{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T19:06:22Z","timestamp":1791140782328,"version":"4.1.0"},"reference-count":40,"publisher":"Frontiers Media SA","license":[{"start":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T00:00:00Z","timestamp":1775692800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["frontiersin.org"],"crossmark-restriction":true},"short-container-title":["Front. Med."],"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>AM2UH was a novel bifocal hybrid extend the depth of focus (EDF) intraocular lens (IOL). This study is to evaluate the effectiveness and safety by comparing it with a monofocal IOL (AW-UV).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A prospective, comparative, single-center study. 37 patients (37 eyes) were implanted with novel hybrid EDF IOL model AM2UH. 36 patients (36 eyes) were implanted with monofocal IOL model AW-UV. At 6\u202fmonths postoperatively, the visual acuity (uncorrected and distance corrected), defocus curves, refractive outcomes, contrast sensitivity, questionnaires of visual quality were assessed and compared between 2 groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Compared to AW-UV, AM2UH showed non-inferior monocular corrected distance visual acuity (\n                      <jats:italic>p<\/jats:italic>\n                      \u202f&amp;gt;\u202f0.05), but superior intermediate and near visual acuity (all\n                      <jats:italic>p<\/jats:italic>\n                      \u202f&amp;lt;\u202f0.05). Additionally, AM2UH provided satisfactory DCVA at 1.0\u202fm (0.15\u202f\u00b1\u202f0.07 logMAR) and an extended depth of focus, with an increase of 1.08\u202fD at the 0.2 logMAR. AM2UH group showed high spectacle independence rate and satisfaction rates about intermediate and near vision. There were no significant differences in contrast sensitivity, the incidences of photic phenomena, intraocular pressure and adverse events between 2 groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>AM2UH IOL is an effective and safe EDF IOL that offers satisfactory intermediate vision and distance vision, improves near vision, and delivers an extended visual range while maintaining favorable visual quality.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical trial registration<\/jats:title>\n                    <jats:p>Identifier: MR-50-25-086616.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3389\/fmed.2026.1804708","type":"journal-article","created":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T04:10:15Z","timestamp":1775707815000},"update-policy":"https:\/\/doi.org\/10.3389\/crossmark-policy","source":"Crossref","is-referenced-by-count":1,"title":["Clinical outcomes of effectiveness and safety in cataract patients implanted with the novel hybrid extended depth-of-focus intraocular lens AM2UH: a prospective study"],"prefix":"10.3389","volume":"13","author":[{"given":"Qi","family":"Guo","sequence":"first","affiliation":[{"name":"Chongqing Aier Eye Hospital, Aier Eye Hospital Group","place":["Chongqing, China"]},{"name":"Department of Ophthalmology, The First School of Clinical Medicine, Jinan University","place":["Guangzhou, Guangdong, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuanjun","family":"Huang","sequence":"additional","affiliation":[{"name":"Chongqing Aier Eye Hospital, Aier Eye Hospital Group","place":["Chongqing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yinping","family":"Yang","sequence":"additional","affiliation":[{"name":"Chongqing Aier Eye Hospital, Aier Eye Hospital Group","place":["Chongqing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lu","family":"Yuan","sequence":"additional","affiliation":[{"name":"Chongqing Aier Eye Hospital, Aier Eye Hospital Group","place":["Chongqing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Changyan","family":"Liu","sequence":"additional","affiliation":[{"name":"Chongqing Aier Eye Hospital, Aier Eye Hospital Group","place":["Chongqing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunhong","family":"Xu","sequence":"additional","affiliation":[{"name":"Chongqing Aier Eye Hospital, Aier Eye Hospital Group","place":["Chongqing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Liu","sequence":"additional","affiliation":[{"name":"Chongqing Aier Eye Hospital, Aier Eye Hospital Group","place":["Chongqing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jilin","family":"Tan","sequence":"additional","affiliation":[{"name":"Chongqing Aier Eye Hospital, Aier Eye Hospital Group","place":["Chongqing, China"]},{"name":"Department of Ophthalmology, The First School of Clinical Medicine, Jinan University","place":["Guangzhou, Guangdong, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1965","published-online":{"date-parts":[[2026,4,9]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"414","DOI":"10.3760\/cma.j.cn112142-20250324-00127","article-title":"Chinese expert consensus on the clinical application of presbyopia-correcting intraocular lenses (2025)","volume":"61","year":"2025","journal-title":"Zhonghua Yan Ke Za Zhi"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.ajo.2017.08.020","article-title":"Cataract surgery from 1918 to the present and future-just imagine!","volume":"185","author":"Olson","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/j.survophthal.2019.02.012","article-title":"Multifocal versus monofocal intraocular lenses for age-related cataract patients: a system review and meta-analysis based on randomized controlled trials","volume":"64","author":"Cao","year":"2019","journal-title":"Surv