{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T14:24:32Z","timestamp":1790173472650,"version":"4.1.0"},"reference-count":27,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2025,7,7]],"date-time":"2025-07-07T00:00:00Z","timestamp":1751846400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:p>Intrauterine devices (IUDs) are widely used but carry rare risks of migration and subsequent complications, such as bowel obstruction. This case highlights the life-threatening potential of chronic IUD migration decades after insertion, emphasizing the need for heightened clinical vigilance and long-term surveillance. A 57-year-old female patient presented to the hospital with a 2-day history of abdominal pain, accompanied by the cessation of flatus and defecation. She had one pregnancy and one vaginal delivery 31 years ago, followed by the insertion of a ring-shaped IUD 1 year postpartum. However, she had not undergone any follow-up examinations since the IUD placement. Two years prior to admission, she attempted to have the IUD removed, but it was not detected within the uterine cavity. This resulted in the assumption that the device had been spontaneously expelled, and no further investigations were pursued at that time. CT imaging revealed small bowel obstruction and a ring-shaped intra-abdominal foreign body. Emergency laparotomy identified a migrated IUD strangulating 100 cm of necrotic ileum. Upon exploration of the uterus, a fibroid was identified on the posterior wall, but no acute perforations or other pathological changes were noted. Subsequently, the IUD was removed, and bowel resection with anastomosis was performed. Chronic IUD migration may evade detection for decades, culminating in catastrophic bowel obstruction. Clinicians must maintain high suspicion for IUD-related complications in patients with abdominal pain, even years after insertion. Prophylactic removal of misplaced devices and long-term imaging surveillance are critical to prevent morbidity. Early recognition of such rare but severe complications through comprehensive clinical assessment and imaging studies can significantly improve patient outcomes and reduce the risk of life - threatening bowel - related events.<\/jats:p>","DOI":"10.3389\/fmed.2025.1613116","type":"journal-article","created":{"date-parts":[[2025,7,7]],"date-time":"2025-07-07T04:10:40Z","timestamp":1751861440000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":4,"title":["Case Report: Strangulated intestinal obstruction due to chronic migration of an intrauterine device (IUD): a 30-year latent complication"],"prefix":"10.3389","volume":"12","author":[{"given":"Hong-Xia","family":"Song","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tian-Hao","family":"Xie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Fu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao-Shi","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zheng","family":"Niu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qian","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiu-Hua","family":"An","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2025,7,7]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","first-page":"41","DOI":"10.2147\/OAJC.S458156","article-title":"Migration of intra-uterine devices.","volume":"15","author":"Verstraeten","year":"2024","journal-title":"Open Access J Contracept."},{"key":"B2","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1016\/j.contraception.2015.01.007","article-title":"Risk of uterine perforation with levonorgestrel-releasing and copper intrauterine devices in the European Active Surveillance Study on Intrauterine Devices.","volume":"91","author":"Heinemann","year":"2015","journal-title":"Contraception."},{"key":"B3","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1093\/qjmed\/hcr260","article-title":"Obstruction of the small intestine by closed ring type intra-uterine devices.","volume":"23","author":"Haspels","year":"1971","journal-title":"Trop Geogr Med."},{"key":"B4","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1093\/qjmed\/hcr260","article-title":"Contraceptive ring-induced intestinal obstruction.","volume":"107","author":"Li","year":"2014","journal-title":"QJM."},{"key":"B5","first-page":"10125","article-title":"Small bowel obstruction caused by migrated intrauterine contraceptive device: A case report.","volume":"28","author":"Yang","year":"2017","journal-title":"Biom Res."},{"key":"B6","doi-asserted-by":"publisher","first-page":"E319","DOI":"10.1111\/ans.13173","article-title":"Intrauterine contraceptive device: Cause of small bowel obstruction and ischaemia.","volume":"87","author":"Xu","year":"2017","journal-title":"ANZ J Surg."},{"key":"B7","doi-asserted-by":"publisher","first-page":"1349","DOI":"10.1111\/ans.13910","article-title":"Ischaemic bowel due to migrated intra-uterine contraceptive device: A rare, delayed complication of intra-uterine contraceptive devices.","volume":"88","author":"Mellow","year":"2018","journal-title":"ANZ J Surg."},{"key":"B8","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1186\/s12905-025-03633-2","article-title":"Strangulated intestinal obstruction caused by ectopic intrauterine device: A case report.","volume":"25","author":"Zheng","year":"2025","journal-title":"BMC Womens Health."},{"key":"B9","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1002\/ijgo.12130","article-title":"Women\u2019s willingness and ability to feel the strings of their intrauterine device.","volume":"137","author":"Melo","year":"2017","journal-title":"Int J Gynaecol Obstet."