{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T23:28:25Z","timestamp":1783726105884,"version":"3.55.0"},"reference-count":73,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,3,7]],"date-time":"2025-03-07T00:00:00Z","timestamp":1741305600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:p>With the wide application of implantable collamer lens (ICL) surgery for myopia correction, the range of refractive correction has expanded (up to \u221218.00 D for myopia), and the safety, effectiveness, predictability and stability of ICLs have been well documented. However, achieving good visual quality after ICL implantation has also become very important. This article systematically reviews objective and subjective visual quality after ICL surgery. First, parameters used to assess objective visual quality after ICL surgery are introduced, including higher-order aberrations, the modulation transfer function (MTF) cutoff (cycles per degree [cpd]), the Strehl 2D ratio (SR), and the objective scatter index (OSI). Notably, various post-operative objective visual quality measurements have been improving over time. However, halos and glare caused by ICL implantation are notable postoperative complications. In further discussions, we also focus on factors that can affect visual quality, such as ICL position changes, pupil size, and the ICL optical zone. Furthermore, measures to improve postoperative visual quality, such as the selection of the surgical incision and mode, are provided. This review explores the potential mechanisms, emphasizes the importance of pre- and postoperative measures, and provides guidance for good postoperative visual quality. Additionally, this review aims to address the factors influencing visual quality and postoperative outcomes to optimize vision after ICL implantation.<\/jats:p>","DOI":"10.3389\/fmed.2025.1543864","type":"journal-article","created":{"date-parts":[[2025,3,7]],"date-time":"2025-03-07T06:51:23Z","timestamp":1741330283000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":10,"title":["Subjective and objective changes in visual quality after implantable collamer lens implantation for myopia"],"prefix":"10.3389","volume":"12","author":[{"given":"Li-li","family":"Nie","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiang","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying","family":"Pei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,3,7]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1016\/j.ophtha.2016.01.006","article-title":"Global Prevalence of Myopia and High Myopia and Temporal Trends from 2000 Through 2050","volume":"123","author":"Holden","year":"","journal-title":"Ophthalmology"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"2427","DOI":"10.2147\/OPTH.S188785","article-title":"The implantable Collamer Lens with a central port: Review of the literature","volume":"12","author":"Packer","year":"2018","journal-title":"Clin Ophthalmol (Auckland, NZ)"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1186\/s12886-023-03050-9","article-title":"Four-year visual outcomes and optical quality of SMILE and implantable collamer lens V4c (EVO-ICL) implantation for high myopia: a retrospective study","volume":"23","author":"Luo","year":"2023","journal-title":"BMC Ophthalmol"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"910","DOI":"10.1186\/s13063-022-06851-3","article-title":"Implantable collamer lens implantation (ICL) versus small incision lenticule extraction (SMILE) in low to moderate myopia: study protocol for a randomized, non-inferiority trial","volume":"23","author":"Li","year":"2022","journal-title":"Trials"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"160","DOI":"10.3892\/etm.2020.9289","article-title":"Implantable collamer lens with a central hole for residual refractive error correction after corneal refractive surgery","volume":"20","author":"Zhang","year":"2020","journal-title":"Exp Ther Med"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"737","DOI":"10.18240\/ijo.2021.05.15","article-title":"Optical and visual quality comparison of implantable collamer lens and femtosecond laser assisted laser in situ keratomileusis for high myopia correction","volume":"14","author":"Jiang","year":"2021","journal-title":"Int J Ophthalmol"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"e17677","DOI":"10.1097\/MD.0000000000017677","article-title":"Evaluation of visual quality after EVO-ICL implantation for hypermyopia an observational study","volume":"98","author":"Qin","year":"2019","journal-title":"Medicine"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"E943","DOI":"10.1111\/aos.14459","article-title":"Comparison of objective and subjective visual quality early after implantable collamer lens V4c (ICL V4c) and small incision lenticule extraction (SMILE) for high myopia correction","volume":"98","author":"Wei","year":"2020","journal-title":"Acta Ophthalmol"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"E662","DOI":"10.1111\/aos.14344","article-title":"One-year