Ophthalmol"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/j.jcrs.2010.11.032","article-title":"Dissatisfaction after implantation of multifocal intraocular lenses","volume":"37","author":"de Vries","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/j.ajo.2019.03.019","article-title":"Cost-effectiveness analysis of multifocal intraocular lenses compared to monofocal intraocular lenses in cataract surgery","volume":"208","author":"Hu","year":"2019","journal-title":"Am J Ophthalmol"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"3639","DOI":"10.12998\/wjcc.v10.i12.3639","article-title":"Tilt and decentration with various intraocular lenses: a narrative review","volume":"10","author":"Chen","year":"2022","journal-title":"World J Clin Cases"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1097\/j.jcrs.0000000000000109","article-title":"Extended depth-of-focus technology in intraocular lenses","volume":"46","author":"Kohnen","year":"2020","journal-title":"J Cataract Refract Surg"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1097\/APO.0000000000000296","article-title":"Extended depth-of-field intraocular lenses: an update","volume":"9","author":"Kanclerz","year":"2020","journal-title":"Asia Pac J Ophthalmol (Phila)."},{"key":"ref9","doi-asserted-by":"publisher","first-page":"1268","DOI":"10.1016\/j.jcrs.2016.06.033","article-title":"Clinical outcomes of a new extended range of vision intraocular lens: international multicenter concerto study","volume":"42","author":"Cochener","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"e91413","DOI":"10.7759\/cureus.91413","article-title":"Comparison of outcomes of non-diffractive extended depth of focus intraocular lens and diffractive extended depth of focus intraocular lens","volume":"17","author":"Vora","year":"2025","journal-title":"Cureus"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1038\/s41433-024-03041-0","article-title":"Optical and clinical simulated performance of a new refractive extended depth of focus intraocular lens","volume":"38","author":"Alarcon","year":"2024","journal-title":"Eye (Lond)"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"563632","DOI":"10.2147\/IJGM.S563632","article-title":"Comparison of postoperative visual acuity and visual quality among vision enhancing bifocal intraocular lenses (AM4UH), bifocal IOLs, and monofocal IOLs","volume":"19","author":"Xu","year":"2026","journal-title":"Int J Gen Med"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"191","DOI":"10.3760\/cma.j.cn115909-20240921-00310","article-title":"Vitro assessment of the optical performance for various near addition bifocal extended depth of focus IOLs","volume":"27","author":"Huang","year":"2025","journal-title":"Chin J Optom Ophthalmol Vis Sci"},{"key":"ref14","year":"2018"},{"key":"ref15","year":"2024"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"2151","DOI":"10.1038\/s41433-025-03819-w","article-title":"Non-inferiority trials in clinical ophthalmology: a systematic review","volume":"39","author":"Li","year":"2025","journal-title":"Eye (Lond)"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"4801","DOI":"10.2147\/OPTH.S560191","article-title":"Outcomes of bilateral implantation of a new aspheric hydrophobic non-diffractive extended depth of focus IOL with a mini-monovision approach","volume":"19","author":"Kuo","year":"2025","journal-title":"Clin Ophthalmol"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"1075693","DOI":"10.3389\/fmed.2022.1075693","article-title":"Evaluation value of subjective visual quality examination on surgical indications of the early cataracts based on objective scatter index values","volume":"9","author":"Li","year":"2022","journal-title":"Front Med Lausanne"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"3989","DOI":"10.1007\/s10792-023-02802-2","article-title":"The tolerance of refractive errors of extended depth of focus intraocular lens in patients with previous corneal refractive surgery","volume":"43","author":"Zheng","year":"2023","journal-title":"Int Ophthalmol"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"1579025","DOI":"10.3389\/fmed.2025.1579025","article-title":"Clinical outcomes after mix-and-match implantation of monofocal and refractive multifocal intraocular lenses after surgery","volume":"12","author":"Xing","year":"2026","journal-title":"Front Med Lausanne"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"572237","DOI":"10.2147\/OPTH.S572237","article-title":"Comparison of visual performance and patient satisfaction between two trifocal intraocular lenses: a prospective, paired-eye comparative study","volume":"20","author":"Kang","year":"2026","journal-title":"Clin Ophthalmol"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"4","DOI":"10.4103\/tjo.tjo_136_18","article-title":"Intraocular lens correction of presbyopia","volume":"9","author":"Sieburth","year":"2019","journal-title":"Taiwan J Ophthalmol"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1016\/j.ophtha.2016.09.039","article-title":"Special report: American Academy of Ophthalmology Task Force consensus statement for extended depth of focus intraocular lenses","volume":"124","author":"MacRae","year":"2017","journal-title":"Ophthalmology"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1097\/j.jcrs.0000000000000978","article-title":"Clinical outcomes in a U.S. registration study of a new EDOF intraocular lens with a nondiffractive design","volume":"48","author":"McCabe","year":"2022","journal-title":"J Cataract Refract Surg"},{"key":"ref25","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1016\/j.jcrs.2009.11.018","article-title":"Intermediate visual function with different multifocal intraocular lens models","volume":"36","author":"Alfonso","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"e102369","DOI":"10.7759\/cureus.102369","article-title":"Comparative evaluation of visual outcomes and patient satisfaction after eyecryl SERT versus TECNIS eyhance intraocular lens implantation in cataract patients","volume":"18","author":"Ganesh","year":"2026","journal-title":"Cureus."