},{"key":"B10","doi-asserted-by":"publisher","first-page":"883","DOI":"10.1097\/AOG.0000000000004967","article-title":"Long-acting reversible contraception.","volume":"140","author":"Baker","year":"2022","journal-title":"Obstet Gynecol."},{"key":"B11","doi-asserted-by":"publisher","first-page":"19","DOI":"10.2147\/OAJC.S85546","article-title":"Intrauterine devices and risk of uterine perforation: Current perspectives.","volume":"7","author":"Rowlands","year":"2016","journal-title":"Open Access J Contracept."},{"key":"B12","doi-asserted-by":"publisher","first-page":"735","DOI":"10.2147\/IJWH.S63167","article-title":"Role of uterine forces in intrauterine device embedment, perforation, and expulsion.","volume":"6","author":"Goldstuck","year":"2014","journal-title":"Int J Womens Health."},{"key":"B13","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1016\/j.ijgo.2009.12.018","article-title":"A 10-year experience in removing Chinese intrauterine devices.","volume":"109","author":"Cheung","year":"2010","journal-title":"Int J Gynaecol Obstet."},{"key":"B14","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1016\/j.jmig.2013.12.123","article-title":"Perforated intraperitoneal intrauterine contraceptive devices: Diagnosis, management, and clinical outcomes.","volume":"21","author":"Kho","year":"2014","journal-title":"J Minim Invasive Gynecol."},{"key":"B15","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1111\/j.1471-0528.1969.tb05817.x","article-title":"Small bowel obstruction due to perforation by a closed ring type intrauterine device (Antigon).","volume":"76","author":"Haspels","year":"1969","journal-title":"J Obstet Gynaecol Br Commonw."},{"key":"B16","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1097\/00006254-198108000-00001","article-title":"Complete and partial uterine perforation and embedding following insertion of intrauterine devices. II. Diagnostic methods, prevention, and management.","volume":"36","author":"Zakin","year":"1981","journal-title":"Obstet Gynecol Surv."},{"key":"B17","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1016\/j.ogc.2019.07.005","article-title":"Ultrasound assessment of the intrauterine device.","volume":"46","author":"Evans","year":"2019","journal-title":"Obstet Gynecol Clin North Am."},{"key":"B18","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1148\/rg.322115068","article-title":"Migration of intrauterine devices: Radiologic findings and implications for patient care.","volume":"32","author":"Boortz","year":"2012","journal-title":"Radiographics."},{"key":"B19","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1080\/13625187.2021.1874337","article-title":"Dislocated intrauterine devices: Clinical presentations, diagnosis and management.","volume":"26","author":"Tabatabaei","year":"2021","journal-title":"Eur J Contracept Reprod Health Care."},{"key":"B20","doi-asserted-by":"publisher","first-page":"130","DOI":"10.4274\/jtgga.galenos.2020.2020.0003","article-title":"Considerations on a new, frameless copper-releasing intrauterine system for intracesarean insertion and its future clinical significance: A review.","volume":"21","author":"Kutlucan","year":"2020","journal-title":"J Turk Ger Gynecol Assoc."},{"key":"B21","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1186\/s12951-022-01329-5","article-title":"Recent progress in advanced biomaterials for long-acting reversible contraception.","volume":"20","author":"Yan","year":"2022","journal-title":"J Nanobiotechnology."},{"key":"B22","doi-asserted-by":"publisher","first-page":"101875","DOI":"10.1016\/j.jogoh.2020.101875","article-title":"The value of ultrasound guidance during IUD insertion in women with RVF uterus: A randomized controlled trial.","volume":"50","author":"Maged","year":"2021","journal-title":"J Gynecol Obstet Hum Reprod."},{"key":"B23","doi-asserted-by":"publisher","first-page":"2103","DOI":"10.1016\/S0140-6736(22)00015-0","article-title":"Intrauterine device-related uterine perforation incidence and risk (APEX-IUD): A large multisite cohort study.","volume":"399","author":"Reed","year":"2022","journal-title":"Lancet."},{"key":"B24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.15585\/mmwr.rr6504a1","article-title":"U.S. Selected practice recommendations for contraceptive use, 2016.","volume":"65","author":"Curtis","year":"2016","journal-title":"MMWR Recomm Rep."},{"key":"B25","doi-asserted-by":"publisher","first-page":"1-77","DOI":"10.15585\/mmwr.rr7303a1","article-title":"U.S. Selected practice recommendations for contraceptive use, 2024.","volume":"73","author":"Curtis","year":"2024","journal-title":"MMWR Recomm Rep."},{"key":"B26","doi-asserted-by":"publisher","first-page":"2013","DOI":"10.1001\/jama.2022.5448","article-title":"Long-Acting reversible contraception with contraceptive implants and intrauterine devices.","volume":"327","author":"Averbach","year":"2022","journal-title":"JAMA."},{"key":"B27","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1136\/bmjsrh-2022-201738","article-title":"Words matter: Perforation\u2026 or transmural migration?","volume":"49","author":"Amaya","year":"2023","journal-title":"BMJ Sex Reprod Health."}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2025.1613116\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,7]],"date-time":"2025-07-07T04:10:42Z","timestamp":1751861442000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2025.1613116\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,7]]},"references-count":27,"alternative-id":["10.3389\/fmed.2025.1613116"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2025.1613116","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,7]]},"article-number":"1613116"}}