visual outcomes and optical quality of femtosecond laser small incision lenticule extraction and Visian implantable Collamer Lens (ICL V4c) implantation for high myopia","volume":"98","author":"Niu","year":"2020","journal-title":"Acta Ophthalmol"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"606","DOI":"10.1111\/aos.15638","article-title":"Clinical outcomes and higher order aberrations of wavefront-guided LASIK versus SMILE for correction of myopia: a systemic review and meta-analysis","volume":"101","author":"Tian","year":"2023","journal-title":"Acta Ophthalmol"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s40662-021-00251-5","article-title":"In vivo optical quality of posterior-chamber phakic implantable collamer lenses with a central port","volume":"8","author":"Montes-Mico","year":"2021","journal-title":"Eye Vision"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"1473","DOI":"10.1007\/s00417-022-05929-7","article-title":"Short-term clinic observation of misalignment and rotational stability after implantable collamer lens implantation","volume":"261","author":"Wei","year":"2023","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"1423","DOI":"10.1007\/s00417-012-2200-8","article-title":"Optical quality of the Visian implantable Collamer Lens for different refractive powers","volume":"251","author":"Perez-Vives","year":"2013","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.ajo.2013.01.030","article-title":"Optical quality comparison of conventional and hole-Visian implantable col lamer Lens at different degrees of decentering","volume":"156","author":"Perez-Vives","year":"2013","journal-title":"Am J Ophthalmol"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"1848","DOI":"10.18240\/ijo.2019.12.05","article-title":"The effects of implantable collamer lens implantation on higher order aberrations","volume":"12","author":"Kayhan","year":"2019","journal-title":"Int J Ophthalmol"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"S365","DOI":"10.1097\/ICL.0000000000000497","article-title":"Long-term clinical observation of posterior chamber Phakic intraocular Lens implantation in young population","volume":"44","author":"Chen","year":"2018","journal-title":"Eye Contact Lens"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"S270","DOI":"10.3928\/1081-597X-20030302-21","article-title":"Changes of higher order aberration with various pupil sizes in the myopic eye","volume":"19","author":"Wang","year":"2003","journal-title":"J Refract Surg"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"e35198","DOI":"10.1097\/MD.0000000000035198","article-title":"The influence of pupil diameter upon and subjective quality of vision following implantable collamer lens (ICL V4c) implantation an observational study","volume":"102","author":"Zhang","year":"2023","journal-title":"Medicine"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1111\/aos.14652","article-title":"Comparison of visual outcomes after non-toric and toric implantable collamer lens V4c for myopia and astigmatism","volume":"99","author":"Wei","year":"2021","journal-title":"Acta Ophthalmol"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1186\/s12886-021-02206-9","article-title":"Implantable collamer lens versus small incision lenticule extraction for high myopia correction: a systematic review and meta-analysis","volume":"21","author":"Cao","year":"2021","journal-title":"BMC Ophthalmol"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1136\/bjophthalmol-2011-300148","article-title":"Early clinical outcomes of implantation of posterior chamber phakic intraocular lens with a central hole (hole ICL) for moderate to high myopia","volume":"96","author":"Shimizu","year":"2012","journal-title":"Br J Ophthalmol"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1016\/j.ajo.2009.02.001","article-title":"Visual performance after implantable Collamer Lens implantation and Wavefront-guided laser in situ Keratomileusis for high myopia","volume":"148","author":"Igarashi","year":"2009","journal-title":"Am J Ophthalmol"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"780000","DOI":"10.3389\/fmed.2022.780000","article-title":"Two-year visual outcomes of evolution implantable Collamer Lens and small incision Lenticule extraction for the correction of low myopia","volume":"9","author":"Fu","year":"2022","journal-title":"Front Med"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"106","DOI":"10.3928\/1081597X-20111018-02","article-title":"Comparison of higher order aberrations after implantable Collamer Lens implantation and Wavefront-guided LASEK in high myopia","volume":"28","author":"Shin","year":"2012","journal-title":"J Refract Surg"},{"key":"ref25","doi-asserted-by":"publisher","first-page":"296-+","DOI":"10.3928\/1081597X-20140415-02","article-title":"Optical quality and intraocular scattering after femtosecond laser small incision Lenticule