},{"key":"ref27","doi-asserted-by":"publisher","first-page":"e002025","DOI":"10.1136\/bmjophth-2024-002025","article-title":"Meta-analysis of defocus curves of monofocal, enhanced monofocal and extended depth of focus IOLs","volume":"10","author":"Srinivasan","year":"2025","journal-title":"BMJ Open Ophthalmol"},{"key":"ref28","doi-asserted-by":"publisher","first-page":"1071","DOI":"10.1097\/j.jcrs.0000000000001742","article-title":"Visual performance of a novel wavefront shaping EDOF intraocular lens on a new hydrophobic acrylic platform","volume":"51","author":"Berdahl","year":"2025","journal-title":"J Cataract Refract Surg"},{"key":"ref29","doi-asserted-by":"publisher","first-page":"4294","DOI":"10.1364\/BOE.8.004294","article-title":"Extended depth of focus intraocular lens: chromatic performance","volume":"8","author":"Mill\u00e1n","year":"2017","journal-title":"Biomed Opt Express"},{"key":"ref30","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1038\/s41433-024-03039-8","article-title":"Quality of vision clinical outcomes for a new fully-refractive extended depth of focus intraocular lens","volume":"38","author":"Corbett","year":"2024","journal-title":"Eye (Lond)"},{"key":"ref31","doi-asserted-by":"publisher","first-page":"4967","DOI":"10.3390\/jcm14144967","article-title":"Comparative outcomes of the next-generation extended depth-of-focus intraocular lens and enhanced monofocal intraocular lens in cataract surgery","volume":"14","author":"Kim","year":"2025","journal-title":"J Clin Med"},{"key":"ref32","doi-asserted-by":"publisher","first-page":"1368","DOI":"10.3390\/jcm15041368","article-title":"Comparative photopic and mesopic visual performance of enhanced monofocal versus non-diffractive extended depth-of-focus intraocular lenses","volume":"15","author":"Baoud Ould Haddi","year":"2026","journal-title":"J Clin Med"},{"key":"ref33","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1097\/APO.0000000000000253","article-title":"AcrySof IQ PanOptix intraocular lens versus extended depth of focus intraocular lens and trifocal intraocular lens: a clinical overview","volume":"8","author":"Sudhir","year":"2019","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"key":"ref34","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1111\/aos.13554","article-title":"Spectacle use after routine cataract surgery: a study from the Swedish National Cataract Register","volume":"96","author":"Farhoudi","year":"2018","journal-title":"Acta Ophthalmol"},{"key":"ref35","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1016\/j.jcrs.2016.01.014","article-title":"Efficacy and safety of multifocal intraocular lenses following cataract and refractive lens exchange: meta analysis of peer-reviewed publications","volume":"42","author":"Rosen","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"ref36","doi-asserted-by":"publisher","first-page":"104575","DOI":"10.1016\/j.jfo.2025.104575","article-title":"ILUSY+ study: spectacle independence and visual quality of life after bilateral implantation of synthesis+ versus monofocal intraocular lenses","volume":"48","author":"Fabiani","year":"2025","journal-title":"J Fr Ophtalmol"},{"key":"ref37","doi-asserted-by":"publisher","first-page":"572703","DOI":"10.2147\/OPTH.S572703","article-title":"Patient reported outcomes and visual acuity after bilateral implantation of a next generation presbyopia correcting intraocular lens","volume":"20","author":"Hacopian","year":"2026","journal-title":"Clin Ophthalmol"},{"key":"ref38","doi-asserted-by":"publisher","first-page":"2325","DOI":"10.2147\/OPTH.S232800","article-title":"Visual outcomes, visual quality and patient satisfaction: comparing a blended bifocal approach to bilateral extended depth of focus intraocular lens implantation","volume":"13","author":"Hammond","year":"2019","journal-title":"Clin Ophthalmol"},{"key":"ref39","doi-asserted-by":"publisher","first-page":"520","DOI":"10.3928\/1081597X-20200612-01","article-title":"Enhancing the intermediate vision of monofocal intraocular lenses using a higher order aspheric optic","volume":"36","author":"Alarcon","year":"2020","journal-title":"J Refract Surg"},{"key":"ref40","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/j.zemedi.2017.03.003","article-title":"Aberration-free intraocular lenses - what does this really mean?","volume":"27","author":"Langenbucher","year":"2017","journal-title":"Z Med Phys"}],"container-title":["Frontiers in Medicine"],"original-title":[],"link":[{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1804708\/full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T04:10:22Z","timestamp":1775707822000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.frontiersin.org\/articles\/10.3389\/fmed.2026.1804708\/full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,9]]},"references-count":40,"alternative-id":["10.3389\/fmed.2026.1804708"],"URL":"https:\/\/doi.org\/10.3389\/fmed.2026.1804708","relation":{},"ISSN":["2296-858X"],"issn-type":[{"value":"2296-858X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,9]]},"article-number":"1804708"}}