sci Technol"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"49","DOI":"10.3928\/1081597X-20201109-01","article-title":"Distribution of pupil offset and angle kappa in a refractive surgery preoperative population of 750 myopic, emmetropic, and hyperopic eyes","volume":"37","author":"Reinstein","year":"2021","journal-title":"J Refract Surg"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/S0886-3350(02)01638-3","article-title":"Maximum permissible lateral decentration in aberration-sensing and wavefront-guided corneal ablation","volume":"29","author":"Bueeler","year":"2003","journal-title":"J Cataract Refract Surg"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"2583","DOI":"10.2147\/OPTH.S251998","article-title":"Scheimpflug vs scanning-slit corneal tomography: comparison of corneal and anterior chamber tomography indices for repeatability and agreement in healthy eyes","volume":"14","author":"Kanellopoulos","year":"2020","journal-title":"Clin Ophthalmol"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1097\/j.jcrs.0000000000000734","article-title":"Agreement and repeatability of corneal tomography in healthy eyes using a new swept-source OCT, a rotating Scheimpflug camera, and a dual Scheimpflug-Placido system","volume":"48","author":"Herber","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1186\/s12886-021-02116-w","article-title":"Comparison of preoperative angle kappa measurements in the eyes of cataract patients obtained from Pentacam Scheimpflug system, optical low-coherence reflectometry, and ray-tracing aberrometry","volume":"22","author":"Qin","year":"2022","journal-title":"BMC Ophthalmol"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1186\/s12886-019-1153-7","article-title":"Decentration following femtosecond laser small incision lenticule extraction (SMILE) in eyes with high astigmatism and its impact on visual quality","volume":"19","author":"Huang","year":"2019","journal-title":"BMC Ophthalmol"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"239","DOI":"10.3928\/1081597X-20200310-01","article-title":"Comparison of the distribution of lenticule decentration following SMILE by pupil center or tear film mark centration","volume":"36","author":"Liu","year":"2020","journal-title":"J Refract Surg"}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2024.1490674\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,5]],"date-time":"2024-11-05T04:46:05Z","timestamp":1730781965000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2024.1490674\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,5]]},"references-count":21,"alternative-id":["10.3389\/fmed.2024.1490674"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2024.1490674","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,5]]},"article-number":"1490674"}}