extraction","volume":"30","author":"Miao","year":"2014","journal-title":"J Refract Surg"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"1530","DOI":"10.1136\/bjophthalmol-2015-307135","article-title":"Objective and subjective visual quality after implantation of all optic zone diffractive multifocal intraocular lenses: a prospective, case-control observational study","volume":"100","author":"Chen","year":"2016","journal-title":"Br J Ophthalmol"},{"key":"ref27","doi-asserted-by":"publisher","first-page":"1381","DOI":"10.1136\/bjophthalmol-2015-306717","article-title":"Effect of femtosecond laser setting on visual performance after small-incision lenticule extraction for myopia","volume":"99","author":"Kamiya","year":"2015","journal-title":"Br J Ophthalmol"},{"key":"ref28","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1186\/s12886-019-1029-x","article-title":"Comparison of visual quality after EVO-ICL implantation and SMILE to select the appropriate surgical method for high myopia","volume":"19","author":"Qin","year":"2019","journal-title":"BMC Ophthalmol"},{"key":"ref29","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1016\/j.ajo.2021.02.005","article-title":"Effect of the EVO plus Visian Phakic implantable Collamer Lens on visual performance and quality of vision and life","volume":"226","author":"Martinez-Plaza","year":"2021","journal-title":"Am J Ophthalmol"},{"key":"ref30","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1186\/s12886-020-01340-0","article-title":"Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions","volume":"20","author":"He","year":"2020","journal-title":"BMC Ophthalmol"},{"key":"ref31","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1186\/s12886-022-02499-4","article-title":"Effects of tilt and decentration of Visian implantable Collamer Lens (ICL V4c) on visual quality: an observational study","volume":"22","author":"Niu","year":"2022","journal-title":"BMC Ophthalmol"},{"key":"ref32","doi-asserted-by":"publisher","first-page":"1157","DOI":"10.1097\/j.jcrs.0000000000001523","article-title":"Comparison of long-term visual quality after keratorefractive lenticule extraction and implantable collamer lens V4c for high myopia","volume":"50","author":"Zhan","year":"2024","journal-title":"J Cataract Refract Surg"},{"key":"ref33","doi-asserted-by":"publisher","first-page":"E170","DOI":"10.1111\/aos.13248","article-title":"Ring-shaped dysphotopsia associated with posterior chamber phakic implantable collamer lenses with a central hole","volume":"95","author":"Eom","year":"2017","journal-title":"Acta Ophthalmol"},{"key":"ref34","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2016\/5717932","article-title":"Effects of V4c-ICL implantation on myopic Patients' vision-related daily activities","volume":"2016","author":"Liu","year":"2016","journal-title":"J Ophthalmol"},{"key":"ref35","doi-asserted-by":"publisher","first-page":"280-+","DOI":"10.3928\/1081597X-20220405-01","article-title":"Determinants of subjective quality of vision after Phakic intraocular Lens implantation","volume":"38","author":"Mohr","year":"2022","journal-title":"J Refract Surg"},{"key":"ref36","doi-asserted-by":"publisher","first-page":"150-+","DOI":"10.3928\/1081597X-20200210-02","article-title":"SMILE versus implantable Collamer Lens implantation for high myopia: a matched comparative study","volume":"36","author":"Siedlecki","year":"2020","journal-title":"J Refract Surg"},{"key":"ref37","doi-asserted-by":"publisher","first-page":"2552","DOI":"10.1016\/j.jcrs.2015.05.034","article-title":"Ghost-image analysis in phakic intraocular lenses with central hole as a potential cause of dysphotopsia","volume":"41","author":"Eppig","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"ref38","doi-asserted-by":"publisher","first-page":"41","DOI":"10.3390\/vision4030041","article-title":"Effect of intraocular Lens tilt and Decentration on visual acuity, Dysphotopsia and Wavefront aberrations","volume":"4","author":"Ashena","year":"2020","journal-title":"Vision (Basel, Switzerland)"},{"key":"ref39","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1016\/j.jcrs.2018.10.045","article-title":"Effects of decentration and tilt at different orientations on the optical performance of a rotationally asymmetric multifocal intraocular lens","volume":"45","author":"Liu","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"ref40","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1038\/eye.2014.336","article-title":"Observing implantable collamer lens dislocation by panoramic ultrasound biomicroscopy","volume":"29","author":"Shi","year":"2015","journal-title":"Eye"},{"key":"ref41","doi-asserted-by":"publisher","first-page":"619","DOI":"10.18240\/ijo.2017.04.19","article-title":"Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens","volume":"10","author":"Park","year":"2017","journal-title":"Int J Ophthalmol"},{"key":"ref42","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2020\/7601524","article-title":"The influence of Decentration on higher-order aberrations in artisan Aphakic intraocular Lens implantation eyes","volume":"2020","author":"Miao","year":"2020","journal-title":"J Ophthalmol"},{"key":"ref43","doi-asserted-by":"publisher","first-page":"683","DOI":"10.3928\/1081-597X-20021101-04","article-title":"A new intraocular lens design to reduce spherical aberration of pseudophakic eyes","volume":"18","author":"Holladay","year":"2002","journal-title":"J Refract Surg"},{"key":"ref44","doi-asserted-by":"publisher","first-page":"403","DOI":"10.3928\/1081597X-20090422-01","article-title":"Postoperative astigmatism and Axis stability after implantation of the STAAR Toric implantable Collamer Lens","volume":"25","author":"Park","year":"2009","journal-title":"J Refract Surg"},{"key":"ref45","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1097\/01.APO.0000580144.22353.46","article-title":"Review on centration, astigmatic Axis alignment, pupil size and optical zone in SMILE","volume":"8","author":"Liu","year":"2019","journal-title":"Asia-Pacific J Ophthalmol"},{"key":"ref46","doi-asserted-by":"publisher","first-page":"734-+","DOI":"10.3928\/1081597X-20131021-02","article-title":"Pupil size and LASIK: a review","volume":"29","author":"Myung","year":"2013","journal-title":"J Refract Surg"},{"key":"ref47","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1097\/APO.0000000000000119","article-title":"Small pupil--big problem: a management algorithm","volume":"4","author":"Ratra","year":"2015","journal-title":"Asia-Pacific J Ophthalmol (Philadelphia, PA)"},{"key":"ref48","doi-asserted-by":"publisher","first-page":"1420","DOI":"10.1016\/j.jcrs.2017.08.013","article-title":"Pupil influence on the quality of vision in rotationally asymmetric multifocal IOLs with surface-embedded near segment","volume":"43","author":"Pazo","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"ref49","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1364\/JOSAA.34.000481","article-title":"Interaction of aberrations, diffraction, and quantal fluctuations determine the impact of pupil size on visual quality","volume":"34","author":"Xu","year":"2017","journal-title":"J Opt Soc Am Opt Image Sci Vis"},{"key":"ref50","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2019\/7174913","article-title":"Evaluation of disk halo size after implantation of a Collamer Lens with a central hole (ICL V4c)","volume":"2019","author":"Chen","year":"2019","journal-title":"J Ophthalmol"},{"key":"ref51","doi-asserted-by":"publisher","first-page":"532","DOI":"10.1016\/j.ajo.2013.11.006","article-title":"Eight-year follow-up of posterior chamber Phakic intraocular Lens implantation for moderate to high myopia","volume":"157","author":"Igarashi","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"ref52","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/S0161-6420(00)00403-6","article-title":"Safety of posterior chamber phakic intraocular lenses for the correction of high myopia -: anterior segment changes after posterior chamber phakic intraocular lens implantation","volume":"108","author":"Jim\u00e9nez-Alfaro","year":"2001","journal-title":"Ophthalmology"},{"key":"ref53","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1016\/j.jcrs.2014.07.039","article-title":"Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism","volume":"41","author":"Alfonso","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"ref54","doi-asserted-by":"publisher","first-page":"1461","DOI":"10.1136\/bjophthalmol-2016-309363","article-title":"Comparison of corneal endothelial cell density and morphology after posterior chamber phakic intraocular lens implantation with and without a central hole","volume":"101","author":"Goukon","year":"2017","journal-title":"Br J Ophthalmol"},{"key":"ref55","doi-asserted-by":"publisher","first-page":"1081","DOI":"10.1007\/s00417-010-1602-8","article-title":"Modulation transfer function of intraocular collamer lens with a central artificial hole","volume":"249","author":"Uozato","year":"2011","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"ref56","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1080\/17434440.2023.2174429","article-title":"EVO\/EVO plus Visian implantable Collamer lenses for the correction of myopia and myopia with astigmatism","volume":"20","author":"Martinez-Plaza","year":"2023","journal-title":"Expert Rev Med Devices"},{"key":"ref57","doi-asserted-by":"publisher","first-page":"2717","DOI":"10.2147\/OPTH.S271858","article-title":"Performance and safety of the extended depth of focus implantable Collamer\u00ae Lens (EDOF ICL) in Phakic subjects with presbyopia","volume":"14","author":"Packer","year":"2020","journal-title":"Clin Ophthalmol"},{"key":"ref58","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2018\/7623829","article-title":"Prospective randomized multicenter comparison of the clinical outcomes of V4c and V5 implantable Collamer lenses: a contralateral eye study","volume":"2018","author":"Kojima","year":"2018","journal-title":"J Ophthalmol"},{"key":"ref59","doi-asserted-by":"publisher","first-page":"2287","DOI":"10.1016\/j.ophtha.2010.03.054","article-title":"One-year follow-up of posterior chamber Toric Phakic intraocular Lens implantation for moderate to high myopic astigmatism","volume":"117","author":"Kamiya","year":"2010","journal-title":"Ophthalmology"},{"key":"ref60","doi-asserted-by":"publisher","first-page":"e56453","DOI":"10.1371\/journal.pone.0056453","article-title":"Three-year follow-up of posterior chamber Toric Phakic intraocular Lens implantation for moderate to high myopic astigmatism","volume":"8","author":"Kamiya","year":"2013","journal-title":"PLoS One"},{"key":"ref61","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2020\/3095302","article-title":"Clinical effect and rotational stability of TICL in the treatment of myopic astigmatism","volume":"2020","author":"Zhu","year":"2020","journal-title":"J Ophthalmol"},{"key":"ref62","doi-asserted-by":"publisher","first-page":"611","DOI":"10.3928\/1081597X-20090610-07","article-title":"Toric intraocular lenses-theory, matrix calculations, and clinical practice","volume":"25","author":"Langenbucher","year":"2009","journal-title":"J Refract Surg"},{"key":"ref63","doi-asserted-by":"publisher","first-page":"684","DOI":"10.1097\/ICO.0000000000001932","article-title":"The correlation between dry eyes, anxiety and depression: the sicca, anxiety and depression study","volume":"38","author":"Bitar","year":"2019","journal-title":"Cornea"},{"key":"ref64","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.jtos.2020.12.009","article-title":"The relationship between dry eye and sleep quality","volume":"20","author":"Magno","year":"2021","journal-title":"Ocul Surf"},{"key":"ref65","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1097\/ICO.0000000000002580","article-title":"Ocular discomfort and quality of life among patients in the dry eye assessment and management study","volume":"40","author":"Sayegh","year":"2021","journal-title":"Cornea"},{"key":"ref66","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1186\/s12886-024-03790-2","article-title":"SMILE and ICL implantation on the ocular surface and meibomian glands in patients with postoperative myopia","volume":"24","author":"Yao","year":"2024","journal-title":"BMC Ophthalmol"},{"key":"ref67","doi-asserted-by":"publisher","first-page":"656","DOI":"10.18240\/ijo.2018.04.20","article-title":"Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis","volume":"11","author":"Liu","year":"2018","journal-title":"Int J Ophthalmol"},{"key":"ref68","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1007\/s10792-020-01581-4","article-title":"Effect of brimonidine tartrate 0.2% ophthalmic solution on visual quality after implantable collamer lens implantation with a central hole","volume":"41","author":"Chen","year":"2020","journal-title":"Int Ophthalmol"},{"key":"ref69","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1016\/j.jcrs.2008.01.028","article-title":"Efficacy of brimonidine tartrate 0.2% ophthalmic solution in reducing halos after laser in situ keratomileusis","volume":"34","author":"Lee","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"ref70","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2021\/7363267","article-title":"Pure ICL implantation: a novel ophthalmic Viscosurgical device-free method","volume":"2021","author":"Qin","year":"2021","journal-title":"J Ophthalmol"},{"key":"ref71","doi-asserted-by":"publisher","first-page":"1291","DOI":"10.4103\/IJO.IJO_2859_23","article-title":"Clinical outcomes of a modified ophthalmic viscosurgical device-free implantable collamer lens implantation","volume":"72","author":"Wang","year":"2024","journal-title":"Indian J Ophthalmol"},{"key":"ref72","doi-asserted-by":"publisher","first-page":"1711","DOI":"10.1007\/s40123-023-00704-1","article-title":"Efficacy comparison between steep-Meridian incision and non-steep-Meridian incision in implantable Collamer Lens surgery with low-to-moderate astigmatism","volume":"12","author":"Liu","year":"2023","journal-title":"Ophthalmol Therapy"},{"key":"ref73","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1186\/s12886-017-0528-x","article-title":"Clinical efficacy of implantation of toric intraocular lenses with different incision positions: a comparative study of steep-axis incision and non-steep-axis incision","volume":"17","author":"He","year":"2017","journal-title":"BMC Ophthalmol"}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2025.1543864\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,7]],"date-time":"2025-03-07T06:51:27Z","timestamp":1741330287000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2025.1543864\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,7]]},"references-count":73,"alternative-id":["10.3389\/fmed.2025.1543864"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2025.1543864","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,7]]},"article-number":"1543864"}}